메뉴 건너뛰기




Volumn 28, Issue 3, 2015, Pages 353-366

A model-based reconstruction for undersampled radial spin-echo DTI with variational penalties on the diffusion tensor

Author keywords

Compressed sensing; Diffusion tensor imaging; Iterative reconstruction; Model based image reconstruction; Non Cartesian imaging

Indexed keywords

CARTILAGE; CLUSTERING ALGORITHMS; COMPRESSED SENSING; DATA ACQUISITION; DIFFUSION; IMAGE RECONSTRUCTION; ITERATIVE METHODS; MAGNETIC RESONANCE IMAGING; SIGNAL TO NOISE RATIO; SPIN POLARIZATION; SYSTEMATIC ERRORS; TENSORS;

EID: 84924049592     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.3258     Document Type: Article
Times cited : (40)

References (72)
  • 2
  • 4
    • 0026501782 scopus 로고
    • Determination of fixed charge density in cartilage using nuclear magnetic resonance
    • Lesperance LM, Gray ML, Burstein D. Determination of fixed charge density in cartilage using nuclear magnetic resonance. J. Orthop. Res. 1992; 10: 1-13.
    • (1992) J. Orthop. Res. , vol.10 , pp. 1-13
    • Lesperance, L.M.1    Gray, M.L.2    Burstein, D.3
  • 5
    • 0029657894 scopus 로고    scopus 로고
    • Gd-DTPA2- as a measure of cartilage degradation
    • Bashir A, Gray ML, Burstein D. Gd-DTPA2- as a measure of cartilage degradation. Magn. Reson. Med. 1996; 36: 665-673.
    • (1996) Magn. Reson. Med. , vol.36 , pp. 665-673
    • Bashir, A.1    Gray, M.L.2    Burstein, D.3
  • 6
    • 40649092354 scopus 로고    scopus 로고
    • Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST)
    • Ling W, Regatte RR, Navon G, Jerschow A. Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST). Proc. Natl. Acad. Sci. U. S. A. 2008; 105: 2266-2270.
    • (2008) Proc. Natl. Acad. Sci. U. S. A. , vol.105 , pp. 2266-2270
    • Ling, W.1    Regatte, R.R.2    Navon, G.3    Jerschow, A.4
  • 8
    • 0027531941 scopus 로고
    • Analysis of water-macromolecule proton magnetization transfer in articular cartilage
    • Kim DK, Ceckler TL, Hascall VC, Calabro A, Balaban RS. Analysis of water-macromolecule proton magnetization transfer in articular cartilage. Magn. Reson. Med. 1993; 29: 211-215.
    • (1993) Magn. Reson. Med. , vol.29 , pp. 211-215
    • Kim, D.K.1    Ceckler, T.L.2    Hascall, V.C.3    Calabro, A.4    Balaban, R.S.5
  • 9
    • 84930043729 scopus 로고    scopus 로고
    • Techniques and applications of in vivo diffusion imaging of articular cartilage
    • Raya JG. Techniques and applications of in vivo diffusion imaging of articular cartilage. J. Magn. Reson. Imaging 2014, DOI: 10.1002/jmri.24767.
    • (2014) J. Magn. Reson. Imaging
    • Raya, J.G.1
  • 10
    • 44449169789 scopus 로고    scopus 로고
    • Anisotropy of collagen fibre alignment in bovine cartilage: comparison of polarised light microscopy and spatially resolved diffusion-tensor measurements
    • De Visser SK, Bowden JC, Wentrup-Byrne E, Rintoul L, Bostrom T, Pope JM, Momot KI. Anisotropy of collagen fibre alignment in bovine cartilage: comparison of polarised light microscopy and spatially resolved diffusion-tensor measurements. Osteoarthritis Cartilage 2008; 16: 689-697.
    • (2008) Osteoarthritis Cartilage , vol.16 , pp. 689-697
    • De Visser, S.K.1    Bowden, J.C.2    Wentrup-Byrne, E.3    Rintoul, L.4    Bostrom, T.5    Pope, J.M.6    Momot, K.I.7
  • 15
    • 0027624262 scopus 로고
    • Diffusion of small solutes in cartilage as measured by nuclear magnetic resonance (NMR) spectroscopy and imaging
    • Burstein D, Gray ML, Hartman AL, Gipe R, Foy BD. Diffusion of small solutes in cartilage as measured by nuclear magnetic resonance (NMR) spectroscopy and imaging. J. Orthop. Res. 1993; 11: 465-478.
    • (1993) J. Orthop. Res. , vol.11 , pp. 465-478
    • Burstein, D.1    Gray, M.L.2    Hartman, A.L.3    Gipe, R.4    Foy, B.D.5
  • 16
    • 84924053011 scopus 로고    scopus 로고
    • In vivo DTI of articular cartilage at 3T with a spin echo radial diffusion tensor imaging (RAISED) sequence
    • Raya JG, Dettmann E, Golestani A, Block KT. In vivo DTI of articular cartilage at 3T with a spin echo radial diffusion tensor imaging (RAISED) sequence. Proc. Int. Soc. Magn. Reson. Med. 2013; 21: 3530.
    • (2013) Proc. Int. Soc. Magn. Reson. Med. , vol.21 , pp. 3530
    • Raya, J.G.1    Dettmann, E.2    Golestani, A.3    Block, K.T.4
  • 18
    • 84902366515 scopus 로고    scopus 로고
    • Feasibility of in vivo diffusion tensor imaging of articular cartilage with coverage of all cartilage regions
    • Raya JG, Dettmann E, Notohamiprodjo M, Krasnokutsky S, Abramson S, Glaser C. Feasibility of in vivo diffusion tensor imaging of articular cartilage with coverage of all cartilage regions. Eur. Radiol. 2014; 24: 1700-1706.
    • (2014) Eur. Radiol. , vol.24 , pp. 1700-1706
    • Raya, J.G.1    Dettmann, E.2    Notohamiprodjo, M.3    Krasnokutsky, S.4    Abramson, S.5    Glaser, C.6
  • 19
    • 0032800434 scopus 로고    scopus 로고
    • High-resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acquisition of data with fast spin-echo) MRI
    • Trouard TP, Theilmann RJ, Altbach MI, Gmitro AF. High-resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acquisition of data with fast spin-echo) MRI. Magn. Reson. Med. 1999; 42: 11-18.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 11-18
    • Trouard, T.P.1    Theilmann, R.J.2    Altbach, M.I.3    Gmitro, A.F.4
  • 20
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn. Reson. Med. 1997; 38: 591-603.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 24
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn. Reson. Med. 2007; 58: 1182-1195.
    • (2007) Magn. Reson. Med. , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 25
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • Block KT, Uecker M, Frahm J. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn. Reson. Med. 2007; 57: 1086-1098.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 26
    • 60349119456 scopus 로고    scopus 로고
    • Regularized sensitivity encoding (SENSE) reconstruction using Bregman iterations
    • Liu B, King K, Steckner M, Xie J, Sheng J, Ying L. Regularized sensitivity encoding (SENSE) reconstruction using Bregman iterations. Magn. Reson. Med. 2009; 61: 145-152.
    • (2009) Magn. Reson. Med. , vol.61 , pp. 145-152
    • Liu, B.1    King, K.2    Steckner, M.3    Xie, J.4    Sheng, J.5    Ying, L.6
  • 27
    • 73149123165 scopus 로고    scopus 로고
    • Accelerating SENSE using compressed sensing
    • Liang D, Liu B, Wang J, Ying L. Accelerating SENSE using compressed sensing. Magn. Reson. Med. 2009; 62: 1574-1584.
    • (2009) Magn. Reson. Med. , vol.62 , pp. 1574-1584
    • Liang, D.1    Liu, B.2    Wang, J.3    Ying, L.4
  • 28
    • 77955586915 scopus 로고    scopus 로고
    • Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI
    • Otazo R, Kim D, Axel L, Sodickson DK. Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI. Magn. Reson. Med. 2010; 64: 767-776.
    • (2010) Magn. Reson. Med. , vol.64 , pp. 767-776
    • Otazo, R.1    Kim, D.2    Axel, L.3    Sodickson, D.K.4
  • 31
    • 84924028514 scopus 로고    scopus 로고
    • Advanced Methods for Radial Data Sampling in MRI. PhD thesis. Georg-August-Universitaet: Goettingen
    • Block T. Advanced Methods for Radial Data Sampling in MRI. PhD thesis. Georg-August-Universitaet: Goettingen, 2008.
    • (2008)
    • Block, T.1
  • 32
    • 70350751580 scopus 로고    scopus 로고
    • Model-based iterative reconstruction for radial fast spin-echo MRI
    • Block KT, Uecker M, Frahm J. Model-based iterative reconstruction for radial fast spin-echo MRI. IEEE Trans. Med. Imaging 2009; 28: 1759-1769.
    • (2009) IEEE Trans. Med. Imaging , vol.28 , pp. 1759-1769
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 34
    • 79960611551 scopus 로고    scopus 로고
    • Model-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI
    • Sumpf TJ, Uecker M, Boretius S, Frahm J. Model-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI. J. Magn. Reson. Imaging 2011; 34: 420-428.
    • (2011) J. Magn. Reson. Imaging , vol.34 , pp. 420-428
    • Sumpf, T.J.1    Uecker, M.2    Boretius, S.3    Frahm, J.4
  • 36
    • 84859719425 scopus 로고    scopus 로고
    • T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensing
    • Huang C, Graff CG, Clarkson EW, Bilgin A, Altbach MI. T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensing. Magn. Reson. Med. 2012; 67: 1355-1366.
    • (2012) Magn. Reson. Med. , vol.67 , pp. 1355-1366
    • Huang, C.1    Graff, C.G.2    Clarkson, E.W.3    Bilgin, A.4    Altbach, M.I.5
  • 37
    • 84886775274 scopus 로고    scopus 로고
    • Accelerating MR parameter mapping using sparsity-promoting regularization in parametric dimension
    • Velikina JV, Alexander AL, Samsonov A. Accelerating MR parameter mapping using sparsity-promoting regularization in parametric dimension. Magn. Reson. Med. 2013; 70: 1263-1273.
    • (2013) Magn. Reson. Med. , vol.70 , pp. 1263-1273
    • Velikina, J.V.1    Alexander, A.L.2    Samsonov, A.3
  • 41
    • 84881160013 scopus 로고    scopus 로고
    • Model-based reconstruction of undersampled diffusion tensor k-space data
    • Welsh CL, Dibella EVR, Adluru G, Hsu EW. Model-based reconstruction of undersampled diffusion tensor k-space data. Magn. Reson. Med. 2013; 70: 429-440.
    • (2013) Magn. Reson. Med. , vol.70 , pp. 429-440
    • Welsh, C.L.1    Dibella, E.V.R.2    Adluru, G.3    Hsu, E.W.4
  • 43
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • Rudin LI, Osher S, Fatemi E. Nonlinear total variation based noise removal algorithms. Phys. D 1992; 60: 259-268.
    • (1992) Phys. D , vol.60 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 44
    • 0037306521 scopus 로고    scopus 로고
    • Nonuniform fast Fourier transforms using min-max interpolation
    • Fessler JA, Sutton BP. Nonuniform fast Fourier transforms using min-max interpolation. IEEE Trans. Signal Process. 2003; 51: 560-574.
    • (2003) IEEE Trans. Signal Process. , vol.51 , pp. 560-574
    • Fessler, J.A.1    Sutton, B.P.2
  • 45
    • 0034567198 scopus 로고    scopus 로고
    • Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI
    • Skare S, Hedehus M, Moseley ME, Li TQ. Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI. J. Magn. Reson. 2000; 147: 340-352.
    • (2000) J. Magn. Reson. , vol.147 , pp. 340-352
    • Skare, S.1    Hedehus, M.2    Moseley, M.E.3    Li, T.Q.4
  • 46
    • 1842533406 scopus 로고    scopus 로고
    • The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study
    • Jones DK. The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study. Magn. Reson. Med. 2004; 51: 807-815.
    • (2004) Magn. Reson. Med. , vol.51 , pp. 807-815
    • Jones, D.K.1
  • 47
    • 34648819863 scopus 로고    scopus 로고
    • A framework for quality control and parameter optimization in diffusion tensor imaging: theoretical analysis and validation
    • Hasan KM. A framework for quality control and parameter optimization in diffusion tensor imaging: theoretical analysis and validation. Magn. Reson. Imaging 2007; 25: 1196-1202.
    • (2007) Magn. Reson. Imaging , vol.25 , pp. 1196-1202
    • Hasan, K.M.1
  • 48
    • 42549132337 scopus 로고    scopus 로고
    • Single-step nonlinear diffusion tensor estimation in the presence of microscopic and macroscopic motion
    • Aksoy M, Liu C, Moseley ME, Bammer R. Single-step nonlinear diffusion tensor estimation in the presence of microscopic and macroscopic motion. Magn. Reson. Med. 2008; 59: 1138-1150.
    • (2008) Magn. Reson. Med. , vol.59 , pp. 1138-1150
    • Aksoy, M.1    Liu, C.2    Moseley, M.E.3    Bammer, R.4
  • 49
    • 84924068900 scopus 로고    scopus 로고
    • Combination of a radial sequence for in vivo DTI of articular cartilage with an iterative model-based reconstruction
    • Raya J, Knoll F, Burcaw L, Milani S, Sodickson D, Block K. Combination of a radial sequence for in vivo DTI of articular cartilage with an iterative model-based reconstruction. Proc. Int. Soc. Magn. Reson. Med. 2014; 22: 152.
    • (2014) Proc. Int. Soc. Magn. Reson. Med. , vol.22 , pp. 152
    • Raya, J.1    Knoll, F.2    Burcaw, L.3    Milani, S.4    Sodickson, D.5    Block, K.6
  • 50
    • 0042092052 scopus 로고    scopus 로고
    • Nonlinear phase correction for navigated diffusion imaging
    • Miller KL, Pauly JM. Nonlinear phase correction for navigated diffusion imaging. Magn. Reson. Med. 2003; 50: 343-353.
    • (2003) Magn. Reson. Med. , vol.50 , pp. 343-353
    • Miller, K.L.1    Pauly, J.M.2
  • 51
    • 51849119588 scopus 로고    scopus 로고
    • The design of anisotropic diffusion phantoms for the validation of diffusion weighted magnetic resonance imaging
    • Fieremans E, Deene YD, Delputte S, Ozdemir MS, Achten E, Lemahieu I. The design of anisotropic diffusion phantoms for the validation of diffusion weighted magnetic resonance imaging. Phys. Med. Biol. 2008; 53: 5405-5419.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 5405-5419
    • Fieremans, E.1    Deene, Y.D.2    Delputte, S.3    Ozdemir, M.S.4    Achten, E.5    Lemahieu, I.6
  • 53
    • 0034666859 scopus 로고    scopus 로고
    • Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements
    • Holz M, Heil SR, Sacco A. Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements. Phys. Chem. Chem. Phys. 2000; 2: 4740-4742.
    • (2000) Phys. Chem. Chem. Phys. , vol.2 , pp. 4740-4742
    • Holz, M.1    Heil, S.R.2    Sacco, A.3
  • 54
    • 10044240735 scopus 로고    scopus 로고
    • Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging
    • Liu C, Bammer R, Kim DH, Moseley ME. Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging. Magn. Reson. Med. 2004; 52: 1388-1396.
    • (2004) Magn. Reson. Med. , vol.52 , pp. 1388-1396
    • Liu, C.1    Bammer, R.2    Kim, D.H.3    Moseley, M.E.4
  • 57
    • 0034767814 scopus 로고    scopus 로고
    • Diffusion-tensor MR imaging at 1.5 and 3.0 T: initial observations
    • Hunsche S, Moseley ME, Stoeter P, Hedehus M. Diffusion-tensor MR imaging at 1.5 and 3.0 T: initial observations. Radiology 2001; 221: 550-556.
    • (2001) Radiology , vol.221 , pp. 550-556
    • Hunsche, S.1    Moseley, M.E.2    Stoeter, P.3    Hedehus, M.4
  • 58
    • 33745832622 scopus 로고    scopus 로고
    • Quantitative diffusion tensor MR imaging of the brain: field strength related variance of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) scalars
    • Huisman TAGM, Loenneker T, Barta G, Bellemann ME, Hennig J, Fischer JE, Il'yasov KA. Quantitative diffusion tensor MR imaging of the brain: field strength related variance of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) scalars. Eur. Radiol. 2006; 16: 1651-1658.
    • (2006) Eur. Radiol. , vol.16 , pp. 1651-1658
    • Huisman, T.A.G.M.1    Loenneker, T.2    Barta, G.3    Bellemann, M.E.4    Hennig, J.5    Fischer, J.E.6    Il'yasov, K.A.7
  • 59
    • 77955672158 scopus 로고    scopus 로고
    • Diffusion tensor imaging of the brain in a healthy adult population: Normative values and measurement reproducibility at 3 T and 1.5 T
    • Brander A, Kataja A, Saastamoinen A, Ryymin P, Huhtala H, Ohman J, Soimakallio S, Dastidar P. Diffusion tensor imaging of the brain in a healthy adult population: Normative values and measurement reproducibility at 3 T and 1.5 T. Acta Radiol. 2010; 51: 800-807.
    • (2010) Acta Radiol. , vol.51 , pp. 800-807
    • Brander, A.1    Kataja, A.2    Saastamoinen, A.3    Ryymin, P.4    Huhtala, H.5    Ohman, J.6    Soimakallio, S.7    Dastidar, P.8
  • 61
    • 51449090553 scopus 로고    scopus 로고
    • Image reconstruction by regularized nonlinear inversion-joint estimation of coil sensitivities and image content
    • Uecker M, Hohage T, Block KT, Frahm J. Image reconstruction by regularized nonlinear inversion-joint estimation of coil sensitivities and image content. Magn. Reson. Med. 2008; 60: 674-682.
    • (2008) Magn. Reson. Med. , vol.60 , pp. 674-682
    • Uecker, M.1    Hohage, T.2    Block, K.T.3    Frahm, J.4
  • 62
    • 84903395655 scopus 로고    scopus 로고
    • iPiano: Inertial Proximal Algorithm for Non-convex Optimization
    • Ochs P, Chen Y, Brox T, Pock T. iPiano: Inertial Proximal Algorithm for Non-convex Optimization. SIAM J. Imaging Sci. 2014; 7: 1388-1419.
    • (2014) SIAM J. Imaging Sci. , vol.7 , pp. 1388-1419
    • Ochs, P.1    Chen, Y.2    Brox, T.3    Pock, T.4
  • 63
    • 84875902472 scopus 로고    scopus 로고
    • Total generalized variation in diffusion tensor imaging
    • Valkonen T, Bredies K, Knoll F. Total generalized variation in diffusion tensor imaging. SIAM J. Imaging Sci. 2013; 6: 487-525.
    • (2013) SIAM J. Imaging Sci. , vol.6 , pp. 487-525
    • Valkonen, T.1    Bredies, K.2    Knoll, F.3
  • 64
    • 0032835247 scopus 로고    scopus 로고
    • Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
    • Jones DK, Horsfield MA, Simmons A. Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn. Reson. Med. 1999; 42: 515-525.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 515-525
    • Jones, D.K.1    Horsfield, M.A.2    Simmons, A.3
  • 66
    • 84880511298 scopus 로고    scopus 로고
    • Design of multishell sampling schemes with uniform coverage in diffusion MRI
    • Caruyer E, Lenglet C, Sapiro G, Deriche R. Design of multishell sampling schemes with uniform coverage in diffusion MRI. Magn. Reson. Med. 2013; 69: 1534-1540.
    • (2013) Magn. Reson. Med. , vol.69 , pp. 1534-1540
    • Caruyer, E.1    Lenglet, C.2    Sapiro, G.3    Deriche, R.4
  • 67
    • 77955660153 scopus 로고    scopus 로고
    • MRI quantification of non-Gaussian water diffusion by kurtosis analysis
    • Jensen JH, Helpern JA. MRI quantification of non-Gaussian water diffusion by kurtosis analysis. NMR Biomed. 2010; 23: 698-710.
    • (2010) NMR Biomed. , vol.23 , pp. 698-710
    • Jensen, J.H.1    Helpern, J.A.2
  • 68
    • 84924034322 scopus 로고    scopus 로고
    • Accelerating diffusion kurtosis acquisition using SIR and model-based reconstruction
    • In, Milan, Italy ; : 2599.
    • Welsh CL, Hsu E, DiBella E. Accelerating diffusion kurtosis acquisition using SIR and model-based reconstruction. In Proc. Intl. Soc. Mag. Reson. Med., Milan, Italy 2014; 22: 2599.
    • (2014) Proc. Intl. Soc. Mag. Reson. Med. , vol.22
    • Welsh, C.L.1    Hsu, E.2    DiBella, E.3
  • 69
    • 0036158633 scopus 로고    scopus 로고
    • Relationships between diffusion tensor and q-space MRI
    • Basser PJ. Relationships between diffusion tensor and q-space MRI. Magn. Reson. Med. 2002; 47: 392-397.
    • (2002) Magn. Reson. Med. , vol.47 , pp. 392-397
    • Basser, P.J.1
  • 71
    • 10044249029 scopus 로고    scopus 로고
    • Q-ball imaging
    • Tuch DS. Q-ball imaging. Magn. Reson. Med. 2004; 52: 1358-1372.
    • (2004) Magn. Reson. Med. , vol.52 , pp. 1358-1372
    • Tuch, D.S.1
  • 72
    • 28444477694 scopus 로고    scopus 로고
    • Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
    • Wedeen VJ, Hagmann P, Tseng WYI, Reese TG, Weisskoff RM. Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging. Magn. Reson. Med. 2005; 54: 1377-1386.
    • (2005) Magn. Reson. Med. , vol.54 , pp. 1377-1386
    • Wedeen, V.J.1    Hagmann, P.2    Tseng, W.Y.I.3    Reese, T.G.4    Weisskoff, R.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.