메뉴 건너뛰기




Volumn 40, Issue 2, 2011, Pages 475-479

Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: Comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve

Author keywords

Cerebral embolization; Diffusion weighted magnetic resonance; Trans catheter aortic valve

Indexed keywords

AGED; ARTICLE; ASCENDING AORTA; BRAIN DAMAGE; BRAIN EMBOLISM; CLINICAL ARTICLE; COMPARATIVE EFFECTIVENESS; CONTROLLED STUDY; DIFFUSION WEIGHTED IMAGING; ECHO FLUID ATTENUATED INVERSION RECOVERY SEQUENCE; FEMALE; HEART PROTECTION; HUMAN; INTERMETHOD COMPARISON; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; STERNOTOMY; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 79960233361     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1016/j.ejcts.2010.11.070     Document Type: Article
Times cited : (117)

References (17)
  • 3
    • 0035068882 scopus 로고    scopus 로고
    • Diffusion- and perfusion-weighted brain magnetic resonance imaging in patients with neurologic complications after cardiac surgery
    • Wityk R.J., Goldsborough M.A., Hillis A., Beauchamp N., Barker P.B., Borowicz L.M., McKhann G.M. Diffusion- and perfusion-weighted brain magnetic resonance imaging in patients with neurologic complications after cardiac surgery. Arch Neurol 2000, 58:571-576.
    • (2000) Arch Neurol , vol.58 , pp. 571-576
    • Wityk, R.J.1    Goldsborough, M.A.2    Hillis, A.3    Beauchamp, N.4    Barker, P.B.5    Borowicz, L.M.6    McKhann, G.M.7
  • 5
    • 0008659150 scopus 로고
    • Predictors of mortality, complications, and length of stay in aortic valve replacement for aortic stenosis
    • I-85-I-90
    • Craver J.M., Weintraub W.S., Jones E.L., Guyton R.A., Hatcher C.R. Predictors of mortality, complications, and length of stay in aortic valve replacement for aortic stenosis. Circulation 1988, 78(Suppl. I):I-85-I-90.
    • (1988) Circulation , vol.78 , Issue.SUPPL. 1
    • Craver, J.M.1    Weintraub, W.S.2    Jones, E.L.3    Guyton, R.A.4    Hatcher, C.R.5
  • 6
    • 1842471338 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging and neurobiochemical markers after aortic valve replacement: implications for future neuroprotective trials?
    • Stolz E., Gerriets T., Kluge A., Klovekorn W.P., Kaps M., Bachmann G. Diffusion-weighted magnetic resonance imaging and neurobiochemical markers after aortic valve replacement: implications for future neuroprotective trials?. Stroke 2004, 35:888-892.
    • (2004) Stroke , vol.35 , pp. 888-892
    • Stolz, E.1    Gerriets, T.2    Kluge, A.3    Klovekorn, W.P.4    Kaps, M.5    Bachmann, G.6
  • 11
    • 77950974254 scopus 로고    scopus 로고
    • 'Ring pledget': a new concept for secure apex closure during transapical aortic valve implantation
    • Astarci P., Glineur D., Kefer J., Renkin J., Vanoverschelde J.L., El Khoury G. "Ring pledget": a new concept for secure apex closure during transapical aortic valve implantation. Innovation 2010, 5(2):136-137.
    • (2010) Innovation , vol.5 , Issue.2 , pp. 136-137
    • Astarci, P.1    Glineur, D.2    Kefer, J.3    Renkin, J.4    Vanoverschelde, J.L.5    El Khoury, G.6
  • 12
    • 44449124745 scopus 로고    scopus 로고
    • Cerebral ischemic lesions on diffusion-weighted imaging are associated with neurocognitive decline after cardiac surgery
    • Barber P.A., Hach S., Tippett L.J., Ross L., Merry A.F., Milsom P. Cerebral ischemic lesions on diffusion-weighted imaging are associated with neurocognitive decline after cardiac surgery. Stroke 2008, 39(5):1427-1433.
    • (2008) Stroke , vol.39 , Issue.5 , pp. 1427-1433
    • Barber, P.A.1    Hach, S.2    Tippett, L.J.3    Ross, L.4    Merry, A.F.5    Milsom, P.6
  • 14
    • 65149095001 scopus 로고    scopus 로고
    • Outcomes and safety of percutaneous aortic valve replacement
    • Zajarias A., Cribier A.G. Outcomes and safety of percutaneous aortic valve replacement. J Am Coll Cardiol 2009, 53(20):1829-1836.
    • (2009) J Am Coll Cardiol , vol.53 , Issue.20 , pp. 1829-1836
    • Zajarias, A.1    Cribier, A.G.2
  • 16
    • 77956332671 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation with 'no touch' of the aortic arch for the treatment of severe aortic stenosis associated with complex aortic atherosclerosis
    • Bagur R., Rodés-Cabau J., Doyle D., De Larochellière R., Villeneuve J., Bertrand O.F., Dumont E. Transcatheter aortic valve implantation with "no touch" of the aortic arch for the treatment of severe aortic stenosis associated with complex aortic atherosclerosis. J Card Surg 2010, 25(5):501-503.
    • (2010) J Card Surg , vol.25 , Issue.5 , pp. 501-503
    • Bagur, R.1    Rodés-Cabau, J.2    Doyle, D.3    De Larochellière, R.4    Villeneuve, J.5    Bertrand, O.F.6    Dumont, E.7
  • 17
    • 0036063915 scopus 로고    scopus 로고
    • Mixing during intravertebral arterial infusions in an in vitro model
    • Lutz R.J., Warren K., Balis F., Patronas N., Dedrick R.L. Mixing during intravertebral arterial infusions in an in vitro model. J Neurooncol 2002, 58(2):95-106.
    • (2002) J Neurooncol , vol.58 , Issue.2 , pp. 95-106
    • Lutz, R.J.1    Warren, K.2    Balis, F.3    Patronas, N.4    Dedrick, R.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.