메뉴 건너뛰기




Volumn 29, Issue 2, 2014, Pages 234-242

Enhancement of CRF-PEEK osseointegration by plasma-sprayed hydroxyapatite: A rabbit model

Author keywords

coating; hydroxyapatite; in vivo; osseointegration; Polyether ether ketone

Indexed keywords

BIOCOMPATIBILITY; BONE; COATINGS; PLASMA SPRAYING; POLYETHER ETHER KETONES; TITANIUM ALLOYS;

EID: 84904321474     PISSN: 08853282     EISSN: 15308022     Source Type: Journal    
DOI: 10.1177/0885328214521669     Document Type: Article
Times cited : (47)

References (28)
  • 2
    • 0028504954 scopus 로고
    • Fundamental load transfer patterns for press-fit, surface-treated intramedullary fixation stems
    • DOI 10.1016/0021-9290(94)90055-8
    • Keaveny TM, Bartel DL. Fundamental load transfer patterns for press-fit, surface-treated intramedullary fixation stems. J Biomech. 1994 ; 27: 1147-1157 (Pubitemid 24211195)
    • (1994) Journal of Biomechanics , vol.27 , Issue.9 , pp. 1147-1157
    • Keaveny, T.M.1
  • 3
    • 0032020759 scopus 로고    scopus 로고
    • [Possibilities of follow-up imaging after implantation of a carbon fiber-reinforced hip prosthesis]
    • Kruger T, Alter C, Reichel H, et al. [Possibilities of follow-up imaging after implantation of a carbon fiber-reinforced hip prosthesis]. Aktuelle Radiol. 1998 ; 8: 81-86
    • (1998) Aktuelle Radiol , vol.8 , pp. 81-86
    • Kruger, T.1    Alter, C.2    Reichel, H.3
  • 5
    • 47649088851 scopus 로고    scopus 로고
    • Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head
    • Scholes SC, Inman IA, Unsworth A, et al. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head. Proc Inst Mech Eng H. 2008 ; 222: 273-283
    • (2008) Proc Inst Mech Eng H , vol.222 , pp. 273-283
    • Scholes, S.C.1    Inman, I.A.2    Unsworth, A.3
  • 6
    • 58549086944 scopus 로고    scopus 로고
    • Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials
    • Scholes SC, Unsworth A. Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials. J Mater Sci Mater Med. 2009 ; 20: 163-170
    • (2009) J Mater Sci Mater Med , vol.20 , pp. 163-170
    • Scholes, S.C.1    Unsworth, A.2
  • 7
    • 0141645493 scopus 로고    scopus 로고
    • Use of a novel carbon fibre composite material for the femoral stem component of a THR system: In vitro biological assessment
    • DOI 10.1016/S0142-9612(03)00403-4
    • Scotchford CA, Garle MJ, Batchelor J, et al. Use of a novel carbon fibre composite material for the femoral stem component of a THR system: in vitro biological assessment. Biomaterials. 2003 ; 24: 4871-4879 (Pubitemid 37188667)
    • (2003) Biomaterials , vol.24 , Issue.26 , pp. 4871-4879
    • Scotchford, C.A.1    Garle, M.J.2    Batchelor, J.3    Bradley, J.4    Grant, D.M.5
  • 8
    • 0029084917 scopus 로고
    • In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblasts
    • Morrison C, Macnair R, MacDonald C, et al. In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblasts. Biomaterials. 1995 ; 16: 987-992
    • (1995) Biomaterials , vol.16 , pp. 987-992
    • Morrison, C.1    Macnair, R.2    Macdonald, C.3
  • 10
    • 84859436768 scopus 로고    scopus 로고
    • Osteoblasts exhibit a more differentiated phenotype and increased bone morphogenetic protein production on titanium alloy substrates than on poly-ether-ether-ketone
    • Olivares-Navarrete R, Gittens RA, Schneider JM, et al. Osteoblasts exhibit a more differentiated phenotype and increased bone morphogenetic protein production on titanium alloy substrates than on poly-ether-ether-ketone. Spine J. 2012 ; 12: 265-272
    • (2012) Spine J , vol.12 , pp. 265-272
    • Olivares-Navarrete, R.1    Gittens, R.A.2    Schneider, J.M.3
  • 12
    • 71749113601 scopus 로고    scopus 로고
    • Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases
    • Beldame J, Carreras F, Oger P, et al. Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases. Orthop Traumatol Surg Res. 2009 ; 95: 478-490
    • (2009) Orthop Traumatol Surg Res , vol.95 , pp. 478-490
    • Beldame, J.1    Carreras, F.2    Oger, P.3
  • 13
    • 71349087525 scopus 로고    scopus 로고
    • Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: Analysis of 111 cases with a minimum follow-up of 10 years
    • Bidar R, Kouyoumdjian P, Munini E, et al. Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years. Orthop Traumatol Surg Res. 2009 ; 95: 579-587
    • (2009) Orthop Traumatol Surg Res , vol.95 , pp. 579-587
    • Bidar, R.1    Kouyoumdjian, P.2    Munini, E.3
  • 14
    • 84861798034 scopus 로고    scopus 로고
    • Bone response to free-form fabricated hydroxyapatite and zirconia scaffolds: A transmission electron microscopy study in the human maxilla
    • Grandfield K, Palmquist A, Ericson F, et al. Bone response to free-form fabricated hydroxyapatite and zirconia scaffolds: a transmission electron microscopy study in the human maxilla. Clin Implant Dent Relat Res. 2012 ; 14: 461-469
    • (2012) Clin Implant Dent Relat Res , vol.14 , pp. 461-469
    • Grandfield, K.1    Palmquist, A.2    Ericson, F.3
  • 15
    • 80051620153 scopus 로고    scopus 로고
    • Free form fabricated features on CoCr implants with and without hydroxyapatite coating in vivo: A comparative study of bone contact and bone growth induction
    • Grandfield K, Palmquist A, Goncalves S, et al. Free form fabricated features on CoCr implants with and without hydroxyapatite coating in vivo: a comparative study of bone contact and bone growth induction. J Mater Sci Mater Med. 2011 ; 22: 899-906
    • (2011) J Mater Sci Mater Med , vol.22 , pp. 899-906
    • Grandfield, K.1    Palmquist, A.2    Goncalves, S.3
  • 16
    • 34548021405 scopus 로고    scopus 로고
    • PEEK biomaterials in trauma, orthopedic, and spinal implants
    • DOI 10.1016/j.biomaterials.2007.07.013, PII S0142961207005467
    • Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials. 2007 ; 28: 4845-4869 (Pubitemid 47285335)
    • (2007) Biomaterials , vol.28 , Issue.32 , pp. 4845-4869
    • Kurtz, S.M.1    Devine, J.N.2
  • 17
    • 0027551874 scopus 로고
    • Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
    • DOI 10.1016/0021-9290(93)90042-D
    • Rho JY, Ashman RB, Turner CH. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J Biomech. 1993 ; 26: 111-119 (Pubitemid 23067441)
    • (1993) Journal of Biomechanics , vol.26 , Issue.2 , pp. 111-119
    • Rho, J.Y.1    Ashman, R.B.2    Turner, H.3
  • 19
    • 0023741286 scopus 로고
    • Composite technology for total hip arthroplasty
    • Skinner HB. Composite technology for total hip arthroplasty. Clin Orthop Relat Res. 1988 ; 235: 224-236
    • (1988) Clin Orthop Relat Res , vol.235 , pp. 224-236
    • Skinner, H.B.1
  • 20
    • 84865524457 scopus 로고    scopus 로고
    • Interfacial shear strength of bioactive-coated carbon fiber reinforced polyetheretherketone after in vivo implantation
    • Nakahara I, Takao M, Goto T, et al. Interfacial shear strength of bioactive-coated carbon fiber reinforced polyetheretherketone after in vivo implantation. J Orthop Res. 2012 ; 30: 1618-1625
    • (2012) J Orthop Res , vol.30 , pp. 1618-1625
    • Nakahara, I.1    Takao, M.2    Goto, T.3
  • 21
    • 0031737699 scopus 로고    scopus 로고
    • Hydroxyapatite-coated implants: A case against their use
    • Albrektsson T. Hydroxyapatite-coated implants: a case against their use. J Oral Maxillofac Surg. 1998 ; 56: 1312-1326 (Pubitemid 28515921)
    • (1998) Journal of Oral and Maxillofacial Surgery , vol.56 , Issue.11 SUPPL. 5 , pp. 1312-1326
    • Albrektsson, T.1
  • 23
    • 84872680339 scopus 로고    scopus 로고
    • Nano-hydroxyapatite-coated PEEK implants: A pilot study in rabbit bone
    • Barkarmo S, Wennerberg A, Hoffman M, et al. Nano-hydroxyapatite-coated PEEK implants: a pilot study in rabbit bone. J Biomed Mater Res A. 2013 ; 101: 465-471
    • (2013) J Biomed Mater Res A , vol.101 , pp. 465-471
    • Barkarmo, S.1    Wennerberg, A.2    Hoffman, M.3
  • 24
    • 1642266364 scopus 로고    scopus 로고
    • Plasma-sprayed hydroxyapatite+titania composite bond coat for hydroxyapatite coating on titanium substrate
    • Lu YP, Li MS, Li ST, et al. Plasma-sprayed hydroxyapatite+titania composite bond coat for hydroxyapatite coating on titanium substrate. Biomaterials. 2004 ; 25: 4393-4403
    • (2004) Biomaterials , vol.25 , pp. 4393-4403
    • Lu, Y.P.1    Li, M.S.2    Li, S.T.3
  • 25
    • 68549092607 scopus 로고    scopus 로고
    • Effects of titanium surface topography on bone integration: A systematic review
    • Wennerberg A, Albrektsson T. Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res. 2009 ; 20: 172-184
    • (2009) Clin Oral Implants Res , vol.20 , pp. 172-184
    • Wennerberg, A.1    Albrektsson, T.2
  • 26
    • 77249117286 scopus 로고    scopus 로고
    • The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties
    • Han CM, Lee EJ, Kim HE, et al. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties. Biomaterials. 2010 ; 31: 3465-3470
    • (2010) Biomaterials , vol.31 , pp. 3465-3470
    • Han, C.M.1    Lee, E.J.2    Kim, H.E.3
  • 27
    • 0036181415 scopus 로고    scopus 로고
    • Early failure of a press-fit carbon fiber hip prosthesis with a smooth surface
    • DOI 10.1054/arth.2002.30285
    • Adam F, Hammer DS, Pfautsch S, et al. Early failure of a press-fit carbon fiber hip prosthesis with a smooth surface. J Arthroplasty. 2002 ; 17: 217-223 (Pubitemid 34160576)
    • (2002) Journal of Arthroplasty , vol.17 , Issue.2 , pp. 217-223
    • Adam, F.1    Hammer, D.S.2    Pfautsch, S.3    Westermann, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.