메뉴 건너뛰기




Volumn 41, Issue 4, 2012, Pages 778-784

Transcranial doppler-detected cerebral embolic load during transcatheter aortic valve implantation

Author keywords

Aortic valve stenosis; Cerebral embolism; High intensity transient signals; Neurocognitive impairment; Transcatheter aortic valve implantation; Transcranial doppler ultrasound

Indexed keywords

AGED; ARTICLE; BRAIN EMBOLISM; CEREBROVASCULAR ACCIDENT; CLINICAL ARTICLE; COGNITIVE DEFECT; DEATH; DELIRIUM; DOPPLER ECHOGRAPHY; FEMALE; HUMAN; INCIDENCE; MALE; MORTALITY; OBSERVATIONAL STUDY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; PROSPECTIVE STUDY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSLUMINAL VALVULOPLASTY; VALVULOPLASTY; AORTA VALVE STENOSIS; ECHOGRAPHY; HEART CATHETERIZATION; HEART VALVE REPLACEMENT; METHODOLOGY; MINIMALLY INVASIVE SURGERY; PATIENT MONITORING;

EID: 84862339498     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1093/ejcts/ezr068     Document Type: Article
Times cited : (104)

References (25)
  • 1
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description
    • Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002; 106:3006-8.
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3    Borenstein, N.4    Tron, C.5    Bauer, F.6
  • 2
    • 77958594295 scopus 로고    scopus 로고
    • PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG et al., PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010;363:1597-607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3    Miller, D.C.4    Moses, J.W.5    Svensson, L.G.6
  • 3
    • 78649695272 scopus 로고    scopus 로고
    • Usefulness of percutaneous aortic valve implantation to improve quality of life in patients >80 years of age
    • Bekeredijan R, Krumsdorf U, Chorianopoulos E, Kallenbach K, Karck M, Katus HA et al. Usefulness of percutaneous aortic valve implantation to improve quality of life in patients >80 years of age. Am J Cardiol 2010; 106:1777-81.
    • (2010) Am J Cardiol , vol.106 , pp. 1777-1781
    • Bekeredijan, R.1    Krumsdorf, U.2    Chorianopoulos, E.3    Kallenbach, K.4    Karck, M.5    Katus, H.A.6
  • 4
    • 78449256676 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: predictors of procedural success-the Siegburg-Bern experience
    • Buellesfeld L, Wenaweser P, Gerckens U, Mueller R, Sauren B, Latsios G et al. Transcatheter aortic valve implantation: predictors of procedural success-the Siegburg-Bern experience. Eur Heart J 2010;31:984-91.
    • (2010) Eur Heart J , vol.31 , pp. 984-991
    • Buellesfeld, L.1    Wenaweser, P.2    Gerckens, U.3    Mueller, R.4    Sauren, B.5    Latsios, G.6
  • 5
    • 0037433650 scopus 로고    scopus 로고
    • Silent and apparent cerebral embolism after retrograde catheterisation of the aortic valve in valvular stenosis: a prospective, randomised study
    • Omran H, Schmidt H, Hackenbroch M, Illien S, Bernhardt P, von der Recke G et al. Silent and apparent cerebral embolism after retrograde catheterisation of the aortic valve in valvular stenosis: a prospective, randomised study. Lancet 2003;361:1241-6.
    • (2003) Lancet , vol.361 , pp. 1241-1246
    • Omran, H.1    Schmidt, H.2    Hackenbroch, M.3    Illien, S.4    Bernhardt, P.5    Recke, G.V.D.6
  • 6
    • 0036644998 scopus 로고    scopus 로고
    • Stroke complicating percutaneous coronary interventions: incidence, predictors, and prognostic implications
    • Fuchs S, Stabile E, Kinnaird TD, Mintz GS, Gruberg L, Canos DA et al. Stroke complicating percutaneous coronary interventions: incidence, predictors, and prognostic implications. Circulation 2002;106:86-91.
    • (2002) Circulation , vol.106 , pp. 86-91
    • Fuchs, S.1    Stabile, E.2    Kinnaird, T.D.3    Mintz, G.S.4    Gruberg, L.5    Canos, D.A.6
  • 8
    • 79958151944 scopus 로고    scopus 로고
    • Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes
    • Wenaweser P, Pilgrim T, Roth N, Kadner A, Stortecky S, Kalesan B et al. Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes. Am Heart J 2011;161:1114-24.
    • (2011) Am Heart J , vol.161 , pp. 1114-1124
    • Wenaweser, P.1    Pilgrim, T.2    Roth, N.3    Kadner, A.4    Stortecky, S.5    Kalesan, B.6
  • 9
    • 70349196461 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications
    • Masson JB, Kovac J, Schuler G, Ye J, Cheung A, Kapadia S et al. Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. JACC Cardiovasc Interv 2009;2:811-20.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 811-820
    • Masson, J.B.1    Kovac, J.2    Schuler, G.3    Ye, J.4    Cheung, A.5    Kapadia, S.6
  • 10
    • 79958204372 scopus 로고    scopus 로고
    • PARTNER Trial Investigators. Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG et al., PARTNER Trial Investigators. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 2011;364:2187-98.
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3    Miller, D.C.4    Moses, J.W.5    Svensson, L.G.6
  • 11
    • 78650573226 scopus 로고    scopus 로고
    • Cerebral embolism following transcatheter aortic valve implantation: comparison of transfemoral and transapical approaches
    • Rodes-Cabau J, Dumont E, Boone RH, Larose E, Bagur R, Gurvitch R et al. Cerebral embolism following transcatheter aortic valve implantation: comparison of transfemoral and transapical approaches. J Am Coll Cardiol 2011;57:18-28.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 18-28
    • Rodes-cabau, J.1    Dumont, E.2    Boone, R.H.3    Larose, E.4    Bagur, R.5    Gurvitch, R.6
  • 12
    • 77649113087 scopus 로고    scopus 로고
    • Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study
    • Kahlert P, Knipp SC, Schlamann M, Thielmann M, Al-Rashid F, Weber M et al. Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study. Circulation 2010;121:870-8.
    • (2010) Circulation , vol.121 , pp. 870-878
    • Kahlert, P.1    Knipp, S.C.2    Schlamann, M.3    Thielmann, M.4    Al-rashid, F.5    Weber, M.6
  • 13
    • 77949918630 scopus 로고    scopus 로고
    • Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusionweighted magnetic resonance imaging
    • Ghanem A, Müller A, Nähle CP, Kocurek J, Werner N, Hammerstingl C et al. Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusionweighted magnetic resonance imaging. J Am Coll Cardiol 2010;55: 1427-32.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1427-1432
    • Ghanem, A.1    Müller, A.2    Nähle, C.P.3    Kocurek, J.4    Werner, N.5    Hammerstingl, C.6
  • 14
    • 78449263604 scopus 로고    scopus 로고
    • Embolic cerebral insults after transapical aortic valve implantation detected by magnetic resonance imaging
    • Arnold M, Schulz-Heise S, Achenbach S, Ott S, Dörfler A, Ropers D et al. Embolic cerebral insults after transapical aortic valve implantation detected by magnetic resonance imaging. J Am Coll Cardiol Interv 2010; 3:1126-32.
    • (2010) J Am Coll Cardiol Interv , vol.3 , pp. 1126-1132
    • Arnold, M.1    Schulz-heise, S.2    Achenbach, S.3    Ott, S.4    Dörfler, A.5    Ropers, D.6
  • 15
    • 79953058678 scopus 로고    scopus 로고
    • American Society of Neuropsychologic Monitoring and American Society of Neuroimaging joint guidelines for transcranial Doppler ultrasonic monitoring
    • Edmonds HL Jr, Isley MR, Sloan TB, Alexandrov AV, Razumovsky AY. American Society of Neuropsychologic Monitoring and American Society of Neuroimaging joint guidelines for transcranial Doppler ultrasonic monitoring. J Neuroimaging 2011;21:177-83.
    • (2011) J Neuroimaging , vol.21 , pp. 177-183
    • Edmonds Jr., H.L.1    Isley, M.R.2    Sloan, T.B.3    Alexandrov, A.V.4    Razumovsky, A.Y.5
  • 16
    • 84863769122 scopus 로고    scopus 로고
    • for the American Society of Neuroimaging Practice Guidelines Committee. Practice standards for transcranial Doppler (TCD) ultrasound. Part II. Clinical Indications and expected outcomes
    • doi:10.1111/j.1552-6569.2010.00523.x
    • Alexandrov AV, Sloan MA, Tegeler CH, Newell DN, Lumsden A, Garami Z et al., for the American Society of Neuroimaging Practice Guidelines Committee. Practice standards for transcranial Doppler (TCD) ultrasound. Part II. Clinical Indications and expected outcomes. J Neuroimag doi:10.1111/j.1552-6569.2010.00523.x.
    • J Neuroimag
    • Alexandrov, A.V.1    Sloan, M.A.2    Tegeler, C.H.3    Newell, D.N.4    Lumsden, A.5    Garami, Z.6
  • 17
    • 0029041693 scopus 로고
    • Basic identification criteria of Doppler microembolic signals. Consensus Committee of the Ninth International Cerebral Hemodynamic Symposium
    • Basic identification criteria of Doppler microembolic signals. Consensus Committee of the Ninth International Cerebral Hemodynamic Symposium. Stroke 1995;26:1123.
    • (1995) Stroke , vol.26 , pp. 1123
  • 19
    • 80052893501 scopus 로고    scopus 로고
    • Transcranial Doppler sound detection of cerebral microembolism during transapical aortic valve implantation
    • Drews T, Pasic M, Buz S, Unbehaun A, Dreysse S, Kukucka M et al. Transcranial Doppler sound detection of cerebral microembolism during transapical aortic valve implantation. Thorac Cardiovasc Surg 2011;59: 237-42.
    • (2011) Thorac Cardiovasc Surg , vol.59 , pp. 237-242
    • Drews, T.1    Pasic, M.2    Buz, S.3    Unbehaun, A.4    Dreysse, S.5    Kukucka, M.6
  • 20
    • 34347328186 scopus 로고    scopus 로고
    • Risk of acute brain injury related to cerebral microembolism during cardiac catheterization performed by right upper limb arterial access
    • Hamon M, Gomes S, Clergeau MR, Fradin S, Morello R, Hamon M. Risk of acute brain injury related to cerebral microembolism during cardiac catheterization performed by right upper limb arterial access. Stroke 2007;38:2176-9.
    • (2007) Stroke , vol.38 , pp. 2176-2179
    • Hamon, M.1    Gomes, S.2    Clergeau, M.R.3    Fradin, S.4    Morello, R.5    Hamon, M.6
  • 21
    • 50349088976 scopus 로고    scopus 로고
    • Periprocedural stroke and cardiac catheterization
    • Hamon M, Baron JC, Viader F, Hamon M. Periprocedural stroke and cardiac catheterization. Circulation 2008;118:678-83.
    • (2008) Circulation , vol.118 , pp. 678-683
    • Hamon, M.1    Baron, J.C.2    Viader, F.3    Hamon, M.4
  • 22
    • 33846361015 scopus 로고    scopus 로고
    • Neurocognitive function and cerebral emboli: randomized study of on-pump versus off-pump coronary artery bypass surgery
    • Motallebzadeh R, Bland JM, Markus HS, Kaski JC, Jahangiri M. Neurocognitive function and cerebral emboli: randomized study of on-pump versus off-pump coronary artery bypass surgery. Ann Thorac Surg 2007;83:475-82.
    • (2007) Ann Thorac Surg , vol.83 , pp. 475-482
    • Motallebzadeh, R.1    Bland, J.M.2    Markus, H.S.3    Kaski, J.C.4    Jahangiri, M.5
  • 23
    • 70349563897 scopus 로고    scopus 로고
    • The effects of cardiopulmonary bypass on the number of cerebral microemboli and the incidence of cognitive dysfunction after coronary artery bypass graft surgery
    • Liu YH, Wang DX, Li LH, Wu XM, Shan GJ, Su Y et al. The effects of cardiopulmonary bypass on the number of cerebral microemboli and the incidence of cognitive dysfunction after coronary artery bypass graft surgery. Anesth Analg 2009;109:1013-22.
    • (2009) Anesth Analg , vol.109 , pp. 1013-1022
    • Liu, Y.H.1    Wang, D.X.2    Li, L.H.3    Wu, X.M.4    Shan, G.J.5    Su, Y.6
  • 24
    • 76349095980 scopus 로고    scopus 로고
    • Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trial
    • Gerriets T, Schwarz N, Sammer G, Baehr J, Stolz E, Kaps M et al. Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trial. Eur Heart J 2010;31:360-8.
    • (2010) Eur Heart J , vol.31 , pp. 360-368
    • Gerriets, T.1    Schwarz, N.2    Sammer, G.3    Baehr, J.4    Stolz, E.5    Kaps, M.6
  • 25
    • 33750086340 scopus 로고    scopus 로고
    • Short-term changes in cerebral activity in on-pump and off-pump cardiac surgery defined by functional magnetic resonance imaging and their relationship to microembolization
    • Abu Omar Y, Cader S, Guerrieri Wolf L, Pigott D, Matthews PM, Taggart DP. Short-term changes in cerebral activity in on-pump and off-pump cardiac surgery defined by functional magnetic resonance imaging and their relationship to microembolization. J Thorac Cardiovasc Surg 2006; 132:1119-25.
    • (2006) J Thorac Cardiovasc Surg , vol.132 , pp. 1119-1125
    • Omar, Y.A.1    Cader, S.I.2    Wolf, L.G.3    Pigott, D.4    Matthews, P.M.5    Taggart, D.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.