메뉴 건너뛰기




Volumn 73, Issue 1, 2015, Pages 21-30

Radiofrequency pulse design for the selective excitation of dissolved 129Xe

Author keywords

Composite pulse; Dissolved xenon; Hyperpolarized; Lung; Selective excitation

Indexed keywords

FREQUENCY RESPONSE; MAGNETIC RESONANCE SPECTROSCOPY; NUMERICAL METHODS; PULSE WIDTH MODULATION; SCANNING; VOLTAGE CONTROL;

EID: 84919872351     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.25089     Document Type: Article
Times cited : (20)

References (25)
  • 1
    • 0031480383 scopus 로고    scopus 로고
    • Spin-exchange optical pumping of noble-gas nuclei
    • Walker TG, Happer W. Spin-exchange optical pumping of noble-gas nuclei. Rev Mod Phys 1997;69:629.
    • (1997) Rev Mod Phys , vol.69 , pp. 629
    • Walker, T.G.1    Happer, W.2
  • 2
    • 0036923779 scopus 로고    scopus 로고
    • High capacity production of >65% spin polarized xenon-129 for NMR spectroscopy and imaging
    • Zook AL, Adhyaru BB, Bowers CR. High capacity production of >65% spin polarized xenon-129 for NMR spectroscopy and imaging. J Magn Reson 2002;159:175-182.
    • (2002) J Magn Reson , vol.159 , pp. 175-182
    • Zook, A.L.1    Adhyaru, B.B.2    Bowers, C.R.3
  • 5
    • 77957880663 scopus 로고    scopus 로고
    • Hyperpolarized 129Xe MR imaging of alveolar gas uptake in humans
    • Cleveland ZI, Cofer GP, Metz G, et al. Hyperpolarized 129Xe MR imaging of alveolar gas uptake in humans. PLoS One 2010;5:e12192.
    • (2010) PLoS One , vol.5 , pp. e12192
    • Cleveland, Z.I.1    Cofer, G.P.2    Metz, G.3
  • 8
    • 0033624909 scopus 로고    scopus 로고
    • Hyperpolarized 129Xe NMR as a probe for blood oxygenation
    • Wolber J, Cherubini A, Leach MO, Bifone A. Hyperpolarized 129Xe NMR as a probe for blood oxygenation. Magn Reson Med 2000;43:491-496.
    • (2000) Magn Reson Med , vol.43 , pp. 491-496
    • Wolber, J.1    Cherubini, A.2    Leach, M.O.3    Bifone, A.4
  • 10
    • 84859108157 scopus 로고    scopus 로고
    • Multiple-exchange-time xenon polarization transfer contrast (MXTC) MRI: Initial results in animals and healthy volunteers
    • Dregely I, Ruset IC, Mata JF, et al. Multiple-exchange-time xenon polarization transfer contrast (MXTC) MRI: initial results in animals and healthy volunteers. Magn Reson Med 2012;67:943-953.
    • (2012) Magn Reson Med , vol.67 , pp. 943-953
    • Dregely, I.1    Ruset, I.C.2    Mata, J.F.3
  • 11
    • 0345600051 scopus 로고    scopus 로고
    • Characterization of diffusing capacity and perfusion of the rat lung in a lipopolysaccaride disease model using hyperpolarized 129Xe
    • Månsson S, Wolber J, Driehuys B, Wollmer P, Golman K. Characterization of diffusing capacity and perfusion of the rat lung in a lipopolysaccaride disease model using hyperpolarized 129Xe. Magn Reson Med 2003;50:1170-1179.
    • (2003) Magn Reson Med , vol.50 , pp. 1170-1179
    • Månsson, S.1    Wolber, J.2    Driehuys, B.3    Wollmer, P.4    Golman, K.5
  • 12
    • 0031894007 scopus 로고    scopus 로고
    • The blood-gas partition coefficient of xenon may be lower than generally accepted
    • Goto T, Suwa K, Uezono S, Ichinose F, Uchiyama M, Morita S. The blood-gas partition coefficient of xenon may be lower than generally accepted. Br J Anaesth 1998;80:255-256.
    • (1998) Br J Anaesth , vol.80 , pp. 255-256
    • Goto, T.1    Suwa, K.2    Uezono, S.3    Ichinose, F.4    Uchiyama, M.5    Morita, S.6
  • 14
    • 77955927715 scopus 로고    scopus 로고
    • Effects of in-pulse transverse relaxation in 3D ultrashort echo time sequences: Analytical derivation, comparison to numerical simulation and experimental application at 3 T
    • Springer F, Steidle G, Martirosian P, Claussen CD, Schick F. Effects of in-pulse transverse relaxation in 3D ultrashort echo time sequences: analytical derivation, comparison to numerical simulation and experimental application at 3 T. J Magn Reson 2010;206:88-96.
    • (2010) J Magn Reson , vol.206 , pp. 88-96
    • Springer, F.1    Steidle, G.2    Martirosian, P.3    Claussen, C.D.4    Schick, F.5
  • 15
    • 0033623752 scopus 로고    scopus 로고
    • NMR of hyperpolarized 129Xe in the canine chest: Spectral dynamics during a breath-hold
    • Ruppert K, Brookeman JR, Hagspiel KD, Driehuys B, Mugler JP. NMR of hyperpolarized 129Xe in the canine chest: spectral dynamics during a breath-hold. NMR Biomed 2000;13:220-228.
    • (2000) NMR Biomed , vol.13 , pp. 220-228
    • Ruppert, K.1    Brookeman, J.R.2    Hagspiel, K.D.3    Driehuys, B.4    Mugler, J.P.5
  • 16
    • 0026116321 scopus 로고
    • Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]
    • Pauly J, Le Roux P, Nishimura D, Macovski A. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]. IEEE Trans Med Imaging 1991;10:53-65.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 53-65
    • Pauly, J.1    Le Roux, P.2    Nishimura, D.3    Macovski, A.4
  • 17
    • 33846799432 scopus 로고    scopus 로고
    • Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerations
    • Tyler DJ, Robson MD, Henkelman RM, Young IR, Bydder GM. Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: technical considerations. J Magn Reson Imaging 2007;25:279-289.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 279-289
    • Tyler, D.J.1    Robson, M.D.2    Henkelman, R.M.3    Young, I.R.4    Bydder, G.M.5
  • 18
    • 49249151634 scopus 로고
    • NMR population inversion using a composite pulse
    • Levitt MH, Freeman R. NMR population inversion using a composite pulse. J Magn Reson (1969) 1979;33:473-476.
    • (1969) J Magn Reson , vol.33 , pp. 473-476
    • Levitt, M.H.1    Freeman, R.2
  • 19
    • 0000488661 scopus 로고
    • Matrix treatment of nuclear induction
    • Jaynes ET. Matrix treatment of nuclear induction. Phys Rev 1955;98:1099-1105.
    • (1955) Phys Rev , vol.98 , pp. 1099-1105
    • Jaynes, E.T.1
  • 24
    • 84884241628 scopus 로고    scopus 로고
    • Probing the regional distribution of pulmonary gas-exchange through single-breath, gasand dissolved-phase 129Xe MR imaging
    • Kaushik SS, Freeman MS, Cleveland ZI, et al. Probing the regional distribution of pulmonary gas-exchange through single-breath, gasand dissolved-phase 129Xe MR imaging. J Appl Physiol 2013;115:850-860.
    • (2013) J Appl Physiol , vol.115 , pp. 850-860
    • Kaushik, S.S.1    Freeman, M.S.2    Cleveland, Z.I.3
  • 25
    • 0026597519 scopus 로고
    • Effects of RF amplifier distortion on selective excitation and their correction by prewarping
    • Chan F, Pauly J, Macovski A. Effects of RF amplifier distortion on selective excitation and their correction by prewarping. Magn Reson Med 1992;23:224-238.
    • (1992) Magn Reson Med , vol.23 , pp. 224-238
    • Chan, F.1    Pauly, J.2    Macovski, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.