메뉴 건너뛰기




Volumn 19, Issue 6, 2014, Pages 900-906

Pullout strength of thoracic pedicle screws improved with cortical bone ratio: a cadaveric study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; BONE STRENGTH; CADAVER; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORTICAL BONE; CORTICAL BONE RATIO; FEMALE; FIXATION FAILURE; HUMAN; HUMAN TISSUE; IN VITRO STUDY; MALE; MUSCULOSKELETAL SYSTEM PARAMETERS; PEDICLE SCREW; PULLOUT STRENGTH; THORACIC SPINE; THREE DIMENSIONAL IMAGING; TRABECULAR BONE; BIOMECHANICS; MATERIALS TESTING; MIDDLE AGED; OSTEOPOROSIS; PROCEDURES; RADIOGRAPHY; SPINE FUSION; VERTEBRA; VERY ELDERLY;

EID: 84912008912     PISSN: 09492658     EISSN: 14362023     Source Type: Journal    
DOI: 10.1007/s00776-014-0614-3     Document Type: Article
Times cited : (6)

References (29)
  • 1
    • 33750209491 scopus 로고    scopus 로고
    • An estimate of the worldwide prevalence and disability associated with osteoporotic fractures
    • COI: 1:STN:280:DC%2BD28nitVSksQ%3D%3D, PID: 16983459
    • Johnell O, Kanis JA. An estimate of the worldwide prevalence and disability associated with osteoporotic fractures. Osteoporos Int. 2006;17(12):1726–33.
    • (2006) Osteoporos Int , vol.17 , Issue.12 , pp. 1726-1733
    • Johnell, O.1    Kanis, J.A.2
  • 2
    • 0027484342 scopus 로고
    • Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members
    • COI: 1:STN:280:DyaK2c7gsFOqtA%3D%3D, (discussion 8–9)
    • Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976). 1993;18(15):2231–8 (discussion 8–9).
    • (1993) Spine (Phila Pa 1976) , vol.18 , Issue.15 , pp. 2231-2238
    • Esses, S.I.1    Sachs, B.L.2    Dreyzin, V.3
  • 3
    • 6644226483 scopus 로고    scopus 로고
    • Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients
    • COI: 1:STN:280:DC%2BD3srhsFSguw%3D%3D, PID: 14588296
    • Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K. Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J. 2001;1(6):402–7.
    • (2001) Spine J , vol.1 , Issue.6 , pp. 402-407
    • Okuyama, K.1    Abe, E.2    Suzuki, T.3    Tamura, Y.4    Chiba, M.5    Sato, K.6
  • 4
    • 84874407104 scopus 로고    scopus 로고
    • A biomechanical study of two different pedicle screw methods for fixation in osteoporotic and nonosteoporotic vertebrae
    • PID: 23327843
    • Higashino K, Kim JH, Horton WC, Hutton WC. A biomechanical study of two different pedicle screw methods for fixation in osteoporotic and nonosteoporotic vertebrae. J Surg Orthop Adv. 2012;21(4):198–203.
    • (2012) J Surg Orthop Adv , vol.21 , Issue.4 , pp. 198-203
    • Higashino, K.1    Kim, J.H.2    Horton, W.C.3    Hutton, W.C.4
  • 5
    • 84897879364 scopus 로고    scopus 로고
    • Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status
    • 748393, PID: 24724097
    • Shea TM, Laun J, Gonzalez-Blohm SA, Doulgeris JJ, Lee WE 3rd, Aghayev K, Vrionis FD. Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status. Biomed Res Int. 2014;2014:748393.
    • (2014) Biomed Res Int , vol.2014
    • Shea, T.M.1    Laun, J.2    Gonzalez-Blohm, S.A.3    Doulgeris, J.J.4    Lee, W.E.5    Aghayev, K.6    Vrionis, F.D.7
  • 6
    • 46749109567 scopus 로고    scopus 로고
    • Influence of thread design on pedicle screw fixation. Laboratory investigation
    • PID: 18590418
    • Krenn MH, Piotrowski WP, Penzkofer R, Augat P. Influence of thread design on pedicle screw fixation. Laboratory investigation. J Neurosurg Spine. 2008;9(1):90–5.
    • (2008) J Neurosurg Spine , vol.9 , Issue.1 , pp. 90-95
    • Krenn, M.H.1    Piotrowski, W.P.2    Penzkofer, R.3    Augat, P.4
  • 7
    • 77956412784 scopus 로고    scopus 로고
    • The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models
    • PID: 20558097
    • Patel PS, Shepherd DE, Hukins DW. The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models. Med Eng Phys. 2010;32(8):822–8.
    • (2010) Med Eng Phys , vol.32 , Issue.8 , pp. 822-828
    • Patel, P.S.1    Shepherd, D.E.2    Hukins, D.W.3
  • 9
    • 0026445667 scopus 로고
    • Anatomic and technical considerations of pedicle screw fixation
    • PID: 1395312
    • Weinstein JN, Rydevik BL, Rauschning W. Anatomic and technical considerations of pedicle screw fixation. Clin Orthop Relat Res. 1992;284:34–46.
    • (1992) Clin Orthop Relat Res , vol.284 , pp. 34-46
    • Weinstein, J.N.1    Rydevik, B.L.2    Rauschning, W.3
  • 11
    • 84865257199 scopus 로고    scopus 로고
    • Effects of screw and host factors on insertion torque and pullout strength
    • PID: 22149542
    • Shah AH, Behrents RG, Kim KB, Kyung HM, Buschang PH. Effects of screw and host factors on insertion torque and pullout strength. Angle Orthod. 2012;82(4):603–10.
    • (2012) Angle Orthod , vol.82 , Issue.4 , pp. 603-610
    • Shah, A.H.1    Behrents, R.G.2    Kim, K.B.3    Kyung, H.M.4    Buschang, P.H.5
  • 12
    • 34247637260 scopus 로고    scopus 로고
    • Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength
    • Burval DJ, McLain RF, Milks R, Inceoglu S. Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine (Phila Pa 1976). 2007;32(10):1077–83.
    • (2007) Spine (Phila Pa 1976) , vol.32 , Issue.10 , pp. 1077-1083
    • Burval, D.J.1    McLain, R.F.2    Milks, R.3    Inceoglu, S.4
  • 13
    • 84881178554 scopus 로고    scopus 로고
    • Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection
    • PID: 23602374
    • Helgeson MD, Kang DG, Lehman RA Jr, Dmitriev AE, Luhmann SJ. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection. Spine J. 2013;13(8):957–65.
    • (2013) Spine J , vol.13 , Issue.8 , pp. 957-965
    • Helgeson, M.D.1    Kang, D.G.2    Lehman, R.A.3    Dmitriev, A.E.4    Luhmann, S.J.5
  • 14
    • 0031925505 scopus 로고    scopus 로고
    • Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition
    • COI: 1:STN:280:DyaK1c3ms1amsw%3D%3D, PID: 9605215
    • Wilke HJ, Jungkunz B, Wenger K, Claes LE. Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition. Anat Rec. 1998;251(1):15–9.
    • (1998) Anat Rec , vol.251 , Issue.1 , pp. 15-19
    • Wilke, H.J.1    Jungkunz, B.2    Wenger, K.3    Claes, L.E.4
  • 15
    • 0023923301 scopus 로고
    • Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation
    • COI: 1:STN:280:DyaL1c3kvVOktA%3D%3D
    • Krag MH, Weaver DL, Beynnon BD, Haugh LD. Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine (Phila Pa 1976). 1988;13(1):27–32.
    • (1988) Spine (Phila Pa 1976) , vol.13 , Issue.1 , pp. 27-32
    • Krag, M.H.1    Weaver, D.L.2    Beynnon, B.D.3    Haugh, L.D.4
  • 16
    • 0024510133 scopus 로고
    • Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size
    • COI: 1:STN:280:DyaL1M3kt1ejtg%3D%3D
    • Misenhimer GR, Peek RD, Wiltse LL, Rothman SL, Widell EH Jr. Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine (Phila Pa 1976). 1989;14(4):367–72.
    • (1989) Spine (Phila Pa 1976) , vol.14 , Issue.4 , pp. 367-372
    • Misenhimer, G.R.1    Peek, R.D.2    Wiltse, L.L.3    Rothman, S.L.4    Widell, E.H.5
  • 17
    • 0030022014 scopus 로고    scopus 로고
    • Internal architecture of the thoracic pedicle. An anatomic study
    • COI: 1:STN:280:DyaK28zks1WrsA%3D%3D
    • Kothe R, O’Holleran JD, Liu W, Panjabi MM. Internal architecture of the thoracic pedicle. An anatomic study. Spine (Phila Pa 1976). 1996;21(3):264–70.
    • (1996) Spine (Phila Pa 1976) , vol.21 , Issue.3 , pp. 264-270
    • Kothe, R.1    O’Holleran, J.D.2    Liu, W.3    Panjabi, M.M.4
  • 19
    • 33750468294 scopus 로고    scopus 로고
    • Mechanical performance of cylindrical and dual core pedicle screws in calf and human vertebrae
    • COI: 1:STN:280:DC%2BD28njtlKqtQ%3D%3D, PID: 16865403
    • Lill CA, Schneider E, Goldhahn J, Haslemann A, Zeifang F. Mechanical performance of cylindrical and dual core pedicle screws in calf and human vertebrae. Arch Orthop Trauma Surg. 2006;126(10):686–94.
    • (2006) Arch Orthop Trauma Surg , vol.126 , Issue.10 , pp. 686-694
    • Lill, C.A.1    Schneider, E.2    Goldhahn, J.3    Haslemann, A.4    Zeifang, F.5
  • 21
    • 21844480606 scopus 로고    scopus 로고
    • Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses
    • PID: 16022991
    • Hsu CC, Chao CK, Wang JL, Hou SM, Tsai YT, Lin J. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res. 2005;23(4):788–94.
    • (2005) J Orthop Res , vol.23 , Issue.4 , pp. 788-794
    • Hsu, C.C.1    Chao, C.K.2    Wang, J.L.3    Hou, S.M.4    Tsai, Y.T.5    Lin, J.6
  • 22
    • 65249086162 scopus 로고    scopus 로고
    • Pedicle screw fixation strength: a biomechanical comparison between 4.5-mm and 5.5-mm diameter screws in osteoporotic upper thoracic vertebrae
    • PID: 19327262
    • Tsai KJ, Murakami H, Horton WC, Fei Q, Hutton WC. Pedicle screw fixation strength: a biomechanical comparison between 4.5-mm and 5.5-mm diameter screws in osteoporotic upper thoracic vertebrae. J Surg Orthop Adv. 2009;18(1):23–7.
    • (2009) J Surg Orthop Adv , vol.18 , Issue.1 , pp. 23-27
    • Tsai, K.J.1    Murakami, H.2    Horton, W.C.3    Fei, Q.4    Hutton, W.C.5
  • 23
    • 84862789565 scopus 로고    scopus 로고
    • Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study
    • PID: 22336467
    • Kim YY, Choi WS, Rhyu KW. Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study. Spine J. 2012;12(2):164–8.
    • (2012) Spine J , vol.12 , Issue.2 , pp. 164-168
    • Kim, Y.Y.1    Choi, W.S.2    Rhyu, K.W.3
  • 24
    • 80051783733 scopus 로고    scopus 로고
    • Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines
    • Pare PE, Chappuis JL, Rampersaud R, Agarwala AO, Perra JH, Erkan S, Wu C. Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines. Spine (Phila Pa 1976). 2011 Aug;36(18):E1210-4.
    • Spine (Phila Pa 1976) , vol.36 , Issue.18 , pp. E1210-E1214
    • Pare, P.E.1    Chappuis, J.L.2    Rampersaud, R.3    Agarwala, A.O.4    Perra, J.H.5    Erkan, S.6    Wu, C.7
  • 25
    • 83455238949 scopus 로고    scopus 로고
    • Pullout performance of self-tapping medical screws
    • 111002, PID: 22168734
    • Wu Z, Nassar SA, Yang X. Pullout performance of self-tapping medical screws. J Biomech Eng. 2011;133(11):111002.
    • (2011) J Biomech Eng , vol.133 , Issue.11
    • Wu, Z.1    Nassar, S.A.2    Yang, X.3
  • 26
    • 84878443605 scopus 로고    scopus 로고
    • Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae—A cadaveric study
    • PID: 23798753
    • Saraf SK, Singh RP, Singh V, Varma A. Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae—A cadaveric study. Indian J Orthop. 2013;47(3):238–43.
    • (2013) Indian J Orthop , vol.47 , Issue.3 , pp. 238-243
    • Saraf, S.K.1    Singh, R.P.2    Singh, V.3    Varma, A.4