-
1
-
-
32244435001
-
Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis
-
DOI 10.1097/01.brs.0000197865.20803.d4
-
Kim YJ, Lenke LG, Kim J, et al. Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis. Spine (Phila Pa 1976). 2006;31: 291-298. (Pubitemid 43214769)
-
(2006)
Spine
, vol.31
, Issue.3
, pp. 291-298
-
-
Kim, Y.J.1
Lenke, L.G.2
Kim, J.3
Bridwell, K.H.4
Cho, S.K.5
Cheh, G.6
Sides, B.7
-
2
-
-
0035884966
-
Thoracic pedicle screw fixation in spinal deformities: Are they really safe
-
Suk SI, Kim WJ, Lee SM, et al. Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine (Phila Pa 1976). 2001; 26:2049-2057.
-
(2001)
Spine (Phila Pa 1976)
, vol.26
, pp. 2049-2057
-
-
Suk, S.I.1
Kim, W.J.2
Lee, S.M.3
-
3
-
-
72449152669
-
Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosis
-
Sarlak AY, Tosun B, Atmaca H, et al. Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosis. Eur Spine J. 2009;18:1892-1897.
-
(2009)
Eur Spine J.
, vol.18
, pp. 1892-1897
-
-
Sarlak, A.Y.1
Tosun, B.2
Atmaca, H.3
-
4
-
-
41049084632
-
Incidence and risk factors of neurological deficits of surgical correction for scoliosis: Analysis of 1373 cases at one Chinese institution
-
DOI 10.1097/BRS.0b013e3181657d93, PII 0000763220080301000013
-
Qiu Y, Wang S, Wang B, et al. Incidence and risk factors of neurological deficits of surgical correction for scoliosis: analysis of 1373 cases at one Chinese institution. Spine (Phila Pa 1976). 2008; 33:519-526. (Pubitemid 351644457)
-
(2008)
Spine
, vol.33
, Issue.5
, pp. 519-526
-
-
Qiu, Y.1
Wang, S.2
Wang, B.3
Yu, Y.4
Zhu, F.5
Zhu, Z.6
-
5
-
-
43149097597
-
Placement of pedicle screws in thoracic idiopathic scoliosis: A magnetic resonance imaging analysis of screw placement relative to structure s at risk
-
Sarlak AY, Buluc L, Sarisoy HT, et al. Placement of pedicle screws in thoracic idiopathic scoliosis: a magnetic resonance imaging analysis of screw placement relative to structure s at risk. Eur Spine J. 2008;17:657-662.
-
(2008)
Eur Spine J.
, vol.17
, pp. 657-662
-
-
Sarlak, A.Y.1
Buluc, L.2
Sarisoy, H.T.3
-
6
-
-
0043136470
-
The position of the aorta relative to the spine: A comparison of patients with and without idiopathic scoliosis
-
Sucato DJ, Duchene C. The position of the aorta relative to the spine: a comparison of patients with and without idiopathic scoliosis. J Bone Joint Surg Am. 2003;85-A:1461-1469. (Pubitemid 36951129)
-
(2003)
Journal of Bone and Joint Surgery - Series A
, vol.85
, Issue.8
, pp. 1461-1469
-
-
Sucato, D.J.1
Duchene, C.2
-
7
-
-
33645108803
-
Vascular injury and complication in neurosurgical spine surgery
-
Inamasu J, Guiot BH. Vascular injury and complication in neurosurgical spine surgery. Acta Neurochir (Wien). 2006;148: 375-387.
-
(2006)
Acta Neurochir (Wien)
, vol.148
, pp. 375-387
-
-
Inamasu, J.1
Guiot, B.H.2
-
8
-
-
50649111378
-
Delayed perforation of the aorta by a thoracic pedicle screw
-
Wegener B, Birkenmaier C, Fottner A, et al. Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J. 2008;17(suppl 2):S351-S354.
-
(2008)
Eur Spine J.
, vol.17
, Issue.SUPPL. 2
-
-
Wegener, B.1
Birkenmaier, C.2
Fottner, A.3
-
9
-
-
77957335306
-
Descending aortic injury by a thoracic pedicle screw during posteri or reconstructive surgery: A case report
-
Watanabe K, Yamazaki A, Hirano T, et al. Descending aortic injury by a thoracic pedicle screw during posteri or reconstructive surgery: a case report. Spine (Phila Pa 1976). 2010;35:E1064-E1068.
-
(2010)
Spine (Phila Pa 1976)
, vol.35
-
-
Watanabe, K.1
Yamazaki, A.2
Hirano, T.3
-
10
-
-
84860370770
-
Endovascular solutions to arterial injury due to posterior spine surgery
-
Loh SA, Maldonaldo TS, Rockman CB, et al. Endovascular solutions to arterial injury due to posterior spine surgery. J Vasc Surg. 2012;55:1477-1481.
-
(2012)
J Vasc Surg.
, vol.55
, pp. 1477-1481
-
-
Loh, S.A.1
Maldonaldo, T.S.2
Rockman, C.B.3
-
11
-
-
77954533984
-
New parameters to represent the position of the aorta relative to the spine for pedicle screw placement
-
Takeshita K, Maruyama T, Ono T, et al. New parameters to represent the position of the aorta relative to the spine for pedicle screw placement . Eur Spine J. 2010;19:815-820.
-
(2010)
Eur Spine J.
, vol.19
, pp. 815-820
-
-
Takeshita, K.1
Maruyama, T.2
Ono, T.3
-
12
-
-
84864447536
-
The position of the aorta changes with altered body position in single right thoracic adolescent idiopathic scoliosis: A magnet ic resonance imaging study
-
Jiang H, Qiu X, Wang W, et al. The position of the aorta changes with altered body position in single right thoracic adolescent idiopathic scoliosis: a magnet ic resonance imaging study. Spine (Phila Pa 1976). 2012;37:E1054-E1061.
-
(2012)
Spine (Phila Pa 1976)
, vol.37
-
-
Jiang, H.1
Qiu, X.2
Wang, W.3
-
13
-
-
0019806547
-
Estimation of vertebral rotation and the spinal and rib cage deformity in scoliosis by computer tomography
-
DOI 10.1097/00007632-198109000-00007
-
Aaro S, Dahlborn M. Estimation of vertebral rotation and the spinal and rib cage deformity in scoliosis by computer tomography. Spine (Phila Pa 1976). 1981;6:460-467. (Pubitemid 12123330)
-
(1981)
Spine
, vol.6
, Issue.5
, pp. 460-467
-
-
Aaro, S.1
Dahlborn, M.2
-
14
-
-
13444282413
-
Spatial relations between the vertebral body and the thoracic aorta in adolescent idiopathic scoliosis
-
DOI 10.1097/01.brs.0000138409.14577.f0
-
Maruyama T, Takeshita K, Nakamura K, et al. Spatial relations between the vertebral body and the thoracic aorta in adolescent idiopathic scol iosis. Spine (Phila Pa 1976). 2004;29:2067-2069. (Pubitemid 40202279)
-
(2004)
Spine
, vol.29
, Issue.18
, pp. 2067-2069
-
-
Maruyama, T.1
Takeshita, K.2
Nakamura, K.3
Kitagawa, T.4
-
15
-
-
77957752957
-
Thoracic aortic stent-graft placement for safe removal of a malpositioned pedicle screw
-
Hu HT, Shin JH, Hwang JY, et al. Thoracic aortic stent-graft placement for safe removal of a malpositioned pedicle screw. Cardiovasc Intervent Radiol. 2010;33:1040-1043.
-
(2010)
Cardiovasc Intervent Radiol.
, vol.33
, pp. 1040-1043
-
-
Hu, H.T.1
Shin, J.H.2
Hwang, J.Y.3
-
16
-
-
79957852125
-
Late diagnosis of pedicle screw malplacement with perforation of the thoracic aorta after posterior stabilization in a pa tient with multiple myeloma: Case report
-
Tschoeke SK, Gahr P, Krug L, et al. Late diagnosis of pedicle screw malplacement with perforation of the thoracic aorta after posterior stabilization in a pa tient with multiple myeloma: case report. Spine (Phila Pa 1976). 2011;36:E886-E890.
-
(2011)
Spine (Phila Pa 1976)
, vol.36
-
-
Tschoeke, S.K.1
Gahr, P.2
Krug, L.3
-
17
-
-
34249020399
-
The position of the aorta relative to the spine: Is it mobile or not?
-
DOI 10.1097/BRS.0b013e3180592c4a, PII 0000763220070520000002
-
Huitema GC, Cornips EM, Castelijns MH, et al. The position of the aorta relative to the spine: is it mobile or not? Spine (Phila Pa 1976). 2007;32:1259-1264. (Pubitemid 46791442)
-
(2007)
Spine
, vol.32
, Issue.12
, pp. 1259-1264
-
-
Huitema, G.C.1
Cornips, E.M.J.2
Castelijns, M.H.3
Van Ooij, A.4
Van Santbrink, H.5
Van Rhijn, L.W.6
-
18
-
-
82155173291
-
Clinically relevant complications related to pedicle screw placement in thoracolumbar surger y and their management: A literature review of 35,630 pedicle screws
-
Gautschi OP, Schatlo B, Schaller K, et al. Clinically relevant complications related to pedicle screw placement in thoracolumbar surger y and their management: a literature review of 35,630 pedicle screws. Neurosurg Focus. 2011;31:E8.
-
(2011)
Neurosurg Focus.
, vol.31
-
-
Gautschi, O.P.1
Schatlo, B.2
Schaller, K.3
-
19
-
-
77956416775
-
A retrospective analysis of pedicle screws in contact with the great vessels
-
Foxx KC, Kwak RC, Latzman JM, et al. A retrospective analysis of pedicle screws in contact with the great vessels. J Neurosurg Spine. 2010;13:403-406.
-
(2010)
J Neurosurg Spine.
, vol.13
, pp. 403-406
-
-
Foxx, K.C.1
Kwak, R.C.2
Latzman, J.M.3
-
20
-
-
0030064629
-
The position of the aorta in relation to the vertebra in patients with idiopathic thoracic scoliosis
-
Sevastik B, Xiong B, Hedlund R, et al. The position of the aorta in relation to the vertebra in patients with idiopathic thoracic scoliosis. Surg Radiol Anat. 1996;18:51-56. (Pubitemid 26023744)
-
(1996)
Surgical and Radiologic Anatomy
, vol.18
, Issue.1
, pp. 51-56
-
-
Sevastik, B.1
Xiong, B.2
Hedlund, R.3
Sevastik, J.4
-
21
-
-
0035101506
-
Thoracic pedicle: Surgical anatomic evaluation and relations
-
Ugur HC,Attar A,Uz A,et al.Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord. 2001;14:39-45. (Pubitemid 32162831)
-
(2001)
Journal of Spinal Disorders
, vol.14
, Issue.1
, pp. 39-45
-
-
Ugur, H.C.1
Attar, A.2
Uz, A.3
Tekdemir, I.4
Egemen, N.5
Genc, Y.6
-
22
-
-
1642505540
-
Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: Case report
-
DOI 10.1016/j.jvs.2003.10.056
-
Minor ME, Morrissey NJ, Peress R, et al. Endov ascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg. 2004;39:893-896. (Pubitemid 38405825)
-
(2004)
Journal of Vascular Surgery
, vol.39
, Issue.4
, pp. 893-896
-
-
Minor, M.E.1
Morrissey, N.J.2
Peress, R.3
Carroccio, A.4
Ellozy, S.5
Agarwal, G.6
Teodorescu, V.7
Hollier, L.H.8
Marin, M.L.9
-
23
-
-
42749084832
-
Delayed presentation of aortic injury by pedicle screws: Report of two cases and review of the literature
-
Kakkos SK, Shepard AD. Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg. 2008;47:1074-1082.
-
(2008)
J Vasc Surg.
, vol.47
, pp. 1074-1082
-
-
Kakkos, S.K.1
Shepard, A.D.2
-
24
-
-
34249085896
-
The position of the aorta relative to the spine in patients with left thoracic scoliosis: A comparison with normal patients
-
DOI 10.1097/BRS.0b013e318059aeda, PII 0000763220070520000018
-
Milbrandt TA, Sucato DJ. The position of the aorta relative to the spine in patients with left thoracic s coliosis: a comparison with normal patients. Spine (Phila Pa 1976). 2007;32:E348-E353. (Pubitemid 46791457)
-
(2007)
Spine
, vol.32
, Issue.12
-
-
Milbrandt, T.A.1
Sucato, D.J.2
-
26
-
-
84868100408
-
Comparison of the aorta impingement risks between thoracolumbar/lumbar curves with different convexities in ad olescent idiopathic scoliosis: A computed tomography study
-
Qiao J, Zhu F, Xu L, et al. Comparison of the aorta impingement risks between thoracolumbar/lumbar curves with different convexities in ad olescent idiopathic scoliosis: a computed tomography study. Eur Spine J. 2012;21:2043- 2049.
-
(2012)
Eur Spine J.
, vol.21
, pp. 2043-2049
-
-
Qiao, J.1
Zhu, F.2
Xu, L.3
|