메뉴 건너뛰기




Volumn 24, Issue 6, 2010, Pages 374-378

A comparison of screw insertion torque and pullout strength

Author keywords

Fixation strength; Insertion torque; Pull out strength

Indexed keywords

ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CANCELLOUS BONE; COMPRESSION; CONTROLLED STUDY; DEVICE REMOVAL; EQUIPMENT DESIGN; FRACTURE HEALING; INSTRUMENT VALIDATION; LOADING TEST; MATERIALS TESTING; OSTEOPOROSIS; PLATE FIXATION; PRIORITY JOURNAL; PROCESS MODEL; TORQUE; AUDIOVISUAL EQUIPMENT; COMPARATIVE STUDY; DEVICE FAILURE ANALYSIS; DEVICES; FRACTURE FIXATION; HUMAN;

EID: 77953166603     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3181c4a655     Document Type: Article
Times cited : (86)

References (15)
  • 1
    • 0030221045 scopus 로고    scopus 로고
    • Factors affecting the pullout strength of cancellous bone screws
    • Chapman JR, Harrington RM, Lee KM, et al. Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng. 1996;118:391-398.
    • (1996) J. Biomech Eng. , vol.118 , pp. 391-398
    • Chapman, J.R.1    Harrington, R.M.2    Lee, K.M.3
  • 3
    • 1542749983 scopus 로고    scopus 로고
    • Comparison of pullout strength of small-diameter cannulated and solid-core screws
    • Kissel CG, Friedersdorf SC, Foltz DS, et al. Comparison of pullout strength of small-diameter cannulated and solid-core screws. J Foot Ankle Surg. 2003;42:334-338.
    • (2003) J. Foot Ankle Surg. , vol.42 , pp. 334-338
    • Kissel, C.G.1    Friedersdorf, S.C.2    Foltz, D.S.3
  • 6
    • 33645728262 scopus 로고    scopus 로고
    • Stripping torque as a predictor of successful internal fracture fixation
    • Edwards TR, Tevelen G, English H, et al. Stripping torque as a predictor of successful internal fracture fixation. ANZ J Surg. 2005;75:1096-1099.
    • (2005) ANZ J. Surg. , vol.75 , pp. 1096-1099
    • Edwards, T.R.1    Tevelen, G.2    English, H.3
  • 7
    • 11144274603 scopus 로고    scopus 로고
    • Pedicle screw fixation strength: Pullout versus insertional torque
    • Inceoglu S, Ferrara L, McLain RF. Pedicle screw fixation strength: pullout versus insertional torque. Spine J. 2004;4:513-518.
    • (2004) Spine J. , vol.4 , pp. 513-518
    • Inceoglu, S.1    Ferrara, L.2    McLain, R.F.3
  • 8
    • 0029825385 scopus 로고    scopus 로고
    • Insertional torque and pullout strengths of conical and cylindrical pedicle screws in cadaveric bone
    • Kwok AW, Finkelstein JA, Woodside T, et al. Insertional torque and pullout strengths of conical and cylindrical pedicle screws in cadaveric bone. Spine. 1996;21:2429-2434.
    • (1996) Spine , vol.21 , pp. 2429-2434
    • Kwok, A.W.1    Finkelstein, J.A.2    Woodside, T.3
  • 9
    • 42049111628 scopus 로고    scopus 로고
    • The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone
    • Battula S, Schoenfeld AJ, Sahai V, et al. The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone. J Trauma. 2008;64:990-995.
    • (2008) J. Trauma , vol.64 , pp. 990-995
    • Battula, S.1    Schoenfeld, A.J.2    Sahai, V.3
  • 10
    • 33847146372 scopus 로고    scopus 로고
    • Effect of screw torque level on cortical bone pullout strength
    • Cleek TM, Reynolds KJ, Hearn TC. Effect of screw torque level on cortical bone pullout strength. J Orthop Trauma. 2007;21:117-123.
    • (2007) J. Orthop. Trauma , vol.21 , pp. 117-123
    • Cleek, T.M.1    Reynolds, K.J.2    Hearn, T.C.3
  • 11
    • 0035000837 scopus 로고    scopus 로고
    • Effect of insertion torque on bone screw pullout strength
    • Lawson KJ, Brems J. Effect of insertion torque on bone screw pullout strength. Orthopedics. 2001;24:451-454.
    • (2001) Orthopedics , vol.24 , pp. 451-454
    • Lawson, K.J.1    Brems, J.2
  • 12
    • 43449118717 scopus 로고    scopus 로고
    • Pullout strength and load to failure properties of self-tapping cortical screws in synthetic and cadaveric environments representative of healthy and osteoporotic bone
    • Schoenfeld AJ, Battula S, Sahai V, et al. Pullout strength and load to failure properties of self-tapping cortical screws in synthetic and cadaveric environments representative of healthy and osteoporotic bone. J Trauma. 2008;64:1302-1307.
    • (2008) J. Trauma , vol.64 , pp. 1302-1307
    • Schoenfeld, A.J.1    Battula, S.2    Sahai, V.3
  • 13
    • 63449111351 scopus 로고    scopus 로고
    • The effect of screw pullout rate on screw purchase in synthetic cancellous bone
    • Zdero R, Schemitsch EH. The effect of screw pullout rate on screw purchase in synthetic cancellous bone. J Biomech Eng. 2009;131:024501.
    • (2009) J. Biomech Eng. , vol.131 , pp. 024501
    • Zdero, R.1    Schemitsch, E.H.2
  • 15
    • 0035345047 scopus 로고    scopus 로고
    • Pullout properties of 3.5-mm AO/ASIF self-tapping and cortex screws in a uniform synthetic material and in canine bone
    • Murphy TP, Hill CM, Kapatkin AS, et al. Pullout properties of 3.5-mm AO/ASIF self-tapping and cortex screws in a uniform synthetic material and in canine bone. Vet Surg. 2001;30:253-260.
    • (2001) Vet Surg. , vol.30 , pp. 253-260
    • Murphy, T.P.1    Hill, C.M.2    Kapatkin, A.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.