메뉴 건너뛰기




Volumn 90, Issue 10, 2014, Pages 936-942

Design and characterization of an economical 192Ir hemi-brain small animal irradiator

Author keywords

hemi brain; Iridium 192 HDR; Small animal irradiator

Indexed keywords

IRIDIUM 192; TUNGSTEN; IRIDIUM;

EID: 84921812343     PISSN: 09553002     EISSN: 13623095     Source Type: Journal    
DOI: 10.3109/09553002.2014.922719     Document Type: Article
Times cited : (3)

References (14)
  • 2
    • 79957598195 scopus 로고    scopus 로고
    • Dosimetric calibration and characterization for experimental mouse thoracic irradiation using orthovoltage X rays
    • Arndt CD, Wang IZ, Saito NG, Podgorsak MB. 2011. Dosimetric calibration and characterization for experimental mouse thoracic irradiation using orthovoltage X rays. Radiat Res 175:784-789.
    • (2011) Radiat Res , vol.175 , pp. 784-789
    • Arndt, C.D.1    Wang, I.Z.2    Saito, N.G.3    Podgorsak, M.B.4
  • 3
    • 78149484465 scopus 로고    scopus 로고
    • The water equivalence of solid phantoms for low energy photon beams
    • Hill R, Kuncic Z, Baldock C. 2010. The water equivalence of solid phantoms for low energy photon beams. Medical Phys 37:4355.
    • (2010) Medical Phys , vol.37 , pp. 4355
    • Hill, R.1    Kuncic, Z.2    Baldock, C.3
  • 5
    • 84867286606 scopus 로고    scopus 로고
    • An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan
    • Lewis D, Micke A, Yu X, Chan MF. 2012. An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan. Med Phys 39:6339-6350.
    • (2012) Med Phys , vol.39 , pp. 6339-6350
    • Lewis, D.1    Micke, A.2    Yu, X.3    Chan, M.F.4
  • 6
    • 78149480566 scopus 로고    scopus 로고
    • Enhanced epidermal dose caused by localized electron contamination from lead cutouts used in kilovoltage radiotherapy
    • Lye JE, Butler DJ, Webb DV. 2010. Enhanced epidermal dose caused by localized electron contamination from lead cutouts used in kilovoltage radiotherapy. Med Phys 37:3935.
    • (2010) Med Phys , vol.37 , pp. 3935
    • Lye, J.E.1    Butler, D.J.2    Webb, D.V.3
  • 7
    • 84867304145 scopus 로고    scopus 로고
    • Energy dependence of the new Gafchromic EBT3 film:Dose response curves for 50 KV, 6 and 15 MV X-ray beams
    • Massillon-JL G. 2012. Energy dependence of the new Gafchromic EBT3 film:dose response curves for 50 KV, 6 and 15 MV X-ray beams. Int J Med Phys, Clin Engineer Radiat Oncol 1:60-65.
    • (2012) Int J Med Phys, Clin Engineer Radiat Oncol , vol.1 , pp. 60-65
    • Massillon-Jl, G.1
  • 9
    • 84878939305 scopus 로고    scopus 로고
    • Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE(R) radiochromic plastic
    • Palmer AL, Di Pietro P, Alobaidli S, Issa F, Doran S, Bradley D, Nisbet A. 2013. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE(R) radiochromic plastic. Med Phys 40:061707.
    • (2013) Med Phys , vol.40 , pp. 061707
    • Palmer, A.L.1    Di Pietro, P.2    Alobaidli, S.3    Issa, F.4    Doran, S.5    Bradley, D.6    Nisbet, A.7
  • 10
    • 84868534543 scopus 로고    scopus 로고
    • TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
    • Perl J, Shin J, Schumann J, Faddegon B, Paganetti H. 2012. TOPAS: An innovative proton Monte Carlo platform for research and clinical applications. Med Phys 39:6818-6837.
    • (2012) Med Phys , vol.39 , pp. 6818-6837
    • Perl, J.1    Shin, J.2    Schumann, J.3    Faddegon, B.4    Paganetti, H.5
  • 11
    • 0024986488 scopus 로고
    • Surface dose in intracavitary orthovoltage radiotherapy
    • Podgorsak MB. 1990. Surface dose in intracavitary orthovoltage radiotherapy. Med Phys 17:635.
    • (1990) Med Phys , vol.17 , pp. 635
    • Podgorsak, M.B.1
  • 13


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.