-
1
-
-
0032935092
-
Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial
-
Calkins H, Yong P, Miller JM, Olshansky B, Carlson M, Saul JP, Huang SK, Liem LB, Klein LS, Moser SA, Bloch DA, Gillette P, Prystowsky E. Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial: The ATAKR Multicenter Investigators Group. Circulation. 1999;99:262-270. (Pubitemid 29056369)
-
(1999)
Circulation
, vol.99
, Issue.2
, pp. 262-270
-
-
Calkins, H.1
Yong, P.2
Miller, J.M.3
Olshansky, B.4
Carlson, M.5
Saul, J.P.6
Stephen Huang, S.K.7
Liem, L.B.8
Klein, L.S.9
Moser, S.A.10
Bloch, D.A.11
Gillette, P.12
Prystowsky, E.13
-
2
-
-
0034700286
-
Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation
-
Pappone C, Rosanio S, Oreto G, Tocchi M, Gugliotta F, Vicedomini G, Salvati A, Dicandia C, Mazzone P, Santinelli V, Gulletta S, Chierchia S. Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation. Circulation. 2000;102: 2619-2628.
-
(2000)
Circulation.
, vol.102
, pp. 2619-2628
-
-
Pappone, C.1
Rosanio, S.2
Oreto, G.3
Tocchi, M.4
Gugliotta, F.5
Vicedomini, G.6
Salvati, A.7
Dicandia, C.8
Mazzone, P.9
Santinelli, V.10
Gulletta, S.11
Chierchia, S.12
-
3
-
-
0034696530
-
Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy
-
Marchlinski FE, Callans DJ, Gottlieb CD, Zado E. Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. Circulation. 2000;101: 1288-1296. (Pubitemid 30158617)
-
(2000)
Circulation
, vol.101
, Issue.11
, pp. 1288-1296
-
-
Marchlinski, F.E.1
Callans, D.J.2
Gottlieb, C.D.3
Zado, E.4
-
5
-
-
19944430314
-
Recovered pulmonary vein conductiona as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: Lessons from double lasso technique
-
DOI 10.1161/01.CIR.0000151289.73085.36
-
Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, Schaumann A, Chun J, Falk P, Hennig D, Liu X, Bansch D, Kuck KH. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: Lessons from double lasso technique. Circulation. 2005;111: 127-135. (Pubitemid 40139722)
-
(2005)
Circulation
, vol.111
, Issue.2
, pp. 127-135
-
-
Ouyang, F.1
Antz, M.2
Ernst, S.3
Hachiya, H.4
Mavrakis, H.5
Deger, F.T.6
Schaumann, A.7
Chun, J.8
Falk, P.9
Hennig, D.10
Liu, X.11
Bansch, D.12
Kuck, K.-H.13
-
6
-
-
0027438063
-
Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle: Implications for catheter ablation
-
Nath S, Lynch C III, Whayne JG, Haines DE. Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle: Implications for catheter ablation Circulation. 1993;88:1826-1831. (Pubitemid 23296930)
-
(1993)
Circulation
, vol.88
, Issue.4
, pp. 1826-1831
-
-
Nath, S.1
Lynch III, C.2
Whayne, J.G.3
Haines, D.E.4
-
7
-
-
0242290981
-
Triggered, Navigated, Multi-Baseline Method for Proton Resonance Frequency Temperature Mapping With Respiratory Motion
-
DOI 10.1002/mrm.10608
-
Vigen KK, Daniel BL, Pauly JM, Butts K. Triggered, navigated, multibaseline method for proton resonance frequency temperature mapping with respiratory motion. Magn Reson Med. 2003;50:1003-1010. (Pubitemid 37356580)
-
(2003)
Magnetic Resonance in Medicine
, vol.50
, Issue.5
, pp. 1003-1010
-
-
Vigen, K.K.1
Daniel, B.L.2
Pauly, J.M.3
Butts, K.4
-
8
-
-
34249700320
-
Referenceless MR thermometry for monitoring thermal ablation in the prostate
-
DOI 10.1109/TMI.2007.892647
-
Rieke V, Kinsey AM, Ross AB, Nau WH, Diederich CJ, Sommer G, Pauly KB. Referenceless MR thermometry for monitoring thermal ablation in the prostate. IEEE Trans Med Imaging. 2007;26:813-821. (Pubitemid 46842916)
-
(2007)
IEEE Transactions on Medical Imaging
, vol.26
, Issue.6
, pp. 813-821
-
-
Rieke, V.1
Kinsey, A.M.2
Ross, A.B.3
Nau, W.H.4
Diederich, C.J.5
Sommer, G.6
Pauly, K.B.7
-
9
-
-
33745117579
-
Uterine leiomyomas: MR imaging- based thermometry and thermal dosimetry during focused ultrasound thermal ablation
-
McDannold N, Tempany CM, Fennessy FM, So MJ, Rybicki FJ, Stewart EA, Jolesz FA, Hynynen K. Uterine leiomyomas: MR imaging-based thermometry and thermal dosimetry during focused ultrasound thermal ablation. Radiology. 2006;240:263-272. (Pubitemid 43902618)
-
(2006)
Radiology
, vol.240
, Issue.1
, pp. 263-272
-
-
McDannold, N.1
Tempany, C.M.2
Fennessy, F.M.3
So, M.J.4
Rybicki, F.J.5
Stewart, E.A.6
Jolesz, F.A.7
Hynynen, K.8
-
10
-
-
33846490663
-
Nonenhanced magnetic resonance imaging for characterization of acute and subacute radiofrequency ablation lesions
-
DOI 10.1016/j.hrthm.2006.11.013, PII S1547527106021692
-
Schmidt EJ, Reddy VK, Ruskin JN. Nonenhanced magnetic resonance imaging for characterization of acute and subacute radiofrequency ablation lesions. Heart Rhythm. 2007;4:215-217. (Pubitemid 46158707)
-
(2007)
Heart Rhythm
, vol.4
, Issue.2
, pp. 215-217
-
-
Schmidt, E.J.1
Reddy, V.K.2
Ruskin, J.N.3
-
11
-
-
36849111386
-
Proton resonance shift of water in the gas and liquid states
-
Hindman JC. Proton resonance shift of water in the gas and liquid states. J Chem Physics. 1965;44:4582-4592.
-
(1965)
J Chem Physics.
, vol.44
, pp. 4582-4592
-
-
Hindman, J.C.1
-
12
-
-
28444491453
-
Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: Review of validation studies
-
DOI 10.1080/02656730500096073
-
McDannold N. Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: Review of validation studies. Int J Hyperthermia. 2005;21:533-546. (Pubitemid 41726062)
-
(2005)
International Journal of Hyperthermia
, vol.21
, Issue.6
, pp. 533-546
-
-
McDannold, N.1
-
13
-
-
0031848730
-
Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry
-
Peters RD, Hinks RS, Henkelman RM. Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry. Magn Reson Med. 1998;40:454-459. (Pubitemid 28391907)
-
(1998)
Magnetic Resonance in Medicine
, vol.40
, Issue.3
, pp. 454-459
-
-
Peters, R.D.1
Hinks, R.S.2
Henkelman, R.M.3
-
14
-
-
0028785052
-
A precise and fast temperature mapping using water proton chemical shift
-
Ishihara Y, Calderon A, Watanabe H, Okamoto K, Suzuki Y, Kuroda K. A precise and fast temperature mapping using water proton chemical shift. Magn Reson Med. 1995;34:814-823.
-
(1995)
Magn Reson Med.
, vol.34
, pp. 814-823
-
-
Ishihara, Y.1
Calderon, A.2
Watanabe, H.3
Okamoto, K.4
Suzuki, Y.5
Kuroda, K.6
-
16
-
-
30344443403
-
Characterization of radiofrequency ablation lesions with gadolinium-enhanced cardiovascular magnetic resonance imaging
-
DOI 10.1016/j.jacc.2005.07.070, PII S0735109705024952
-
Dickfeld T, Kato R, Zviman M, Lai S, Meininger G, Lardo AC, Roguin A, Blumke D, Berger R, Calkins H, Halperin H. Characterization of radiofrequency ablation lesions with gadolinium-enhanced cardiovascular magnetic resonance imaging. J Am Coll Cardiol. 2006;47:370-378. (Pubitemid 43063257)
-
(2006)
Journal of the American College of Cardiology
, vol.47
, Issue.2
, pp. 370-378
-
-
Dickfeld, T.1
Kato, R.2
Zviman, M.3
Lai, S.4
Meininger, G.5
Lardo, A.C.6
Roguin, A.7
Blumke, D.8
Berger, R.9
Calkins, H.10
Halperin, H.11
-
17
-
-
28444464393
-
Magnetic susceptibility effects on the accuracy of MR temperature monitoring by the proton resonance frequency method
-
DOI 10.1002/jmri.20438
-
Boss A, Graf H, Muller-Bierl B, Clasen S, Schmidt D, Pereira PL, Schick F. Magnetic susceptibility effects on the accuracy of MR temperature monitoring by the proton resonance frequency method. J Magn Reson Imaging. 2005;22:813-820. (Pubitemid 41741253)
-
(2005)
Journal of Magnetic Resonance Imaging
, vol.22
, Issue.6
, pp. 813-820
-
-
Boss, A.1
Graf, H.2
Muller-Bierl, B.3
Clasen, S.4
Schmidt, D.5
Pereira, P.L.6
Schick, F.7
-
18
-
-
0024364286
-
Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall
-
DOI 10.1111/j.1540-8159.1989.tb05034.x
-
Haines DE, Watson DD. Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall. Pacing Clin Electrophysiol. 1989;12:962-976. (Pubitemid 19158807)
-
(1989)
PACE - Pacing and Clinical Electrophysiology
, vol.12
, Issue.6
, pp. 962-976
-
-
Haines, D.E.1
Watson, D.D.2
-
19
-
-
0028269756
-
Radiofrequency catheter ablation guided by intracardiac echocardiography
-
Chu E, Fitzpatrick AP, Chin MC, Sudhir K, Yock PG, Lesh MD. Radiofrequency catheter ablation guided by intracardiac echocardiography. Circulation. 1994;89:1301-1305. (Pubitemid 24076558)
-
(1994)
Circulation
, vol.89
, Issue.3
, pp. 1301-1305
-
-
Chu, E.1
Fitzpatrick, A.P.2
Chin, M.C.3
Sudhir, K.4
Yock, P.G.5
Lesh, M.D.6
-
20
-
-
34247364138
-
Utility of intracardiac echocardiography in left heart ablation for tachyarrhythmias
-
DOI 10.1111/j.1540-8175.2007.00426.x
-
Ren JF, Marchlinski FE. Utility of intracardiac echocardiography in left heart ablation for tachyarrhythmias. Echocardiography. 2007;24: 533-540. (Pubitemid 46643043)
-
(2007)
Echocardiography
, vol.24
, Issue.5
, pp. 533-540
-
-
Ren, J.-F.1
Marchlinski, F.E.2
-
21
-
-
58949092781
-
Temporal left atrial lesion formation after ablation of atrial fibrillation
-
Badger TJ, Oakes RS, Daccarett M, Burgon NS, Akoum N, Fish EN, Blauer JJ, Rao SN, Adjei-Poku Y, Kholmovski EG, Vijayakumar S, Di Bella EV, MacLeod RS, Marrouche NF. Temporal left atrial lesion formation after ablation of atrial fibrillation. Heart Rhythm. 2009;6: 161-168.
-
(2009)
Heart Rhythm.
, vol.6
, pp. 161-168
-
-
Badger, T.J.1
Oakes, R.S.2
Daccarett, M.3
Burgon, N.S.4
Akoum, N.5
Fish, E.N.6
Blauer, J.J.7
Rao, S.N.8
Adjei-Poku, Y.9
Kholmovski, E.G.10
Vijayakumar, S.11
Di Bella, E.V.12
MacLeod, R.S.13
Marrouche, N.F.14
-
22
-
-
33846512133
-
Characterization of acute and subacute radiofrequency ablation lesions with nonenhanced magnetic resonance imaging
-
DOI 10.1016/j.hrthm.2006.10.019, PII S1547527106021400
-
Dickfeld T, Kato R, Zviman M, Nazarian S, Dong J, Ashikaga H, Lardo AC, Berger RD, Calkins H, Halperin H. Characterization of acute and subacute radiofrequency ablation lesions with nonenhanced magnetic resonance imaging. Heart Rhythm. 2007;4:208-214. (Pubitemid 46158699)
-
(2007)
Heart Rhythm
, vol.4
, Issue.2
, pp. 208-214
-
-
Dickfeld, T.1
Kato, R.2
Zviman, M.3
Nazarian, S.4
Dong, J.5
Ashikaga, H.6
Lardo, A.C.7
Berger, R.D.8
Calkins, H.9
Halperin, H.10
-
23
-
-
1842590376
-
Stability of Real-Time MR Temperature Mapping in Healthy and Diseased Human Liver
-
DOI 10.1002/jmri.20019
-
Weidensteiner C, Kerioui N, Quesson B, de Senneville BD, Trillaud H, Moonen CT. Stability of real-time MR temperature mapping in healthy and diseased human liver. J Magn Reson Imaging. 2004;19:438-446. (Pubitemid 38437151)
-
(2004)
Journal of Magnetic Resonance Imaging
, vol.19
, Issue.4
, pp. 438-446
-
-
Weidensteiner, C.1
Kerioui, N.2
Quesson, B.3
De Senneville, B.D.4
Trillaud, H.5
Moonen, C.T.W.6
-
24
-
-
0034089502
-
Monitoring of high-intensity focused ultrasound-induced temperature changes in vitro using an interleaved spiral acquisition
-
DOI 10.1002/1522-2594(200006)43:6<909::AID-MRM20>3.0.CO;2-P
-
Stafford RJ, Hazle JD, Glover GH. Monitoring of high-intensity focused ultrasound-induced temperature changes in vitro using an interleaved spiral acquisition. Magn Reson Med. 2000;43:909-912. (Pubitemid 30387615)
-
(2000)
Magnetic Resonance in Medicine
, vol.43
, Issue.6
, pp. 909-912
-
-
Stafford, R.J.1
Hazle, J.D.2
Glover, G.H.3
-
25
-
-
0035112474
-
MRI monitoring of the thermal ablation of tissue: Effects of long exposure times
-
DOI 10.1002/jmri.1061
-
McDannold N, Hynynen K, Jolesz F. MRI monitoring of the thermal ablation of tissue: Effects of long exposure times. J Magn Reson Imaging. 2001;13:421-427. (Pubitemid 32173410)
-
(2001)
Journal of Magnetic Resonance Imaging
, vol.13
, Issue.3
, pp. 421-427
-
-
McDannold, N.1
Hynynen, K.2
Jolesz, F.3
-
27
-
-
33845368376
-
Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field
-
DOI 10.1007/s10334-006-0050-2
-
El-Sharkawy AM, Schar M, Bottomley PA, Atalar E. Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field. MAGMA. 2006;19:223-236. (Pubitemid 44884278)
-
(2006)
Magnetic Resonance Materials in Physics, Biology and Medicine
, vol.19
, Issue.5
, pp. 223-236
-
-
El-Sharkawy, A.M.1
Schar, M.2
Bottomley, P.A.3
Atalar, E.4
-
28
-
-
33745686043
-
Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI
-
Lepetit-Coiffe M, Quesson B, Seror O, Dumont E, Le Bail B, Moonen CT, Trillaud H. Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI. J Magn Reson Imaging. 2006;24:152-159.
-
(2006)
J Magn Reson Imaging.
, vol.24
, pp. 152-159
-
-
Lepetit-Coiffe, M.1
Quesson, B.2
Seror, O.3
Dumont, E.4
Le Bail, B.5
Moonen, C.T.6
Trillaud, H.7
-
29
-
-
0032924339
-
Heat-source orientation and geometry dependence in proton-resonance frequency shift magnetic resonance thermometry
-
DOI 10.1002/(SICI)1522-2594(199905)41:5<909::AID-MRM9>3.0.CO;2-N
-
Peters RD, Hinks RS, Henkelman RM. Heat-source orientation and geometry dependence in proton-resonance frequency shift magnetic resonance thermometry. Magn Reson Med. 1999;41:909-918. (Pubitemid 29211133)
-
(1999)
Magnetic Resonance in Medicine
, vol.41
, Issue.5
, pp. 909-918
-
-
Peters, R.D.1
Hinks, R.S.2
Henkelman, R.M.3
-
30
-
-
0029112548
-
Noninvasive MRI thermometry with the proton resonance frequency method: Study of susceptibility effects
-
De Poorter J. Noninvasive MRI thermometry with the proton resonance frequency method: Study of susceptibility effects. Magn Reson Med. 1995;34:359-367.
-
(1995)
Magn Reson Med.
, vol.34
, pp. 359-367
-
-
De Poorter, J.1
-
31
-
-
70350713960
-
Accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas
-
Craciunescu OI, Stauffer PR, Soher BJ, Wyatt CR, Arabe O, Maccarini P, Das SK, Cheng KS, Wong TZ, Jones EL, Dewhirst MW, Vujaskovic Z, MacFall JR. Accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas. Med Phys. 2009;36:4848-4858.
-
(2009)
Med Phys.
, vol.36
, pp. 4848-4858
-
-
Craciunescu, O.I.1
Stauffer, P.R.2
Soher, B.J.3
Wyatt, C.R.4
Arabe, O.5
Maccarini, P.6
Das, S.K.7
Cheng, K.S.8
Wong, T.Z.9
Jones, E.L.10
Dewhirst, M.W.11
Vujaskovic, Z.12
MacFall, J.R.13
|