메뉴 건너뛰기




Volumn 52, Issue 6, 2004, Pages 1465-1468

Gradient field switching as a source for artifacts in MR imaging of metallic stents

Author keywords

Artifact; Eddy current; MRI; Stent

Indexed keywords

EDDY CURRENTS; STENTS;

EID: 10044252267     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20294     Document Type: Article
Times cited : (10)

References (12)
  • 1
    • 0035107929 scopus 로고    scopus 로고
    • MR imaging of vascular stents: Effects of susceptibility, flow, and radio frequency eddy-currents
    • Bartels LW, Smits HFM, Bakker CJG, Viergever MA. MR imaging of vascular stents: Effects of susceptibility, flow, and radio frequency eddy-currents. J Vasc Interv Radiol 2001;12:365-371.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 365-371
    • Bartels, L.W.1    Smits, H.F.M.2    Bakker, C.J.G.3    Viergever, M.A.4
  • 3
    • 0030703658 scopus 로고    scopus 로고
    • Potential risk and artifacts of MRI of self-expandable esophageal stent
    • Taal BG, Muller SH, Boot H, Koops W. Potential risk and artifacts of MRI of self-expandable esophageal stent. Gastro Endocr 1997;46:424-429.
    • (1997) Gastro Endocr , vol.46 , pp. 424-429
    • Taal, B.G.1    Muller, S.H.2    Boot, H.3    Koops, W.4
  • 4
    • 0033818667 scopus 로고    scopus 로고
    • MR imaging in the presence of vascular stents: A systematic assessment of artifacts for various stent orientations, sequence types, and field strengths
    • Klemm T, Duda S, Machann J, Seekamp-Rahn K, Schnieder L, Claussen CD, Schick F. MR imaging in the presence of vascular stents: A systematic assessment of artifacts for various stent orientations, sequence types, and field strengths. Magn Reson Imaging 2000;12:606-615.
    • (2000) Magn Reson Imaging , vol.12 , pp. 606-615
    • Klemm, T.1    Duda, S.2    Machann, J.3    Seekamp-Rahn, K.4    Schnieder, L.5    Claussen, C.D.6    Schick, F.7
  • 5
    • 0030697949 scopus 로고    scopus 로고
    • Calculation of electric fields induced near metal implants by magnetic resonance imaging switched gradient magnetic fields
    • Buechler DN, Durney CH, Christensen DA. Calculation of electric fields induced near metal implants by magnetic resonance imaging switched gradient magnetic fields. Magn Reson Imaging 1997;15:1157-1166.
    • (1997) Magn Reson Imaging , vol.15 , pp. 1157-1166
    • Buechler, D.N.1    Durney, C.H.2    Christensen, D.A.3
  • 6
    • 0027998049 scopus 로고
    • Cranio-orbital reconstruction: Safety and image quality of metallic implants on CT and MRI scanning
    • Sullivan PK, Smith JF, Rozzelle AA. Cranio-orbital reconstruction: Safety and image quality of metallic implants on CT and MRI scanning. Plast Recon Surg 1994;94:589-596.
    • (1994) Plast Recon Surg , vol.94 , pp. 589-596
    • Sullivan, P.K.1    Smith, J.F.2    Rozzelle, A.A.3
  • 8
    • 0037407468 scopus 로고    scopus 로고
    • Quantitative evaluation of susceptibility and shielding effects of Nitinol, Platinum, Cobalt-alloy, and stainless steel stents
    • Wang Y, Truong TN, Yen C, Bilecen D, Watts R, Trost DW, Prince MR. Quantitative evaluation of susceptibility and shielding effects of Nitinol, Platinum, Cobalt-alloy, and stainless steel stents. Magn Reson Med 2003;49:972-976.
    • (2003) Magn Reson Med , vol.49 , pp. 972-976
    • Wang, Y.1    Truong, T.N.2    Yen, C.3    Bilecen, D.4    Watts, R.5    Trost, D.W.6    Prince, M.R.7
  • 9
    • 0036135370 scopus 로고    scopus 로고
    • Improved lumen visualization in metallic vascular implants by reducing RF artifacts
    • Bartels LW, Bakker CJ, Viergever MA. Improved lumen visualization in metallic vascular implants by reducing RF artifacts. Magn Reson Med 2002;47:171-180.
    • (2002) Magn Reson Med , vol.47 , pp. 171-180
    • Bartels, L.W.1    Bakker, C.J.2    Viergever, M.A.3
  • 11
    • 0029184004 scopus 로고
    • Nonsusceptibility artifacts due to metallic objects in MR imaging
    • Camacho CR, Plewes DB, Henkelman RM. Nonsusceptibility artifacts due to metallic objects in MR imaging. J Magn Reson Imag 1995;5:75-88.
    • (1995) J Magn Reson Imag , vol.5 , pp. 75-88
    • Camacho, C.R.1    Plewes, D.B.2    Henkelman, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.