메뉴 건너뛰기




Volumn 6, Issue 257, 2014, Pages

A neural interface provides long-term stable natural touch perception

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARM PROSTHESIS; ARTICLE; CASE REPORT; CONTROLLED STUDY; ELECTROSTIMULATION; FUNCTIONAL STATUS; GRIP STRENGTH; HUMAN; MALE; MIDDLE AGED; MOTOR CONTROL; MOTOR PERFORMANCE; PERIPHERAL NERVE; PERIPHERAL NERVE CUFF ELECTRODE; SENSORY FEEDBACK; SKIN ELECTRODE; TACTILE DISCRIMINATION; TACTILE FEEDBACK; TACTILE STIMULATION; ADVERSE EFFECTS; AGNOSIA; DISABLED PERSON; ELECTRODE IMPLANT; HAND; INNERVATION; LIMB PROSTHESIS; PARESTHESIA; PATHOPHYSIOLOGY; PHYSIOLOGY; PRESSURE; PROCEDURES; SENSATION; TOUCH; TRANSLATIONAL RESEARCH;

EID: 84908389400     PISSN: 19466234     EISSN: 19466242     Source Type: Journal    
DOI: 10.1126/scitranslmed.3008669     Document Type: Article
Times cited : (622)

References (29)
  • 1
    • 33747589222 scopus 로고    scopus 로고
    • The importance of the sense of touch in virtual and real environments
    • G. Robles-De-La-Torre, The importance of the sense of touch in virtual and real environments. IEEE Multimed. 13, 24-30 (2006).
    • (2006) IEEE Multimed. , vol.13 , pp. 24-30
    • Robles-De-La-Torre, G.1
  • 2
    • 0037322859 scopus 로고    scopus 로고
    • Importance of cutaneous feedback in maintaining a secure grip during manipulation of hand-held objects
    • A. S. Augurelle, A. M. Smith, T. Lejeune, J. L. Thonnard, Importance of cutaneous feedback in maintaining a secure grip during manipulation of hand-held objects. J. Neurophysiol. 89, 665-671 (2003).
    • (2003) J. Neurophysiol. , vol.89 , pp. 665-671
    • Augurelle, A.S.1    Smith, A.M.2    Lejeune, T.3    Thonnard, J.L.4
  • 3
    • 79952145177 scopus 로고    scopus 로고
    • Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
    • P. D. Marasco, K. Kim, J. E. Colgate, M. A. Peshkin, T. A. Kuiken, Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees. Brain 134, 747-758 (2011).
    • (2011) Brain , vol.134 , pp. 747-758
    • Marasco, P.D.1    Kim, K.2    Colgate, J.E.3    Peshkin, M.A.4    Kuiken, T.A.5
  • 6
    • 0019300990 scopus 로고
    • Closed-loop control in prosthetic systems: Historical perspective
    • D. S. Childress, Closed-loop control in prosthetic systems: Historical perspective. Ann. Biomed. Eng. 8, 293-303 (1980).
    • (1980) Ann. Biomed. Eng. , vol.8 , pp. 293-303
    • Childress, D.S.1
  • 7
    • 67651118209 scopus 로고    scopus 로고
    • P. Gallagher, D. Desmond, M. MacLachlan, Eds. Springer, London
    • C. D. Murray, in Psychoprosthetics, P. Gallagher, D. Desmond, M. MacLachlan, Eds. (Springer, London, 2008), pp. 119-129.
    • (2008) Psychoprosthetics , pp. 119-129
    • Murray, C.D.1
  • 8
    • 33749435189 scopus 로고    scopus 로고
    • Design and evaluation of a low-cost force feedback system for myoelectric prosthetic hands
    • C. Pylatiuk, A. Kargov, S. Schulz, Design and evaluation of a low-cost force feedback system for myoelectric prosthetic hands. J. Prosthet. Orthot. 18, 57-61 (2006).
    • (2006) J. Prosthet. Orthot. , vol.18 , pp. 57-61
    • Pylatiuk, C.1    Kargov, A.2    Schulz, S.3
  • 9
    • 84864217853 scopus 로고    scopus 로고
    • Vibro- and electrotactile user feedback on hand opening for myoelectric forearm prostheses
    • H. Witteveen, E. Droog, J. Rietman, P. Veltink, Vibro- and electrotactile user feedback on hand opening for myoelectric forearm prostheses. IEEE Trans. Biomed. Eng. 59, 2219-2226 (2012).
    • (2012) IEEE Trans. Biomed. Eng. , vol.59 , pp. 2219-2226
    • Witteveen, H.1    Droog, E.2    Rietman, J.3    Veltink, P.4
  • 10
    • 0016100050 scopus 로고
    • A sensory feedback system for an upper-limb amputation prosthesis
    • F. W. Clippinger, R. Avery, B. R. Titus, A sensory feedback system for an upper-limb amputation prosthesis. Bull. Prosthet. Res. Fall, 247-258 (1974).
    • (1974) Bull. Prosthet. Res. , vol.FALL , pp. 247-258
    • Clippinger, F.W.1    Avery, R.2    Titus, B.R.3
  • 11
    • 17744366189 scopus 로고    scopus 로고
    • Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees
    • G. S. Dhillon, T. B. Krüger, J. S. Sandhu, K. W. Horch, Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees. J. Neurophysiol. 93, 2625-2633 (2005).
    • (2005) J. Neurophysiol. , vol.93 , pp. 2625-2633
    • Dhillon, G.S.1    Krüger, T.B.2    Sandhu, J.S.3    Horch, K.W.4
  • 14
    • 0037934278 scopus 로고    scopus 로고
    • Chronic response of the rat sciatic nerve to the flat interface nerve electrode
    • D. J. Tyler, D. M. Durand, Chronic response of the rat sciatic nerve to the flat interface nerve electrode. Ann. Biomed. Eng. 31, 633-642 (2003).
    • (2003) Ann. Biomed. Eng. , vol.31 , pp. 633-642
    • Tyler, D.J.1    Durand, D.M.2
  • 16
    • 3142743126 scopus 로고    scopus 로고
    • Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs
    • G. S. Dhillon, S. M. Lawrence, D. T. Hutchinson, K. W. Horch, Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs. J. Hand Surg. Am. 29, 605-615 (2004).
    • (2004) J. Hand Surg. Am. , vol.29 , pp. 605-615
    • Dhillon, G.S.1    Lawrence, S.M.2    Hutchinson, D.T.3    Horch, K.W.4
  • 17
    • 0018908738 scopus 로고
    • Intensity of sensation related to activity of slowly adapting mechanoreceptive units in the human hand
    • B. Y. M. Knibestöl, A. B. Vallbo, Intensity of sensation related to activity of slowly adapting mechanoreceptive units in the human hand. J. Physiol. 300, 251-267 (1980).
    • (1980) J. Physiol. , vol.300 , pp. 251-267
    • Knibestöl, B.Y.M.1    Vallbo, A.B.2
  • 18
    • 80054062765 scopus 로고    scopus 로고
    • Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes
    • K. Horch, S. Meek, T. G. Taylor, D. T. Hutchinson, Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes. IEEE Trans. Neural Syst. Rehabil. Eng. 19, 483-489 (2011).
    • (2011) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.19 , pp. 483-489
    • Horch, K.1    Meek, S.2    Taylor, T.G.3    Hutchinson, D.T.4
  • 19
    • 84876907437 scopus 로고    scopus 로고
    • Learning multisensory integration and coordinate transformation via density estimation
    • J. G. Makin, M. R. Fellows, P. N. Sabes, Learning multisensory integration and coordinate transformation via density estimation. PLOS Comput. Biol. 9, e1003035 (2013).
    • (2013) PLOS Comput. Biol. , vol.9 , pp. e1003035
    • Makin, J.G.1    Fellows, M.R.2    Sabes, P.N.3
  • 20
    • 0033995616 scopus 로고    scopus 로고
    • Mechanisms of paresthesias arising from healthy axons
    • I. Mogyoros, H. Bostock, D. Burke, Mechanisms of paresthesias arising from healthy axons. Muscle Nerve 23, 310-320 (2000).
    • (2000) Muscle Nerve , vol.23 , pp. 310-320
    • Mogyoros, I.1    Bostock, H.2    Burke, D.3
  • 21
    • 0019121328 scopus 로고
    • Paraesthesiae from ectopic impulse generation in human sensory nerves
    • J. L. Ochoa, H. E. Torebjörk, Paraesthesiae from ectopic impulse generation in human sensory nerves. Brain 103, 835-853 (1980).
    • (1980) Brain , vol.103 , pp. 835-853
    • Ochoa, J.L.1    Torebjörk, H.E.2
  • 22
    • 56649096021 scopus 로고    scopus 로고
    • Discharges in human muscle spindle afferents during a key-pressing task
    • M. Dimitriou, B. B. Edin, Discharges in human muscle spindle afferents during a key-pressing task. J. Physiol. 586, 5455-5470 (2008).
    • (2008) J. Physiol. , vol.586 , pp. 5455-5470
    • Dimitriou, M.1    Edin, B.B.2
  • 23
    • 84863866682 scopus 로고    scopus 로고
    • Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode
    • M. A. Schiefer, D. J. Tyler, R. J. Triolo, Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode. J. Comput. Neurosci. 33, 179-190 (2012).
    • (2012) J. Comput. Neurosci. , vol.33 , pp. 179-190
    • Schiefer, M.A.1    Tyler, D.J.2    Triolo, R.J.3
  • 24
    • 77955147607 scopus 로고    scopus 로고
    • Topographical distribution of motor fascicles in the sciatic-tibial nerve of the rat
    • J. Badia, A. Pascual-Font, M. Vivó, E. Udina, X. Navarro, Topographical distribution of motor fascicles in the sciatic-tibial nerve of the rat. Muscle Nerve 42, 192-201 (2010).
    • (2010) Muscle Nerve , vol.42 , pp. 192-201
    • Badia, J.1    Pascual-Font, A.2    Vivó, M.3    Udina, E.4    Navarro, X.5
  • 25
    • 0026020306 scopus 로고
    • Fascicular topography of the median nerve: A computer based study to identify branching patterns
    • G. P. Watchmaker, C. a. Gumucio, R. E. Crandall, M. a. Vannier, P. M. Weeks, Fascicular topography of the median nerve: A computer based study to identify branching patterns. J. Hand Surg. Am. 16, 53-59 (1991).
    • (1991) J. Hand Surg. Am. , vol.16 , pp. 53-59
    • Watchmaker, G.P.1    Gumucio, C.A.2    Crandall, R.E.3    Vannier, M.A.4    Weeks, P.M.5
  • 26
    • 33846280527 scopus 로고    scopus 로고
    • Spatial clustering analysis in neuroanatomy: Applications of different approaches to motor nerve fiber distribution
    • D. Prodanov, N. Nagelkerke, E. Marani, Spatial clustering analysis in neuroanatomy: Applications of different approaches to motor nerve fiber distribution. J. Neurosci. Methods 160, 93-108 (2007).
    • (2007) J. Neurosci. Methods , vol.160 , pp. 93-108
    • Prodanov, D.1    Nagelkerke, N.2    Marani, E.3
  • 27
    • 0036874830 scopus 로고    scopus 로고
    • Electrode fracture rates and occurrences of infection and granuloma associated with percutaneous intramuscular electrodes in upper-limb functional electrical stimulation applications
    • J. S. Knutson, G. G. Naples, P. H. Peckham, M. W. Keith, Electrode fracture rates and occurrences of infection and granuloma associated with percutaneous intramuscular electrodes in upper-limb functional electrical stimulation applications. J. Rehabil. Res. Dev. 39, 671-683 (2002).
    • (2002) J. Rehabil. Res. Dev. , vol.39 , pp. 671-683
    • Knutson, J.S.1    Naples, G.G.2    Peckham, P.H.3    Keith, M.W.4
  • 29
    • 70449510356 scopus 로고    scopus 로고
    • Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity
    • K. H. Polasek, H. A. Hoyen, M. W. Keith, R. F. Kirsch, D. J. Tyler, Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity. IEEE Trans. Neural Syst. Rehabil. Eng. 17, 428-437 (2009).
    • (2009) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.17 , pp. 428-437
    • Polasek, K.H.1    Hoyen, H.A.2    Keith, M.W.3    Kirsch, R.F.4    Tyler, D.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.