메뉴 건너뛰기




Volumn 21, Issue 5, 2005, Pages 590-595

Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI

Author keywords

Fast imaging; Flow; Phase contrast; Renal; Spiral; Vascular

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BLOOD FLOW VELOCITY; BODY SURFACE; CASE REPORT; CONTROLLED STUDY; FEMALE; HEART CYCLE; HUMAN; HUMAN EXPERIMENT; IN VIVO STUDY; KIDNEY ALLOGRAFT REJECTION; KIDNEY BLOOD FLOW; KIDNEY FAILURE; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RENAL ARTERY; RENAL ARTERY BLOOD FLOW; REPRODUCIBILITY; TIME; UNGATED SPIRAL PHASE CONTRAST NUCLEAR MAGNETIC RESONANCE IMAGING;

EID: 17844368393     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20325     Document Type: Article
Times cited : (18)

References (20)
  • 1
    • 0023757559 scopus 로고
    • Ischemic renal disease: An overlooked clinical entity?
    • Jacobson HR. Ischemic renal disease: an overlooked clinical entity? Kidney Int 1988;34:729-743.
    • (1988) Kidney Int , vol.34 , pp. 729-743
    • Jacobson, H.R.1
  • 2
    • 0028144633 scopus 로고
    • Renal artery blood flow: Quantitation with phase-contrast MR imaging with and without breath holding
    • Debatin JF, Ting RH, Wegmuller H, et al. Renal artery blood flow: quantitation with phase-contrast MR imaging with and without breath holding. Radiology 1994;190:371-378.
    • (1994) Radiology , vol.190 , pp. 371-378
    • Debatin, J.F.1    Ting, R.H.2    Wegmuller, H.3
  • 4
    • 0023941993 scopus 로고
    • Role of cardiac atria in the human renal response to changing plasma volume
    • Myers BD, Peterson C, Molina C, et al. Role of cardiac atria in the human renal response to changing plasma volume. Am J Physiol 1988;254:F562-F573.
    • (1988) Am J Physiol , vol.254
    • Myers, B.D.1    Peterson, C.2    Molina, C.3
  • 5
    • 0036840892 scopus 로고    scopus 로고
    • Dynamic renal blood flow measurement by positron emission tomography in patients with CRF
    • Juillard L, Janier MF, Fouque D, et al. Dynamic renal blood flow measurement by positron emission tomography in patients with CRF. Am J Kidney Dis 2002;40:947-954.
    • (2002) Am J Kidney Dis , vol.40 , pp. 947-954
    • Juillard, L.1    Janier, M.F.2    Fouque, D.3
  • 7
    • 0031782185 scopus 로고    scopus 로고
    • Renal blood flow: Measurement in vivo with rapid spiral MR imaging
    • Sommer G, Corrigan G, Fredrickson J, et al. Renal blood flow: measurement in vivo with rapid spiral MR imaging. Radiology 1998; 208:729-734.
    • (1998) Radiology , vol.208 , pp. 729-734
    • Sommer, G.1    Corrigan, G.2    Fredrickson, J.3
  • 8
    • 12244310182 scopus 로고    scopus 로고
    • Rapid measurement of time-averaged blood flow using ungated spiral phase-contrast
    • Park JB, Olcott EW, Nishimura DG. Rapid measurement of time-averaged blood flow using ungated spiral phase-contrast. Magn Reson Med 2003;49:322-328.
    • (2003) Magn Reson Med , vol.49 , pp. 322-328
    • Park, J.B.1    Olcott, E.W.2    Nishimura, D.G.3
  • 9
    • 0029088782 scopus 로고
    • Magnetic resonance fluoroscopy using spirals with variable sampling densities
    • Spielman DM, Pauly JM, Meyer CH. Magnetic resonance fluoroscopy using spirals with variable sampling densities. Magn Reson Med 1995;34:388-394.
    • (1995) Magn Reson Med , vol.34 , pp. 388-394
    • Spielman, D.M.1    Pauly, J.M.2    Meyer, C.H.3
  • 10
    • 0030884045 scopus 로고    scopus 로고
    • Real-time interactive MRI on a conventional scanner
    • Kerr AB, Pauly JM, Hu BS, et al. Real-time interactive MRI on a conventional scanner. Magn Reson Med 1997;38:355-367.
    • (1997) Magn Reson Med , vol.38 , pp. 355-367
    • Kerr, A.B.1    Pauly, J.M.2    Hu, B.S.3
  • 13
    • 0023662620 scopus 로고
    • Simplified calculation of body-surface area
    • Mosteller RD. Simplified calculation of body-surface area. N Engl J Med 1987;317:1098.
    • (1987) N Engl J Med , vol.317 , pp. 1098
    • Mosteller, R.D.1
  • 15
    • 0027564412 scopus 로고
    • Accuracy of phase-contrast flow measurements in the presence of partial-volume effects
    • Tang C, Blatter DD, Parker DL. Accuracy of phase-contrast flow measurements in the presence of partial-volume effects. J Magn Reson Imaging 1993;3:377-385.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 377-385
    • Tang, C.1    Blatter, D.D.2    Parker, D.L.3
  • 16
    • 0027468047 scopus 로고
    • k-space description for MR imaging of dynamic objects
    • Xiang QS, Henkelman RM. k-Space description for MR imaging of dynamic objects. Magn Reson Med 1993;29:422-428.
    • (1993) Magn Reson Med , vol.29 , pp. 422-428
    • Xiang, Q.S.1    Henkelman, R.M.2
  • 17
    • 0031195397 scopus 로고    scopus 로고
    • Multishot rosette trajectories for spectrally selective MR imaging
    • Noll DC. Multishot rosette trajectories for spectrally selective MR imaging. IEEE Trans Med Imaging 1997;16:372-377.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 372-377
    • Noll, D.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.