메뉴 건너뛰기




Volumn 120, Issue 1, 2015, Pages 18-25

Fibrinogen measurements in plasma and whole blood: A performance evaluation study of the dry-hematology system

Author keywords

[No Author keywords available]

Indexed keywords

ALBUMIN; ANTIGEN; FIBRINOGEN; HEPARIN; HETASTARCH; HUMAN ALBUMIN; SODIUM CHLORIDE;

EID: 84924065301     PISSN: 00032999     EISSN: 15267598     Source Type: Journal    
DOI: 10.1213/ANE.0000000000000448     Document Type: Article
Times cited : (41)

References (33)
  • 1
    • 84900462907 scopus 로고    scopus 로고
    • Fibrinogen as a therapeutic target for bleeding: A review of critical levels and replacement therapy
    • Levy JH, Welsby I, Goodnough LT. Fibrinogen as a therapeutic target for bleeding: a review of critical levels and replacement therapy. Transfusion 2014;54:1389-405
    • (2014) Transfusion , vol.54 , pp. 1389-1405
    • Levy, J.H.1    Welsby, I.2    Goodnough, L.T.3
  • 2
    • 0034964284 scopus 로고    scopus 로고
    • Fibrin and wound healing
    • Clark RA. Fibrin and wound healing. Ann N Y Acad Sci 2001;936:355-67
    • (2001) Ann N y Acad Sci , vol.936 , pp. 355-367
    • Clark, R.A.1
  • 3
    • 77249115271 scopus 로고    scopus 로고
    • Haemodilution-induced profibrinolytic state is mitigated by fresh-frozen plasma: Implications for early haemostatic intervention in massive haemorrhage
    • Bolliger D, Szlam F, Levy JH, Molinaro RJ, Tanaka KA. Haemodilution-induced profibrinolytic state is mitigated by fresh-frozen plasma: implications for early haemostatic intervention in massive haemorrhage. Br J Anaesth 2010;104:318-25
    • (2010) Br J Anaesth , vol.104 , pp. 318-325
    • Bolliger, D.1    Szlam, F.2    Levy, J.H.3    Molinaro, R.J.4    Tanaka, K.A.5
  • 4
    • 20444442768 scopus 로고    scopus 로고
    • Relationship between factor XIII activity, fibrinogen, haemostasis screening tests and postoperative bleeding in cardiopulmonary bypass surgery
    • Blome M, Isgro F, Kiessling AH, Skuras J, Haubelt H, Hellstern P, Saggau W. Relationship between factor XIII activity, fibrinogen, haemostasis screening tests and postoperative bleeding in cardiopulmonary bypass surgery. Thromb Haemost 2005;93:1101-7
    • (2005) Thromb Haemost , vol.93 , pp. 1101-1107
    • Blome, M.1    Isgro, F.2    Kiessling, A.H.3    Skuras, J.4    Haubelt, H.5    Hellstern, P.6    Saggau, W.7
  • 5
    • 78049340172 scopus 로고    scopus 로고
    • Pathophysiology and treatment of coagulopathy in massive hemorrhage and hemodilution
    • Bolliger D, Görlinger K, Tanaka KA. Pathophysiology and treatment of coagulopathy in massive hemorrhage and hemodilution. Anesthesiology 2010;113:1205-19
    • (2010) Anesthesiology , vol.113 , pp. 1205-1219
    • Bolliger, D.1    Görlinger, K.2    Tanaka, K.A.3
  • 6
    • 84856164446 scopus 로고    scopus 로고
    • Fibrinogen and hemostasis: A primary hemostatic target for the management of acquired bleeding
    • Levy JH, Szlam F, Tanaka KA, Sniecienski RM. Fibrinogen and hemostasis: a primary hemostatic target for the management of acquired bleeding. Anesth Analg 2012;114:261-74
    • (2012) Anesth Analg , vol.114 , pp. 261-274
    • Levy, J.H.1    Szlam, F.2    Tanaka, K.A.3    Sniecienski, R.M.4
  • 7
    • 33745551242 scopus 로고
    • Rapid physiological coagulation method in determination of fibrinogen [in German]
    • CLAUSS A. Rapid physiological coagulation method in determination of fibrinogen [in German]. Acta Haematol 1957;17:237-46
    • (1957) Acta Haematol , vol.17 , pp. 237-246
    • Clauss, A.1
  • 9
    • 78649728585 scopus 로고    scopus 로고
    • Comparison of the fibrinogen Clauss assay and the fibrinogen PT derived method in patients with dysfibrinogenemia
    • Miesbach W, Schenk J, Alesci S, Lindhoff-Last E. Comparison of the fibrinogen Clauss assay and the fibrinogen PT derived method in patients with dysfibrinogenemia. Thromb Res 2010;126:e428-33
    • (2010) Thromb Res , vol.126 , pp. e428-33
    • Miesbach, W.1    Schenk, J.2    Alesci, S.3    Lindhoff-Last, E.4
  • 10
    • 80051669224 scopus 로고    scopus 로고
    • A comparison of fibrinogen measurement methods with fibrin clot elasticity assessed by thromboelastometry, before and after administration of fibrinogen concentrate in cardiac surgery patients
    • Solomon C, Cadamuro J, Ziegler B, Schöchl H, Varvenne M, SØrensen B, Hochleitner G, Rahe-Meyer N. A comparison of fibrinogen measurement methods with fibrin clot elasticity assessed by thromboelastometry, before and after administration of fibrinogen concentrate in cardiac surgery patients. Transfusion 2011;51:1695-706
    • (2011) Transfusion , vol.51 , pp. 1695-1706
    • Solomon, C.1    Cadamuro, J.2    Ziegler, B.3    Schöchl, H.4    Varvenne, M.5    SØrensen, B.6    Hochleitner, G.7    Rahe-Meyer, N.8
  • 11
    • 84881161245 scopus 로고    scopus 로고
    • Diagnosis of perioperative coagulopathy-plasma versus whole blood testing
    • Tanaka KA, Bader SO, Sturgil EL. Diagnosis of perioperative coagulopathy-plasma versus whole blood testing. J Cardiothorac Vasc Anesth 2013;27:S9-15
    • (2013) J Cardiothorac Vasc Anesth , vol.27 , pp. S9-15
    • Tanaka, K.A.1    Bader, S.O.2    Sturgil, E.L.3
  • 12
    • 78649994796 scopus 로고    scopus 로고
    • Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders
    • Fenger-Eriksen C, Moore GW, Rangarajan S, Ingerslev J, SØrensen B. Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders. Transfusion 2010;50:2571-6
    • (2010) Transfusion , vol.50 , pp. 2571-2576
    • Fenger-Eriksen, C.1    Moore, G.W.2    Rangarajan, S.3    Ingerslev, J.4    SØrensen, B.5
  • 13
    • 82255196088 scopus 로고    scopus 로고
    • Are the point-of-care diagnostics MULTIPLATE and ROTEM valid in the setting of high concentrations of heparin and its reversal with protamine?
    • Gertler R, Wiesner G, Tassani-Prell P, Braun SL, Martin K. Are the point-of-care diagnostics MULTIPLATE and ROTEM valid in the setting of high concentrations of heparin and its reversal with protamine? J Cardiothorac Vasc Anesth 2011;25:981-6
    • (2011) J Cardiothorac Vasc Anesth , vol.25 , pp. 981-986
    • Gertler, R.1    Wiesner, G.2    Tassani-Prell, P.3    Braun, S.L.4    Martin, K.5
  • 14
    • 84859097986 scopus 로고    scopus 로고
    • Comparison of whole blood fibrin-based clot tests in thrombelastography and thromboelastometry
    • Solomon C, SØrensen B, Hochleitner G, Kashuk J, Ranucci M, Schöchl H. Comparison of whole blood fibrin-based clot tests in thrombelastography and thromboelastometry. Anesth Analg 2012;114:721-30
    • (2012) Anesth Analg , vol.114 , pp. 721-730
    • Solomon, C.1    SØrensen, B.2    Hochleitner, G.3    Kashuk, J.4    Ranucci, M.5    Schöchl, H.6
  • 15
    • 82955247833 scopus 로고    scopus 로고
    • Principles and practice of thromboelastography in clinical coagulation management and transfusion practice
    • Bolliger D, Seeberger MD, Tanaka KA. Principles and practice of thromboelastography in clinical coagulation management and transfusion practice. Transfus Med Rev 2012;26:1-13
    • (2012) Transfus Med Rev , vol.26 , pp. 1-13
    • Bolliger, D.1    Seeberger, M.D.2    Tanaka, K.A.3
  • 17
    • 0007904996 scopus 로고    scopus 로고
    • Evaluation of a point-of-care coagulation device, the thrombolytic assessment system (TAS), for measuring prothrombin times, activated partial thromboplastin times, and high-dose heparin anticoagulation
    • Gosselin RC, Owings JT, Pollock ME, Larkin E. Evaluation of a point-of-care coagulation device, the thrombolytic assessment system (TAS), for measuring prothrombin times, activated partial thromboplastin times, and high-dose heparin anticoagulation. Lab Hematol 1998;4: 217-24
    • (1998) Lab Hematol , vol.4 , pp. 217-224
    • Gosselin, R.C.1    Owings, J.T.2    Pollock, M.E.3    Larkin, E.4
  • 18
    • 77950505052 scopus 로고    scopus 로고
    • WL. Comparison of plasma with whole blood prothrombin time and fibrinogen on the same instrument
    • Chandler
    • Amukele TK, Ferrell C, Chandler WL. Comparison of plasma with whole blood prothrombin time and fibrinogen on the same instrument. Am J Clin Pathol 2010;133:550-6
    • (2010) Am J Clin Pathol , vol.133 , pp. 550-556
    • Amukele, T.K.1    Ferrell, C.2
  • 19
    • 84862985254 scopus 로고    scopus 로고
    • The impact of hematocrit on fibrin clot formation assessed by rotational thromboelastometry
    • Ogawa S, Szlam F, Bolliger D, Nishimura T, Chen EP, Tanaka KA. The impact of hematocrit on fibrin clot formation assessed by rotational thromboelastometry. Anesth Analg 2012;115:16-21
    • (2012) Anesth Analg , vol.115 , pp. 16-21
    • Ogawa, S.1    Szlam, F.2    Bolliger, D.3    Nishimura, T.4    Chen, E.P.5    Tanaka, K.A.6
  • 20
    • 84855342985 scopus 로고    scopus 로고
    • A comparative evaluation of rotation thromboelastometry and standard coagulation tests in hemodilution-induced coagulation changes after cardiac surgery
    • Ogawa S, Szlam F, Chen EP, Nishimura T, Kim H, Roback JD, Levy JH, Tanaka KA. A comparative evaluation of rotation thromboelastometry and standard coagulation tests in hemodilution-induced coagulation changes after cardiac surgery. Transfusion 2012;52:14-22
    • (2012) Transfusion , vol.52 , pp. 14-22
    • Ogawa, S.1    Szlam, F.2    Chen, E.P.3    Nishimura, T.4    Kim, H.5    Roback, J.D.6    Levy, J.H.7    Tanaka, K.A.8
  • 21
    • 77949413099 scopus 로고    scopus 로고
    • Rotation thromboelastometry detects thrombocytopenia and hypofibrinogenaemia during orthotopic liver transplantation
    • Roullet S, Pillot J, Freyburger G, Biais M, Quinart A, Rault A, Revel P, Sztark F. Rotation thromboelastometry detects thrombocytopenia and hypofibrinogenaemia during orthotopic liver transplantation. Br J Anaesth 2010;104:422-8
    • (2010) Br J Anaesth , vol.104 , pp. 422-428
    • Roullet, S.1    Pillot, J.2    Freyburger, G.3    Biais, M.4    Quinart, A.5    Rault, A.6    Revel, P.7    Sztark, F.8
  • 22
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-68
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 23
    • 84856829761 scopus 로고    scopus 로고
    • A proposal for strength-of-Agreement criteria for Lin's concordance correlation coefficient
    • McBride GB. A proposal for strength-of-Agreement criteria for Lin's concordance correlation coefficient. NIWA Client Report. HAM2005-062.2005;1-10
    • (2005) NIWA Client Report. HAM 2005-062. , pp. 1-10
    • McBride, G.B.1
  • 24
    • 34548208591 scopus 로고    scopus 로고
    • Using the Bland-Altman method to measure agreement with repeated measures
    • Myles PS, Cui J. Using the Bland-Altman method to measure agreement with repeated measures. Br J Anaesth 2007;99: 309-11
    • (2007) Br J Anaesth , vol.99 , pp. 309-311
    • Myles, P.S.1    Cui, J.2
  • 25
    • 84655170265 scopus 로고    scopus 로고
    • Agreed statistics: Measurement method comparison
    • Bland JM, Altman DG. Agreed statistics: measurement method comparison. Anesthesiology 2012;116:182-5
    • (2012) Anesthesiology , vol.116 , pp. 182-185
    • Bland, J.M.1    Altman, D.G.2
  • 27
    • 0029617671 scopus 로고
    • Dextran and hydroxyethyl starch interfere with fibrinogen assays
    • Hiippala ST. Dextran and hydroxyethyl starch interfere with fibrinogen assays. Blood Coagul Fibrinolysis 1995;6:743-6
    • (1995) Blood Coagul Fibrinolysis , vol.6 , pp. 743-746
    • Hiippala, S.T.1
  • 28
    • 42449112966 scopus 로고    scopus 로고
    • Coagulation monitoring: Current techniques and clinical use of viscoelastic point-of-care coagulation devices
    • Ganter MT, Hofer CK. Coagulation monitoring: current techniques and clinical use of viscoelastic point-of-care coagulation devices. Anesth Analg 2008;106:1366-75
    • (2008) Anesth Analg , vol.106 , pp. 1366-1375
    • Ganter, M.T.1    Hofer, C.K.2
  • 30
    • 77950681467 scopus 로고    scopus 로고
    • Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-guided administration of fibrinogen concentrate and prothrombin complex concentrate
    • Schöchl H, Nienaber U, Hofer G, Voelckel W, Jambor C, Scharbert G, Kozek-Langenecker S, Solomon C. Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-guided administration of fibrinogen concentrate and prothrombin complex concentrate. Crit Care 2010;14:R55
    • (2010) Crit Care , vol.14 , pp. R55
    • Schöchl, H.1    Nienaber, U.2    Hofer, G.3    Voelckel, W.4    Jambor, C.5    Scharbert, G.6    Kozek-Langenecker, S.7    Solomon, C.8
  • 31
    • 84869459194 scopus 로고    scopus 로고
    • Haemostatic monitoring during postpartum haemorrhage and implications for management
    • Solomon C, Collis RE, Collins PW. Haemostatic monitoring during postpartum haemorrhage and implications for management. Br J Anaesth 2012;109:851-63
    • (2012) Br J Anaesth , vol.109 , pp. 851-863
    • Solomon, C.1    Collis, R.E.2    Collins, P.W.3
  • 32
    • 3042662496 scopus 로고    scopus 로고
    • The impact of factor XIII on coagulation kinetics and clot strength determined by thrombelastography
    • Nielsen VG, Gurley WQ Jr, Burch TM. The impact of factor XIII on coagulation kinetics and clot strength determined by thrombelastography. Anesth Analg 2004;99:120-3
    • (2004) Anesth Analg , vol.99 , pp. 120-123
    • Nielsen, V.G.1    Gurley, W.Q.2    Burch, T.M.3
  • 33
    • 70349568133 scopus 로고    scopus 로고
    • In vitro inhibition of factor XIII retards clot formation, reduces clot firmness, and increases fibrinolytic effects in whole blood
    • Jámbor C, Reul V, Schnider TW, Degiacomi P, Metzner H, Korte WC. In vitro inhibition of factor XIII retards clot formation, reduces clot firmness, and increases fibrinolytic effects in whole blood. Anesth Analg 2009;109:1023-8
    • (2009) Anesth Analg , vol.109 , pp. 1023-1028
    • Jámbor, C.1    Reul, V.2    Schnider, T.W.3    Degiacomi, P.4    Metzner, H.5    Korte, W.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.