-
1
-
-
84883791654
-
In situ, real-time visualization of electrochemistry using magnetic resonance imaging
-
M.M. Britton, P.M. Bayley, P.C. Howlett, A.J. Davenport, and M. Forsyth In situ, real-time visualization of electrochemistry using magnetic resonance imaging J. Phys. Chem. Lett. 4 2013 3019 3023
-
(2013)
J. Phys. Chem. Lett.
, vol.4
, pp. 3019-3023
-
-
Britton, M.M.1
Bayley, P.M.2
Howlett, P.C.3
Davenport, A.J.4
Forsyth, M.5
-
2
-
-
47549103480
-
Magnetic resonance imaging of water content across the Nafion membrane in an operational PEM fuel cell
-
Z. Zhang, J. Martin, J. Wu, H. Wang, K. Promislow, and B.J. Balcom Magnetic resonance imaging of water content across the Nafion membrane in an operational PEM fuel cell J. Magn. Reson. 193 2008 259 266
-
(2008)
J. Magn. Reson.
, vol.193
, pp. 259-266
-
-
Zhang, Z.1
Martin, J.2
Wu, J.3
Wang, H.4
Promislow, K.5
Balcom, B.J.6
-
3
-
-
77958036913
-
In situ NMR observation of the formation of metallic lithium microstructures in lithium batteries
-
R. Bhattacharyya, B. Key, H. Chen, A.S. Best, A.F. Hollenkamp, and C.P. Grey In situ NMR observation of the formation of metallic lithium microstructures in lithium batteries Nat. Mater. 9 2010 504 510
-
(2010)
Nat. Mater.
, vol.9
, pp. 504-510
-
-
Bhattacharyya, R.1
Key, B.2
Chen, H.3
Best, A.S.4
Hollenkamp, A.F.5
Grey, C.P.6
-
4
-
-
60349093862
-
Flow imaging of fluids in porous media by magnetization prepared centric-scan SPRITE
-
L. Li, Q. Chen, A.E. Marble, L. Romero-Zeron, B. Newling, and B.J. Balcom Flow imaging of fluids in porous media by magnetization prepared centric-scan SPRITE J. Magn. Reson. 197 2009 1 8
-
(2009)
J. Magn. Reson.
, vol.197
, pp. 1-8
-
-
Li, L.1
Chen, Q.2
Marble, A.E.3
Romero-Zeron, L.4
Newling, B.5
Balcom, B.J.6
-
5
-
-
21244441124
-
Measurement of rock core capillary pressure curves using a single-speed centrifuge and one dimensional magnetic resonance imaging
-
Q. Chen, and B.J. Balcom Measurement of rock core capillary pressure curves using a single-speed centrifuge and one dimensional magnetic resonance imaging J. Chem. Phys. 122 2005 214720
-
(2005)
J. Chem. Phys.
, vol.122
, pp. 214720
-
-
Chen, Q.1
Balcom, B.J.2
-
7
-
-
0003231823
-
Selective magnetic resonance imaging of chemicals in sandstone cores during flow
-
J.L.A. Williams, G. Maddinelli, and D.G. Taylor Selective magnetic resonance imaging of chemicals in sandstone cores during flow J. Magn. Reson. 109 1994 124 128
-
(1994)
J. Magn. Reson.
, vol.109
, pp. 124-128
-
-
Williams, J.L.A.1
Maddinelli, G.2
Taylor, D.G.3
-
8
-
-
84887819538
-
Design of a magnetic resonance imaging compatible metallic pressure vessel
-
M. Ouellette, H. Han, B. MacMillan, F. Goora, R. MacGregor, M. Hassan, and B.J. Balcom Design of a magnetic resonance imaging compatible metallic pressure vessel J. Pressure Ves. Technol. 135 2013 045001 45007
-
(2013)
J. Pressure Ves. Technol.
, vol.135
, pp. 045001-45007
-
-
Ouellette, M.1
Han, H.2
Macmillan, B.3
Goora, F.4
Macgregor, R.5
Hassan, M.6
Balcom, B.J.7
-
9
-
-
84904564830
-
Visualizing skin effects in conductors with MRI: Li MRI experiments and calculations
-
A.J. Ilott, S. Chandrashekar, A. Klöckner, H. Jung Chang, N.M. Trease, C.P. Grey, L. Greengard, and A. Jerschow Visualizing skin effects in conductors with MRI: Li MRI experiments and calculations J. Magn. Reson. 245 2014 143 149
-
(2014)
J. Magn. Reson.
, vol.245
, pp. 143-149
-
-
Ilott, A.J.1
Chandrashekar, S.2
Klöckner, A.3
Jung Chang, H.4
Trease, N.M.5
Grey, C.P.6
Greengard, L.7
Jerschow, A.8
-
13
-
-
0000546825
-
Artifacts in magnetic resonance imaging from metals
-
L.H. Bennett, P.S. Wang, and M.J. Donahue Artifacts in magnetic resonance imaging from metals J. Appl. Phys. 79 1996 4712 4714
-
(1996)
J. Appl. Phys.
, vol.79
, pp. 4712-4714
-
-
Bennett, L.H.1
Wang, P.S.2
Donahue, M.J.3
-
14
-
-
10044252267
-
Gradient field switching as a source for artifacts in MR imaging of metallic stents
-
A. Shenhav, and H. Azhari Gradient field switching as a source for artifacts in MR imaging of metallic stents Magn. Reson. Med. 52 2004 1465 1468
-
(2004)
Magn. Reson. Med.
, vol.52
, pp. 1465-1468
-
-
Shenhav, A.1
Azhari, H.2
-
15
-
-
20344395132
-
Radio frequency versus susceptibility effects of small conductive implants: A systematic MRI study on aneurysm clips at 1.5 and 3 T
-
U.A. Lauer, H. Graf, A. Berger, C.D. Claussen, and F. Schick Radio frequency versus susceptibility effects of small conductive implants: a systematic MRI study on aneurysm clips at 1.5 and 3 T Magn. Reson. Imaging 23 2005 563 569
-
(2005)
Magn. Reson. Imaging
, vol.23
, pp. 563-569
-
-
Lauer, U.A.1
Graf, H.2
Berger, A.3
Claussen, C.D.4
Schick, F.5
-
16
-
-
18044367901
-
RF artifacts caused by metallic implants or instruments which get more permanent at 3 T: An in vitro study
-
H. Graf, U.A. Lauer, A. Berger, and F. Schick RF artifacts caused by metallic implants or instruments which get more permanent at 3 T: an in vitro study Magn. Reson. Imaging 23 2005 493 499
-
(2005)
Magn. Reson. Imaging
, vol.23
, pp. 493-499
-
-
Graf, H.1
Lauer, U.A.2
Berger, A.3
Schick, F.4
-
17
-
-
14644435037
-
RF enhancement and shielding in MRI caused by conductive implants: Dependence on electrical parameters for a tube model
-
H. Graf, G. Steidle, U.A. Lauer, and F. Schick RF enhancement and shielding in MRI caused by conductive implants: dependence on electrical parameters for a tube model Med. Phys. 32 2005 337 342
-
(2005)
Med. Phys.
, vol.32
, pp. 337-342
-
-
Graf, H.1
Steidle, G.2
Lauer, U.A.3
Schick, F.4
-
18
-
-
31044434512
-
Effects on MRI due to altered RF Polarization near conductive implants or instruments
-
H. Graf, G. Steidle, P. Martirosian, U.A. Lauer, and F. Schick Effects on MRI due to altered RF Polarization near conductive implants or instruments Med. Phys. 33 2006 124 127
-
(2006)
Med. Phys.
, vol.33
, pp. 124-127
-
-
Graf, H.1
Steidle, G.2
Martirosian, P.3
Lauer, U.A.4
Schick, F.5
-
19
-
-
0000535886
-
Susceptibility artifacts in spin-echo and gradient-echo imaging
-
S. Posse, and W.P. Aue Susceptibility artifacts in spin-echo and gradient-echo imaging J. Magn. Reson. 88 1990 473 492
-
(1990)
J. Magn. Reson.
, vol.88
, pp. 473-492
-
-
Posse, S.1
Aue, W.P.2
-
20
-
-
0027159714
-
Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: The cylinder model revisited
-
C.J.G. Bakker, R. Bhagwandien, M.A. Moerland, and M. Fuderer Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: the cylinder model revisited Magn. Reson. Imaging 11 1993 539 548
-
(1993)
Magn. Reson. Imaging
, vol.11
, pp. 539-548
-
-
Bakker, C.J.G.1
Bhagwandien, R.2
Moerland, M.A.3
Fuderer, M.4
-
21
-
-
0021968447
-
NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities
-
M. O'Donnell, and W.A. Edelstein NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities Med. Phys. 12 1985 20 26
-
(1985)
Med. Phys.
, vol.12
, pp. 20-26
-
-
O'Donnell, M.1
Edelstein, W.A.2
-
23
-
-
84880921321
-
Three-dimensional quantification of susceptibility artifacts from various metals in magnetic resonance images
-
H. Imai, Y. Tanaka, N. Nomura, Y. Tsutsumi, H. Doi, Z. Kanno, K. Ohno, T. Ono, and T. Hanawa Three-dimensional quantification of susceptibility artifacts from various metals in magnetic resonance images Acta Biomater. 9 2013 8433 8439
-
(2013)
Acta Biomater.
, vol.9
, pp. 8433-8439
-
-
Imai, H.1
Tanaka, Y.2
Nomura, N.3
Tsutsumi, Y.4
Doi, H.5
Kanno, Z.6
Ohno, K.7
Ono, T.8
Hanawa, T.9
-
24
-
-
0028956620
-
Phase constrained encoding (PACE): A technique for MRI in large static field inhomogeneities
-
J.K. Kim, D.B. Plewes, and R.M. Henkelman Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities Magn. Reson. Med. 33 1995 497 505
-
(1995)
Magn. Reson. Med.
, vol.33
, pp. 497-505
-
-
Kim, J.K.1
Plewes, D.B.2
Henkelman, R.M.3
-
26
-
-
0023883943
-
The total inhomogeneity correction including chemical shift and susceptibility by view angle tipping
-
Z.H. Cho, D.J. Kim, and Y.K. Kim The total inhomogeneity correction including chemical shift and susceptibility by view angle tipping Med. Phys. 15 1988 7 11
-
(1988)
Med. Phys.
, vol.15
, pp. 7-11
-
-
Cho, Z.H.1
Kim, D.J.2
Kim, Y.K.3
-
27
-
-
0026925939
-
A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
-
H. Chang, and J.M. Fitzpatrick A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities IEEE Trans. Med. Imaging 11 1992 319 329
-
(1992)
IEEE Trans. Med. Imaging
, vol.11
, pp. 319-329
-
-
Chang, H.1
Fitzpatrick, J.M.2
-
28
-
-
84865511338
-
Simulation and verification of magnetic field gradient waveforms in the presence of a metallic vessel in magnetic resonance imaging
-
F.G. Goora, H. Han, B.G. Colpitts, and B.J. Balcom Simulation and verification of magnetic field gradient waveforms in the presence of a metallic vessel in magnetic resonance imaging IEEE Trans. Magn. 48 2012 2440 2448
-
(2012)
IEEE Trans. Magn.
, vol.48
, pp. 2440-2448
-
-
Goora, F.G.1
Han, H.2
Colpitts, B.G.3
Balcom, B.J.4
-
29
-
-
84878774766
-
Investigation of magnetic field gradient waveforms in the presence of a metallic vessel in magnetic resonance imaging through simulation
-
F.G. Goora, H. Han, M. Ouellette, B.G. Colpitts, and B.J. Balcom Investigation of magnetic field gradient waveforms in the presence of a metallic vessel in magnetic resonance imaging through simulation IEEE Trans. Magn. 49 2013 2920 2932
-
(2013)
IEEE Trans. Magn.
, vol.49
, pp. 2920-2932
-
-
Goora, F.G.1
Han, H.2
Ouellette, M.3
Colpitts, B.G.4
Balcom, B.J.5
-
30
-
-
0035172358
-
On the heating of linear conductive structures as guide wires and catheters in interventional MRI
-
W.R. Nitz, A. Oppelt, W. Renz, C. Manke, M. Lenhart, and J. Link On the heating of linear conductive structures as guide wires and catheters in interventional MRI J. Magn. Reson. Imaging 13 2001 105 114
-
(2001)
J. Magn. Reson. Imaging
, vol.13
, pp. 105-114
-
-
Nitz, W.R.1
Oppelt, A.2
Renz, W.3
Manke, C.4
Lenhart, M.5
Link, J.6
-
32
-
-
78149386027
-
Magnetic resonance imaging inside metallic vessels
-
H. Han, and B. Balcom Magnetic resonance imaging inside metallic vessels Meas. Sci. Technol. 21 2010 1 5
-
(2010)
Meas. Sci. Technol.
, vol.21
, pp. 1-5
-
-
Han, H.1
Balcom, B.2
-
33
-
-
80055073725
-
High pressure magnetic resonance imaging with metallic vessels
-
H. Han, M. Ouellette, B. MacMillan, F.G. Goora, R. MacGregor, D. Green, and B.J. Balcom High pressure magnetic resonance imaging with metallic vessels J. Magn. Reson. 213 2011 90 97
-
(2011)
J. Magn. Reson.
, vol.213
, pp. 90-97
-
-
Han, H.1
Ouellette, M.2
Macmillan, B.3
Goora, F.G.4
Macgregor, R.5
Green, D.6
Balcom, B.J.7
-
34
-
-
67649227120
-
Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: State of the art
-
P. Stradiotti, A. Curti, G. Castellazzi, and A. Zerbi Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art Eur. Spine. J. 18 2009 102 108
-
(2009)
Eur. Spine. J.
, vol.18
, pp. 102-108
-
-
Stradiotti, P.1
Curti, A.2
Castellazzi, G.3
Zerbi, A.4
-
35
-
-
0002312260
-
Sensitivity and resolution of constant-time imaging
-
S. Gravina, and D.G. Cory Sensitivity and resolution of constant-time imaging J. Magn. Reson. 104 1994 53 61
-
(1994)
J. Magn. Reson.
, vol.104
, pp. 53-61
-
-
Gravina, S.1
Cory, D.G.2
-
37
-
-
0344464740
-
Centric scan SPRITE magnetic resonance imaging
-
M. Halse, D.J. Goodyear, B. MacMillan, P. Szomolanyi, D. Matheson, and B.J. Balcom Centric scan SPRITE magnetic resonance imaging J. Magn. Reson. 165 2003 219 229
-
(2003)
J. Magn. Reson.
, vol.165
, pp. 219-229
-
-
Halse, M.1
Goodyear, D.J.2
Macmillan, B.3
Szomolanyi, P.4
Matheson, D.5
Balcom, B.J.6
-
38
-
-
34249857538
-
Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT
-
M.F. Lee, S. Kim, S.A. Lee, H.T. Song, Y.M. Huh, D.H. Kim, S.H. Han, and J.S. Suh Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT RadioGraphics 27 2007 791 803
-
(2007)
RadioGraphics
, vol.27
, pp. 791-803
-
-
Lee, M.F.1
Kim, S.2
Lee, S.A.3
Song, H.T.4
Huh, Y.M.5
Kim, D.H.6
Han, S.H.7
Suh, J.S.8
-
39
-
-
0034913209
-
Quantitative assessment of an MR technique for reducing metal artifact: Application to spin-echo imaging in a phantom
-
M.J. Lee, D.L. Janzen, P.L. Munk, A. MacKay, Q.S. Xiang, and A. MacGowen Quantitative assessment of an MR technique for reducing metal artifact: application to spin-echo imaging in a phantom Skeletal Radiol. 30 2001 398 401
-
(2001)
Skeletal Radiol.
, vol.30
, pp. 398-401
-
-
Lee, M.J.1
Janzen, D.L.2
Munk, P.L.3
Mackay, A.4
Xiang, Q.S.5
Macgowen, A.6
-
40
-
-
4544269792
-
Magnetic resonance imaging after total hip arthroplasty: Evaluation of periposthetic soft tissue
-
H.G. Potter, B.J. Nestor, C.M. Sofka, S.T. Ho, L.E. Peters, and E.A. Salyati Magnetic resonance imaging after total hip arthroplasty: evaluation of periposthetic soft tissue J. Bone Joint. Surg. Am. 86 2004 1947 1957
-
(2004)
J. Bone Joint. Surg. Am.
, vol.86
, pp. 1947-1957
-
-
Potter, H.G.1
Nestor, B.J.2
Sofka, C.M.3
Ho, S.T.4
Peters, L.E.5
Salyati, E.A.6
-
45
-
-
0030194949
-
Time domain electromagnetic field computation with finite difference methods
-
T. Weiland Time domain electromagnetic field computation with finite difference methods Int. J. Numer. Model. El. 9 1996 295 319
-
(1996)
Int. J. Numer. Model. El.
, vol.9
, pp. 295-319
-
-
Weiland, T.1
|