메뉴 건너뛰기




Volumn 16, Issue 6, 2014, Pages 1075-1087

Portable bead-based fluorescence detection system for multiplex nucleic acid testing: A case study with Bacillus anthracis

Author keywords

Biothreat detection; DNA hybridization; Integration; Microfluidic chip; Point of care testing

Indexed keywords

ASSAYS; DNA; FLUORESCENCE; INTEGRATION; MICROFLUIDICS; MULTIPLEXING; PROJECTILES;

EID: 84904762532     PISSN: 16134982     EISSN: 16134990     Source Type: Journal    
DOI: 10.1007/s10404-013-1273-y     Document Type: Conference Paper
Times cited : (9)

References (43)
  • 1
    • 0141705552 scopus 로고    scopus 로고
    • DNA hybridization and discrimination of single-nucleotide mismatches using chip-based microbead arrays
    • 10.1021/ac034106z
    • Ali MF, Kirby R, Goodey AP, Rodriguez MD, Ellington AD, Neikirk DP, McDevitt JT (2003) DNA hybridization and discrimination of single-nucleotide mismatches using chip-based microbead arrays. Anal Chem 75:4732-4739
    • (2003) Anal Chem , vol.75 , pp. 4732-4739
    • Ali, M.F.1    Kirby, R.2    Goodey, A.P.3    Rodriguez, M.D.4    Ellington, A.D.5    Neikirk, D.P.6    McDevitt, J.T.7
  • 3
    • 84904767925 scopus 로고    scopus 로고
    • Method and apparatus for detecting fluorescence emitted by particle-bound fluorophores confined by particle traps
    • 0226962
    • Boudreau D, Gravel J-F, Voisin B, Le Drogoff B, Veres T (2011) Method and apparatus for detecting fluorescence emitted by particle-bound fluorophores confined by particle traps. US 2011(0226962):A1
    • (2011) US , vol.2011
    • Boudreau, D.1    Gravel, J.-F.2    Voisin, B.3    Le Drogoff, B.4    Veres, T.5
  • 4
    • 0024467357 scopus 로고
    • Nucleotide sequence and analysis of the lethal factor gene (lef) from Bacillus anthracis
    • 10.1016/0378-1119(89)90335-1
    • Bragg TS, Robertson DL (1989) Nucleotide sequence and analysis of the lethal factor gene (lef) from Bacillus anthracis. Gene 81:45-54
    • (1989) Gene , vol.81 , pp. 45-54
    • Bragg, T.S.1    Robertson, D.L.2
  • 6
    • 79952939569 scopus 로고    scopus 로고
    • Label-free biosensing based on multilayer fluorescent nanocomposites and a cationic polymeric transducer
    • 10.1021/nn102776m
    • Brouard D, Viger ML, Bracamonte AG, Boudreau D (2011) Label-free biosensing based on multilayer fluorescent nanocomposites and a cationic polymeric transducer. ACS Nano 5:1888-1896
    • (2011) ACS Nano , vol.5 , pp. 1888-1896
    • Brouard, D.1    Viger, M.L.2    Bracamonte, A.G.3    Boudreau, D.4
  • 7
    • 33748559840 scopus 로고    scopus 로고
    • The forgotten variables of DNA array hybridization
    • 10.1016/j.tibtech.2006.07.006
    • Carletti E, Guerra E, Alberti S (2006) The forgotten variables of DNA array hybridization. Trends Biotechnol 24:443-448
    • (2006) Trends Biotechnol , vol.24 , pp. 443-448
    • Carletti, E.1    Guerra, E.2    Alberti, S.3
  • 8
    • 21744441490 scopus 로고    scopus 로고
    • Spectral filtering of light-emitting diodes for fluorescence detection
    • 10.1016/j.aca.2005.05.005
    • de Jong EP, Lucy CA (2005) Spectral filtering of light-emitting diodes for fluorescence detection. Anal Chim Acta 546:37-45
    • (2005) Anal Chim Acta , vol.546 , pp. 37-45
    • De Jong, E.P.1    Lucy, C.A.2
  • 9
    • 33745685449 scopus 로고    scopus 로고
    • Low-picomolar limits of detection using high-power light-emitting diodes for fluorescence
    • 10.1039/b602193j
    • de Jong EP, Lucy CA (2006) Low-picomolar limits of detection using high-power light-emitting diodes for fluorescence. Analyst 131:664-669
    • (2006) Analyst , vol.131 , pp. 664-669
    • De Jong, E.P.1    Lucy, C.A.2
  • 10
    • 33745728444 scopus 로고    scopus 로고
    • PCR-free DNA detection using a magnetic bead-supported polymeric transducer and microelectromagnetic traps
    • 10.1021/ac060486n
    • Dubus S, Gravel J-F, Le Drogoff B, Nobert P, Veres T, Boudreau D (2006) PCR-free DNA detection using a magnetic bead-supported polymeric transducer and microelectromagnetic traps. Anal Chem 78:4457-4464
    • (2006) Anal Chem , vol.78 , pp. 4457-4464
    • Dubus, S.1    Gravel, J.-F.2    Le Drogoff, B.3    Nobert, P.4    Veres, T.5    Boudreau, D.6
  • 13
    • 79955454470 scopus 로고    scopus 로고
    • Air stream-mediated vortex agitation of microlitre entities on a fluidic chip
    • 10.1039/c0lc00723d
    • Geissler M, Voisin B, Veres T (2011) Air stream-mediated vortex agitation of microlitre entities on a fluidic chip. Lab Chip 11:1717-1720
    • (2011) Lab Chip , vol.11 , pp. 1717-1720
    • Geissler, M.1    Voisin, B.2    Veres, T.3
  • 14
  • 16
    • 0037012674 scopus 로고    scopus 로고
    • Colorimetric and fluorometric detection of nucleic acids using cationic polythiophene derivatives
    • 10.1002/1521-3773(20020503)41:9<1548: AID-ANIE1548>3.0.CO;2-I
    • Ho H-A, Boissinot M, Bergeron MG, Corbeil G, Doré K, Boudreau D, Leclerc M (2002) Colorimetric and fluorometric detection of nucleic acids using cationic polythiophene derivatives. Angew Chem Int Ed 41:1548-1551
    • (2002) Angew Chem Int Ed , vol.41 , pp. 1548-1551
    • Ho, H.-A.1    Boissinot, M.2    Bergeron, M.G.3    Corbeil, G.4    Doré, K.5    Boudreau, D.6    Leclerc, M.7
  • 17
    • 0037677909 scopus 로고    scopus 로고
    • Microfluidic diffusion diluter: Bulging of PDMS microchannels under pressure-driven flow
    • 10.1088/0960-1317/13/3/309
    • Holden MA, Kumar S, Beskok A, Cremer PS (2003) Microfluidic diffusion diluter: bulging of PDMS microchannels under pressure-driven flow. J Micromech Microeng 13:412-418
    • (2003) J Micromech Microeng , vol.13 , pp. 412-418
    • Holden, M.A.1    Kumar, S.2    Beskok, A.3    Cremer, P.S.4
  • 20
    • 0034540398 scopus 로고    scopus 로고
    • MRNA isolation in a microfluidic device for eventual integration of cDNA library construction
    • 10.1039/b005999o
    • Jiang GF, Harrison DJ (2000) mRNA isolation in a microfluidic device for eventual integration of cDNA library construction. Analyst 125:2176-2179
    • (2000) Analyst , vol.125 , pp. 2176-2179
    • Jiang, G.F.1    Harrison, D.J.2
  • 21
    • 33846159132 scopus 로고    scopus 로고
    • Hybridization of DNA to bead-immobilized probes confined within a microfluidic channel
    • 10.1021/la0616956
    • Kim J, Heo J, Crooks RM (2006) Hybridization of DNA to bead-immobilized probes confined within a microfluidic channel. Langmuir 22:10130-10134
    • (2006) Langmuir , vol.22 , pp. 10130-10134
    • Kim, J.1    Heo, J.2    Crooks, R.M.3
  • 22
    • 27144496729 scopus 로고    scopus 로고
    • Current and developing technologies for monitoring agents of bioterrorism and biowarfare
    • 10.1128/CMR.18.4.583-607.2005
    • Lim DV, Simpson JM, Kearns EA, Kramer MF (2005) Current and developing technologies for monitoring agents of bioterrorism and biowarfare. Clin Microbiol Rev 18:583-607
    • (2005) Clin Microbiol Rev , vol.18 , pp. 583-607
    • Lim, D.V.1    Simpson, J.M.2    Kearns, E.A.3    Kramer, M.F.4
  • 25
    • 0024595710 scopus 로고
    • Molecular characterization and molecular analysis of the cap region, which is essential for encapsulation of Bacillus anthracis
    • Makino S-I, Uchida I, Terakado N, Sasakawa C, Yoshikawa M (1989) Molecular characterization and molecular analysis of the cap region, which is essential for encapsulation of Bacillus anthracis. J Bacteriol 171:722-730
    • (1989) J Bacteriol , vol.171 , pp. 722-730
    • Makino, S.-I.1    Uchida, I.2    Terakado, N.3    Sasakawa, C.4    Yoshikawa, M.5
  • 26
    • 77952527887 scopus 로고    scopus 로고
    • Microfluidic lab-on-a-chip platforms: Requirements, characteristics and applications
    • 10.1039/b820557b
    • Mark D, Haeberle S, Roth G, von Stetten F, Zengerle R (2010) Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. Chem Soc Rev 39:1153-1182
    • (2010) Chem Soc Rev , vol.39 , pp. 1153-1182
    • Mark, D.1    Haeberle, S.2    Roth, G.3    Von Stetten, F.4    Zengerle, R.5
  • 29
    • 33845742675 scopus 로고    scopus 로고
    • An integrated fluorescence detection system for lab-on-a-chip applications
    • 10.1039/b611745g
    • Novak L, Neuzil P, Pipper J, Zhang Y, Lee S (2007) An integrated fluorescence detection system for lab-on-a-chip applications. Lab Chip 7:27-29
    • (2007) Lab Chip , vol.7 , pp. 27-29
    • Novak, L.1    Neuzil, P.2    Pipper, J.3    Zhang, Y.4    Lee, S.5
  • 30
    • 34548318887 scopus 로고    scopus 로고
    • Specific magnetic bead-based capture of genomic DNA from clinical samples: Application to the detection of group B streptococci in vaginal/anal swabs
    • 10.1373/clinchem.2007.091389
    • Parham NJ, Picard FJ, Peytavi R, Gagnon M, Seyrig G, Gagné P-A, Boissinot M, Bergeron MG (2007) Specific magnetic bead-based capture of genomic DNA from clinical samples: application to the detection of group B streptococci in vaginal/anal swabs. Clin Chem 53:1570-1576
    • (2007) Clin Chem , vol.53 , pp. 1570-1576
    • Parham, N.J.1    Picard, F.J.2    Peytavi, R.3    Gagnon, M.4    Seyrig, G.5    Gagné, P.-A.6    Boissinot, M.7    Bergeron, M.G.8
  • 33
    • 0024234807 scopus 로고
    • Nucleotide sequence of the Bacillus anthracis edema factor gene (cya): A calmodulin-dependent adenylate cyclase
    • 10.1016/0378-1119(88)90501-X
    • Robertson DL, Tippetts MT, Leppla SH (1988) Nucleotide sequence of the Bacillus anthracis edema factor gene (cya): a calmodulin-dependent adenylate cyclase. Gene 73:363-371
    • (1988) Gene , vol.73 , pp. 363-371
    • Robertson, D.L.1    Tippetts, M.T.2    Leppla, S.H.3
  • 34
    • 80755163305 scopus 로고    scopus 로고
    • Prototyping of microfluidic systems using a commercial thermoplastic elastomer
    • 10.1007/s10404-011-0789-2
    • Roy E, Geissler M, Galas J-C, Veres T (2011) Prototyping of microfluidic systems using a commercial thermoplastic elastomer. Microfluid Nanofluid 11:235-244
    • (2011) Microfluid Nanofluid , vol.11 , pp. 235-244
    • Roy, E.1    Geissler, M.2    Galas, J.-C.3    Veres, T.4
  • 35
    • 77949839841 scopus 로고    scopus 로고
    • High-throughput fluorescence detection using an integrated zone-plate array
    • 10.1039/b923554j
    • Schonbrun E, Abate AR, Steinvurzel PE, Weiz DA, Crozier KB (2010) High-throughput fluorescence detection using an integrated zone-plate array. Lab Chip 10:852-856
    • (2010) Lab Chip , vol.10 , pp. 852-856
    • Schonbrun, E.1    Abate, A.R.2    Steinvurzel, P.E.3    Weiz, D.A.4    Crozier, K.B.5
  • 36
    • 0037073189 scopus 로고    scopus 로고
    • Efficient mixing and reactions within microfluidic channels using microbead-supported catalysts
    • 10.1021/ja020932y
    • Seong GH, Crooks RM (2002) Efficient mixing and reactions within microfluidic channels using microbead-supported catalysts. J Am Chem Soc 124:13360-13361
    • (2002) J Am Chem Soc , vol.124 , pp. 13360-13361
    • Seong, G.H.1    Crooks, R.M.2
  • 37
    • 33847370217 scopus 로고    scopus 로고
    • Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip
    • 10.1016/j.bios.2006.11.011
    • Shin K-S, Lee SW, Han K-C, Kim SK, Yang EK, Park JH, Ju B-K, Kang JY, Kim TS (2007) Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip. Biosens Bioelectron 22:2261-2267
    • (2007) Biosens Bioelectron , vol.22 , pp. 2261-2267
    • Shin, K.-S.1    Lee, S.W.2    Han, K.-C.3    Kim, S.K.4    Yang, E.K.5    Park, J.H.6    Ju, B.-K.7    Kang, J.Y.8    Kim, T.S.9
  • 38
    • 0021967604 scopus 로고
    • Association of the encapsulation of Bacillus anthracis with a 60 Megadalton plasmid
    • Uchida I, Sekizaki T, Hashimoto K, Terakado N (1985) Association of the encapsulation of Bacillus anthracis with a 60 Megadalton plasmid. J Gen Microbiol 131:363-367
    • (1985) J Gen Microbiol , vol.131 , pp. 363-367
    • Uchida, I.1    Sekizaki, T.2    Hashimoto, K.3    Terakado, N.4
  • 39
    • 0022636624 scopus 로고
    • Virulence and immunogenicity in experimental animals of Bacillus anthracis strains harbouring or lacking 110 MDa and 60 MDa plasmids
    • Uchida I, Hashimoto K, Terakado N (1986) Virulence and immunogenicity in experimental animals of Bacillus anthracis strains harbouring or lacking 110 MDa and 60 MDa plasmids. J Gen Microbiol 132:557-559
    • (1986) J Gen Microbiol , vol.132 , pp. 557-559
    • Uchida, I.1    Hashimoto, K.2    Terakado, N.3
  • 40
    • 43449109467 scopus 로고    scopus 로고
    • Telomerase catalyzed fluorescent probes for sensitive protein profiling based on one-dimensional microfluidic beads array
    • 10.1016/j.bios.2008.02.018
    • Wen J, Yang X, Wang K, Tan W, Zuo X, Zhang H (2008) Telomerase catalyzed fluorescent probes for sensitive protein profiling based on one-dimensional microfluidic beads array. Biosens Bioelectron 23:1788-1792
    • (2008) Biosens Bioelectron , vol.23 , pp. 1788-1792
    • Wen, J.1    Yang, X.2    Wang, K.3    Tan, W.4    Zuo, X.5    Zhang, H.6
  • 41
    • 23644448617 scopus 로고    scopus 로고
    • Development of a microfluidic biosensor module for pathogen detection
    • 10.1039/b503856a
    • Zaytseva NV, Goral VN, Montagna RA, Baeumner AJ (2005) Development of a microfluidic biosensor module for pathogen detection. Lab Chip 5:805-811
    • (2005) Lab Chip , vol.5 , pp. 805-811
    • Zaytseva, N.V.1    Goral, V.N.2    Montagna, R.A.3    Baeumner, A.J.4
  • 42
    • 37549068105 scopus 로고    scopus 로고
    • Detection of single-base mutations using 1-D microfluidic beads array
    • 10.1002/elps.200700048
    • Zhang H, Yang X, Wang K, Tan W, Zhou L, Zuo X, Wen J, Chen Y (2007) Detection of single-base mutations using 1-D microfluidic beads array. Electrophoresis 28:4668-4678
    • (2007) Electrophoresis , vol.28 , pp. 4668-4678
    • Zhang, H.1    Yang, X.2    Wang, K.3    Tan, W.4    Zhou, L.5    Zuo, X.6    Wen, J.7    Chen, Y.8
  • 43
    • 38749147297 scopus 로고    scopus 로고
    • On-chip oligonucleotide ligation assay using one-dimensional microfluidic beads array for the detection of low-abundant DNA point mutations
    • 10.1016/j.bios.2007.09.012
    • Zhang H, Yang X, Wang K, Tan W, Li H, Zuo X, Wen J (2008) On-chip oligonucleotide ligation assay using one-dimensional microfluidic beads array for the detection of low-abundant DNA point mutations. Biosens Bioelectron 23:945-951
    • (2008) Biosens Bioelectron , vol.23 , pp. 945-951
    • Zhang, H.1    Yang, X.2    Wang, K.3    Tan, W.4    Li, H.5    Zuo, X.6    Wen, J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.