메뉴 건너뛰기




Volumn 12, Issue 2, 2012, Pages 164-168

Assessment of pedicle screw pullout strength based on various screw designs and bone densities - An ex vivo biomechanical study

Author keywords

Biomechanical test; Bone density; Pedicle screw design; Pullout strength

Indexed keywords

POLYURETHAN FOAM;

EID: 84862789565     PISSN: 15299430     EISSN: 18781632     Source Type: Journal    
DOI: 10.1016/j.spinee.2012.01.014     Document Type: Article
Times cited : (119)

References (34)
  • 1
    • 33847466486 scopus 로고
    • A method of spinal fusion
    • Boucher HH. A method of spinal fusion. J Bone Joint Surg Br 1959;41:248-59.
    • (1959) J Bone Joint Surg Br , vol.41 , pp. 248-259
    • Boucher, H.H.1
  • 3
    • 78650294275 scopus 로고    scopus 로고
    • Instrumentation of the osteoporotic spine: Biomechanical and clinical considerations
    • Ponnusamy KE, Iyer S, Gupta G, et al. Instrumentation of the osteoporotic spine: biomechanical and clinical considerations. Spine J 2011;11:54-63.
    • (2011) Spine J , vol.11 , pp. 54-63
    • Ponnusamy, K.E.1    Iyer, S.2    Gupta, G.3
  • 4
    • 79956148660 scopus 로고    scopus 로고
    • Complications associated with posterior lumbar surgery
    • Cho W, Shimer AL, Shen FH. Complications associated with posterior lumbar surgery. Semin Spine Surg 2011;23:101-13.
    • (2011) Semin Spine Surg , vol.23 , pp. 101-113
    • Cho, W.1    Shimer, A.L.2    Shen, F.H.3
  • 5
    • 33748342332 scopus 로고    scopus 로고
    • Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65: Surgical considerations and treatment options in patients with poor bone quality
    • DOI 10.1097/01.brs.0000236893.65878.39, PII 0000763220060901100007
    • DeWald CJ, Stanley T. Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65. Surgical considerations and treatment options in patients with poor bone quality. Spine 2006;31:S144-51. (Pubitemid 44337837)
    • (2006) Spine , vol.31 , Issue.19 SUPPL.
    • DeWald, C.J.1    Stanley, T.2
  • 7
    • 0026201633 scopus 로고
    • Survivorship analysis of pedicle spinal instrumentation
    • McAfee PC, Weiland DJ, Carlow JJ. Survivorship analysis of pedicle spinal instrumentation. Spine 1991;16(8 Suppl):S422-7.
    • (1991) Spine , vol.16 , Issue.8 SUPPL.
    • McAfee, P.C.1    Weiland, D.J.2    Carlow, J.J.3
  • 8
    • 0027365874 scopus 로고
    • Stability of transpedicle screwing for the osteoporotic spine
    • Okuyama K, Sato K, Abe E, et al. Stability of transpedicle screwing for the osteoporotic spine. Spine 1993;18:2240-4.
    • (1993) Spine , vol.18 , pp. 2240-2244
    • Okuyama, K.1    Sato, K.2    Abe, E.3
  • 9
    • 0026505213 scopus 로고
    • Mechanical stability of the pedicle screw fixation systems for the lumbar spine
    • Yamagata M, Kitahara H, Minami S, et al. Mechanical stability of the pedicle screw fixation systems for the lumbar spine. Spine 1992; 17(3 Suppl):S51-4.
    • (1992) Spine , vol.17 , Issue.3 SUPPL.
    • Yamagata, M.1    Kitahara, H.2    Minami, S.3
  • 10
    • 0025988460 scopus 로고
    • An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
    • Soshi S, Shiba R, Konfi H, Murota K. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 1991;16:1335-41.
    • (1991) Spine , vol.16 , pp. 1335-1341
    • Soshi, S.1    Shiba, R.2    Konfi, H.3    Murota, K.4
  • 11
    • 0025903474 scopus 로고
    • Importance of bone mineral density in instrumented spine fusions
    • Wittenberg RM, Shea M, Swartz DE, et al. Importance of bone mineral density in instrumented spine fusions. Spine 1991;16:647-52.
    • (1991) Spine , vol.16 , pp. 647-652
    • Wittenberg, R.M.1    Shea, M.2    Swartz, D.E.3
  • 13
    • 0026089378 scopus 로고
    • Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae
    • George DC, Krag MH, Johnson CC, et al. Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine 1991;16:181-4.
    • (1991) Spine , vol.16 , pp. 181-184
    • George, D.C.1    Krag, M.H.2    Johnson, C.C.3
  • 14
    • 0031419970 scopus 로고    scopus 로고
    • Structural characteristics of the pedicle and its role in screw stability
    • Hirano T, Hasegawa K, Takahashi HE, et al. Structural characteristics of the pedicle and its role in screw stability. Spine 1997;22:2504-9.
    • (1997) Spine , vol.22 , pp. 2504-2509
    • Hirano, T.1    Hasegawa, K.2    Takahashi, H.E.3
  • 15
    • 0035851762 scopus 로고    scopus 로고
    • Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out
    • DOI 10.1016/S1529-9430(01)00119-X, PII S152994300100119X
    • Abshire BB, McLain RF, Valdevit A, Kambic HE. Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. Spine J 2001;1:408-14. (Pubitemid 33378110)
    • (2001) Spine Journal , vol.1 , Issue.6 , pp. 408-414
    • Abshire, B.B.1    McLain, R.F.2    Valdevit, A.3    Kambic, H.E.4
  • 16
    • 21844480606 scopus 로고    scopus 로고
    • Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses
    • Hsu CC, Chao CK, Wang JL, et al. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res 2005;23:788-94.
    • (2005) J Orthop Res , vol.23 , pp. 788-794
    • Hsu, C.C.1    Chao, C.K.2    Wang, J.L.3
  • 17
    • 41949110636 scopus 로고    scopus 로고
    • Increasing bending strength and pullout strength in conical pedicle screws: Biomechanical tests and finite element analyses
    • DOI 10.1097/BSD.0b013e318073cc4b, PII 0002472020080400000011
    • Chao CK, Hsu CC, Wang JL, Lin J. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses. J Spinal Disord Tech 2008;21:130-8. (Pubitemid 351507604)
    • (2008) Journal of Spinal Disorders and Techniques , vol.21 , Issue.2 , pp. 130-138
    • Chao, C.-K.1    Hsu, C.-C.2    Wang, J.-L.3    Lin, J.4
  • 18
    • 0034464574 scopus 로고    scopus 로고
    • Comparison of the in vitro holding strengths of conical and cylindrical pedicle screws in a fully inserted setting and backed out 180degrees
    • DOI 10.1097/00002517-200006000-00011
    • Lill CA, Schlegel U,Wahl D, Schneider E. Comparison of the in vitro holding strengths of conical and cylindrical pedicle screws in a fully inserted setting and backed out 180 degrees. J Spinal Disord 2000;13: 259-66. (Pubitemid 32201553)
    • (2000) Journal of Spinal Disorders , vol.13 , Issue.3 , pp. 259-266
    • Lill, C.A.1    Schlegel, U.2    Wahl, D.3    Schneider, E.4
  • 19
    • 0034888612 scopus 로고    scopus 로고
    • Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws
    • DOI 10.1097/00002517-200108000-00007
    • Ono A, Brown MD, Latta LL, et al. Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws. J Spinal Disord 2001;14:323-9. (Pubitemid 32758379)
    • (2001) Journal of Spinal Disorders , vol.14 , Issue.4 , pp. 323-329
    • Ono, A.1    Brown, M.D.2    Latta, L.L.3    Milne, E.L.4    Holmes, D.C.5
  • 20
    • 0029825385 scopus 로고    scopus 로고
    • Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone
    • DOI 10.1097/00007632-199611010-00004
    • Kwok AWL, Finkelstein JA, Woodside T, et al. Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone. Spine 1996;21:2429-34. (Pubitemid 26403456)
    • (1996) Spine , vol.21 , Issue.21 , pp. 2429-2434
    • Kwok, A.W.L.1    Finkelstein, J.A.2    Woodside, T.3    Hearn, T.C.4    Hu, R.W.5
  • 21
    • 46749109567 scopus 로고    scopus 로고
    • Influence of thread design on pedicle screw fixation: Laboratory investigation
    • DOI 10.3171/SPI/2008/9/7/090
    • Krenn MH, Piotrowski WP, Penzkofer R, Augat P. Influence of thread design on pedicle screw fixation: laboratory investigation. J Neurosurg Spine 2008;9:90-5. (Pubitemid 351948782)
    • (2008) Journal of Neurosurgery: Spine , vol.9 , Issue.1 , pp. 90-95
    • Krenn, M.H.1    Piotrowski, W.P.2    Penzkofer, R.3    Augat, P.4
  • 22
    • 0025351033 scopus 로고
    • Experimental pullout testing and comparison of variables in transpedicular screw fixation: A biomechanical study
    • Skinner R, Maybee J, Transfeldt E, et al. Experimental pullout testing and comparison of variables in transpedicular screw fixation: a biomechanical study. Spine 1990;15:195-200.
    • (1990) Spine , vol.15 , pp. 195-200
    • Skinner, R.1    Maybee, J.2    Transfeldt, E.3
  • 23
    • 0027344944 scopus 로고
    • Biomechanical testing of a new design for Schanz pedicle screws
    • Willett K, Hearn TC, Cuncins AV. Biomechanical testing of a new design for Schanz pedicle screws. J Orthop Trauma 1993;7:375-80.
    • (1993) J Orthop Trauma , vol.7 , pp. 375-380
    • Willett, K.1    Hearn, T.C.2    Cuncins, A.V.3
  • 24
    • 0022634973 scopus 로고
    • An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine: Design and testing
    • Krag MH, Beynnon BD, Pope MH, et al. An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine: design and testing. Clin Orthop Relat Res 1986;203:75-84.
    • (1986) Clin Orthop Relat Res , vol.203 , pp. 75-84
    • Krag, M.H.1    Beynnon, B.D.2    Pope, M.H.3
  • 26
    • 0028819606 scopus 로고
    • Lumbar pedicle screw salvage: Pullout testing of three different pedicle screw designs
    • McLain RF, Fry MF, Moseley TA, Sharkey NA. Lumbar pedicle screw salvage: pullout testing of three different pedicle screw designs. J Spinal Disord 1995;8:62-8.
    • (1995) J Spinal Disord , vol.8 , pp. 62-68
    • McLain, R.F.1    Fry, M.F.2    Moseley, T.A.3    Sharkey, N.A.4
  • 27
    • 75749134043 scopus 로고    scopus 로고
    • A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model
    • Chatzistergos PE, Magnissalis EA, Kourkoulis SK. A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model. Med Eng Phys 2010;32:145-54.
    • (2010) Med Eng Phys , vol.32 , pp. 145-154
    • Chatzistergos, P.E.1    Magnissalis, E.A.2    Kourkoulis, S.K.3
  • 28
    • 77955385364 scopus 로고    scopus 로고
    • The biomechanics of pedicle screw-based instrumentation
    • Cho W, Cho SK, Wu C. The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg Br 2010;92:1061-5.
    • (2010) J Bone Joint Surg Br , vol.92 , pp. 1061-1065
    • Cho, W.1    Cho, S.K.2    Wu, C.3
  • 29
    • 0025801025 scopus 로고
    • Triangulation of pedicular instrumentation. A biomechanical analysis
    • Ruland CM, McAfee PC, Warden KE, Cunningham BW. Triangulation of pedicular instrumentation. A biomechanical analysis. Spine 1991;16(6 Suppl):S270-6.
    • (1991) Spine , vol.16 , Issue.6 SUPPL.
    • Ruland, C.M.1    McAfee, P.C.2    Warden, K.E.3    Cunningham, B.W.4
  • 31
    • 84862813986 scopus 로고    scopus 로고
    • Standard specification for rigid polyurethane foam for use as a standard material for testing orthopaedic devices and instruments (F1839-08)
    • West Conshohocken, PA: ASTM International
    • Standard specification for rigid polyurethane foam for use as a standard material for testing orthopaedic devices and instruments (F1839-08). In: Annual book of ASTM standards, medical devices and services. West Conshohocken, PA: ASTM International, 2009.
    • (2009) Annual Book of ASTM Standards, Medical Devices and Services
  • 32
    • 84862803908 scopus 로고    scopus 로고
    • Standard specification and test methods for metallic medical bone screws (F543-07)
    • West Conshohocken, PA: ASTM International
    • Standard specification and test methods for metallic medical bone screws (F543-07). In: Annual book ofASTMstandards,medical devices and services. West Conshohocken, PA: ASTM International, 2009.
    • (2009) Annual Book OfASTMstandards,medical Devices and Services
  • 33
    • 11144274603 scopus 로고    scopus 로고
    • Pedicle screw fixation strength: Pullout versus insertional torque
    • DOI 10.1016/j.spinee.2004.02.006, PII S1529943004001147
    • Inceoglu S, Ferrara L, McLain RF. Pedicle screw fixation strength: pullout versus insertional torque. Spine J 2004;4:513-8. (Pubitemid 40029167)
    • (2004) Spine Journal , vol.4 , Issue.5 , pp. 513-518
    • Inceoglu, S.1    Ferrara, L.2    McLain, R.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.