메뉴 건너뛰기




Volumn 64, Issue 18, 2014, Pages 1950-1963

Imaging and functional testing to assess clinical and subclinical neurological events after transcatheter or surgical aortic valve replacement: A comprehensive review

Author keywords

neurological events; stroke; surgical aortic valve replacement; transcatheter aortic valve replacement

Indexed keywords

AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; ARTIFACT REDUCTION; BRAIN EMBOLISM; COGNITIVE DEFECT; DIFFUSION WEIGHTED IMAGING; DOPPLER ECHOGRAPHY; EMBOLIC PROTECTION FILTER; FUNCTIONAL ASSESSMENT; HUMAN; INTERMETHOD COMPARISON; INTRAOPERATIVE PERIOD; MEDICAL RESEARCH; MINI MENTAL STATE EXAMINATION; NAMED INVENTORIES, QUESTIONNAIRES AND RATING SCALES; NEUROIMAGING; NEUROLOGIC DISEASE; NEUROLOGIC EXAMINATION; NEUROPSYCHOLOGICAL TEST; PATIENT SELECTION; PROGNOSIS; REPEATABLE BATTERY FOR THE ASSESSMENT OF NEUROPSYCHOLOGICAL STATUS; REVIEW; SURGICAL APPROACH; SURGICAL TECHNIQUE; SYMPTOM; SYSTEMATIC REVIEW; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSCRANIAL DOPPLER; TRANSIENT ISCHEMIC ATTACK; AORTIC VALVE STENOSIS; POSTOPERATIVE COMPLICATIONS; PROCEDURES; REPRODUCIBILITY; STROKE;

EID: 84908374512     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2014.07.986     Document Type: Review
Times cited : (27)

References (69)
  • 1
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • PARTNER Trial Investigators
    • C.R. Smith, M.B. Leon, M.J. Mack PARTNER Trial Investigators Transcatheter versus surgical aortic-valve replacement in high-risk patients N Engl J Med 364 2011 2187 2198
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 2
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • PARTNER Trial Investigators
    • M.B. Leon, C.R. Smith, M. Mack PARTNER Trial Investigators Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 3
    • 84860381746 scopus 로고    scopus 로고
    • Risk of stroke after transcatheter aortic valve implantation (TAVI): A meta-analysis of 10,037 published patients
    • H. Eggebrecht, A. Schmermund, and T. Voigtlander Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients EuroIntervention 8 2012 129 138
    • (2012) EuroIntervention , vol.8 , pp. 129-138
    • Eggebrecht, H.1    Schmermund, A.2    Voigtlander, T.3
  • 4
    • 80855156727 scopus 로고    scopus 로고
    • Stroke associated with surgical and transcatheter treatment of aortic stenosis: A comprehensive review
    • B. Daneault, A.J. Kirtane, and S.K. Kodali Stroke associated with surgical and transcatheter treatment of aortic stenosis: a comprehensive review J Am Coll Cardiol 58 2011 2143 2150
    • (2011) J Am Coll Cardiol , vol.58 , pp. 2143-2150
    • Daneault, B.1    Kirtane, A.J.2    Kodali, S.K.3
  • 5
    • 84862181480 scopus 로고    scopus 로고
    • Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: A weighted meta-analysis of 3,519 patients from 16 studies
    • P. Genereux, S.J. Head, and N.M. Van Mieghem Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies J Am Coll Cardiol 59 2012 2317 2326
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2317-2326
    • Genereux, P.1    Head, S.J.2    Van Mieghem, N.M.3
  • 6
    • 84887950245 scopus 로고    scopus 로고
    • Outcomes following transcatheter aortic valve replacement in the United States
    • STS/ACC TVT Registry
    • M.J. Mack, J.M. Brennan, R. Brindis STS/ACC TVT Registry Outcomes following transcatheter aortic valve replacement in the United States JAMA 310 2013 2069 2077
    • (2013) JAMA , vol.310 , pp. 2069-2077
    • Mack, M.J.1    Brennan, J.M.2    Brindis, R.3
  • 7
    • 84899811656 scopus 로고    scopus 로고
    • Transcatheter aortic-valve replacement with a self-expanding prosthesis
    • U.S. CoreValve Clinical Investigators
    • D.H. Adams, J.J. Popma, M.J. Reardon U.S. CoreValve Clinical Investigators Transcatheter aortic-valve replacement with a self-expanding prosthesis N Engl J Med 370 2014 1790 1798
    • (2014) N Engl J Med , vol.370 , pp. 1790-1798
    • Adams, D.H.1    Popma, J.J.2    Reardon, M.J.3
  • 8
    • 84886620841 scopus 로고    scopus 로고
    • Novel approaches for prevention of stroke related to transcatheter aortic valve implantation
    • A. Ghanem, J. Kocurek, and J.M. Sinning Novel approaches for prevention of stroke related to transcatheter aortic valve implantation Exp Rev Cardiovasc Ther 11 2013 1311 1320
    • (2013) Exp Rev Cardiovasc Ther , vol.11 , pp. 1311-1320
    • Ghanem, A.1    Kocurek, J.2    Sinning, J.M.3
  • 9
    • 84901948187 scopus 로고    scopus 로고
    • Stroke after aortic valve surgery: Results from a prospective cohort
    • Determining Neurologic Outcomes From Valve Operations (DeNOVO) Investigators
    • S.R. Messé, M.A. Acker, S.E. Kasner Determining Neurologic Outcomes From Valve Operations (DeNOVO) Investigators Stroke after aortic valve surgery: results from a prospective cohort Circulation 129 2014 2253 2261
    • (2014) Circulation , vol.129 , pp. 2253-2261
    • Messé, S.R.1    Acker, M.A.2    Kasner, S.E.3
  • 10
    • 77949918630 scopus 로고    scopus 로고
    • Risk and fate of cerebral embolism after transfemoral aortic valve implantation: A prospective pilot study with diffusion-weighted magnetic resonance imaging
    • A. Ghanem, A. Muller, and C.P. Nahle Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging J Am Coll Cardiol 55 2010 1427 1432
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1427-1432
    • Ghanem, A.1    Muller, A.2    Nahle, C.P.3
  • 11
    • 78449244553 scopus 로고    scopus 로고
    • Front stroke, back stroke: The "emerging" interest of stroke in transcatheter aortic valve implantation
    • V.C. Babaliaros Front stroke, back stroke: the "emerging" interest of stroke in transcatheter aortic valve implantation J Am Coll Cardiol Intv 3 2010 1139 1140
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 1139-1140
    • Babaliaros, V.C.1
  • 12
    • 84878544469 scopus 로고    scopus 로고
    • Histopathology of embolic debris captured during transcatheter aortic valve replacement
    • N.M. Van Mieghem, M.E. Schipper, and E. Ladich Histopathology of embolic debris captured during transcatheter aortic valve replacement Circulation 127 2013 2194 2201
    • (2013) Circulation , vol.127 , pp. 2194-2201
    • Van Mieghem, N.M.1    Schipper, M.E.2    Ladich, E.3
  • 13
    • 0028280406 scopus 로고
    • Ultrasound detection of cerebral emboli in patients with prosthetic heart valves
    • D.G. Grosset, P. Cowburn, and D. Georgiadis Ultrasound detection of cerebral emboli in patients with prosthetic heart valves J Heart Valve Dis 3 1994 128 132
    • (1994) J Heart Valve Dis , vol.3 , pp. 128-132
    • Grosset, D.G.1    Cowburn, P.2    Georgiadis, D.3
  • 14
    • 0027938198 scopus 로고
    • High intensity transcranial Doppler signals (HITS) after prosthetic valve implantation
    • H.R. Müller, D. Burckhardt, and M. Casty High intensity transcranial Doppler signals (HITS) after prosthetic valve implantation J Heart Valve Dis 3 1994 602 606
    • (1994) J Heart Valve Dis , vol.3 , pp. 602-606
    • Müller, H.R.1    Burckhardt, D.2    Casty, M.3
  • 15
    • 0029039014 scopus 로고
    • Incidence and frequency of cerebral embolic signals in patients with a similar bileaflet mechanical heart valve
    • S.K. Brækken, D. Russell, and R. Brucher Incidence and frequency of cerebral embolic signals in patients with a similar bileaflet mechanical heart valve Stroke 26 1995 1225 1230
    • (1995) Stroke , vol.26 , pp. 1225-1230
    • Brækken, S.K.1    Russell, D.2    Brucher, R.3
  • 16
    • 0029961735 scopus 로고    scopus 로고
    • A novel technique for identification of Doppler microembolic signals based on the coincidence method: In vitro and in vivo evaluation
    • D. Georgiadis, J. Goeke, and M. Hill A novel technique for identification of Doppler microembolic signals based on the coincidence method: in vitro and in vivo evaluation Stroke 27 1996 683 686
    • (1996) Stroke , vol.27 , pp. 683-686
    • Georgiadis, D.1    Goeke, J.2    Hill, M.3
  • 17
    • 0342378182 scopus 로고    scopus 로고
    • Circulating microemboli in patients after aortic valve replacement with pulmonary autografts and mechanical valve prostheses
    • A. Nötzold, D.W. Droste, and G. Hagedorn Circulating microemboli in patients after aortic valve replacement with pulmonary autografts and mechanical valve prostheses Circulation 96 1997 1843 1846
    • (1997) Circulation , vol.96 , pp. 1843-1846
    • Nötzold, A.1    Droste, D.W.2    Hagedorn, G.3
  • 18
    • 0030724725 scopus 로고    scopus 로고
    • Influence of oxygen ventilation on Doppler microemboli signals in patients with artificial heart valves
    • D. Georgiadis, A. Wenzel, and D. Lehmann Influence of oxygen ventilation on Doppler microemboli signals in patients with artificial heart valves Stroke 28 1997 2189 2194
    • (1997) Stroke , vol.28 , pp. 2189-2194
    • Georgiadis, D.1    Wenzel, A.2    Lehmann, D.3
  • 19
    • 0031029189 scopus 로고    scopus 로고
    • Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid
    • M. Kaps, J. Hansen, and M. Weiher Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid Stroke 28 1997 322 325
    • (1997) Stroke , vol.28 , pp. 322-325
    • Kaps, M.1    Hansen, J.2    Weiher, M.3
  • 20
    • 0031786292 scopus 로고    scopus 로고
    • Intracranial high-intensity transient signals after homograft or mechanical aortic valve replacement
    • A.M. Lievense, S.L. Bakker, and D.W. Dippel Intracranial high-intensity transient signals after homograft or mechanical aortic valve replacement J Cardiovasc Surg (Torino) 39 1998 613 617
    • (1998) J Cardiovasc Surg (Torino) , vol.39 , pp. 613-617
    • Lievense, A.M.1    Bakker, S.L.2    Dippel, D.W.3
  • 21
    • 0031974093 scopus 로고    scopus 로고
    • Clinical correlations of Doppler microembolic signals in patients with prosthetic cardiac valves: Analysis of 580 cases
    • U. Sliwka, and D. Georgiadis Clinical correlations of Doppler microembolic signals in patients with prosthetic cardiac valves: analysis of 580 cases Stroke 29 1998 140 143
    • (1998) Stroke , vol.29 , pp. 140-143
    • Sliwka, U.1    Georgiadis, D.2
  • 22
    • 0031976799 scopus 로고    scopus 로고
    • Further evidence of gaseous embolic material in patients with artificial heart valves
    • D. Georgiadis, R.W. Baumgartner, and R. Karatschai Further evidence of gaseous embolic material in patients with artificial heart valves J Thorac Cardiovasc Surg 115 1998 808 810
    • (1998) J Thorac Cardiovasc Surg , vol.115 , pp. 808-810
    • Georgiadis, D.1    Baumgartner, R.W.2    Karatschai, R.3
  • 23
    • 0031660781 scopus 로고    scopus 로고
    • Mechanisms of cerebrovascular events as assessed by procoagulant activity, cerebral microemboli, and platelet microparticles in patients with prosthetic heart valves
    • T. Geiser, M. Sturzenegger, and U. Genewein Mechanisms of cerebrovascular events as assessed by procoagulant activity, cerebral microemboli, and platelet microparticles in patients with prosthetic heart valves Stroke 29 1998 1770 1777
    • (1998) Stroke , vol.29 , pp. 1770-1777
    • Geiser, T.1    Sturzenegger, M.2    Genewein, U.3
  • 24
    • 0032881981 scopus 로고    scopus 로고
    • Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients
    • A. Milano, A. D'Alfonso, and R. Codecasa Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients J Heart Valve Dis 8 1999 488 494
    • (1999) J Heart Valve Dis , vol.8 , pp. 488-494
    • Milano, A.1    D'Alfonso, A.2    Codecasa, R.3
  • 25
    • 0035783915 scopus 로고    scopus 로고
    • Microembolic signal counts increase during hyperbaric exposure in patients with prosthetic heart valves
    • R.W. Baumgartner, A. Frick, and C. Kremer Microembolic signal counts increase during hyperbaric exposure in patients with prosthetic heart valves J Thorac Cardiovasc Surg 122 2001 1142 1146
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 1142-1146
    • Baumgartner, R.W.1    Frick, A.2    Kremer, C.3
  • 26
    • 0036768622 scopus 로고    scopus 로고
    • Microembolic signals in patients with prosthetic valves: Relationship with the degree of anticoagulation
    • L. Stefani, G. Nuzzaci, and G. La Villa Microembolic signals in patients with prosthetic valves: relationship with the degree of anticoagulation Int J Angiol 11 2002 230 233
    • (2002) Int J Angiol , vol.11 , pp. 230-233
    • Stefani, L.1    Nuzzaci, G.2    La Villa, G.3
  • 27
    • 0036157218 scopus 로고    scopus 로고
    • Clinical relevance of intracranial high intensity transient signals in patients following prosthetic aortic valve replacement
    • T. Kofidis, S. Fischer, and R. Leyh Clinical relevance of intracranial high intensity transient signals in patients following prosthetic aortic valve replacement Eur J Cardiothorac Surg 21 2002 22 26
    • (2002) Eur J Cardiothorac Surg , vol.21 , pp. 22-26
    • Kofidis, T.1    Fischer, S.2    Leyh, R.3
  • 28
    • 1642482578 scopus 로고    scopus 로고
    • Neurological and neuropsychological examination and outcome after use of an intra-aortic filter device during cardiac surgery
    • S. Eifert, H. Reichenspurner, and T. Pfefferkorn Neurological and neuropsychological examination and outcome after use of an intra-aortic filter device during cardiac surgery Perfusion 18 Suppl 1 2003 55 60
    • (2003) Perfusion , vol.18 , pp. 55-60
    • Eifert, S.1    Reichenspurner, H.2    Pfefferkorn, T.3
  • 29
    • 0037213787 scopus 로고    scopus 로고
    • Impact of high intensity transient signals on the choice of mechanical aortic valve substitutes
    • J. Laas, S. Kseibi, and M. Perthel Impact of high intensity transient signals on the choice of mechanical aortic valve substitutes Eur J Cardiothorac Surg 23 2003 93 96
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 93-96
    • Laas, J.1    Kseibi, S.2    Perthel, M.3
  • 30
    • 24344450275 scopus 로고    scopus 로고
    • Neuropsychological deficits after mechanical aortic valve replacement
    • J. Uekermann, B. Suchan, and I. Daum Neuropsychological deficits after mechanical aortic valve replacement J Heart Valve Dis 14 2005 338 343
    • (2005) J Heart Valve Dis , vol.14 , pp. 338-343
    • Uekermann, J.1    Suchan, B.2    Daum, I.3
  • 31
    • 33645560410 scopus 로고    scopus 로고
    • Hemolysis, high-intensity transient signals (HITS) and hemodynamic results after aortic valve replacement with the Medtronic Hall Easy-Fit heart valve prosthesis
    • R.H. Warnecke, J. Laas, and H. Hecker Hemolysis, high-intensity transient signals (HITS) and hemodynamic results after aortic valve replacement with the Medtronic Hall Easy-Fit heart valve prosthesis J Heart Valve Dis 15 2006 174 179
    • (2006) J Heart Valve Dis , vol.15 , pp. 174-179
    • Warnecke, R.H.1    Laas, J.2    Hecker, H.3
  • 32
    • 33748342098 scopus 로고    scopus 로고
    • Reduction of gaseous microembolism during aortic valve replacement using a dynamic bubble trap
    • M. Schönburg, T. Ziegelhoeffer, and B. Kraus Reduction of gaseous microembolism during aortic valve replacement using a dynamic bubble trap Gen Physiol Biophys 25 2006 207 214
    • (2006) Gen Physiol Biophys , vol.25 , pp. 207-214
    • Schönburg, M.1    Ziegelhoeffer, T.2    Kraus, B.3
  • 33
    • 40149095420 scopus 로고    scopus 로고
    • Solid and gaseous cerebral microembolization after biologic and mechanical aortic valve replacement: Investigation with multirange and multifrequency transcranial Doppler ultrasound
    • L. Guerrieri Wolf, B.P. Choudhary, and Y. Abu-Omar Solid and gaseous cerebral microembolization after biologic and mechanical aortic valve replacement: investigation with multirange and multifrequency transcranial Doppler ultrasound J Thorac Cardiovasc Surg 135 2008 512 520
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 512-520
    • Guerrieri Wolf, L.1    Choudhary, B.P.2    Abu-Omar, Y.3
  • 34
    • 84866454957 scopus 로고    scopus 로고
    • Cerebral microembolization after bioprosthetic aortic valve replacement: Comparison of warfarin plus aspirin versus aspirin only
    • T. Al-Atassi, K. Lam, and M. Forgie Cerebral microembolization after bioprosthetic aortic valve replacement: comparison of warfarin plus aspirin versus aspirin only Circulation 126 2012 S239 S244
    • (2012) Circulation , vol.126 , pp. S239-S244
    • Al-Atassi, T.1    Lam, K.2    Forgie, M.3
  • 35
    • 84908370985 scopus 로고    scopus 로고
    • Transcranial Doppler analysis of embolic events during transcatheter aortic valve implantation (abstr)
    • W.T. Brinkman, K.L. Roper, and R. Kim Transcranial Doppler analysis of embolic events during transcatheter aortic valve implantation (abstr) J Am Coll Cardiol 58 2011 B194
    • (2011) J Am Coll Cardiol , vol.58 , pp. 194
    • Brinkman, W.T.1    Roper, K.L.2    Kim, R.3
  • 36
    • 80052893501 scopus 로고    scopus 로고
    • Transcranial Doppler sound detection of cerebral microembolism during transapical aortic valve implantation
    • T. Drews, M. Pasic, and S. Buz Transcranial Doppler sound detection of cerebral microembolism during transapical aortic valve implantation Thorac Cardiovasc Surg 59 2011 237 242
    • (2011) Thorac Cardiovasc Surg , vol.59 , pp. 237-242
    • Drews, T.1    Pasic, M.2    Buz, S.3
  • 37
    • 79961042044 scopus 로고    scopus 로고
    • Cerebral embolic exposure during transfemoral and transapical transcatheter aortic valve replacement
    • W.Y. Szeto, J.G. Augoustides, and N.D. Desai Cerebral embolic exposure during transfemoral and transapical transcatheter aortic valve replacement J Card Surg 26 2011 348 354
    • (2011) J Card Surg , vol.26 , pp. 348-354
    • Szeto, W.Y.1    Augoustides, J.G.2    Desai, N.D.3
  • 38
    • 84862339498 scopus 로고    scopus 로고
    • Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation
    • discussion 783-4
    • G. Erdoes, R. Basciani, and C. Huber Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation Eur J Cardiothorac Surg 41 2012 778 783 discussion 783-4
    • (2012) Eur J Cardiothorac Surg , vol.41 , pp. 778-783
    • Erdoes, G.1    Basciani, R.2    Huber, C.3
  • 39
    • 84865848038 scopus 로고    scopus 로고
    • Cerebral embolization during transcatheter aortic valve implantation: A transcranial Doppler study
    • P. Kahlert, F. Al-Rashid, and P. Dottger Cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study Circulation 126 2012 1245 1255
    • (2012) Circulation , vol.126 , pp. 1245-1255
    • Kahlert, P.1    Al-Rashid, F.2    Dottger, P.3
  • 40
    • 84855784380 scopus 로고    scopus 로고
    • Transcranial Doppler microembolic signals and serum marker evidence of brain injury during transcatheter aortic valve implantation
    • B. Reinsfelt, A. Westerlind, and D. Ioanes Transcranial Doppler microembolic signals and serum marker evidence of brain injury during transcatheter aortic valve implantation Acta Anaesthesiol Scand 56 2012 240 247
    • (2012) Acta Anaesthesiol Scand , vol.56 , pp. 240-247
    • Reinsfelt, B.1    Westerlind, A.2    Ioanes, D.3
  • 41
    • 84908377812 scopus 로고    scopus 로고
    • Cerebral embolization during transcatheter aortic valve implantation compared with surgical aortic valve replacement (abstr)
    • A. Alassar, D. Roy, and O. Valencia Cerebral embolization during transcatheter aortic valve implantation compared with surgical aortic valve replacement (abstr) Interact CardioVasc Thorac Surg 17 2013 S134 S135
    • (2013) Interact CardioVasc Thorac Surg , vol.17 , pp. S134-S135
    • Alassar, A.1    Roy, D.2    Valencia, O.3
  • 42
    • 84908365081 scopus 로고    scopus 로고
    • Neurocognitive outcome and cerebral embolic load during transcatheter aortic valve implantation (abstr)
    • J. Kempfert, T. Kobilke, and J. Blumenstein Neurocognitive outcome and cerebral embolic load during transcatheter aortic valve implantation (abstr) Thorac Cardiovasc Surg 2010 V58 V62
    • (2010) Thorac Cardiovasc Surg , pp. V58-V62
    • Kempfert, J.1    Kobilke, T.2    Blumenstein, J.3
  • 43
    • 1842471338 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging and neurobiochemical markers after aortic valve replacement: Implications for future neuroprotective trials?
    • E. Stolz, T. Gerriets, and A. Kluge Diffusion-weighted magnetic resonance imaging and neurobiochemical markers after aortic valve replacement: implications for future neuroprotective trials? Stroke 35 2004 888 892
    • (2004) Stroke , vol.35 , pp. 888-892
    • Stolz, E.1    Gerriets, T.2    Kluge, A.3
  • 44
    • 21244490831 scopus 로고    scopus 로고
    • Small ischemic brain lesions after cardiac valve replacement detected by diffusion-weighted magnetic resonance imaging: Relation to neurocognitive function
    • S.C. Knipp, N. Matatko, and M. Schlamann Small ischemic brain lesions after cardiac valve replacement detected by diffusion-weighted magnetic resonance imaging: relation to neurocognitive function Eur J Cardiothorac Surg 28 2005 88 96
    • (2005) Eur J Cardiothorac Surg , vol.28 , pp. 88-96
    • Knipp, S.C.1    Matatko, N.2    Schlamann, M.3
  • 45
    • 33646833240 scopus 로고    scopus 로고
    • Clinically silent cerebral ischemic events after cardiac surgery: Their incidence, regional vascular occurrence, and procedural dependence
    • T.F. Floyd, P.N. Shah, and C.C. Price Clinically silent cerebral ischemic events after cardiac surgery: their incidence, regional vascular occurrence, and procedural dependence Ann Thorac Surg 81 2006 2160 2166
    • (2006) Ann Thorac Surg , vol.81 , pp. 2160-2166
    • Floyd, T.F.1    Shah, P.N.2    Price, C.C.3
  • 46
    • 84908374456 scopus 로고    scopus 로고
    • Silent cerebral ischemia after transfemoral aortic valve implantation: A diffusion-weighted magnetic resonance imaging study (abstr)
    • V. Gasparetto, M. Napodano, and G. Rolma Silent cerebral ischemia after transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study (abstr) J of Am Coll Cardiol 56 2010 B110
    • (2010) J of Am Coll Cardiol , vol.56 , pp. 110
    • Gasparetto, V.1    Napodano, M.2    Rolma, G.3
  • 47
    • 84908364907 scopus 로고    scopus 로고
    • Cerebral magnetic resonance imaging unmasks subclinical microembolic cerebral lesions after transcatheter aortic valve implantation (abstr)
    • R.M. Maier, S. Blazek, and R. Vollmann Cerebral magnetic resonance imaging unmasks subclinical microembolic cerebral lesions after transcatheter aortic valve implantation (abstr) J Am Coll Cardiol 56 2010 B88
    • (2010) J Am Coll Cardiol , vol.56 , pp. 88
    • Maier, R.M.1    Blazek, S.2    Vollmann, R.3
  • 48
    • 78650573226 scopus 로고    scopus 로고
    • Cerebral embolism following transcatheter aortic valve implantation: Comparison of transfemoral and transapical approaches
    • J. Rodés-Cabau, E. Dumont, and R.H. Boone Cerebral embolism following transcatheter aortic valve implantation: comparison of transfemoral and transapical approaches J Am Coll Cardiol 57 2011 18 28
    • (2011) J Am Coll Cardiol , vol.57 , pp. 18-28
    • Rodés-Cabau, J.1    Dumont, E.2    Boone, R.H.3
  • 49
    • 84908371358 scopus 로고    scopus 로고
    • Evaluation of changes in geriatric symptoms and MRI- or CT-determined cerebral embolic lesions among patients undergoing transcatheter aortic valve implantation before and after procedure (abstr)
    • V. Eder, C. Ebner, and H. Koller Evaluation of changes in geriatric symptoms and MRI- or CT-determined cerebral embolic lesions among patients undergoing transcatheter aortic valve implantation before and after procedure (abstr) J Kardiol 19 2012 190
    • (2012) J Kardiol , vol.19 , pp. 190
    • Eder, V.1    Ebner, C.2    Koller, H.3
  • 50
    • 84155172936 scopus 로고    scopus 로고
    • Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: Assessment of predictive risk factors and the relationship to subsequent health status
    • T.A. Fairbairn, A.N. Mather, and P. Bijsterveld Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status Heart 98 2012 18 23
    • (2012) Heart , vol.98 , pp. 18-23
    • Fairbairn, T.A.1    Mather, A.N.2    Bijsterveld, P.3
  • 51
    • 84878328400 scopus 로고    scopus 로고
    • Prognostic value of cerebral injury following transfemoral aortic valve implantation
    • A. Ghanem, A. Muller, and J.M. Sinning Prognostic value of cerebral injury following transfemoral aortic valve implantation EuroIntervention 8 2013 1296 1306
    • (2013) EuroIntervention , vol.8 , pp. 1296-1306
    • Ghanem, A.1    Muller, A.2    Sinning, J.M.3
  • 52
    • 77649113087 scopus 로고    scopus 로고
    • Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: A diffusion-weighted magnetic resonance imaging study
    • P. Kahlert, S.C. Knipp, and M. Schlamann Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study Circulation 121 2010 870 878
    • (2010) Circulation , vol.121 , pp. 870-878
    • Kahlert, P.1    Knipp, S.C.2    Schlamann, M.3
  • 53
    • 79960233361 scopus 로고    scopus 로고
    • Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: Comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve
    • P. Astarci, D. Glineur, and J. Kefer Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve Eur J Cardiothorac Surg 40 2011 475 479
    • (2011) Eur J Cardiothorac Surg , vol.40 , pp. 475-479
    • Astarci, P.1    Glineur, D.2    Kefer, J.3
  • 54
    • 84908383370 scopus 로고    scopus 로고
    • Embolic cerebral insults and microbleeds after percutaneous aortic valve replacement and surgical aortic valve replacement detected by magnetic resonance imaging (abstr)
    • S. Ensminger, S. Ott, and S. Achenbach Embolic cerebral insults and microbleeds after percutaneous aortic valve replacement and surgical aortic valve replacement detected by magnetic resonance imaging (abstr) J Am Coll Cardiol 60 2012 B255
    • (2012) J Am Coll Cardiol , vol.60 , pp. 255
    • Ensminger, S.1    Ott, S.2    Achenbach, S.3
  • 55
    • 84880145665 scopus 로고    scopus 로고
    • Cerebral embolization during percutaneous valve implantation does not occur during balloon inflation valvuloplasty: Prospective diffusion-weighted brain MRI study
    • P. Astarci, J. Price, and D. Glineur Cerebral embolization during percutaneous valve implantation does not occur during balloon inflation valvuloplasty: prospective diffusion-weighted brain MRI study J Heart Valve Dis 22 2013 79 84
    • (2013) J Heart Valve Dis , vol.22 , pp. 79-84
    • Astarci, P.1    Price, J.2    Glineur, D.3
  • 56
    • 84908364680 scopus 로고    scopus 로고
    • Difference between cerebral embolic events following transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR): A diffusion weighted MRI study (abstr)
    • A. Uddin, T. Fairbairn, and I. Djoukhader Difference between cerebral embolic events following transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR): a diffusion weighted MRI study (abstr) J Cardiovasc Magn Res 15 2013 O59
    • (2013) J Cardiovasc Magn Res , vol.15 , pp. 59
    • Uddin, A.1    Fairbairn, T.2    Djoukhader, I.3
  • 57
    • 0022591771 scopus 로고
    • Neuropsychiatric complications after cardiopulmonary bypass: Cerebral protection by a barbiturate
    • N.A. Nussmeler, C. Arlund, and S. Slogoff Neuropsychiatric complications after cardiopulmonary bypass: cerebral protection by a barbiturate Anesthesiology 64 1986 165 170
    • (1986) Anesthesiology , vol.64 , pp. 165-170
    • Nussmeler, N.A.1    Arlund, C.2    Slogoff, S.3
  • 58
    • 0036327659 scopus 로고    scopus 로고
    • Cognitive deficit after aortic valve replacement
    • discussion 12
    • D. Zimpfer, M. Czerny, and J. Kilo Cognitive deficit after aortic valve replacement Ann Thorac Surg 74 2002 407 412 discussion 12
    • (2002) Ann Thorac Surg , vol.74 , pp. 407-412
    • Zimpfer, D.1    Czerny, M.2    Kilo, J.3
  • 59
    • 0037383617 scopus 로고    scopus 로고
    • Neurocognitive deficit following aortic valve replacement with biological/mechanical prosthesis
    • D. Zimpfer, J. Kilo, and M. Czerny Neurocognitive deficit following aortic valve replacement with biological/mechanical prosthesis Eur J Cardiothorac Surg 23 2003 544 551
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 544-551
    • Zimpfer, D.1    Kilo, J.2    Czerny, M.3
  • 60
    • 29144481850 scopus 로고    scopus 로고
    • Long-term neurocognitive function after mechanical aortic valve replacement
    • D. Zimpfer, M. Czerny, and P. Schuch Long-term neurocognitive function after mechanical aortic valve replacement Ann Thorac Surg 81 2006 29 33
    • (2006) Ann Thorac Surg , vol.81 , pp. 29-33
    • Zimpfer, D.1    Czerny, M.2    Schuch, P.3
  • 61
    • 84857188361 scopus 로고    scopus 로고
    • Influence of temperature management on neurocognitive function in biological aortic valve replacement. A prospective randomized trial
    • R. Fakin, D. Zimpfer, and G.H. Sodeck Influence of temperature management on neurocognitive function in biological aortic valve replacement. A prospective randomized trial J Cardiovasc Surg 53 2012 107 112
    • (2012) J Cardiovasc Surg , vol.53 , pp. 107-112
    • Fakin, R.1    Zimpfer, D.2    Sodeck, G.H.3
  • 62
    • 84878209670 scopus 로고    scopus 로고
    • Subjective impairment after cardiac surgeries: The relevance of postoperative cognitive decline in daily living
    • N. Schwarz, S. Kastaun, and M. Schoenburg Subjective impairment after cardiac surgeries: the relevance of postoperative cognitive decline in daily living Eur J Cardiothorac Surg 43 2013 e162 e166
    • (2013) Eur J Cardiothorac Surg , vol.43 , pp. e162-e166
    • Schwarz, N.1    Kastaun, S.2    Schoenburg, M.3
  • 63
    • 84892415794 scopus 로고    scopus 로고
    • Cognitive trajectory after transcatheter aortic valve implantation
    • A. Ghanem, J. Kocurek, and J.M. Sinning Cognitive trajectory after transcatheter aortic valve implantation Circ Cardiovasc Interv 6 2013 615 624
    • (2013) Circ Cardiovasc Interv , vol.6 , pp. 615-624
    • Ghanem, A.1    Kocurek, J.2    Sinning, J.M.3
  • 64
    • 84908370215 scopus 로고    scopus 로고
    • The effect of transcatheter aortic valve implantation (TAVI) on cognitive function (abstr)
    • M. Pelletier, V. Paddock, and H. Leblanc The effect of transcatheter aortic valve implantation (TAVI) on cognitive function (abstr) Can J Cardiol 29 2013 S220
    • (2013) Can J Cardiol , vol.29 , pp. 220
    • Pelletier, M.1    Paddock, V.2    Leblanc, H.3
  • 65
    • 84892407515 scopus 로고    scopus 로고
    • Neurological injury after transcatheter aortic valve implantation: Are the trees falling silently or is our hearing impaired?
    • J.N. Browndyke, and J.P. Mathew Neurological injury after transcatheter aortic valve implantation: are the trees falling silently or is our hearing impaired? Circ Cardiovasc Interv 6 2013 599 601
    • (2013) Circ Cardiovasc Interv , vol.6 , pp. 599-601
    • Browndyke, J.N.1    Mathew, J.P.2
  • 66
    • 84879305881 scopus 로고    scopus 로고
    • Transfemoral versus conventional aortic valve implantation - Early postoperative cognitive outcome
    • S. Holinski, P. Staebe, and T. Geyer Transfemoral versus conventional aortic valve implantation - early postoperative cognitive outcome Ann Thorac Cardiovasc Surg 19 2013 195 200
    • (2013) Ann Thorac Cardiovasc Surg , vol.19 , pp. 195-200
    • Holinski, S.1    Staebe, P.2    Geyer, T.3
  • 67
    • 84872715772 scopus 로고    scopus 로고
    • Cognitive function after transapical aortic valve implantation: A single-centre study with 3-month follow-up
    • S.C. Knipp, P. Kahlert, and D. Jokisch Cognitive function after transapical aortic valve implantation: a single-centre study with 3-month follow-up Interact Cardiovasc Thorac Surg 16 2013 116 122
    • (2013) Interact Cardiovasc Thorac Surg , vol.16 , pp. 116-122
    • Knipp, S.C.1    Kahlert, P.2    Jokisch, D.3
  • 68
    • 84872686855 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document (VARC-2)
    • Valve Academic Research Consortium-2 Consensus Document (VARC)-2
    • A.P. Kappetein, S.J. Head, P. Genereux Valve Academic Research Consortium-2 Consensus Document (VARC)-2 Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2) Eur J Cardiothorac Surg 42 2012 S45 S60
    • (2012) Eur J Cardiothorac Surg , vol.42 , pp. S45-S60
    • Kappetein, A.P.1    Head, S.J.2    Genereux, P.3
  • 69
    • 54249090690 scopus 로고    scopus 로고
    • Embolization during carotid angioplasty and stenting: What is the optimal method for detecting embolic debris and its sequelae?
    • B.G. DeRubertis Embolization during carotid angioplasty and stenting: what is the optimal method for detecting embolic debris and its sequelae? Perspect Vasc Surg Endovasc Ther 20 2008 260 269
    • (2008) Perspect Vasc Surg Endovasc Ther , vol.20 , pp. 260-269
    • Derubertis, B.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.