메뉴 건너뛰기




Volumn 66, Issue 3, 2011, Pages 706-716

Fast MR parameter mapping using k-t principal component analysis

Author keywords

k t PCA; quantitative MRI; relaxometry; spin density quantification

Indexed keywords

DATA ACQUISITION; FUNCTIONS; MAPPING; NEURODEGENERATIVE DISEASES;

EID: 80051704692     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22826     Document Type: Article
Times cited : (88)

References (29)
  • 3
    • 0033045138 scopus 로고    scopus 로고
    • T1 and T2 in the brain of healthy subjects, patients with Parkinson disease, and patients with multiple system atrophy: Relation to iron content
    • Vymazal J, Righini A, Brooks RA, Canesi M, Mariani C, Leonardi M, Pezzoli G,. T1 and T2 in the brain of healthy subjects, patients with Parkinson disease, and patients with multiple system atrophy: relation to iron content. Radiology 1999; 211: 489-495. (Pubitemid 29206821)
    • (1999) Radiology , vol.211 , Issue.2 , pp. 489-495
    • Vymazal, J.1    Righini, A.2    Brooks, R.A.3    Canesi, M.4    Mariani, C.5    Leonardi, M.6    Pezzoli, G.7
  • 4
    • 23844436002 scopus 로고    scopus 로고
    • MR properties of excised neural tissue following experimentally induced demyelination
    • DOI 10.1002/nbm.951
    • Odrobina EE, Lam TY, Pun T, Midha R, Stanisz GJ,. MR properties of excised neural tissue following experimentally induced demyelination. NMR Biomed 2005; 18: 277-284. (Pubitemid 41158693)
    • (2005) NMR in Biomedicine , vol.18 , Issue.5 , pp. 277-284
    • Odrobina, E.E.1    Lam, T.Y.J.2    Pun, T.3    Midha, R.4    Stanisz, G.J.5
  • 5
    • 72649097424 scopus 로고    scopus 로고
    • A new window in multiple sclerosis pathology: Non-conventional quantitative magnetic resonance imaging outcomes
    • Zipp F,. A new window in multiple sclerosis pathology: non-conventional quantitative magnetic resonance imaging outcomes. J Neurol Sci 2009; 287 (Suppl 1): S24-29.
    • (2009) J Neurol Sci , vol.287 , Issue.SUPPL. 1
    • Zipp, F.1
  • 6
    • 49049099802 scopus 로고    scopus 로고
    • Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
    • Warntjes JB, Leinhard OD, West J, Lundberg P,. Rapid magnetic resonance quantification on the brain: optimization for clinical usage. Magn Reson Med 2008; 60: 320-329.
    • (2008) Magn Reson Med , vol.60 , pp. 320-329
    • Warntjes, J.B.1    Leinhard, O.D.2    West, J.3    Lundberg, P.4
  • 7
    • 67650077674 scopus 로고    scopus 로고
    • T1 mapping using spoiled FLASH-EPI hybrid sequences and varying flip angles
    • Preibisch C, Deichmann R,. T1 mapping using spoiled FLASH-EPI hybrid sequences and varying flip angles. Magn Reson Med 2009; 62: 240-246.
    • (2009) Magn Reson Med , vol.62 , pp. 240-246
    • Preibisch, C.1    Deichmann, R.2
  • 8
    • 12144277049 scopus 로고    scopus 로고
    • 2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2
    • DOI 10.1002/mrm.20314
    • Deoni SC, Peters TM, Rutt BK,. High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2. Magn Reson Med 2005; 53: 237-241. (Pubitemid 40110499)
    • (2005) Magnetic Resonance in Medicine , vol.53 , Issue.1 , pp. 237-241
    • Deoni, S.C.L.1    Peters, T.M.2    Rutt, B.K.3
  • 11
    • 9244237599 scopus 로고    scopus 로고
    • Towards a single-sequence neurologic magnetic resonance imaging examination: Multiple-contrast images from an IR TrueFISP experiment
    • DOI 10.1097/00004424-200412000-00008
    • Gulani V, Schmitt P, Griswold MA, Webb AG, Jakob PM,. Towards a single-sequence neurologic magnetic resonance imaging examination: multiple-contrast images from an IR TrueFISP experiment. Invest Radiol 2004; 39: 767-774. (Pubitemid 39552437)
    • (2004) Investigative Radiology , vol.39 , Issue.12 , pp. 767-774
    • Gulani, V.1    Schmitt, P.2    Griswold, M.A.3    Webb, A.G.4    Jakob, P.M.5
  • 12
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • DOI 10.1002/mrm.1113
    • Kellman P, Epstein FH, McVeigh ER,. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001; 45: 846-852. (Pubitemid 32402027)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.5 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 13
    • 16444385871 scopus 로고    scopus 로고
    • Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA)
    • DOI 10.1002/mrm.20430
    • Breuer FA, Kellman P, Griswold MA, Jakob PM,. Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA). Magn Reson Med 2005; 53: 981-985. (Pubitemid 40478451)
    • (2005) Magnetic Resonance in Medicine , vol.53 , Issue.4 , pp. 981-985
    • Breuer, F.A.1    Kellman, P.2    Griswold, M.A.3    Jakob, P.M.4
  • 14
    • 27644503134 scopus 로고    scopus 로고
    • K-t GRAPPA: A k-space implementation for dynamic MRI with high reduction factor
    • DOI 10.1002/mrm.20641
    • Huang F, Akao J, Vijayakumar S, Duensing GR, Limkeman M,. k-t GRAPPA: a k-space implementation for dynamic MRI with high reduction factor. Magn Reson Med 2005; 54: 1172-1184. (Pubitemid 41567197)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.5 , pp. 1172-1184
    • Huang, F.1    Akao, J.2    Vijayakumar, S.3    Duensing, G.R.4    Limkeman, M.5
  • 15
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI With High Frame Rate Exploiting Spatiotemporal Correlations
    • DOI 10.1002/mrm.10611
    • Tsao J, Boesiger P, Pruessmann KP,. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003; 50: 1031-1042. (Pubitemid 37356583)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.5 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 16
    • 69449097366 scopus 로고    scopus 로고
    • K-t PCA: Temporally constrained k-t BLAST reconstruction using principal component analysis
    • Pedersen H, Kozerke S, Ringgaard S, Nehrke K, Kim WY,. k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis. Magn Reson Med 2009; 62: 706-716.
    • (2009) Magn Reson Med , vol.62 , pp. 706-716
    • Pedersen, H.1    Kozerke, S.2    Ringgaard, S.3    Nehrke, K.4    Kim, W.Y.5
  • 23
    • 70449371825 scopus 로고    scopus 로고
    • SSFP signal with finite RF pulses
    • Bieri O, Scheffler K,. SSFP signal with finite RF pulses. Magn Reson Med 2009; 62: 1232-1241.
    • (2009) Magn Reson Med , vol.62 , pp. 1232-1241
    • Bieri, O.1    Scheffler, K.2
  • 24
    • 79951840310 scopus 로고    scopus 로고
    • Influence of MT effects on T(2) quantification with 3D balanced steady-state free precession imaging
    • Crooijmans HJ, Gloor M, Bieri O, Scheffler K,. Influence of MT effects on T(2) quantification with 3D balanced steady-state free precession imaging. Magn Reson Med 2011; 65: 195-201.
    • (2011) Magn Reson Med , vol.65 , pp. 195-201
    • Crooijmans, H.J.1    Gloor, M.2    Bieri, O.3    Scheffler, K.4
  • 25
    • 79251573151 scopus 로고    scopus 로고
    • Single-shot proton density, T1 and T2 quantification with radial IR TrueFISP: Effect of magnetization transfer and long RF pulses
    • Ehses P, Gulani V, Yutzy S, Seiberlich N, Jakob PM, Griswold MA,. Single-shot proton density, T1 and T2 quantification with radial IR TrueFISP: effect of magnetization transfer and long RF pulses. Proc Intl Soc Mag Reson Med 2010; 18: 2969.
    • (2010) Proc Intl Soc Mag Reson Med , vol.18 , pp. 2969
    • Ehses, P.1    Gulani, V.2    Yutzy, S.3    Seiberlich, N.4    Jakob, P.M.5    Griswold, M.A.6
  • 26
    • 80051701107 scopus 로고    scopus 로고
    • Flip angle sensitivity in IR-trueFISP T1 and T2 mapping
    • Newbould R, Bammer R,. Flip angle sensitivity in IR-trueFISP T1 and T2 mapping. Proc Intl Soc Mag Reson Med 2005; 13: 2191.
    • (2005) Proc Intl Soc Mag Reson Med , vol.13 , pp. 2191
    • Newbould, R.1    Bammer, R.2
  • 28
    • 80051698245 scopus 로고    scopus 로고
    • Rapid high-resolution relaxation time and spin-density quantification using a modified segmented IR-trueFISP sequence
    • Breuer F, Darji N, Ehses P, Jakob PM, Blaimer M,. Rapid high-resolution relaxation time and spin-density quantification using a modified segmented IR-trueFISP sequence. Proc Eur Soc Mag Reson Med Biol 2009; 25: 183.
    • (2009) Proc Eur Soc Mag Reson Med Biol , vol.25 , pp. 183
    • Breuer, F.1    Darji, N.2    Ehses, P.3    Jakob, P.M.4    Blaimer, M.5
  • 29
    • 77955183886 scopus 로고    scopus 로고
    • Accelerated MR parameter mapping using compressed sensing with model-based sparsifiying transform
    • Doneva M, Senegas J, Börnert P, Eggers H, Mertins A,. Accelerated MR parameter mapping using compressed sensing with model-based sparsifiying transform. Proc Intl Soc Mag Reson Med 2009; 17: 385.
    • (2009) Proc Intl Soc Mag Reson Med , vol.17 , pp. 385
    • Doneva, M.1    Senegas, J.2    Börnert, P.3    Eggers, H.4    Mertins, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.