-
1
-
-
77952593076
-
Recent advances in modeling and analysis of bioelectric and biomagnetic sources
-
T.H. Sander, T.R. Knösche, and A. Schlögl Recent advances in modeling and analysis of bioelectric and biomagnetic sources Biomed. Technol. 55 2010 65 76
-
(2010)
Biomed. Technol.
, vol.55
, pp. 65-76
-
-
Sander, T.H.1
Knösche, T.R.2
Schlögl, A.3
-
2
-
-
4344574647
-
Fundamentals of EEG measurement
-
M. Teplan Fundamentals of EEG measurement Meas. Sci. Technol. 2 2002 1 11
-
(2002)
Meas. Sci. Technol.
, vol.2
, pp. 1-11
-
-
Teplan, M.1
-
3
-
-
0034048104
-
A direct comparison of wet, dry and insulating bioelectric recording electrodes
-
A. Searle, and L. Kirkup A direct comparison of wet, dry and insulating bioelectric recording electrodes Physiol. Meas. 21 2000 271 283
-
(2000)
Physiol. Meas.
, vol.21
, pp. 271-283
-
-
Searle, A.1
Kirkup, L.2
-
4
-
-
84862777322
-
Biosensor technologies for augmented brain-computer interfaces in the next decades
-
L. Lun-De, L. Chin-Teng, and K. McDowell Biosensor technologies for augmented brain-computer interfaces in the next decades Electr. Power Res. Inst. 100 2012 1553 1566
-
(2012)
Electr. Power Res. Inst.
, vol.100
, pp. 1553-1566
-
-
Lun-De, L.1
Chin-Teng, L.2
McDowell, K.3
-
5
-
-
1242292266
-
Effects of electrode density and electrolyte spreading in dense array electroencephalographic recording
-
L.L. Greischar, C.A. Burghy, and C.M. van Reekum Effects of electrode density and electrolyte spreading in dense array electroencephalographic recording Clin. Neurophysiol. 115 2004 710 720
-
(2004)
Clin. Neurophysiol.
, vol.115
, pp. 710-720
-
-
Greischar, L.L.1
Burghy, C.A.2
Van Reekum, C.M.3
-
6
-
-
78149356000
-
The electrode-skin interface and optimal detection of bioelectric signals
-
R. Merletti The electrode-skin interface and optimal detection of bioelectric signals Physiol. Meas. 31 2010 154 156
-
(2010)
Physiol. Meas.
, vol.31
, pp. 154-156
-
-
Merletti, R.1
-
7
-
-
77249176156
-
Capacitive ECG system with direct access to standard leads and body surface potential mapping
-
M. Oehler, M. Schilling, and H.D. Esperer Capacitive ECG system with direct access to standard leads and body surface potential mapping Biomed. Technol. 54 2009 329 335
-
(2009)
Biomed. Technol.
, vol.54
, pp. 329-335
-
-
Oehler, M.1
Schilling, M.2
Esperer, H.D.3
-
8
-
-
84886504502
-
Mehrkanaliges EKG-Messsystem mit kapazitiver Patientenankopplung
-
B. Eilebrecht, A. Schommartz, and T. Wartzek Mehrkanaliges EKG-Messsystem mit kapazitiver Patientenankopplung Biomed. Technol. 55 2010 28 30
-
(2010)
Biomed. Technol.
, vol.55
, pp. 28-30
-
-
Eilebrecht, B.1
Schommartz, A.2
Wartzek, T.3
-
10
-
-
84878277066
-
A capacitive, biocompatible and adhesive electrode for long-term and cap-free monitoring of EEG signals
-
S.M. Lee, J.H. Kim, and H.J. Byeon A capacitive, biocompatible and adhesive electrode for long-term and cap-free monitoring of EEG signals J. Neural Eng. 10 2013
-
(2013)
J. Neural Eng.
, vol.10
-
-
Lee, S.M.1
Kim, J.H.2
Byeon, H.J.3
-
11
-
-
78649288597
-
Hydrogel-based photonic sensor for a biopotential wearable recording system
-
M.S. Fernandes, N.S. Dias, and A.F. Silva Hydrogel-based photonic sensor for a biopotential wearable recording system Biosens. Bioelectron. 26 2010 80 86
-
(2010)
Biosens. Bioelectron.
, vol.26
, pp. 80-86
-
-
Fernandes, M.S.1
Dias, N.S.2
Silva, A.F.3
-
15
-
-
30244483471
-
An active, microfabricated, scalp electrode array for EEG recording
-
B. Alizadeh-Taheri, R.L. Smith, and R.T. Knight An active, microfabricated, scalp electrode array for EEG recording Sens. Actuators A: Phys. 54 1996 606 611
-
(1996)
Sens. Actuators A: Phys.
, vol.54
, pp. 606-611
-
-
Alizadeh-Taheri, B.1
Smith, R.L.2
Knight, R.T.3
-
16
-
-
78249262601
-
New dry electrodes based on iridium oxide (IrO) for non-invasive biopotential recordings and stimulation
-
N.S. Dias, A. Carmo, and A. Ferreira da Silva New dry electrodes based on iridium oxide (IrO) for non-invasive biopotential recordings and stimulation Sens. Actuators A: Phys. 164 2010 28 34
-
(2010)
Sens. Actuators A: Phys.
, vol.164
, pp. 28-34
-
-
Dias, N.S.1
Carmo, A.2
Ferreira Da Silva, A.3
-
18
-
-
70349511936
-
The role of composition, morphology and crystalline structure in the electrochemical behaviour of TiNx thin films for dry electrode sensor materials
-
L.T. Cunha, P. Pedrosa, and C.J. Tavares The role of composition, morphology and crystalline structure in the electrochemical behaviour of TiNx thin films for dry electrode sensor materials Electrochim. Acta 55 2009 59 67
-
(2009)
Electrochim. Acta
, vol.55
, pp. 59-67
-
-
Cunha, L.T.1
Pedrosa, P.2
Tavares, C.J.3
-
19
-
-
81555220994
-
Novel TiNx-based biosignal electrodes for electroencephalography
-
P. Fiedler, L.T. Cunha, and P. Pedrosa Novel TiNx-based biosignal electrodes for electroencephalography Meas. Sci. Technol. 22 2011
-
(2011)
Meas. Sci. Technol.
, vol.22
-
-
Fiedler, P.1
Cunha, L.T.2
Pedrosa, P.3
-
20
-
-
84893941298
-
Electrochemical behavior of nanocomposite Agx:TiN thin films for dry biopotential electrodes
-
P. Pedrosa, E. Alves, and N.P. Barradas Electrochemical behavior of nanocomposite Agx:TiN thin films for dry biopotential electrodes Electrochim. Acta 125 2014 48 57
-
(2014)
Electrochim. Acta
, vol.125
, pp. 48-57
-
-
Pedrosa, P.1
Alves, E.2
Barradas, N.P.3
-
21
-
-
54049150767
-
An EEG (electroencephalogram) recording system with carbon wire electrodes for simultaneous EEG-fMRI (functional magnetic resonance imaging) recording
-
M. Negishi, M. Abildgaard, and I. Laufer An EEG (electroencephalogram) recording system with carbon wire electrodes for simultaneous EEG-fMRI (functional magnetic resonance imaging) recording J. Neurosci. Methods 173 2008 99 107
-
(2008)
J. Neurosci. Methods
, vol.173
, pp. 99-107
-
-
Negishi, M.1
Abildgaard, M.2
Laufer, I.3
-
22
-
-
77949916619
-
A new EEG recording system for passive dry electrodes
-
G. Gargiulo, R.A. Calvo, and P. Bifulco A new EEG recording system for passive dry electrodes Clin. Neurophysiol. 121 2010 686 693
-
(2010)
Clin. Neurophysiol.
, vol.121
, pp. 686-693
-
-
Gargiulo, G.1
Calvo, R.A.2
Bifulco, P.3
-
24
-
-
84855892966
-
TiNx coated polycarbonate for bio-electrode applications
-
P. Pedrosa, E. Alves, and N.P. Barradas TiNx coated polycarbonate for bio-electrode applications Corros. Sci. 56 2012 49 57
-
(2012)
Corros. Sci.
, vol.56
, pp. 49-57
-
-
Pedrosa, P.1
Alves, E.2
Barradas, N.P.3
-
25
-
-
1242284425
-
Bioactivity of TiN-coated titanium implants
-
S. Piscanec, L.C. Ciacchi, and E. Vesselli Bioactivity of TiN-coated titanium implants Acta Mater. 52 2004 1237 1245
-
(2004)
Acta Mater.
, vol.52
, pp. 1237-1245
-
-
Piscanec, S.1
Ciacchi, L.C.2
Vesselli, E.3
-
26
-
-
19944370775
-
Influence of nitrogen content on the structural, mechanical and electrical properties of TiN thin films
-
F. Vaz, J. Ferreira, and E. Ribeiro Influence of nitrogen content on the structural, mechanical and electrical properties of TiN thin films Surf. Coat. Technol. 191 2005 317 323
-
(2005)
Surf. Coat. Technol.
, vol.191
, pp. 317-323
-
-
Vaz, F.1
Ferreira, J.2
Ribeiro, E.3
-
27
-
-
0032607559
-
The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology
-
G.H. Klem, H.O. Luders, and H.H. Jasper The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology Electroencephalogr. Clin. Neurophysiol. Suppl. 52 1999 3 6
-
(1999)
Electroencephalogr. Clin. Neurophysiol. Suppl.
, vol.52
, pp. 3-6
-
-
Klem, G.H.1
Luders, H.O.2
Jasper, H.H.3
-
28
-
-
77249140451
-
ISCEV standard for clinical visual evoked potentials (2009 update)
-
J.V. Odom, M. Bach, and M. Brigell ISCEV standard for clinical visual evoked potentials (2009 update) Doc. Ophthalmol. 120 2010 111 119
-
(2010)
Doc. Ophthalmol.
, vol.120
, pp. 111-119
-
-
Odom, J.V.1
Bach, M.2
Brigell, M.3
-
29
-
-
0021700959
-
Spatial analysis of evoked potentials in man - A review
-
D. Lehmann, and W. Skrandies Spatial analysis of evoked potentials in man - a review Prog. Neurobiol. 23 1984 227 250
-
(1984)
Prog. Neurobiol.
, vol.23
, pp. 227-250
-
-
Lehmann, D.1
Skrandies, W.2
-
32
-
-
84883203613
-
Poly(3,4-ethylenedioxythiophene) (PEDOT) as interface material for improving electrochemical performance of microneedles array-based dry electrode
-
Y. Chen, W. Pei, and S. Chen Poly(3,4-ethylenedioxythiophene) (PEDOT) as interface material for improving electrochemical performance of microneedles array-based dry electrode Sens. Actuators B: Chem. 188 2013 747 756
-
(2013)
Sens. Actuators B: Chem.
, vol.188
, pp. 747-756
-
-
Chen, Y.1
Pei, W.2
Chen, S.3
-
35
-
-
79954498413
-
Bristle-sensors - Low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications
-
C. Grozea, C.D. Voinescu, and S. Fazil Bristle-sensors - low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications J. Neural. Eng. 8 2011
-
(2011)
J. Neural. Eng.
, vol.8
-
-
Grozea, C.1
Voinescu, C.D.2
Fazil, S.3
|