메뉴 건너뛰기




Volumn 40, Issue 5, 2014, Pages 1091-1098

Reproducibility of MRI renal artery blood flow and BOLD measurements in patients with chronic kidney disease and healthy controls

Author keywords

Renal artery blood flow Blood oxygenation level dependent MRI Reproducibility Kidney

Indexed keywords

OXYGEN;

EID: 84913610171     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24446     Document Type: Article
Times cited : (42)

References (32)
  • 1
    • 80155201288 scopus 로고    scopus 로고
    • Renal oxidative stress, oxygenation, and hypertension
    • Palm F, Nordquist L. Renal oxidative stress, oxygenation, and hypertension. Am J Physiol Regul Integr Comp Physiol 2011;301: R1229-R1241.
    • (2011) Am J Physiol Regul Integr Comp Physiol , vol.301 , pp. R1229-R1241
    • Palm, F.1    Nordquist, L.2
  • 2
    • 42149140586 scopus 로고    scopus 로고
    • Hypertensive nephrosclerosis
    • Hill G. Hypertensive nephrosclerosis. Curr Opin Nephrol Hypertens 2008;17:266-270.
    • (2008) Curr Opin Nephrol Hypertens , vol.17 , pp. 266-270
    • Hill, G.1
  • 3
    • 4644255532 scopus 로고    scopus 로고
    • Hypoxia and tubulointerstitial injury: A final common pathway to end-stage renal failure
    • Nangaku M. Hypoxia and tubulointerstitial injury: a final common pathway to end-stage renal failure. Nephron Exp Nephrol 2004;98:e8-e12.
    • (2004) Nephron Exp Nephrol , vol.98 , pp. e8-e12
    • Nangaku, M.1
  • 4
    • 77954048345 scopus 로고    scopus 로고
    • Vascular endothelial growth factor-A, matrix metalloproteinase-1, and macrophage migration inhibition factor changes in the porcine remnant kidney model: Evaluation by magnetic resonance imaging
    • Misra S, Misra KD, Glockner JF. Vascular endothelial growth factor-A, matrix metalloproteinase-1, and macrophage migration inhibition factor changes in the porcine remnant kidney model: evaluation by magnetic resonance imaging. J Vasc Interv Radiol 2010;21:1071-1077.
    • (2010) J Vasc Interv Radiol , vol.21 , pp. 1071-1077
    • Misra, S.1    Misra, K.D.2    Glockner, J.F.3
  • 5
    • 0029685408 scopus 로고    scopus 로고
    • MR velocity mapping measurement of renal artery blood flow in patients with impaired kidney function
    • Cortsen M, Petersen LJ, Stahlberg F, et al. MR velocity mapping measurement of renal artery blood flow in patients with impaired kidney function. Acta Radiol 1996;37:79-84.
    • (1996) Acta Radiol , vol.37 , pp. 79-84
    • Cortsen, M.1    Petersen, L.J.2    Stahlberg, F.3
  • 6
    • 0344333437 scopus 로고    scopus 로고
    • Successful transplantation of adult-sized kidneys into infants requires maintenance of high aortic blood flow
    • Salvatierra O Jr, Singh T, Shifrin R, et al. Successful transplantation of adult-sized kidneys into infants requires maintenance of high aortic blood flow. Transplantation 1998;66:819-823.
    • (1998) Transplantation , vol.66 , pp. 819-823
    • Salvatierra, O.1    Singh, T.2    Shifrin, R.3
  • 7
    • 0031782185 scopus 로고    scopus 로고
    • Renal blood flow: Measurement in vivo with rapid spiral MR imaging
    • Sommer G, Corrigan G, Fredrickson J, et al. Renal blood flow: measurement in vivo with rapid spiral MR imaging. Radiology 1998;208:729-734.
    • (1998) Radiology , vol.208 , pp. 729-734
    • Sommer, G.1    Corrigan, G.2    Fredrickson, J.3
  • 8
    • 84857120722 scopus 로고    scopus 로고
    • A preliminary study of blood-oxygen-level-dependent MRI in patients with chronic kidney disease
    • Xin-Long P, Jing-Xia X, Jian-Yu L, Song W, Xin-Kui T. A preliminary study of blood-oxygen-level-dependent MRI in patients with chronic kidney disease. Magn Reson Imaging 2012;30:330-335.
    • (2012) Magn Reson Imaging , vol.30 , pp. 330-335
    • Xin-Long, P.1    Jing-Xia, X.2    Jian-Yu, L.3    Song, W.4    Xin-Kui, T.5
  • 10
    • 0035035078 scopus 로고    scopus 로고
    • Changes in intrarenal oxygenation as evaluated by bold MRI in a rat kidneymodel for radiocontrast nephropathy
    • Prasad PV, Priatna A, Spokes K, Epstein FH. Changes in intrarenal oxygenation as evaluated by BOLD MRI in a rat kidneymodel for radiocontrast nephropathy. JMagn Reson Imaging 2001;13:744-747.
    • (2001) JMagn Reson Imaging , vol.13 , pp. 744-747
    • Prasad, P.V.1    Priatna, A.2    Spokes, K.3    Epstein, F.H.4
  • 11
    • 79953887287 scopus 로고    scopus 로고
    • Evolution of renal oxygen content measured by bold MRI downstream a chronic renal artery stenosis
    • Rognant N, Guebre-Egziabher F, Bacchetta J, et al. Evolution of renal oxygen content measured by BOLD MRI downstream a chronic renal artery stenosis. Nephrol Dial Transplant 2011;26:1205-1210.
    • (2011) Nephrol Dial Transplant , vol.26 , pp. 1205-1210
    • Rognant, N.1    Guebre-Egziabher, F.2    Bacchetta, J.3
  • 12
    • 79952253559 scopus 로고    scopus 로고
    • Blood oxygen leveldependent (bold) MRI of diabetic nephropathy: Preliminary experience
    • Wang ZJ, Kumar R, Banerjee S, Hsu CY. Blood oxygen leveldependent (BOLD) MRI of diabetic nephropathy: preliminary experience. J Magn Reson Imaging 2011;33:655-660.
    • (2011) J Magn Reson Imaging , vol.33 , pp. 655-660
    • Wang, Z.J.1    Kumar, R.2    Banerjee, S.3    Hsu, C.Y.4
  • 13
    • 79960957297 scopus 로고    scopus 로고
    • Noninvasive evaluation of kidney hypoxia and fibrosis using magnetic resonance imaging
    • Inoue T, Kozawa E, Okada H, et al. Noninvasive evaluation of kidney hypoxia and fibrosis using magnetic resonance imaging. J Am Soc Nephrol 2011;22:1429-1434.
    • (2011) J Am Soc Nephrol , vol.22 , pp. 1429-1434
    • Inoue, T.1    Kozawa, E.2    Okada, H.3
  • 14
    • 80055069176 scopus 로고    scopus 로고
    • Increased glomerular filtration rate in early metabolic syndrome is associated with renal adiposity and microvascular proliferation
    • Li Z, Woollard JR, Wang S, et al. Increased glomerular filtration rate in early metabolic syndrome is associated with renal adiposity and microvascular proliferation. Am J Physiol Renal Physiol 2011;30:F1078-F1087.
    • (2011) Am J Physiol Renal Physiol , vol.30 , pp. F1078-F1087
    • Li, Z.1    Woollard, J.R.2    Wang, S.3
  • 15
    • 84859856686 scopus 로고    scopus 로고
    • Angiotensin II receptor blocker partially ameliorated intrarenal hypoxia in chronic kidney disease patients: A pre-/post-study
    • Manotham K, Ongvilawan B, Urusopone P, et al. Angiotensin II receptor blocker partially ameliorated intrarenal hypoxia in chronic kidney disease patients: a pre-/post-study. Intern Med J 2012;42:e33-e37.
    • (2012) Intern Med J , vol.42 , pp. e33-e37
    • Manotham, K.1    Ongvilawan, B.2    Urusopone, P.3
  • 16
    • 23044461489 scopus 로고    scopus 로고
    • Validation of quantitative bold MRI measurements in kidney: Application to unilateral ureteral obstruction
    • Pedersen M, Dissing T, Morkenborg J, et al. Validation of quantitative BOLD MRI measurements in kidney: application to unilateral ureteral obstruction. Kidney Int 2005;67:2305-2312.
    • (2005) Kidney Int , vol.67 , pp. 2305-2312
    • Pedersen, M.1    Dissing, T.2    Morkenborg, J.3
  • 17
    • 20544465208 scopus 로고    scopus 로고
    • Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: Normal values and reproducibility
    • Bax L, Bakker CJ, Klein WM, Blanken N, Beutler JJ, Mali WP. Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: normal values and reproducibility. J Vasc Interv Radiol 2005;16:807-814.
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 807-814
    • Bax, L.1    Bakker, C.J.2    Klein, W.M.3    Blanken, N.4    Beutler, J.J.5    Mali, W.P.6
  • 18
    • 77950606467 scopus 로고    scopus 로고
    • Renal arterial blood flow measurement by breath-held MRI: Accuracy in phantom scans and reproducibility in healthy subjects
    • Dambreville S, Chapman AB, Torres VE, et al. Renal arterial blood flow measurement by breath-held MRI: accuracy in phantom scans and reproducibility in healthy subjects. Magn Reson Med 2010;63:940-950.
    • (2010) Magn Reson Med , vol.63 , pp. 940-950
    • Dambreville, S.1    Chapman, A.B.2    Torres, V.E.3
  • 19
    • 17844368393 scopus 로고    scopus 로고
    • Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI
    • Park JB, Santos JM, Hargreaves BA, et al. Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI. J Magn Reson Imaging 2005;21:590-595.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 590-595
    • Park, J.B.1    Santos, J.M.2    Hargreaves, B.A.3
  • 20
    • 32844475579 scopus 로고    scopus 로고
    • Non-invasive monitoring of renal oxygenation using bold-MRI: A reproducibility study
    • Simon-Zoula SC, Hofmann L, Giger A, et al. Non-invasive monitoring of renal oxygenation using BOLD-MRI: a reproducibility study. NMR Biomed 2006;19:84-89.
    • (2006) NMR Biomed , vol.19 , pp. 84-89
    • Simon-Zoula, S.C.1    Hofmann, L.2    Giger, A.3
  • 21
    • 33846708818 scopus 로고    scopus 로고
    • Functional evaluation of transplanted kidneys with diffusion-weighted and bold mr imaging: Initial experience
    • Thoeny HC, Zumstein D, Simon-Zoula S, et al. Functional evaluation of transplanted kidneys with diffusion-weighted and BOLD MR imaging: initial experience. Radiology 2006;241:812-821.
    • (2006) Radiology , vol.241 , pp. 812-821
    • Thoeny, H.C.1    Zumstein, D.2    Simon-Zoula, S.3
  • 22
    • 84860322769 scopus 로고    scopus 로고
    • Evaluation of transplanted kidneys using blood oxygenation level-dependent MRI at 3 t: A preliminary study
    • Park SY, Kim CK, Park BK, Huh W, Kim SJ, Kim B. Evaluation of transplanted kidneys using blood oxygenation level-dependent MRI at 3 T: a preliminary study. AJR Am J Roentgenol 2012;198: 1108-1114.
    • (2012) AJR Am J Roentgenol , vol.198 , pp. 1108-1114
    • Park, S.Y.1    Kim, C.K.2    Park, B.K.3    Huh, W.4    Kim, S.J.5    Kim, B.6
  • 23
    • 0030405112 scopus 로고    scopus 로고
    • Aging and the kidney
    • Epstein M. Aging and the kidney. J Am Soc Nephrol 1996;7: 1106-1122.
    • (1996) J Am Soc Nephrol , vol.7 , pp. 1106-1122
    • Epstein, M.1
  • 24
    • 47149092668 scopus 로고    scopus 로고
    • Renal parenchymal hypoxia, hypoxia response and the progression of chronic kidney disease
    • Heyman SN, Khamaisi M, Rosen S, Rosenberger C. Renal parenchymal hypoxia, hypoxia response and the progression of chronic kidney disease. Am J Nephrol 2008;28:998-1006.
    • (2008) Am J Nephrol , vol.28 , pp. 998-1006
    • Heyman, S.N.1    Khamaisi, M.2    Rosen, S.3    Rosenberger, C.4
  • 25
    • 2442580816 scopus 로고    scopus 로고
    • Evaluation of the reproducibility of intrarenal R2∗ and deltaR2∗ measurements following administration of furosemide and during waterload
    • Li LP, Storey P, Pierchala L, Li W, Polzin J, Prasad P. Evaluation of the reproducibility of intrarenal R2∗ and DeltaR2∗ measurements following administration of furosemide and during waterload. J Magn Reson Imaging 2004;19:610-616.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 610-616
    • Li, L.P.1    Storey, P.2    Pierchala, L.3    Li, W.4    Polzin, J.5    Prasad, P.6
  • 26
    • 84858325827 scopus 로고    scopus 로고
    • Renal bold-MRI and assessment for renal hypoxia
    • Neugarten J. Renal BOLD-MRI and assessment for renal hypoxia. Kidney Int 2012;81:613-614.
    • (2012) Kidney Int , vol.81 , pp. 613-614
    • Neugarten, J.1
  • 27
    • 79960957297 scopus 로고    scopus 로고
    • Noninvasive evaluation of kidney hypoxia and fibrosis using magnetic resonance
    • Inoue T, Kozawa E, Okada H, et al. Noninvasive evaluation of kidney hypoxia and fibrosis using magnetic resonance. J Am Soc Nephrol 2011;22:1429-1434.
    • (2011) J Am Soc Nephrol , vol.22 , pp. 1429-1434
    • Inoue, T.1    Kozawa, E.2    Okada, H.3
  • 28
    • 34548084570 scopus 로고    scopus 로고
    • Normotensive ischemic acute renal failure
    • Abuelo JG. Normotensive ischemic acute renal failure. N Engl J Med 2007;357:797-805.
    • (2007) N Engl J Med , vol.357 , pp. 797-805
    • Abuelo, J.G.1
  • 29
    • 44349159590 scopus 로고    scopus 로고
    • The use of magnetic resonance to evaluate tissue oxygenation in renal artery
    • Textor SC, Glockner JF, Lerman LO, et al. The use of magnetic resonance to evaluate tissue oxygenation in renal artery. J Am Soc Nephrol 2008;19:780-788.
    • (2008) J Am Soc Nephrol , vol.19 , pp. 780-788
    • Textor, S.C.1    Glockner, J.F.2    Lerman, L.O.3
  • 30
    • 84866274624 scopus 로고    scopus 로고
    • Quantitative bold response of the renal medulla to hyperoxic challenge at 1.5T and 3.0T
    • Donati OF, Nanz D, Serra AL, Boss A. Quantitative BOLD response of the renal medulla to hyperoxic challenge at 1.5T and 3.0T. NMR Biomed 2012;25:1133-1138.
    • (2012) NMR Biomed , vol.25 , pp. 1133-1138
    • Donati, O.F.1    Nanz, D.2    Serra, A.L.3    Boss, A.4
  • 31
    • 70049084540 scopus 로고    scopus 로고
    • Influence of oxygen and carbogen breathing on renal oxygenation measured by t2∗- weighted imaging at 3.0 T
    • Boss A, Martirosian P, Jehs MC, et al. Influence of oxygen and carbogen breathing on renal oxygenation measured by T2∗- weighted imaging at 3.0 T. NMR Biomed 2009;22:638-645.
    • (2009) NMR Biomed , vol.22 , pp. 638-645
    • Boss, A.1    Martirosian, P.2    Jehs, M.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.