-
1
-
-
77954639776
-
Numerical model for estimating RF-induced heating on a pacemaker implant during MRI: Experimental validation
-
Mattei E, Calcagnini G, Censi F, Triventi M, Bartolini P,. Numerical model for estimating RF-induced heating on a pacemaker implant during MRI: experimental validation. IEEE Trans Biomed Eng 2010; 57: 2045-2052.
-
(2010)
IEEE Trans Biomed Eng
, vol.57
, pp. 2045-2052
-
-
Mattei, E.1
Calcagnini, G.2
Censi, F.3
Triventi, M.4
Bartolini, P.5
-
2
-
-
29344433261
-
MRI and implanted medical devices: Basic interactions with an emphasis on heating
-
Nyenhuis JA, Park SM, Kamondetdacha R, Amjad A, Shellock FG, Rezai AR,. MRI and implanted medical devices: basic interactions with an emphasis on heating. IEEE Trans Device Mater Reliabil 2005; 5: 467-480.
-
(2005)
IEEE Trans Device Mater Reliabil
, vol.5
, pp. 467-480
-
-
Nyenhuis, J.A.1
Park, S.M.2
Kamondetdacha, R.3
Amjad, A.4
Shellock, F.G.5
Rezai, A.R.6
-
3
-
-
35848946812
-
Calculation of MRI-induced heating of an implanted medical lead wire with an electric field transfer function
-
DOI 10.1002/jmri.21159
-
Park SM, Kamondetdacha R, Nyenhuis JA,. Calculation of MRI-induced heating of an implanted medical lead wire with an electric field transfer function. J Magn Reson Imaging 2007; 26: 1278-1285. (Pubitemid 350058295)
-
(2007)
Journal of Magnetic Resonance Imaging
, vol.26
, Issue.5
, pp. 1278-1285
-
-
Park, S.-M.1
Kamondetdacha, R.2
Nyenhuis, J.A.3
-
4
-
-
35848952083
-
Electromagnetic and modeling analyses of an implanted device at 3 and 7 tesla
-
DOI 10.1002/jmri.21148
-
Ibrahim TS, Tang L, Kangarlu A, Abraham R,. Electromagnetic and modeling analyses of an implanted device at 3 and 7 Tesla. J Magn Reson Imaging 2007; 26: 1362-1367. (Pubitemid 350058308)
-
(2007)
Journal of Magnetic Resonance Imaging
, vol.26
, Issue.5
, pp. 1362-1367
-
-
Ibrahim, T.S.1
Tang, L.2
Kangarlu, A.3
Abraham, R.4
-
5
-
-
0033945858
-
Heating around intravascular guidewires by resonating RF waves
-
DOI 10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.0.CO;2-T
-
Konings MK, Bartels LW, Smits HF, Bakker CJ,. Heating around intravascular guidewires by resonating RF waves. J Magn Reson Imaging 2000; 12: 79-85. (Pubitemid 30437267)
-
(2000)
Journal of Magnetic Resonance Imaging
, vol.12
, Issue.1
, pp. 79-85
-
-
Konings, M.K.1
Bartels, L.W.2
Smits, H.F.M.3
Bakker, C.J.G.4
-
6
-
-
0035172358
-
On the heating of linear conductive structures as guide wires and catheters in interventional MRI
-
DOI 10.1002/1522-2586(200101)13:1<105::AID-JMRI1016>3.0.CO;2-0
-
Nitz WR, Oppelt A, Renz W, Manke C, Lenhart M, Link J,. On the heating of linear conductive structures as guide wires and catheters in interventional MRI. J Magn Reson Imaging 2001; 13: 105-114. (Pubitemid 32044567)
-
(2001)
Journal of Magnetic Resonance Imaging
, vol.13
, Issue.1
, pp. 105-114
-
-
Nitz, W.R.1
Oppelt, A.2
Renz, W.3
Manke, C.4
Lenhart, M.5
Link, J.6
-
7
-
-
0033917568
-
Safety of MRI-guided endovascular guidewire applications
-
DOI 10.1002/1522-2586(200007)12:1<75::AID-JMRI8>3.0.CO;2-#
-
Liu CY, Farahani K, Lu DS, Duckwiler G, Oppelt A,. Safety of MRI-guided endovascular guidewire applications. J Magn Reson Imaging 2000; 12: 75-78. (Pubitemid 30437266)
-
(2000)
Journal of Magnetic Resonance Imaging
, vol.12
, Issue.1
, pp. 75-78
-
-
Liu, C.-Y.1
Farahani, K.2
Lu, D.S.K.3
Duckwiler, G.4
Oppelt, A.5
-
8
-
-
0033918247
-
Radiofrequency energy-induced heating during MR procedures: A review
-
DOI 10.1002/1522-2586(200007)12:1<30::AID-JMRI4>3.0.CO;2-S
-
Shellock FG,. Radiofrequency energy-induced heating during MR procedures: a review. J Magn Reson Imaging 2000; 12: 30-36. (Pubitemid 30437262)
-
(2000)
Journal of Magnetic Resonance Imaging
, vol.12
, Issue.1
, pp. 30-36
-
-
Shellock, F.G.1
-
10
-
-
0023706020
-
Heating effects of metallic implants by MRI examinations
-
Buchli R, Boesiger P, Meier D,. Heating effects of metallic implants by MRI examinations. Magn Reson Med 1988; 7: 255-261.
-
(1988)
Magn Reson Med
, vol.7
, pp. 255-261
-
-
Buchli, R.1
Boesiger, P.2
Meier, D.3
-
11
-
-
0030130690
-
Evaluation of inductively heated ferromagnetic alloy implants for therapeutic interstitial hyperthermia
-
DOI 10.1109/10.486260
-
Paulus JA, Richardson JS, Tucker RD, Park JB,. Evaluation of inductively heated ferromagnetic alloy implants for therapeutic interstitial hyperthermia. IEEE Trans Biom Eng 1996; 43: 406-413. (Pubitemid 26110397)
-
(1996)
IEEE Transactions on Biomedical Engineering
, vol.43
, Issue.4
, pp. 406-413
-
-
Paulus, J.A.1
Richardson, J.S.2
Tucker, R.D.3
Park, J.B.4
-
12
-
-
78649445084
-
Eddy current simulation in thick cylinders of finite length induced by coils of arbitrary geometry
-
Sanchez Lopez H, Poole M, Crozier S,. Eddy current simulation in thick cylinders of finite length induced by coils of arbitrary geometry. J Magn Reson 2010; 207: 251-261.
-
(2010)
J Magn Reson
, vol.207
, pp. 251-261
-
-
Sanchez Lopez, H.1
Poole, M.2
Crozier, S.3
-
13
-
-
35848951390
-
Heating of metallic implants and instruments induced by gradient switching in a 1.5-Tesla whole-body unit
-
DOI 10.1002/jmri.21157
-
Graf H, Steidle G, Schick F,. Heating of metallic implants and instruments induced by gradient switching in a 1.5 T whole body unit. J Magn Reson 2007; 26: 1328-1333. (Pubitemid 350058302)
-
(2007)
Journal of Magnetic Resonance Imaging
, vol.26
, Issue.5
, pp. 1328-1333
-
-
Graf, H.1
Steidle, G.2
Schick, F.3
|