메뉴 건너뛰기




Volumn 37, Issue 8, 2010, Pages 4355-4363

The water equivalence of solid phantoms for low energy photon beams

Author keywords

kilovoltage x rays; Monte Carlo; solid phantoms; water equivalence

Indexed keywords

BACKSCATTERING; DOSIMETRY; MONTE CARLO METHODS; PARTICLE BEAMS; PHOTOELECTRONS; PHOTONS; POLYSTYRENES; X RAYS;

EID: 78149484465     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3462558     Document Type: Article
Times cited : (90)

References (41)
  • 1
    • 0032906411 scopus 로고    scopus 로고
    • An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry
    • M. Allahverdi, A. Nisbet, and D. I. Thwaites, "An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry," Phys. Med. Biol. 44, 1125-1132 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1125-1132
    • Allahverdi, M.1    Nisbet, A.2    Thwaites, D.I.3
  • 3
    • 0018125662 scopus 로고
    • Tissue substitutes in experimental radiation physics
    • D. R. White, "Tissue substitutes in experimental radiation physics," Med. Phys. 5, 467-479 (1978).
    • (1978) Med. Phys. , vol.5 , pp. 467-479
    • White, D.R.1
  • 4
    • 0028566142 scopus 로고
    • A comparative study of dosimetric properties of Plastic Water and Solid Water in brachytherapy applications
    • A. S. Meigooni, Z. Li, V. Mishra, and J. F. Williamson, "A comparative study of dosimetric properties of Plastic Water and Solid Water in brachytherapy applications," Med. Phys. 21, 1983-1987 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1983-1987
    • Meigooni, A.S.1    Li, Z.2    Mishra, V.3    Williamson, J.F.4
  • 5
    • 2342465468 scopus 로고    scopus 로고
    • The radial dose function of low-energy brachytherapy seeds in different solid phantoms: Comparison between calculations with the EGSnrc and MCNP4C Monte Carlo codes and measurements
    • B. Reniers, F. Verhaegen, and S. Vynckier, "The radial dose function of low-energy brachytherapy seeds in different solid phantoms: Comparison between calculations with the EGSnrc and MCNP4C Monte Carlo codes and measurements," Phys. Med. Biol. 49, 1569-1582 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 1569-1582
    • Reniers, B.1    Verhaegen, F.2    Vynckier, S.3
  • 7
    • 27144551316 scopus 로고    scopus 로고
    • A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams
    • R. Hill, L. Holloway, and C. Baldock, "A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams," Phys. Med. Biol. 50, N331-N344 (2005).
    • (2005) Phys. Med. Biol. , vol.50
    • Hill, R.1    Holloway, L.2    Baldock, C.3
  • 8
    • 20044379949 scopus 로고    scopus 로고
    • Addendum to the IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL)
    • R. J. Aukett, J. E. Burns, A. G. Greener, R. M. Harrison, C. Moretti, A. E. Nahum, and K. E. Rosser, "Addendum to the IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL)," Phys. Med. Biol. 50, 2739-2748 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 2739-2748
    • Aukett, R.J.1    Burns, J.E.2    Greener, A.G.3    Harrison, R.M.4    Moretti, C.5    Nahum, A.E.6    Rosser, K.E.7
  • 9
    • 0029846001 scopus 로고    scopus 로고
    • The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential). Institution of Physics and Engineering in Medicine and Biology
    • S. C. Klevenhagen, R. J. Aukett, R. M. Harrison, C. J. Moretti, A. E. Nahum, and K. E. Rosser, "The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential). Institution of Physics and Engineering in Medicine and Biology," Phys. Med. Biol. 41, 2605-2625 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2605-2625
    • Klevenhagen, S.C.1    Aukett, R.J.2    Harrison, R.M.3    Moretti, C.J.4    Nahum, A.E.5    Rosser, K.E.6
  • 10
  • 11
    • 0003682469 scopus 로고
    • Tissue substitutes in radiation dosimetry and measurement
    • International Commission on Radiation Units and Measurements
    • International Commission on Radiation Units and Measurements, "Tissue substitutes in radiation dosimetry and measurement," ICRU Report No. 44, 1989.
    • (1989) ICRU Report No. 44
  • 12
    • 0022405152 scopus 로고
    • Polyethylene-based water-equivalent phantom material for x-ray dosimetry at tube voltages from 10 to 100 kV
    • K. P. Hermann, L. Geworski, M. Muth, and D. Harder, "Polyethylene- based water-equivalent phantom material for x-ray dosimetry at tube voltages from 10 to 100 kV," Phys. Med. Biol. 30, 1195-1200 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 1195-1200
    • Hermann, K.P.1    Geworski, L.2    Muth, M.3    Harder, D.4
  • 13
    • 48849108249 scopus 로고    scopus 로고
    • Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements
    • R. F. Hill, S. Brown, and C. Baldock, "Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements," Radiat. Meas. 43, 1258-1264 (2008).
    • (2008) Radiat. Meas. , vol.43 , pp. 1258-1264
    • Hill, R.F.1    Brown, S.2    Baldock, C.3
  • 15
    • 9944250575 scopus 로고    scopus 로고
    • Measurements of the x-ray linear attenuation coefficient for low atomic number materials at energies 32-66 and 140 keV
    • S. M. Midgley, "Measurements of the x-ray linear attenuation coefficient for low atomic number materials at energies 32-66 and 140 keV," Radiat. Phys. Chem. 72, 525-535 (2005).
    • (2005) Radiat. Phys. Chem. , vol.72 , pp. 525-535
    • Midgley, S.M.1
  • 16
    • 0029086205 scopus 로고
    • Considerations for superficial photon dosimetry
    • R. L. Stern and H. D. Kubo, "Considerations for superficial photon dosimetry," Med. Phys. 22, 1469-1470 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1469-1470
    • Stern, R.L.1    Kubo, H.D.2
  • 18
    • 45949110209 scopus 로고    scopus 로고
    • Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT
    • S. Brown, D. L. Bailey, K. Willowson, and C. Baldock, "Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT," Appl. Radiat. Isot. 66, 1206-1212 (2008).
    • (2008) Appl. Radiat. Isot. , vol.66 , pp. 1206-1212
    • Brown, S.1    Bailey, D.L.2    Willowson, K.3    Baldock, C.4
  • 19
    • 31844441847 scopus 로고    scopus 로고
    • Assessing the effect of electron density in photon dose calculations
    • J. Seco and P. M. Evans, "Assessing the effect of electron density in photon dose calculations," Med. Phys. 33, 540-552 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 540-552
    • Seco, J.1    Evans, P.M.2
  • 20
    • 0023717249 scopus 로고
    • A comparison of solid phantoms with water for dosimetry of 125I brachytherapy sources
    • A. S. Meigooni, J. A. Meli, and R. Nath, "A comparison of solid phantoms with water for dosimetry of 125I brachytherapy sources," Med. Phys. 15, 695-701 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 695-701
    • Meigooni, A.S.1    Meli, J.A.2    Nath, R.3
  • 21
    • 0033844824 scopus 로고    scopus 로고
    • A comparison of measured and calculated photon backscatter from dosimeter calibration phantoms
    • D. A. Schauer, J. R. Cassata, and J. J. King, "A comparison of measured and calculated photon backscatter from dosimeter calibration phantoms," Radiat. Prot. Dosim. 88, 319-321 (2000).
    • (2000) Radiat. Prot. Dosim. , vol.88 , pp. 319-321
    • Schauer, D.A.1    Cassata, J.R.2    King, J.J.3
  • 22
    • 45149106870 scopus 로고    scopus 로고
    • Variations in backscatter observed in PMMA whole-body dosimetry slab phantoms
    • S. O. Schwahn and T. F. Gesell, "Variations in backscatter observed in PMMA whole-body dosimetry slab phantoms," Radiat. Prot. Dosim. 128, 375-381 (2008).
    • (2008) Radiat. Prot. Dosim. , vol.128 , pp. 375-381
    • Schwahn, S.O.1    Gesell, T.F.2
  • 23
    • 0031408420 scopus 로고    scopus 로고
    • Determination of photon backscatter from several calibration phantoms
    • R. J. Traub, J. C. McDonald, and M. K. Murphy, "Determination of photon backscatter from several calibration phantoms," Radiat. Prot. Dosim. 74, 13-20 (1997).
    • (1997) Radiat. Prot. Dosim. , vol.74 , pp. 13-20
    • Traub, R.J.1    McDonald, J.C.2    Murphy, M.K.3
  • 24
    • 0020072640 scopus 로고
    • Measurements of diagnostic x-ray backscatter by a novel ion chamber method
    • L. Stanton, S. D. Brattelli, J. L. Day, R. E. Stanton, and T. Villafana, "Measurements of diagnostic x-ray backscatter by a novel ion chamber method," Med. Phys. 9, 121-130 (1982).
    • (1982) Med. Phys. , vol.9 , pp. 121-130
    • Stanton, L.1    Brattelli, S.D.2    Day, J.L.3    Stanton, R.E.4    Villafana, T.5
  • 25
    • 76149125204 scopus 로고    scopus 로고
    • An investigation of backscatter factors for kilovoltage x-rays: A comparison between Monte Carlo simulations and Gafchromic EBT film measurements
    • J. Kim, R. Hill, E. C. Mackonis, and Z. Kuncic, "An investigation of backscatter factors for kilovoltage x-rays: A comparison between Monte Carlo simulations and Gafchromic EBT film measurements," Phys. Med. Biol. 55, 783-797 (2010).
    • (2010) Phys. Med. Biol. , vol.55 , pp. 783-797
    • Kim, J.1    Hill, R.2    Mackonis, E.C.3    Kuncic, Z.4
  • 26
    • 0344267664 scopus 로고    scopus 로고
    • Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams
    • C. M. Ma and J. P. Seuntjens, "Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams," Phys. Med. Biol. 44, 131-143 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 131-143
    • Ma, C.M.1    Seuntjens, J.P.2
  • 27
    • 33745501013 scopus 로고    scopus 로고
    • Fifty years of Monte Carlo simulations for medical physics
    • D. W. O. Rogers, "Fifty years of Monte Carlo simulations for medical physics," Phys. Med. Biol. 51, R287-R301 (2006).
    • (2006) Phys. Med. Biol. , vol.51
    • Rogers, D.W.O.1
  • 28
    • 65249160230 scopus 로고    scopus 로고
    • Overview of physical interaction models for photon and electron transport used in Monte Carlo codes
    • F. Salvat and J. M. Fernandez-Varea, "Overview of physical interaction models for photon and electron transport used in Monte Carlo codes," Metrologia 46, S112-S138 (2009).
    • (2009) Metrologia , vol.46
    • Salvat, F.1    Fernandez-Varea, J.M.2
  • 29
    • 33847395287 scopus 로고    scopus 로고
    • Dose distribution in water for monoenergetic photon point sources in the energy range of interest in brachytherapy: Monte Carlo simulations with PENELOPE and GEANT4
    • J. F. Almansa, R. Guerrero, F. M. O. Al-Dweri, M. Anguiano, and A. M. Lallena, "Dose distribution in water for monoenergetic photon point sources in the energy range of interest in brachytherapy: Monte Carlo simulations with PENELOPE and GEANT4," Radiat. Phys. Chem. 76, 766-773 (2007).
    • (2007) Radiat. Phys. Chem. , vol.76 , pp. 766-773
    • Almansa, J.F.1    Guerrero, R.2    Al-Dweri, F.M.O.3    Anguiano, M.4    Lallena, A.M.5
  • 30
    • 1142287542 scopus 로고    scopus 로고
    • Benchmark of PENELOPE code for low-energy photon transport: Dose comparison with MCNP4 and EGS4
    • S. J. Ye, I. A. Brezovich, P. Pareek, and S. A. Naqvi, "Benchmark of PENELOPE code for low-energy photon transport: Dose comparison with MCNP4 and EGS4," Phys. Med. Biol. 49, 387-397 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 387-397
    • Ye, S.J.1    Brezovich, I.A.2    Pareek, P.3    Naqvi, S.A.4
  • 31
    • 0034451289 scopus 로고    scopus 로고
    • Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations
    • H. Zaidi, "Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations," IEEE Trans. Nucl. Sci. 47, 2722-2735 (2000).
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 2722-2735
    • Zaidi, H.1
  • 36
    • 0029113276 scopus 로고
    • How water equivalent are water-equivalent solid materials for output calibration of photon and electron beams?
    • V. M. Tello, R. C. Tailor, and W. F. Hanson, "How water equivalent are water-equivalent solid materials for output calibration of photon and electron beams?," Med. Phys. 22, 1177-1189 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1177-1189
    • Tello, V.M.1    Tailor, R.C.2    Hanson, W.F.3
  • 37
    • 0006547456 scopus 로고
    • Electron beams with energies between 1 and 50 MeV
    • International Commission on Radiation Units and Measurements
    • International Commission on Radiation Units and Measurements, "Electron beams with energies between 1 and 50 MeV," ICRU Report No. 35, 1984.
    • (1984) ICRU Report No. 35
  • 38
    • 0018399326 scopus 로고
    • Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector
    • R. Birch and M. Marshall, "Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector," Phys. Med. Biol. 24, 505 (1979).
    • (1979) Phys. Med. Biol. , vol.24 , pp. 505
    • Birch, R.1    Marshall, M.2
  • 39
    • 58149269275 scopus 로고    scopus 로고
    • Study of the formalism used to determine the absorbed dose for low-energy x-ray beams
    • U. Chica, M. Anguiano, and A. M. Lallena, "Study of the formalism used to determine the absorbed dose for low-energy x-ray beams," Phys. Med. Biol. 53, 6963-6977 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 6963-6977
    • Chica, U.1    Anguiano, M.2    Lallena, A.M.3
  • 40
    • 67349100670 scopus 로고    scopus 로고
    • Benchmark of PENELOPE for low and medium energy x-rays
    • U. Chica, M. Anguiano, and A. M. Lallena, "Benchmark of PENELOPE for low and medium energy x-rays," Phys. Medica 25, 51-57 (2009).
    • (2009) Phys. Medica , vol.25 , pp. 51-57
    • Chica, U.1    Anguiano, M.2    Lallena, A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.