메뉴 건너뛰기




Volumn 204, Issue , 2014, Pages 57-67

Fabrication of thick film sensitive RuO2-TiO2 and Ag/AgCl/KCl reference electrodes and their application for pH measurements

Author keywords

Impedance spectroscopy; Nernstian response; pH sensor; Reference electrode; Sensing electrode; Thick film

Indexed keywords

ALUMINA; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; FABRICATION; PH; POTENTIOMETERS (ELECTRIC MEASURING INSTRUMENTS); REUSABILITY; RUTHENIUM ALLOYS; SPECTROSCOPIC ANALYSIS; THICK FILMS; TITANIUM DIOXIDE; X RAY PHOTOELECTRON SPECTROSCOPY;

EID: 84906309006     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.07.067     Document Type: Article
Times cited : (85)

References (33)
  • 1
    • 77953145049 scopus 로고    scopus 로고
    • Metal oxides and ion-exchanging surfaces as pH sensors in liquids: State-Of-The-Art and outlook
    • P. Kurzweil Metal oxides and ion-exchanging surfaces as pH sensors in liquids: state-of-the-art and outlook Sensors 9 2009 4955 4985
    • (2009) Sensors , vol.9 , pp. 4955-4985
    • Kurzweil, P.1
  • 2
    • 84856222850 scopus 로고    scopus 로고
    • Solid-state sensors monitoring parameters of water quality for the next generation of wireless sensor networks
    • S. Zhuiykov Solid-state sensors monitoring parameters of water quality for the next generation of wireless sensor networks Sens. Actuators B: Chem. 161 2012 1 20
    • (2012) Sens. Actuators B: Chem. , vol.161 , pp. 1-20
    • Zhuiykov, S.1
  • 3
    • 79951642430 scopus 로고    scopus 로고
    • A varactor-based inductively coupled wireless pH sensor
    • B.E. Horton, S. Schweitzer, A.J. DeRouin, and K.G. Ong A varactor-based inductively coupled wireless pH sensor IEEE Sens. J. 11 2011 1061 1066
    • (2011) IEEE Sens. J. , vol.11 , pp. 1061-1066
    • Horton, B.E.1    Schweitzer, S.2    Derouin, A.J.3    Ong, K.G.4
  • 5
    • 77957720779 scopus 로고    scopus 로고
    • 2 sub-micron oxide sensing electrode for water quality monitoring
    • 2 sub-micron oxide sensing electrode for water quality monitoring Ceram. Int. 36 2010 2407 2413
    • (2010) Ceram. Int. , vol.36 , pp. 2407-2413
    • Zhuiykov, S.1
  • 6
    • 41149086271 scopus 로고    scopus 로고
    • Mixed metal oxide films as pH sensing materials
    • DOI 10.1007/s00542-007-0435-9
    • E. Gill, K. Arshak, A. Arshak, and O. Korostynska Mixed metal oxide films as pH sensing materials Microsyst. Technol. 14 2008 499 507 (Pubitemid 351431087)
    • (2008) Microsystem Technologies , vol.14 , Issue.4-5 , pp. 499-507
    • Gill, E.1    Arshak, K.2    Arshak, A.3    Korostynska, O.4
  • 7
    • 0000550193 scopus 로고
    • Solid-state pH sensors for food applications
    • E. Kress-Rogers Solid-state pH sensors for food applications Trends Food Sci. Technol. 2 1991 320 324
    • (1991) Trends Food Sci. Technol. , vol.2 , pp. 320-324
    • Kress-Rogers, E.1
  • 10
    • 37549003643 scopus 로고    scopus 로고
    • Preparation and characteristics of ruthenium dioxide for pH array sensors with real-time measurement system
    • Y-H. Liao, and J-C. Chou Preparation and characteristics of ruthenium dioxide for pH array sensors with real-time measurement system Sens. Actuators B: Chem. 128 2008 603 612
    • (2008) Sens. Actuators B: Chem. , vol.128 , pp. 603-612
    • Liao, Y.-H.1    Chou, J.-C.2
  • 11
    • 0032027694 scopus 로고    scopus 로고
    • Anodic electrodeposition of iridium oxide films
    • PII S0022072897005706
    • M.A. Petit, and V. Plichon Anodic electrodeposition of iridium oxide films J. Electroanal. Chem. 444 1998 247 252 (Pubitemid 128400490)
    • (1998) Journal of Electroanalytical Chemistry , vol.444 , Issue.2 , pp. 247-252
    • Petit, M.A.1    Plichon, V.2
  • 12
    • 0037021770 scopus 로고    scopus 로고
    • A long-term stable iridium oxide pH electrode
    • DOI 10.1016/S0925-4005(01)00972-8, PII S0925400501009728
    • M. Wang, S. Yao, and M. Madou A long term stable iridium oxide pH electrode Sens. Actuators B: Chem. 81 2002 313 315 (Pubitemid 33149438)
    • (2002) Sensors and Actuators, B: Chemical , vol.81 , Issue.2-3 , pp. 313-315
    • Wang, M.1    Yao, S.2    Madou, M.3
  • 15
    • 84906308849 scopus 로고    scopus 로고
    • Materials for electronics
    • S. Kasap, P. Capper (Eds.) Springer Science + Business Media Inc., New York
    • Part C, Materials for Electronics, in: S. Kasap, P. Capper (Eds.), Handbook of Electronic and Photonic Materials, Springer Science + Business Media Inc., New York, 2006, pp. 717-731.
    • (2006) Handbook of Electronic and Photonic Materials , pp. 717-731
    • Part, C.1
  • 16
    • 0021377139 scopus 로고
    • Electronic semiconducting oxides as pH sensors
    • A. Fog, and R.P. Buck Electronic semiconducting oxides as pH sensors Sens. Actuators B: Chem. 5 1984 137 146
    • (1984) Sens. Actuators B: Chem. , vol.5 , pp. 137-146
    • Fog, A.1    Buck, R.P.2
  • 17
    • 0037732795 scopus 로고    scopus 로고
    • Impedance spectroscopy on pH-sensors with lithium lanthanum titanate sensitive material
    • Cl. Bohnke, and J.-L. Fourquet Impedance spectroscopy on pH-sensors with lithium lanthanum titanate sensitive material Electrochim. Acta 48 2003 1869 1878
    • (2003) Electrochim. Acta , vol.48 , pp. 1869-1878
    • Bohnke, Cl.1    Fourquet, J.-L.2
  • 18
    • 58249142788 scopus 로고    scopus 로고
    • 2 sensing electrodes and their properties in water quality monitoring sensors
    • 2 sensing electrodes and their properties in water quality monitoring sensors Sens. Actuators B: Chem. 136 2009 248 256
    • (2009) Sens. Actuators B: Chem. , vol.136 , pp. 248-256
    • Zhuiykov, S.1
  • 20
    • 7944224886 scopus 로고    scopus 로고
    • Screen-printed reference electrodes for potentiometric measurements
    • DOI 10.1016/j.aca.2004.08.056, PII S000326700401116X
    • L. Tymecki, E. Zwierkowska, and R. Koncki Screen-printed reference electrodes for potentiometric measurements Anal. Chim. Acta 526 2004 3 11 (Pubitemid 39470127)
    • (2004) Analytica Chimica Acta , vol.526 , Issue.1 , pp. 3-11
    • Tymecki, L.1    Zwierkowska, E.2    Koncki, R.3
  • 21
    • 0032166067 scopus 로고    scopus 로고
    • Thick film silver-silver chloride reference electrodes
    • A.W.J. Cranny, and J.K. Atkinson Thick film silver-silver chloride reference electrodes Meas. Sci. Technol. 9 1998 1557 1565
    • (1998) Meas. Sci. Technol. , vol.9 , pp. 1557-1565
    • Cranny, A.W.J.1    Atkinson, J.K.2
  • 22
    • 33748980732 scopus 로고    scopus 로고
    • Fabrication and characterization of planar reference electrode for on-chip electroanalysis
    • DOI 10.1016/j.electacta.2006.05.050, PII S0013468606006189
    • X. Sun, and M. Wang Fabrication and characterization of planar reference electrode for on-chip electroanalysis Electrochim. Acta 52 2006 427 433 (Pubitemid 44441221)
    • (2006) Electrochimica Acta , vol.52 , Issue.2 , pp. 427-433
    • Sun, X.1    Wang, M.2
  • 27
    • 33751386484 scopus 로고
    • XPS and XAES study of titania-silica mixed oxide system
    • A.Yu. Stakheev, E.S. Shpiro, and J. Apijok XPS and XAES study of titania-silica mixed oxide system J. Phys. Chem. 97 1993 5668 5672
    • (1993) J. Phys. Chem. , vol.97 , pp. 5668-5672
    • Stakheev, A.Yu.1    Shpiro, E.S.2    Apijok, J.3
  • 28
    • 76849093980 scopus 로고    scopus 로고
    • PH-dependent surface charging of metal oxides
    • E. Tombacz pH-dependent surface charging of metal oxides Period. Polytech.- Chem. 53 2009 77 86
    • (2009) Period. Polytech.- Chem. , vol.53 , pp. 77-86
    • Tombacz, E.1
  • 29
    • 77956804235 scopus 로고
    • Reactions at metal oxide electrodes
    • R.G. Compton (Eds.) Elsevier, New York
    • E.J.M. O'Sullivan, E.J. Calvo, Reactions at metal oxide electrodes, in: R.G. Compton (Eds.), Electrode Kinetics: Reactions, Elsevier, New York, 1987, pp. 247-251.
    • (1987) Electrode Kinetics: Reactions , pp. 247-251
    • O'Sullivan, E.J.M.1    Calvo, E.J.2
  • 33
    • 76449114377 scopus 로고    scopus 로고
    • 2 for a solid-state pH sensor
    • 2 for a solid-state pH sensor Electrochim. Acta 55 2010 2859 2864
    • (2010) Electrochim. Acta , vol.55 , pp. 2859-2864
    • Xu, B.1    Zhang, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.