메뉴 건너뛰기




Volumn 136, Issue 1, 2009, Pages 248-256

Morphology of Pt-doped nanofabricated RuO2 sensing electrodes and their properties in water quality monitoring sensors

Author keywords

Dissolved oxygen; Nanostructures; pH; Ruthenium oxide; Water quality sensors

Indexed keywords

AUGER ELECTRON SPECTROSCOPY; BIOCHEMICAL OXYGEN DEMAND; CHEMICAL SENSORS; DISSOLUTION; DISSOLVED OXYGEN SENSORS; ELECTROCHEMICAL ELECTRODES; FOURIER TRANSFORM INFRARED SPECTROSCOPY; FOURIER TRANSFORMS; HYDROGEN; INFRARED SPECTROSCOPY; NANOSTRUCTURES; NONMETALS; OXYGEN; PLATINUM; RUTHENIUM; RUTHENIUM ALLOYS; RUTHENIUM COMPOUNDS; SCANNING ELECTRON MICROSCOPY; SENSORS; SPECTROSCOPIC ANALYSIS; SPONTANEOUS EMISSION; THERMOANALYSIS; WATER POLLUTION; WATER QUALITY; X RAY ANALYSIS; X RAY DIFFRACTION ANALYSIS;

EID: 58249142788     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2008.10.030     Document Type: Article
Times cited : (71)

References (25)
  • 1
    • 0033571470 scopus 로고    scopus 로고
    • Trends in monitoring of waste water systems
    • Lynggaard-Jensen A. Trends in monitoring of waste water systems. Talanta 50 (1999) 707-716
    • (1999) Talanta , vol.50 , pp. 707-716
    • Lynggaard-Jensen, A.1
  • 2
    • 0005361337 scopus 로고    scopus 로고
    • Sensors for waste water: many needs but financial and technical limitations
    • Wacheux H. Sensors for waste water: many needs but financial and technical limitations. Monit. Water Qual. 14 (1998) 229-235
    • (1998) Monit. Water Qual. , vol.14 , pp. 229-235
    • Wacheux, H.1
  • 3
    • 37549003643 scopus 로고    scopus 로고
    • Preparation and characteristics of ruthenium dioxide for pH array sensors with real-time measurement system
    • Liao Y.-H., and Chou J.-C. Preparation and characteristics of ruthenium dioxide for pH array sensors with real-time measurement system. Sens. Actuators B 128 (2008) 603-612
    • (2008) Sens. Actuators B , vol.128 , pp. 603-612
    • Liao, Y.-H.1    Chou, J.-C.2
  • 4
    • 33646774712 scopus 로고    scopus 로고
    • Sub-surface probe module equipped with the Karlsruhe micronose KAMINA using a hierarchical LDA for the recognition of volatile soil pollutants
    • Arnold C., Haeringer D., Kiselev I., and Goschnick J. Sub-surface probe module equipped with the Karlsruhe micronose KAMINA using a hierarchical LDA for the recognition of volatile soil pollutants. Sens. Actuators B 116 (2006) 90-94
    • (2006) Sens. Actuators B , vol.116 , pp. 90-94
    • Arnold, C.1    Haeringer, D.2    Kiselev, I.3    Goschnick, J.4
  • 13
    • 44249089229 scopus 로고    scopus 로고
    • 2 electrodes for integrated water quality monitoring sensors
    • 2 electrodes for integrated water quality monitoring sensors. Electrochem. Commun. 10 (2008) 839-843
    • (2008) Electrochem. Commun. , vol.10 , pp. 839-843
    • Zhuiykov, S.1
  • 14
    • 0037120777 scopus 로고    scopus 로고
    • A novel method to determine the diffusion coefficient of hydrogen ion in ruthenium oxide films
    • Yu G.T., and Yen S.K. A novel method to determine the diffusion coefficient of hydrogen ion in ruthenium oxide films. Chem. Phys. Lett. 364 (2002) 517-521
    • (2002) Chem. Phys. Lett. , vol.364 , pp. 517-521
    • Yu, G.T.1    Yen, S.K.2
  • 16
    • 58249144518 scopus 로고    scopus 로고
    • S. Zhuiykov, A composite material for use in a sensing electrode for measuring water quality, Australian provisional patent application 2008902285, May 9, 2008.
    • S. Zhuiykov, A composite material for use in a sensing electrode for measuring water quality, Australian provisional patent application 2008902285, May 9, 2008.
  • 17
    • 7944224886 scopus 로고    scopus 로고
    • Screen-printed reference electrodes for potentiometric measurements
    • Tymecki L., Zwierkowska E., and Koncki R. Screen-printed reference electrodes for potentiometric measurements. Anal. Chem. Acta 526 (2004) 3-11
    • (2004) Anal. Chem. Acta , vol.526 , pp. 3-11
    • Tymecki, L.1    Zwierkowska, E.2    Koncki, R.3
  • 18
    • 33748980732 scopus 로고    scopus 로고
    • Fabrication and characterization of planar reference electrode for on-chip electroanalysis
    • Sun X., and Wang M. Fabrication and characterization of planar reference electrode for on-chip electroanalysis. Electrochem. Acta 52 (2006) 427-433
    • (2006) Electrochem. Acta , vol.52 , pp. 427-433
    • Sun, X.1    Wang, M.2
  • 21
    • 58249140992 scopus 로고    scopus 로고
    • 2 thin-film electrode, Ionics, in press.
    • 2 thin-film electrode, Ionics, in press.
  • 23
    • 0037199904 scopus 로고    scopus 로고
    • Preparation and study on the drift and hysteresis properties of the tin oxide gate ISFET by the sol gel method
    • Chou J.C., and Wang Y.F. Preparation and study on the drift and hysteresis properties of the tin oxide gate ISFET by the sol gel method. Sens. Actuators B 86 (2002) 58-62
    • (2002) Sens. Actuators B , vol.86 , pp. 58-62
    • Chou, J.C.1    Wang, Y.F.2
  • 24
    • 58249137622 scopus 로고    scopus 로고
    • 2 film electrodes and their properties in integrated water quality sensors, J. Mater. Chem., submitted for publication.
    • 2 film electrodes and their properties in integrated water quality sensors, J. Mater. Chem., submitted for publication.
  • 25
    • 58249129201 scopus 로고    scopus 로고
    • S. Zhuiykov, Integrated multilayered "electronic tongue" for in situ water quality monitoring, in: F. Columbus (Ed.), Water Quality: Physical, Chemical and Biological Characteristics, Nova Science Publishing, in press.
    • S. Zhuiykov, Integrated multilayered "electronic tongue" for in situ water quality monitoring, in: F. Columbus (Ed.), Water Quality: Physical, Chemical and Biological Characteristics, Nova Science Publishing, in press.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.