Volumn 11, Issue 4, 2011, Pages 1061-1066

A varactor-based, inductively coupled wireless pH sensor

Author keywords

Antimony antimony oxide; inductive capacitive resonant circuit; passive; pH sensor; silver sliver chloride; varactor; wireless

Indexed keywords

ANTIMONY/ANTIMONY OXIDE; INDUCTIVE-CAPACITIVE RESONANT CIRCUIT; PASSIVE; SILVER/SLIVER CHLORIDE; WIRELESS;

EID: 79951642430     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2010.2062503     Document Type: Article
Times cited : (53)

References (22)
  • 1
    • 4644255319 scopus 로고    scopus 로고
    • Development of a method for the optical in-situ determination of pH value during high-pressure treatment of fluid food
    • DOI 10.1016/j.ifset.2004.05.002, PII S1466856404000505
    • V. M. Stippl, A. Delgado, and T. M. Becker, "Development of a method for the optical in-situ determination of pH value during high-pressure treatment of fluid food," Innovative Food Sci. & Emerging Technologi (Pubitemid 39268781)
    • (2004) Innovative Food Science and Emerging Technologies , vol.5 , Issue.3 , pp. 285-292
    • Stippl, V.M.1    Delgado, A.2    Becker, T.M.3
  • 2
    • 0037376695 scopus 로고    scopus 로고
    • PH sensors with lithium lanthanum titanate sensitive material: Applications in food industry
    • C. L. Bohnke, H. Duroy, and J.-L. Fourquet, "pH sensors with lithium lanthanum titanate sensitive material: Applications in food industry," Sens. Actuators B, vol. 89, no. 3, pp. 240-247, 2003.
    • (2003) Sens. Actuators B , vol.89 , Issue.3 , pp. 240-247
    • Bohnke, C.L.1    Duroy, H.2    Fourquet, J.-L.3
  • 3
    • 68849083492 scopus 로고    scopus 로고
    • Importance of pH on antibrowning activity of Oxalic acid
    • R. Yoruk and M. Marshall, "Importance of pH on antibrowning activity of Oxalic acid," J. Food Biochem., vol. 33, no. 4, pp. 522-534, 2009.
    • (2009) J. Food Biochem , vol.33 , Issue.4 , pp. 522-534
    • Yoruk, R.1    Marshall, M.2
  • 6
    • 0000550193 scopus 로고
    • Solid-state pH sensors for food applications
    • E. Kress-Rogers, "Solid-state pH sensors for food applications," Trends Food Sci. & Technol., vol. 2, pp. 320-324, 1991.
    • (1991) Trends Food Sci. & Technol. , vol.2 , pp. 320-324
    • Kress-Rogers, E.1
  • 7
    • 54049121079 scopus 로고    scopus 로고
    • Gastroesophageal reflux disease
    • P. Kahrilas, "Gastroesophageal reflux disease," New Engl. J. Med., vol. 359, pp. 1700-1707, 2008.
    • (2008) New Engl. J. Med. , vol.359 , pp. 1700-1707
    • Kahrilas, P.1
  • 8
    • 42449105395 scopus 로고    scopus 로고
    • Use and utility of the Bravo pH Capsule
    • J. E. Pandolfino and M. A. Kwiatek, "Use and utility of the Bravo pH Capsule," J. Clin. Gastroenterol., vol. 42, no. 5, pp. 571-578, 2008.
    • (2008) J. Clin. Gastroenterol. , vol.42 , Issue.5 , pp. 571-578
    • Pandolfino, J.E.1    Kwiatek, M.A.2
  • 9
    • 33745470685 scopus 로고    scopus 로고
    • PH Monitoring: A review
    • DOI 10.1007/s10008-006-0120-4
    • W. Vonau and U. Guth, "pH monitoring: A review," J. Solid-State Electrochem., vol. 10, pp. 746-752, 2006. (Pubitemid 43954123)
    • (2006) Journal of Solid State Electrochemistry , vol.10 , Issue.9 , pp. 746-752
    • Vonau, W.1    Guth, U.2
  • 10
    • 0034310715 scopus 로고    scopus 로고
    • A remote query magnetoelastic pH sensor
    • Q. Cai and C. A. Grimes, "A remote query magnetoelastic pH sensor," Sens. Actuators, B, vol. 71, no. 1-2, pp. 112-117, 2000.
    • (2000) Sens. Actuators, B , vol.71 , Issue.1-2 , pp. 112-117
    • Cai, Q.1    Grimes, C.A.2
  • 11
    • 0035888347 scopus 로고    scopus 로고
    • A salt-independent pH sensor
    • DOI 10.1016/S0925-4005(01)00860-7, PII S0925400501008607
    • Q. Y. Cai and C. A. Grimes, "A salt-independent pH sensor," Sens. Actuators, B, vol. 79, no. 2-3, pp. 144-149, 2001. (Pubitemid 32866880)
    • (2001) Sensors and Actuators, B: Chemical , vol.79 , Issue.2-3 , pp. 144-149
    • Cai, Q.Y.1    Grimes, C.A.2
  • 12
    • 0142231077 scopus 로고    scopus 로고
    • A mass-sensitive pH sensor based on a stimuli-responsive polymer
    • DOI 10.1016/j.aca.2003.08.051
    • C. Ruan, K. Zeng, and C. A. Grimes, "A mass-sensitive pH sensor based on a stimuli-responsive polymer," Analytica Chimica Acta, vol. 497, no. 1-2, pp. 123-131, 2003. (Pubitemid 37315717)
    • (2003) Analytica Chimica Acta , vol.497 , Issue.1-2 , pp. 123-131
    • Ruan, C.1    Zeng, K.2    Grimes, C.A.3
  • 13
    • 0242489280 scopus 로고    scopus 로고
    • A wireless pH sensor based on the use of salt-independent micro-scale polymer spheres
    • C. Ruan, K. G. Ong, C. Mungle, M. Paulose, N. J. Nickl, and C. A. Grimes, "A wireless pH sensor based on the use of salt-independent micro-scale polymer spheres," Sens. Actuators, B, vol. 96, no. 1-2, pp. 61-69, 2003.
    • (2003) Sens. Actuators, B , vol.96 , Issue.1-2 , pp. 61-69
    • Ruan, C.1    Ong, K.G.2    Mungle, C.3    Paulose, M.4    Nickl, N.J.5    Grimes, C.A.6
  • 14
    • 67349168792 scopus 로고    scopus 로고
    • Hydrogelbased microsensors for wireless chemical monitoring
    • M. Lei, A. Baldi, E. Nuxoll, R. A. Siegel, and B. Ziaie, "Hydrogelbased microsensors for wireless chemical monitoring," Biomed, Microdevices, vol. 11, pp. 529-538, 2009.
    • (2009) Biomed, Microdevices , vol.11 , pp. 529-538
    • Lei, M.1    Baldi, A.2    Nuxoll, E.3    Siegel, R.A.4    Ziaie, B.5
  • 16
    • 18444398689 scopus 로고    scopus 로고
    • Remote query resonant-circuit sensors for monitoring of bacteria growth: Application to food quality control
    • K. G. Ong, J. S. Bitler, C. A. Grimes, L. G. Puckett, and L. G. Bachas, "Remote query resonant-circuit sensors for monitoring of bacteria growth: Application to food quality control," Sensors, vol. 2, pp. 219-232, 2002. (Pubitemid 40643499)
    • (2002) Sensors , vol.2 , Issue.6 , pp. 219-232
    • Ong, K.G.1    Samuel Bitler, J.2    Grimes, C.A.3    Puckett, L.G.4    Bachas, L.G.5
  • 17
    • 34948903316 scopus 로고    scopus 로고
    • A wireless, passive sensor for quantifying packaged food quality
    • E. L. Tan, W. N. Ng, R. Shao, B. Pereles, and K. G. Ong, "A wireless, passive sensor for quantifying packaged food quality," Sensors, vol. 7, pp. 1747-1756, 2007.
    • (2007) Sensors , vol.7 , pp. 1747-1756
    • Tan, E.L.1    Ng, W.N.2    Shao, R.3    Pereles, B.4    Ong, K.G.5
  • 18
    • 0035948958 scopus 로고    scopus 로고
    • Design and application of a wireless, passive, resonant-circuit environmental monitoring sensor
    • DOI 10.1016/S0924-4247(01)00624-0, PII S0924424701006240
    • K. G. Ong, C. A. Grimes, C. L. Robbins, and R. S. Singh, "Design and application of wireless, passive, resonant-circuit environmental monitoring sensor," Sens. Actuators, A, vol. 93, pp. 33-43, 2001. (Pubitemid 32897571)
    • (2001) Sensors and Actuators, A: Physical , vol.93 , Issue.1 , pp. 33-43
    • Ong, K.G.1    Grimes, C.A.2    Robbins, C.L.3    Singh, R.S.4
  • 20
    • 33947601381 scopus 로고    scopus 로고
    • An electrochemical approach to monitor pH change in agar media during plant tissue culture
    • DOI 10.1016/j.bios.2006.11.009, PII S0956566306005501
    • M. Wang and Y. Ha, "An electrochemical approach to monitor pH change in agar media during plant tissue culture," Biosens. Bioelectron., vol. 22, pp. 2718-2723, 2007. (Pubitemid 46484271)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.11 , pp. 2718-2723
    • Wang, M.1    Ha, Y.2
  • 21
    • 74549138585 scopus 로고    scopus 로고
    • Utility of remote wireless pressure sensing for endovascular leak detection after endovascular thoracic aneurysm repair
    • C. J. Parsa, M. A. Daneshmand, B. Lima, K. Balsara, R. L. McCann, and G. C. Hughes, "Utility of remote wireless pressure sensing for endovascular leak detection after endovascular thoracic aneurysm repair," Ann. Thorac Surg., vol. 89, no. 2, pp. 446-452, 2010.
    • (2010) Ann. Thorac Surg. , vol.89 , Issue.2 , pp. 446-452
    • Parsa, C.J.1    Daneshmand, M.A.2    Lima, B.3    Balsara, K.4    McCann, R.L.5    Hughes, G.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.