-
1
-
-
0036719371
-
Vascular injury complicating lumbar disc surgery. A systematic review
-
Papadoulas S., Konstantinou D., Kourea H.P., Kritikos N., Haftouras N., and Tsolakis J.A. Vascular injury complicating lumbar disc surgery. A systematic review. Eur J Vasc Endovasc Surg 24 (2002) 189-195
-
(2002)
Eur J Vasc Endovasc Surg
, vol.24
, pp. 189-195
-
-
Papadoulas, S.1
Konstantinou, D.2
Kourea, H.P.3
Kritikos, N.4
Haftouras, N.5
Tsolakis, J.A.6
-
2
-
-
0029160923
-
The surgical and medical perioperative complications of anterior spinal fusion surgery in the thoracic and lumbar spine in adults. A review of 1223 procedures
-
Faciszewski T., Winter R.B., Lonstein J.E., Denis F., and Johnson L. The surgical and medical perioperative complications of anterior spinal fusion surgery in the thoracic and lumbar spine in adults. A review of 1223 procedures. Spine 20 (1995) 1592-1599
-
(1995)
Spine
, vol.20
, pp. 1592-1599
-
-
Faciszewski, T.1
Winter, R.B.2
Lonstein, J.E.3
Denis, F.4
Johnson, L.5
-
3
-
-
0022645166
-
Aortic laceration after anterior spinal fusion
-
Woolsey R.M. Aortic laceration after anterior spinal fusion. Surg Neurol 25 (1986) 267-268
-
(1986)
Surg Neurol
, vol.25
, pp. 267-268
-
-
Woolsey, R.M.1
-
4
-
-
0022501586
-
Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device: a case report
-
Jendrisak M.D. Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device: a case report. Surgery 99 (1986) 631-633
-
(1986)
Surgery
, vol.99
, pp. 631-633
-
-
Jendrisak, M.D.1
-
5
-
-
0025783912
-
Extrinsic erosion of the descending aorta by a vertebral fixator
-
Sokolic J., Sosa T., Ugljen R., Biocina B., Simunic S., and Slobodnjak Z. Extrinsic erosion of the descending aorta by a vertebral fixator. Tex Heart Inst J 18 (1991) 136-139
-
(1991)
Tex Heart Inst J
, vol.18
, pp. 136-139
-
-
Sokolic, J.1
Sosa, T.2
Ugljen, R.3
Biocina, B.4
Simunic, S.5
Slobodnjak, Z.6
-
6
-
-
0027366735
-
Penetration of a screw into the thoracic aorta in anterior spinal instrumentation. A case report
-
Matsuzaki H., Tokuhashi Y., Wakabayashi K., and Kitamura S. Penetration of a screw into the thoracic aorta in anterior spinal instrumentation. A case report. Spine 18 (1993) 2327-2331
-
(1993)
Spine
, vol.18
, pp. 2327-2331
-
-
Matsuzaki, H.1
Tokuhashi, Y.2
Wakabayashi, K.3
Kitamura, S.4
-
7
-
-
0035486958
-
Delayed aortic rupture caused by an implanted anterior spinal device. Case report
-
Ohnishi T., Neo M., Matsushita M., Komeda M., Koyama T., and Nakamura T. Delayed aortic rupture caused by an implanted anterior spinal device. Case report. J Neurosurg 95 2 suppl (2001) 253-256
-
(2001)
J Neurosurg
, vol.95
, Issue.2 SUPPL
, pp. 253-256
-
-
Ohnishi, T.1
Neo, M.2
Matsushita, M.3
Komeda, M.4
Koyama, T.5
Nakamura, T.6
-
8
-
-
0035153601
-
False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation
-
Choi J.B., Han J.O., and Jeong J.W. False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation. J Trauma 50 (2001) 140-143
-
(2001)
J Trauma
, vol.50
, pp. 140-143
-
-
Choi, J.B.1
Han, J.O.2
Jeong, J.W.3
-
9
-
-
1642505540
-
Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report
-
Minor M.E., Morrissey N.J., Peress R., Carroccio A., Ellozy S., Agarwal G., et al. Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg 39 (2004) 893-896
-
(2004)
J Vasc Surg
, vol.39
, pp. 893-896
-
-
Minor, M.E.1
Morrissey, N.J.2
Peress, R.3
Carroccio, A.4
Ellozy, S.5
Agarwal, G.6
-
10
-
-
33750321099
-
Endovascular graft for late iatrogenic vascular complication after anterior spinal instrumentation: a case report
-
Been H.D., Kerkhoffs G.M., and Balm R. Endovascular graft for late iatrogenic vascular complication after anterior spinal instrumentation: a case report. Spine 31 (2006) E856-E858
-
(2006)
Spine
, vol.31
-
-
Been, H.D.1
Kerkhoffs, G.M.2
Balm, R.3
-
11
-
-
0032891285
-
Iatrogenic upper abdominal aortic injury with pseudoaneurysm during spinal surgery
-
Lim K.E., Fan K.F., Wong Y.C., and Hsu Y.Y. Iatrogenic upper abdominal aortic injury with pseudoaneurysm during spinal surgery. J Trauma 46 (1999) 729-731
-
(1999)
J Trauma
, vol.46
, pp. 729-731
-
-
Lim, K.E.1
Fan, K.F.2
Wong, Y.C.3
Hsu, Y.Y.4
-
12
-
-
21644480528
-
Neglected major vessel injury after anterior spinal surgery: a case report
-
Aydinli U., Ozturk C., Saba D., and Ersozlu S. Neglected major vessel injury after anterior spinal surgery: a case report. Spine 29 (2004) E318-E320
-
(2004)
Spine
, vol.29
-
-
Aydinli, U.1
Ozturk, C.2
Saba, D.3
Ersozlu, S.4
-
13
-
-
34249020399
-
The position of the aorta relative to the spine: is it mobile or not?
-
Huitema G.C., Cornips E.M., Castelijns M.H., van Ooij A., van Santbrink H., and van Rhijn L.W. The position of the aorta relative to the spine: is it mobile or not?. Spine 32 (2007) 1259-1264
-
(2007)
Spine
, vol.32
, pp. 1259-1264
-
-
Huitema, G.C.1
Cornips, E.M.2
Castelijns, M.H.3
van Ooij, A.4
van Santbrink, H.5
van Rhijn, L.W.6
-
14
-
-
0029008674
-
Aortoesophageal fistula after reconstruction of the thoracic spine
-
Floch N.R., Harvey J.C., and Beattie Jr. E.J. Aortoesophageal fistula after reconstruction of the thoracic spine. Ann Thorac Surg 60 (1995) 191-192
-
(1995)
Ann Thorac Surg
, vol.60
, pp. 191-192
-
-
Floch, N.R.1
Harvey, J.C.2
Beattie Jr., E.J.3
-
16
-
-
3342979035
-
Vascular injury during anterior lumbar surgery
-
Brau S.A., Delamarter R.B., Schiffman M.L., Williams L.A., and Watkins R.G. Vascular injury during anterior lumbar surgery. Spine J 4 (2004) 409-412
-
(2004)
Spine J
, vol.4
, pp. 409-412
-
-
Brau, S.A.1
Delamarter, R.B.2
Schiffman, M.L.3
Williams, L.A.4
Watkins, R.G.5
-
17
-
-
15244362216
-
Analysis of operative complications in a series of 471 anterior lumbar interbody fusion procedures
-
Sasso R.C., Best N.M., Mummaneni P.V., Reilly T.M., and Hussain S.M. Analysis of operative complications in a series of 471 anterior lumbar interbody fusion procedures. Spine 30 (2005) 670-674
-
(2005)
Spine
, vol.30
, pp. 670-674
-
-
Sasso, R.C.1
Best, N.M.2
Mummaneni, P.V.3
Reilly, T.M.4
Hussain, S.M.5
-
18
-
-
0031000527
-
Traumatic abdominal aortic pseudoaneurysm causing biliary obstruction: a case report and review of the literature
-
Chase C.W., Layman T.S., Barker D.E., and Clements J.B. Traumatic abdominal aortic pseudoaneurysm causing biliary obstruction: a case report and review of the literature. J Vasc Surg 25 (1997) 936-940
-
(1997)
J Vasc Surg
, vol.25
, pp. 936-940
-
-
Chase, C.W.1
Layman, T.S.2
Barker, D.E.3
Clements, J.B.4
-
19
-
-
0021238332
-
Chronic traumatic aneurysm of the descending thoracic aorta with compression of the tracheobronchial tree
-
Verdant A. Chronic traumatic aneurysm of the descending thoracic aorta with compression of the tracheobronchial tree. Can J Surg 27 (1984) 278-279
-
(1984)
Can J Surg
, vol.27
, pp. 278-279
-
-
Verdant, A.1
-
20
-
-
33646479630
-
Stent versus open surgery for acute and chronic traumatic injury of the thoracic aorta: a single-center experience
-
Andrassy J., Weidenhagen R., Meimarakis G., Lauterjung L., Jauch K.W., and Kopp R. Stent versus open surgery for acute and chronic traumatic injury of the thoracic aorta: a single-center experience. J Trauma 60 (2006) 765-772
-
(2006)
J Trauma
, vol.60
, pp. 765-772
-
-
Andrassy, J.1
Weidenhagen, R.2
Meimarakis, G.3
Lauterjung, L.4
Jauch, K.W.5
Kopp, R.6
-
21
-
-
9644290698
-
Delayed development of infrarenal abdominal aortic pseudoaneurysm after blunt trauma: a case report and review of the literature
-
Raghavendran K., Singh G., Arnoldo B., and Flynn W.J. Delayed development of infrarenal abdominal aortic pseudoaneurysm after blunt trauma: a case report and review of the literature. J Trauma 57 (2004) 1111-1114
-
(2004)
J Trauma
, vol.57
, pp. 1111-1114
-
-
Raghavendran, K.1
Singh, G.2
Arnoldo, B.3
Flynn, W.J.4
-
22
-
-
34247393307
-
Pseudoaneurysm of the abdominal aorta due to a needle-like osteophyte on the first lumbar vertebra
-
Dregelid E., Jenssen G., Jonung T., and Braaten A. Pseudoaneurysm of the abdominal aorta due to a needle-like osteophyte on the first lumbar vertebra. J Vasc Surg 45 (2007) 1059-1061
-
(2007)
J Vasc Surg
, vol.45
, pp. 1059-1061
-
-
Dregelid, E.1
Jenssen, G.2
Jonung, T.3
Braaten, A.4
-
23
-
-
0027172355
-
Abdominal aortic pseudoaneurysm after blunt trauma
-
Pisters P.W., Heslin M.J., and Riles T.S. Abdominal aortic pseudoaneurysm after blunt trauma. J Vasc Surg 18 (1993) 307-309
-
(1993)
J Vasc Surg
, vol.18
, pp. 307-309
-
-
Pisters, P.W.1
Heslin, M.J.2
Riles, T.S.3
-
24
-
-
0036718916
-
Successful surgical treatment of chronic traumatic thoracic aneurysm in two patients
-
Kaminishi Y., Saito T., Kato M., Kamisawa O., Misawa Y., and Fuse K. Successful surgical treatment of chronic traumatic thoracic aneurysm in two patients. Jpn J Thorac Cardiovasc Surg 50 (2002) 375-377
-
(2002)
Jpn J Thorac Cardiovasc Surg
, vol.50
, pp. 375-377
-
-
Kaminishi, Y.1
Saito, T.2
Kato, M.3
Kamisawa, O.4
Misawa, Y.5
Fuse, K.6
-
25
-
-
0036815588
-
Endovascular exclusion of a ruptured pseudoaneurysm of the infrarenal abdominal aorta secondary to pancreatitis
-
Hinchliffe R.J., Yung M., and Hopkinson B.R. Endovascular exclusion of a ruptured pseudoaneurysm of the infrarenal abdominal aorta secondary to pancreatitis. J Endovasc Ther 9 (2002) 590-592
-
(2002)
J Endovasc Ther
, vol.9
, pp. 590-592
-
-
Hinchliffe, R.J.1
Yung, M.2
Hopkinson, B.R.3
-
26
-
-
0013951855
-
False aneurysm of the aorta following penetrating trauma. Report of a case with secondary infection and delayed rupture
-
Cherry J.K., and Bennett D.E. False aneurysm of the aorta following penetrating trauma. Report of a case with secondary infection and delayed rupture. Arch Surg 93 (1966) 404-408
-
(1966)
Arch Surg
, vol.93
, pp. 404-408
-
-
Cherry, J.K.1
Bennett, D.E.2
-
27
-
-
0031413907
-
Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis
-
Liljenqvist U.R., Halm H.F., and Link T.M. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 22 (1997) 2239-2245
-
(1997)
Spine
, vol.22
, pp. 2239-2245
-
-
Liljenqvist, U.R.1
Halm, H.F.2
Link, T.M.3
-
28
-
-
0035884966
-
Thoracic pedicle screw fixation in spinal deformities: are they really safe?
-
Suk S.I., Kim W.J., Lee S.M., Kim J.H., and Chung E.R. Thoracic pedicle screw fixation in spinal deformities: are they really safe?. Spine 26 (2001) 2049-2057
-
(2001)
Spine
, vol.26
, pp. 2049-2057
-
-
Suk, S.I.1
Kim, W.J.2
Lee, S.M.3
Kim, J.H.4
Chung, E.R.5
-
29
-
-
0034099254
-
Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine
-
Wiesner L., Kothe R., Schulitz K.P., and Ruther W. Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine 25 (2000) 615-621
-
(2000)
Spine
, vol.25
, pp. 615-621
-
-
Wiesner, L.1
Kothe, R.2
Schulitz, K.P.3
Ruther, W.4
-
30
-
-
0027252714
-
CT analysis of pedicles and screw tracts after implant removal in thoracolumbar fractures
-
Sjostrom L., Jacobsson O., Karlstrom G., Pech P., and Rauschning W. CT analysis of pedicles and screw tracts after implant removal in thoracolumbar fractures. J Spinal Disord 6 (1993) 225-231
-
(1993)
J Spinal Disord
, vol.6
, pp. 225-231
-
-
Sjostrom, L.1
Jacobsson, O.2
Karlstrom, G.3
Pech, P.4
Rauschning, W.5
-
31
-
-
14844302180
-
Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees
-
Kuklo T.R., Lenke L.G., O'Brien M.F., Lehman Jr. R.A., Polly Jr. D.W., and Schroeder T.M. Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees. Spine 30 (2005) 222-226
-
(2005)
Spine
, vol.30
, pp. 222-226
-
-
Kuklo, T.R.1
Lenke, L.G.2
O'Brien, M.F.3
Lehman Jr., R.A.4
Polly Jr., D.W.5
Schroeder, T.M.6
-
32
-
-
27644543217
-
Thoracic vertebral screw impingement on the aorta in an in vivo bovine model
-
Faro F.D., Farnsworth C.L., Shapiro G.S., Mohamad F., White K.K., Breisch E., et al. Thoracic vertebral screw impingement on the aorta in an in vivo bovine model. Spine 30 (2005) 2406-2413
-
(2005)
Spine
, vol.30
, pp. 2406-2413
-
-
Faro, F.D.1
Farnsworth, C.L.2
Shapiro, G.S.3
Mohamad, F.4
White, K.K.5
Breisch, E.6
-
33
-
-
33644875119
-
Accuracy and safety of thoracic pedicle screw placement in spinal deformities
-
Smorgick Y., Millgram M.A., Anekstein Y., Floman Y., and Mirovsky Y. Accuracy and safety of thoracic pedicle screw placement in spinal deformities. J Spinal Disord Tech 18 (2005) 522-526
-
(2005)
J Spinal Disord Tech
, vol.18
, pp. 522-526
-
-
Smorgick, Y.1
Millgram, M.A.2
Anekstein, Y.3
Floman, Y.4
Mirovsky, Y.5
-
34
-
-
1442360627
-
Analysis of screw placement relative to the aorta and spinal canal following anterior instrumentation for thoracic idiopathic scoliosis
-
Sucato D.J., Kassab F., and Dempsey M. Analysis of screw placement relative to the aorta and spinal canal following anterior instrumentation for thoracic idiopathic scoliosis. Spine 29 (2004) 554-559
-
(2004)
Spine
, vol.29
, pp. 554-559
-
-
Sucato, D.J.1
Kassab, F.2
Dempsey, M.3
-
35
-
-
33745712005
-
Screw position after double-rod anterior spinal fusion in idiopathic scoliosis: an evaluation using computerized tomography
-
Huitema G.C., van Rhijn L.W., and van Ooij A. Screw position after double-rod anterior spinal fusion in idiopathic scoliosis: an evaluation using computerized tomography. Spine 31 (2006) 1734-1739
-
(2006)
Spine
, vol.31
, pp. 1734-1739
-
-
Huitema, G.C.1
van Rhijn, L.W.2
van Ooij, A.3
-
36
-
-
13444282413
-
Spatial relations between the vertebral body and the thoracic aorta in adolescent idiopathic scoliosis
-
Maruyama T., Takeshita K., Nakamura K., and Kitagawa T. Spatial relations between the vertebral body and the thoracic aorta in adolescent idiopathic scoliosis. Spine 29 (2004) 2067-2069
-
(2004)
Spine
, vol.29
, pp. 2067-2069
-
-
Maruyama, T.1
Takeshita, K.2
Nakamura, K.3
Kitagawa, T.4
-
37
-
-
21344459000
-
Structures at risk following anterior instrumented spinal fusion for thoracic adolescent idiopathic scoliosis
-
Kuklo T.R., Lehman Jr. R.A., and Lenke L.G. Structures at risk following anterior instrumented spinal fusion for thoracic adolescent idiopathic scoliosis. J Spinal Disord Tech 18 suppl 1 (2005) S58-S64
-
(2005)
J Spinal Disord Tech
, vol.18
, Issue.SUPPL. 1
-
-
Kuklo, T.R.1
Lehman Jr., R.A.2
Lenke, L.G.3
-
38
-
-
0043136470
-
The position of the aorta relative to the spine: a comparison of patients with and without idiopathic scoliosis
-
Sucato D.J., and Duchene C. The position of the aorta relative to the spine: a comparison of patients with and without idiopathic scoliosis. J Bone Joint Surg Am 85 (2003) 1461-1469
-
(2003)
J Bone Joint Surg Am
, vol.85
, pp. 1461-1469
-
-
Sucato, D.J.1
Duchene, C.2
-
39
-
-
34249085896
-
The position of the aorta relative to the spine in patients with left thoracic scoliosis: a comparison with normal patients
-
Milbrandt T.A., and Sucato D.J. The position of the aorta relative to the spine in patients with left thoracic scoliosis: a comparison with normal patients. Spine 32 (2007) E348-E353
-
(2007)
Spine
, vol.32
-
-
Milbrandt, T.A.1
Sucato, D.J.2
-
40
-
-
33745697975
-
The position of the aorta relative to the spine before and after anterior instrumentation in right thoracic scoliosis
-
Bullmann V., Fallenberg E.M., Meier N., Fischbach R., Lerner T., Schulte T.L., et al. The position of the aorta relative to the spine before and after anterior instrumentation in right thoracic scoliosis. Spine 31 (2006) 1706-1713
-
(2006)
Spine
, vol.31
, pp. 1706-1713
-
-
Bullmann, V.1
Fallenberg, E.M.2
Meier, N.3
Fischbach, R.4
Lerner, T.5
Schulte, T.L.6
-
41
-
-
0031905701
-
Ruptured aortic pseudoaneurysm 28 years after gunshot wound: case report and review of the literature
-
Miller J.S., Wall Jr. M.J., and Mattox K.L. Ruptured aortic pseudoaneurysm 28 years after gunshot wound: case report and review of the literature. J Trauma 44 (1998) 214-216
-
(1998)
J Trauma
, vol.44
, pp. 214-216
-
-
Miller, J.S.1
Wall Jr., M.J.2
Mattox, K.L.3
-
42
-
-
27644504267
-
Endovascular repair of an actively hemorrhaging gunshot injury to the abdominal aorta
-
Yeh M.W., Horn J.K., Schecter W.P., Chuter T.A., and Lane J.S. Endovascular repair of an actively hemorrhaging gunshot injury to the abdominal aorta. J Vasc Surg 42 (2005) 1007-1009
-
(2005)
J Vasc Surg
, vol.42
, pp. 1007-1009
-
-
Yeh, M.W.1
Horn, J.K.2
Schecter, W.P.3
Chuter, T.A.4
Lane, J.S.5
-
43
-
-
0033375530
-
Posttraumatic infrarenal abdominal aortic pseudoaneurysm
-
Borioni R., Garofalo M., Seddio F., Colagrande L., Marino B., and Albano P. Posttraumatic infrarenal abdominal aortic pseudoaneurysm. Tex Heart Inst J 26 (1999) 312-314
-
(1999)
Tex Heart Inst J
, vol.26
, pp. 312-314
-
-
Borioni, R.1
Garofalo, M.2
Seddio, F.3
Colagrande, L.4
Marino, B.5
Albano, P.6
-
44
-
-
27644595452
-
Successful treatment of a tuberculous vertebral osteomyelitis eroding the thoracoabdominal aorta: a case report
-
Falkensammer J., Behensky H., Gruber H., Prodinger W.M., and Fraedrich G. Successful treatment of a tuberculous vertebral osteomyelitis eroding the thoracoabdominal aorta: a case report. J Vasc Surg 42 (2005) 1010-1013
-
(2005)
J Vasc Surg
, vol.42
, pp. 1010-1013
-
-
Falkensammer, J.1
Behensky, H.2
Gruber, H.3
Prodinger, W.M.4
Fraedrich, G.5
-
45
-
-
0141871982
-
Distal aortic perfusion and cerebrospinal fluid drainage for thoracoabdominal and descending thoracic aortic repair: ten years of organ protection
-
Safi H.J., Miller III C.C., Huynh T.T., Estrera A.L., Porat E.E., Winnerkvist A.N., et al. Distal aortic perfusion and cerebrospinal fluid drainage for thoracoabdominal and descending thoracic aortic repair: ten years of organ protection. Ann Surg 238 (2003) 372-381
-
(2003)
Ann Surg
, vol.238
, pp. 372-381
-
-
Safi, H.J.1
Miller III, C.C.2
Huynh, T.T.3
Estrera, A.L.4
Porat, E.E.5
Winnerkvist, A.N.6
-
46
-
-
3042517458
-
Repair of the torn descending thoracic aorta using the centrifugal pump for partial left heart bypass
-
Moore E.E., Burch J.M., and Moore J.B. Repair of the torn descending thoracic aorta using the centrifugal pump for partial left heart bypass. Ann Surg 240 (2004) 38-43
-
(2004)
Ann Surg
, vol.240
, pp. 38-43
-
-
Moore, E.E.1
Burch, J.M.2
Moore, J.B.3
-
47
-
-
1242309468
-
Treatment of massive thoracolumbar wounds and vertebral osteomyelitis following scoliosis surgery
-
Mitra A., Mitra A., and Harlin S. Treatment of massive thoracolumbar wounds and vertebral osteomyelitis following scoliosis surgery. Plast Reconstr Surg 113 (2004) 206-213
-
(2004)
Plast Reconstr Surg
, vol.113
, pp. 206-213
-
-
Mitra, A.1
Mitra, A.2
Harlin, S.3
-
48
-
-
0018905022
-
Traumatic pseudoaneurysm of the thoracic aorta in close proximity to the anterior spinal artery: a therapeutic dilemma
-
Harrington D.P., Barth K.H., White Jr. R.I., and Brawley R.K. Traumatic pseudoaneurysm of the thoracic aorta in close proximity to the anterior spinal artery: a therapeutic dilemma. Surgery 87 (1980) 153-156
-
(1980)
Surgery
, vol.87
, pp. 153-156
-
-
Harrington, D.P.1
Barth, K.H.2
White Jr., R.I.3
Brawley, R.K.4
-
49
-
-
34548570922
-
The anatomical relationship between the aorta and the thoracic vertebral bodies and its importance in the placement of the screw in thoracoscopic correction of scoliosis
-
Qiu Y., He Y.X., Wang B., Zhu F., and Wang W.J. The anatomical relationship between the aorta and the thoracic vertebral bodies and its importance in the placement of the screw in thoracoscopic correction of scoliosis. Eur Spine J 16 (2007) 1367-1372
-
(2007)
Eur Spine J
, vol.16
, pp. 1367-1372
-
-
Qiu, Y.1
He, Y.X.2
Wang, B.3
Zhu, F.4
Wang, W.J.5
-
50
-
-
0037221654
-
Guide device for percutaneous placement of translaminar facet screws after anterior lumbar interbody fusion. Technical note
-
Jang J.S., Lee S.H., and Lim S.R. Guide device for percutaneous placement of translaminar facet screws after anterior lumbar interbody fusion. Technical note. J Neurosurg 98 1 suppl (2003) 100-103
-
(2003)
J Neurosurg
, vol.98
, Issue.1 SUPPL
, pp. 100-103
-
-
Jang, J.S.1
Lee, S.H.2
Lim, S.R.3
-
51
-
-
16844373744
-
Fluoroscopically assisted percutaneous translaminar facet screw fixation following anterior lumbar interbody fusion: technical report
-
Shim C.S., Lee S.H., Jung B., Sivasabaapathi P., Park S.H., and Shin S.W. Fluoroscopically assisted percutaneous translaminar facet screw fixation following anterior lumbar interbody fusion: technical report. Spine 30 (2005) 838-843
-
(2005)
Spine
, vol.30
, pp. 838-843
-
-
Shim, C.S.1
Lee, S.H.2
Jung, B.3
Sivasabaapathi, P.4
Park, S.H.5
Shin, S.W.6
-
52
-
-
34447526747
-
Computed tomography-guided percutaneous facet screw fixation in the lumbar spine. Technical note
-
Kang H.Y., Lee S.H., Jeon S.H., and Shin S.W. Computed tomography-guided percutaneous facet screw fixation in the lumbar spine. Technical note. J Neurosurg Spine 7 (2007) 95-98
-
(2007)
J Neurosurg Spine
, vol.7
, pp. 95-98
-
-
Kang, H.Y.1
Lee, S.H.2
Jeon, S.H.3
Shin, S.W.4
-
53
-
-
18144367767
-
Accuracy of single-time, multilevel registration in image-guided spinal surgery
-
Papadopoulos E.C., Girardi F.P., Sama A., Sandhu H.S., and Cammisa Jr. F.P. Accuracy of single-time, multilevel registration in image-guided spinal surgery. Spine J 5 (2005) 263-268
-
(2005)
Spine J
, vol.5
, pp. 263-268
-
-
Papadopoulos, E.C.1
Girardi, F.P.2
Sama, A.3
Sandhu, H.S.4
Cammisa Jr., F.P.5
-
54
-
-
33748579924
-
Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part I-technical development and a test case result
-
Lieberman I.H., Togawa D., Kayanja M.M., Reinhardt M.K., Friedlander A., Knoller N., et al. Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part I-technical development and a test case result. Neurosurgery 59 (2006) 641-650
-
(2006)
Neurosurgery
, vol.59
, pp. 641-650
-
-
Lieberman, I.H.1
Togawa, D.2
Kayanja, M.M.3
Reinhardt, M.K.4
Friedlander, A.5
Knoller, N.6
-
55
-
-
33847004722
-
Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2-evaluation of system accuracy
-
Togawa D., Kayanja M.M., Reinhardt M.K., Shoham M., Balter A., Friedlander A., et al. Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2-evaluation of system accuracy. Neurosurgery 60 suppl 1 (2007) ONS129-ONS139
-
(2007)
Neurosurgery
, vol.60
, Issue.SUPPL. 1
-
-
Togawa, D.1
Kayanja, M.M.2
Reinhardt, M.K.3
Shoham, M.4
Balter, A.5
Friedlander, A.6
-
56
-
-
33750075179
-
Miniature robotic guidance for spine surgery-introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres
-
Barzilay Y., Liebergall M., Fridlander A., and Knoller N. Miniature robotic guidance for spine surgery-introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres. Int J Med Robot 2 (2006) 146-153
-
(2006)
Int J Med Robot
, vol.2
, pp. 146-153
-
-
Barzilay, Y.1
Liebergall, M.2
Fridlander, A.3
Knoller, N.4
-
57
-
-
33750052901
-
Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist
-
Sukovich W., Brink-Danan S., and Hardenbrook M. Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist. Int J Med Robot 2 (2006) 114-122
-
(2006)
Int J Med Robot
, vol.2
, pp. 114-122
-
-
Sukovich, W.1
Brink-Danan, S.2
Hardenbrook, M.3
-
58
-
-
0022553959
-
Anterior spine stabilization and decompression for thoracolumbar injuries
-
Dunn H.K. Anterior spine stabilization and decompression for thoracolumbar injuries. Orthop Clin North Am 17 (1986) 113-119
-
(1986)
Orthop Clin North Am
, vol.17
, pp. 113-119
-
-
Dunn, H.K.1
|