메뉴 건너뛰기




Volumn 22, Issue 12, 2011, Pages

Novel TiNx-based biosignal electrodes for electroencephalography

Author keywords

bioelectric; biomedical electrodes; dc magnetron sputtering; electroencephalography; signals; titanium nitride thin films

Indexed keywords

ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; ELECTROENCEPHALOGRAPHY; ELECTROLYTES; ELECTROPHYSIOLOGY; NITRIDES; REACTIVE SPUTTERING; SIGNAL PROCESSING; SIGNALING; SILVER; THIN FILMS; TITANIUM; TITANIUM COMPOUNDS;

EID: 81555220994     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/22/12/124007     Document Type: Article
Times cited : (17)

References (20)
  • 1
    • 4344574647 scopus 로고    scopus 로고
    • Fundamentals of EEG measurement
    • 1-11
    • Teplan M 2002 Fundamentals of EEG measurement Meas. Sci. Rev. 2 (2) 1-11
    • (2002) Meas. Sci. Rev. , vol.2 , pp. 2
    • Teplan, M.1
  • 4
    • 78249262601 scopus 로고    scopus 로고
    • New dry electrodes based on iridium oxide (IrO) for non-invasive biopotential recordings and stimulation
    • Dias N S, Carmo A, Ferreira da Silva A, Mendes P M and Correia J H 2010 New dry electrodes based on iridium oxide (IrO) for non-invasive biopotential recordings and stimulation Sensors Actuators A 164 28-34
    • (2010) Sensors Actuators , vol.164 , Issue.1-2 , pp. 28-34
    • Dias, N.S.1    Carmo, A.2    Ferreira Da Silva, A.3    Mendes, P.M.4    Correia, J.H.5
  • 6
    • 79956006562 scopus 로고    scopus 로고
    • Remote detection of human electroencephalograms using ultrahigh input impedance electric potential sensors
    • Harland C J, Clark T D and Prance R J 2002 Remote detection of human electroencephalograms using ultrahigh input impedance electric potential sensors Appl. Phys. Lett. 81 3284-6
    • (2002) Appl. Phys. Lett. , vol.81 , Issue.17 , pp. 3284-3286
    • Harland, C.J.1    Clark, T.D.2    Prance, R.J.3
  • 10
    • 0034048104 scopus 로고    scopus 로고
    • A direct comparison of wet, dry and insulating bioelectric recording electrodes
    • DOI 10.1088/0967-3334/21/2/307, PII S0967333400090511
    • Searle A and Kirkup L 2000 A direct comparison of wet, dry and insulating bioelectric recording electrodes Physiol. Meas. 21 271-83 (Pubitemid 30353435)
    • (2000) Physiological Measurement , vol.21 , Issue.2 , pp. 271-283
    • Searle, A.1    Kirkup, L.2
  • 11
    • 78149356000 scopus 로고    scopus 로고
    • The electrode-skin interface and optimal detection of bioelectric signals
    • Merletti R 2010 The electrode-skin interface and optimal detection of bioelectric signals Physiol. Meas. 31
    • (2010) Physiol. Meas. , vol.31
    • Merletti, R.1
  • 15
    • 0032607559 scopus 로고    scopus 로고
    • The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology
    • Klem G H, Lüders H O, Jasper H H and Elger C 1999 The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology Electroencephalogr. Clin. Neurophysiol. Suppl. 52 3-6
    • (1999) Electroencephalogr. Clin. Neurophysiol. Suppl. , vol.52 , pp. 3-6
    • Klem, G.H.1    Lüders, H.O.2    Jasper, H.H.3    Elger, C.4
  • 16
    • 0036045570 scopus 로고    scopus 로고
    • Investigation into the origin of the noise of surface electrodes
    • Huigen E, Peper A and Grimbergen C A 2002 Investigation into the origin of the noise of surface electrodes Med. Biol. Eng. Comput. 40 332-8
    • (2002) Med. Biol. Eng. Comput. , vol.40 , Issue.3 , pp. 332-338
    • Huigen, E.1    Peper, A.2    Grimbergen, C.A.3
  • 17
    • 32544438928 scopus 로고    scopus 로고
    • The influence of amplifier, interface and biological noise on signal quality in high-resolution EEG recordings
    • DOI 10.1088/0967-3334/27/2/002, PII S0967333406050039
    • Scheer H J, Sander T and Trahms L 2006 The influence of amplifier, interface and biological noise on the signal quality in high-resolution EEG recordings Physiol. Meas. 27 109-17 (Pubitemid 43232102)
    • (2006) Physiological Measurement , vol.27 , Issue.2 , pp. 109-117
    • Scheer, H.J.1    Sander, T.2    Trahms, L.3
  • 18
    • 47649115797 scopus 로고    scopus 로고
    • Electrochemical and geometrical characterization of iridium oxide electrodes in stainless steel substrate
    • Mayorga Martinez C C, Madrid R E and Felice C J 2008 Electrochemical and geometrical characterization of iridium oxide electrodes in stainless steel substrate Sensors Actuators B 133 682-6
    • (2008) Sensors Actuators , vol.133 , Issue.2 , pp. 682-686
    • Mayorga Martinez, C.C.1    Madrid, R.E.2    Felice, C.J.3
  • 19
    • 34447580194 scopus 로고    scopus 로고
    • Identifying mutual information transfer in the brain with differential-algebraic modeling: Evidence for fast oscillatory coupling between cortical somatosensory areas 3b and 1
    • Haueisen J, Leistritz L, Susse T, Curio G and Witte H 2007 Identifying mutual information transfer in the brain with differential-algebraic modeling: evidence for fast oscillatory coupling between cortical somatosensory areas 3b and 1 Neuroimage 37 130-5
    • (2007) Neuroimage , vol.37 , Issue.1 , pp. 130-135
    • Haueisen, J.1    Leistritz, L.2    Susse, T.3    Curio, G.4    Witte, H.5
  • 20
    • 74049140826 scopus 로고    scopus 로고
    • Analysis of induced components in electroencephalograms using a multiple correlation method
    • Graichen U, Witte H and Haueisen J 2009 Analysis of induced components in electroencephalograms using a multiple correlation method Biomed. Eng. Online 8
    • (2009) Biomed. Eng. Online , vol.8
    • Graichen, U.1    Witte, H.2    Haueisen, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.