Late diagnosis of pedicle screw malplacement with perforation of the thoracic aorta after posterior stabilization in a patient with multiple myeloma: Case report

Author keywords

multiple myeloma; pedicle screw; Posterior stabilization; thoracic spine; vascular injury

Indexed keywords

ADULT; AORTA PERFORATION; ARTICLE; BACKACHE; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; DELAYED DIAGNOSIS; DIFFUSION WEIGHTED IMAGING; FEMALE; FLUOROSCOPY; HUMAN; KYPHOSIS; MULTIPLE MYELOMA; OPERATION DURATION; ORTHOPEDIC EQUIPMENT; PATIENT MONITORING; PEDICLE SCREW; PEDICLE SCREW MALPOSITIONING; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; REOPERATION; SPINE SURGERY; THORACIC AORTA; THORACIC SPINE; THORACOTOMY; TREATMENT PLANNING; VERTEBRA BODY;

EID: 79957852125     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e318202e4d1     Document Type: Article
Times cited : (21)

References (22)
  • 1
    • 84940622010 scopus 로고
    • Relations of the soft structures of the posterior mediastinum in the scoliotic spine
    • Nathan H. Relations of the soft structures of the posterior mediastinum in the scoliotic spine. Acta Anat (Basel) 1988;133:260-4. (Pubitemid 19030657)
    • (1988) Acta Anatomica , vol.133 , Issue.3 , pp. 260-264
    • Nathan, H.1
  • 2
    • 0029156076 scopus 로고
    • Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae
    • Vaccaro AR, Rizzolo SJ, Allardyce TJ, et al. Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 1995;77:1193-9.
    • (1995) J. Bone Joint Surg. Am. , vol.77 , pp. 1193-1199
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Allardyce, T.J.3
  • 3
    • 0029098570 scopus 로고
    • Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment
    • Vaccaro AR, Rizzolo SJ, Balderston RA, et al. Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 1995;77:1200-6.
    • (1995) J. Bone Joint Surg. Am. , vol.77 , pp. 1200-1206
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Balderston, R.A.3
  • 4
    • 0030937517 scopus 로고    scopus 로고
    • Upper abdominal aortic injury during spinal surgery
    • Smythe WR, Carpenter JP. Upper abdominal aortic injury during spinal surgery. J Vasc Surg 1997;25:774-7. (Pubitemid 27190947)
    • (1997) Journal of Vascular Surgery , vol.25 , Issue.4 , pp. 774-777
    • Smythe, W.R.1    Carpenter, J.P.2
  • 5
    • 0031012808 scopus 로고    scopus 로고
    • Potential large vessel injury during thoracolumbar pedicle screw removal: A case report
    • DOI 10.1097/00007632-199701010-00018
    • Vanichkachorn JS, Vaccaro AR, Cohen MJ, et al. Potential large vessel injury during thoracolumbar pedicle screw removal. A case report. Spine (Phila Pa 1976) 1997;22:110-3. (Pubitemid 27044845)
    • (1997) Spine , vol.22 , Issue.1 , pp. 110-113
    • Vanichkachorn, J.S.1    Vaccaro, A.R.2    Cohen, M.J.3    Cotler, J.M.4
  • 7
    • 77954099030 scopus 로고    scopus 로고
    • Kyphoplasty for spinal fractures from multiple myeloma
    • Zou J, Mei X, Gan M, et al. Kyphoplasty for spinal fractures from multiple myeloma. J Surg Oncol 102:43-7.
    • J. Surg. Oncol. , vol.102 , pp. 43-47
    • Zou, J.1    Mei, X.2    Gan, M.3
  • 8
    • 0022501586 scopus 로고
    • Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device. A case report
    • Jendrisak MD. Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device: a case report. Surgery 1986;99:631-3. (Pubitemid 16024073)
    • (1986) Surgery , vol.99 , Issue.5 , pp. 631-633
    • Jendrisak, M.D.1
  • 10
    • 0022645166 scopus 로고
    • Aortic laceration after anterior spinal fusion
    • DOI 10.1016/0090-3019(86)90237-5
    • Woolsey RM. Aortic laceration after anterior spinal fusion. Surg Neurol 1986;25:267-8. (Pubitemid 16175902)
    • (1986) Surgical Neurology , vol.25 , Issue.3 , pp. 267-268
    • Woolsey, R.M.1
  • 11
    • 0027366735 scopus 로고
    • Penetration of a screw into the thoracic aorta in anterior spinal instrumentation: A case report
    • Matsuzaki H, Tokuhashi Y, Wakabayashi K, et al. Penetration of a screw into the thoracic aorta in anterior spinal instrumentation. A case report. Spine (Phila Pa 1976) 1993;18:2327-31. (Pubitemid 23336077)
    • (1993) Spine , vol.18 , Issue.15 , pp. 2327-2331
    • Matsuzaki, H.1    Tokuhashi, Y.2    Wakabayashi, K.3    Kitamura, S.4
  • 12
    • 50649111378 scopus 로고    scopus 로고
    • Delayed perforation of the aorta by a thoracic pedicle screw
    • Wegener B, Birkenmaier C, Fottner A, et al. Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J 2008;17(suppl 2): S351-4.
    • (2008) Eur. Spine J. , vol.17 , Issue.2 SUPPL.
    • Wegener, B.1    Birkenmaier, C.2    Fottner, A.3
  • 13
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • DOI 10.1097/00007632-200003010-00012
    • Amiot LP, Lang K, Putzier M, et al. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976) 2000;25:606-14. (Pubitemid 30158220)
    • (2000) Spine , vol.25 , Issue.5 , pp. 606-614
    • Amiot, L.-P.1    Lang, K.2    Putzier, M.3    Zippel, H.4    Labelle, H.5
  • 14
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 2000;9:235-40.
    • (2000) Eur. Spine J. , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 15
    • 33846239956 scopus 로고    scopus 로고
    • Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
    • DOI 10.1097/01.brs.0000252094.64857.ab, PII 0000763220070115000030
    • Rajasekaran S, Vidyadhara S, Ramesh P, et al. Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 2007;32: E56-64. (Pubitemid 46105794)
    • (2007) Spine , vol.32 , Issue.2
    • Rajasekaran, S.1    Vidyadhara, S.2    Ramesh, P.3    Shetty, A.P.4
  • 16
    • 10944236094 scopus 로고    scopus 로고
    • Computer-assisted fluoroscopic navigation of pedicle screw insertion: An in vivo feasibility study
    • Fu TS, Chen LH, Wong CB, et al. Computer-assisted fluoroscopic navigation of pedicle screw insertion: an in vivo feasibility study. Acta Orthop Scand 2004;75:730-5.
    • (2004) Acta Orthop. Scand. , vol.75 , pp. 730-735
    • Fu, T.S.1    Chen, L.H.2    Wong, C.B.3
  • 18
    • 0037442352 scopus 로고    scopus 로고
    • Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: A cadaver study
    • DOI 10.1097/00007632-200302150-00018
    • Mirza SK, Wiggins GC, Kuntz Ct, et al. Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine (Phila Pa 1976) 2003;28:402-13. (Pubitemid 36232625)
    • (2003) Spine , vol.28 , Issue.4 , pp. 402-413
    • Mirza, S.K.1    Wiggins, G.C.2    Kuntz IV, C.3    York, J.E.4    Bellabarba, C.5    Knonodi, M.A.6    Chapman, J.R.7    Shaffrey, C.I.8
  • 19
    • 68349104323 scopus 로고    scopus 로고
    • Image-guided pedicle screw insertion accuracy: A meta-analysis
    • Tian NF, Xu HZ. Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 2009;33:895-903.
    • (2009) Int. Orthop. , vol.33 , pp. 895-903
    • Tian, N.F.1    Xu, H.Z.2
  • 20
    • 0345688754 scopus 로고    scopus 로고
    • Präzision der navigationsgestützten chirurgie an der brust- und lendenwirbelsäule
    • Arand M, Schempf M, Hebold D, et al. [Precision of navigationassisted surgery of the thoracic and lumbar spine]. Unfallchirurg 2003;106:899-906. (Pubitemid 37444152)
    • (2003) Unfallchirurg , vol.106 , Issue.11 , pp. 899-906
    • Arand, M.1    Schempf, M.2    Hebold, D.3    Teller, S.4    Kinzl, L.5    Gebhard, F.6
  • 22
    • 77957752957 scopus 로고    scopus 로고
    • Thoracic aortic stent-graft placement for safe removal of a malpositioned pedicle screw
    • Hu HT, Shin JH, Hwang JY, et al. Thoracic aortic stent-graft placement for safe removal of a malpositioned pedicle screw. Cardiovasc Intervent Radiol 2010;33(5):1040-3.
    • (2010) Cardiovasc. Intervent Radiol. , vol.33 , Issue.5 , pp. 1040-1043
    • Hu, H.T.1    Shin, J.H.2    Hwang, J.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.