메뉴 건너뛰기




Volumn 206, Issue 1, 2010, Pages 88-96

Effects of in-pulse transverse relaxation in 3D ultrashort echo time sequences: Analytical derivation, comparison to numerical simulation and experimental application at 3 T

Author keywords

Ernst equation for fast spoiled gradient echo sequences; In pulse relaxation effects; Measurement of longitudinal relaxation time; Ultrashort echo time imaging; UTE

Indexed keywords

BLOCH EQUATION; BONY STRUCTURES; DERIVED DATA; ECHO SIGNALS; ECHO TIME; EXCITATION PULSE; EXPERIMENTAL APPLICATION; FAST SIGNAL; FLIP ANGLE; FREE RELAXATION; GRADIENT ECHO SEQUENCES; LONGITUDINAL RELAXATION TIME; MR SCANNERS; NEW APPROACHES; NUMERICAL RESULTS; NUMERICAL SIMULATION; POLYMERIC MATERIAL; PULSE DURATIONS; RELAXATION EFFECT; RUNGE-KUTTA; SOLID MATERIAL; STEADY STATE SIGNAL; TRANSVERSE MAGNETIZATION; TRANSVERSE RELAXATION; TRANSVERSE RELAXATION TIME; UTE; WHOLE-BODY;

EID: 77955927715     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2010.06.010     Document Type: Article
Times cited : (25)

References (26)
  • 1
    • 33751368661 scopus 로고    scopus 로고
    • Clinical ultrashort echo time imaging of bone and other connective tissues
    • M.D. Robson, and G.M. Bydder Clinical ultrashort echo time imaging of bone and other connective tissues NMR Biomed. 19 2006 765 780
    • (2006) NMR Biomed. , vol.19 , pp. 765-780
    • Robson, M.D.1    Bydder, G.M.2
  • 3
    • 33846799432 scopus 로고    scopus 로고
    • Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerations
    • D.J. Tyler, M.D. Robson, R.M. Henkelman, I.R. Young, and G.M. Bydder Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: technical considerations J. Magn. Reson. Imag. 25 2007 279 289
    • (2007) J. Magn. Reson. Imag. , vol.25 , pp. 279-289
    • Tyler, D.J.1    Robson, M.D.2    Henkelman, R.M.3    Young, I.R.4    Bydder, G.M.5
  • 5
    • 66149150655 scopus 로고    scopus 로고
    • Magnetization transfer contrast imaging in bovine human cortical bone applying an ultrashort echo time sequence at 3 T
    • F. Springer, P. Martirosian, J. Machann, N.F. Schwenzer, C.D. Claussen, and F. Schick Magnetization transfer contrast imaging in bovine human cortical bone applying an ultrashort echo time sequence at 3 T Magn. Reson. Med. 61 2009 1040 1048
    • (2009) Magn. Reson. Med. , vol.61 , pp. 1040-1048
    • Springer, F.1    Martirosian, P.2    MacHann, J.3    Schwenzer, N.F.4    Claussen, C.D.5    Schick, F.6
  • 8
    • 33646447508 scopus 로고    scopus 로고
    • Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    • J. Rahmer, P. Bornert, J. Groen, and C. Bos Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling Magn. Reson. Med. 55 2006 1075 1082
    • (2006) Magn. Reson. Med. , vol.55 , pp. 1075-1082
    • Rahmer, J.1    Bornert, P.2    Groen, J.3    Bos, C.4
  • 9
    • 40049083116 scopus 로고    scopus 로고
    • Two-dimensional ultrashort echo time imaging using a spiral trajectory
    • J. Du, M. Bydder, A.M. Takahashi, and C.B. Chung Two-dimensional ultrashort echo time imaging using a spiral trajectory Magn. Reson. Imag. 26 2008 304 312 Epub 2007 Dec 2021
    • (2008) Magn. Reson. Imag. , vol.26 , pp. 304-312
    • Du, J.1    Bydder, M.2    Takahashi, A.M.3    Chung, C.B.4
  • 13
    • 0027337730 scopus 로고
    • MRI and determination of T1 and T2 of solid polymers using a 1.5 T whole-body imager
    • S. Widmaier, W.I. Jung, K. Pfeffer, M. Pfeffer, and O. Lutz MRI and determination of T1 and T2 of solid polymers using a 1.5 T whole-body imager Magn. Reson. Imag. 11 1993 733 737
    • (1993) Magn. Reson. Imag. , vol.11 , pp. 733-737
    • Widmaier, S.1    Jung, W.I.2    Pfeffer, K.3    Pfeffer, M.4    Lutz, O.5
  • 14
    • 0027453763 scopus 로고
    • The use of power images to perform quantitative analysis on low SNR MR Images
    • A.J. Miller, and P.M. Joseph The use of power images to perform quantitative analysis on low SNR MR Images Magn. Reson. Imag. 11 1993 1051 1056
    • (1993) Magn. Reson. Imag. , vol.11 , pp. 1051-1056
    • Miller, A.J.1    Joseph, P.M.2
  • 16
    • 33748519550 scopus 로고    scopus 로고
    • Slice profile measurements of half pulse excitation for MR-imaging with ultra-short echo times (UTE)
    • F. Staehle, S. Nielles-Vallespin, A. Bongers, and L.R. Schad Slice profile measurements of half pulse excitation for MR-imaging with ultra-short echo times (UTE) Z. Med. Phys. 16 2006 200 207
    • (2006) Z. Med. Phys. , vol.16 , pp. 200-207
    • Staehle, F.1    Nielles-Vallespin, S.2    Bongers, A.3    Schad, L.R.4
  • 17
    • 66149139300 scopus 로고    scopus 로고
    • Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging
    • J.M. Pauly, B.L. Daniel, and K.M. Pauly Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging Magn. Reson. Med. 61 2009 1083 1089
    • (2009) Magn. Reson. Med. , vol.61 , pp. 1083-1089
    • Pauly, J.M.1    Daniel, B.L.2    Pauly, K.M.3
  • 18
    • 66149084901 scopus 로고    scopus 로고
    • Improved half RF slice selectivity in the presence of eddy currents with out-of-slice saturation
    • S. Josan, E. Kaye, J.M. Pauly, B.L. Daniel, and K.B. Pauly Improved half RF slice selectivity in the presence of eddy currents with out-of-slice saturation Magn. Reson. Med. 61 2009 1090 1095
    • (2009) Magn. Reson. Med. , vol.61 , pp. 1090-1095
    • Josan, S.1    Kaye, E.2    Pauly, J.M.3    Daniel, B.L.4    Pauly, K.B.5
  • 19
    • 66149139300 scopus 로고    scopus 로고
    • Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging
    • S. Josan, J.M. Pauly, B.L. Daniel, and K.B. Pauly Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging Magn. Reson. Med. 61 2009 1083 1089
    • (2009) Magn. Reson. Med. , vol.61 , pp. 1083-1089
    • Josan, S.1    Pauly, J.M.2    Daniel, B.L.3    Pauly, K.B.4
  • 20
    • 46849108279 scopus 로고    scopus 로고
    • Improved slice selection for R2 mapping during cryoablation with eddy current compensation
    • A. Lu, B.L. Daniel, J.M. Pauly, and K.B. Pauly Improved slice selection for R2 mapping during cryoablation with eddy current compensation J. Magn. Reson. Imag. 28 2008 190 198
    • (2008) J. Magn. Reson. Imag. , vol.28 , pp. 190-198
    • Lu, A.1    Daniel, B.L.2    Pauly, J.M.3    Pauly, K.B.4
  • 22
    • 35948947385 scopus 로고    scopus 로고
    • Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging
    • P.E.Z. Larson, S.M. Conolly, J.M. Pauly, and D.G. Nishimura Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging Magn. Reson. Med. 58 2007 952 961
    • (2007) Magn. Reson. Med. , vol.58 , pp. 952-961
    • Larson, P.E.Z.1    Conolly, S.M.2    Pauly, J.M.3    Nishimura, D.G.4
  • 23
    • 34247581820 scopus 로고    scopus 로고
    • Selective 3D ultrashort TE imaging: Comparison of "dual-echo" acquisition and magnetization preparation for improving short-T2 contrast
    • J. Rahmer, U. Blume, and P. Börnert Selective 3D ultrashort TE imaging: comparison of "dual-echo" acquisition and magnetization preparation for improving short-T2 contrast Magma 20 2007 83 92
    • (2007) Magma , vol.20 , pp. 83-92
    • Rahmer, J.1    Blume, U.2    Börnert, P.3
  • 24
    • 0027411977 scopus 로고
    • The general solution to the Bloch equation with constant RF and relaxation terms: Application to saturation and slice selection
    • R.V. Mulkern, and M.L. Williams The general solution to the Bloch equation with constant RF and relaxation terms: application to saturation and slice selection Med. Phys. 20 1993 5 13
    • (1993) Med. Phys. , vol.20 , pp. 5-13
    • Mulkern, R.V.1    Williams, M.L.2
  • 25
    • 0028495764 scopus 로고
    • Material properties imaging of cross-linked polymers by NMR
    • W. Kuhn, P. Barth, S. Hafner, G. Simon, and H. Schneider Material properties imaging of cross-linked polymers by NMR Macromolecules 27 1994 5773 5779
    • (1994) Macromolecules , vol.27 , pp. 5773-5779
    • Kuhn, W.1    Barth, P.2    Hafner, S.3    Simon, G.4    Schneider, H.5
  • 26
    • 36149017694 scopus 로고
    • Exchange narrowing in paramagnetic resonance
    • P.W. Anderson, and P.R. Weiss Exchange narrowing in paramagnetic resonance Rev. Mod. Phys. 25 1953 269 276
    • (1953) Rev. Mod. Phys. , vol.25 , pp. 269-276
    • Anderson, P.W.1    Weiss, P.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.