메뉴 건너뛰기




Volumn , Issue , 2008, Pages 173-193

Surface modification of Ti-Ni alloys for biomedical applications

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM NITRIDE; BINARY ALLOYS; BIOHAZARDS; CORROSION PREVENTION; ELECTROLYTIC POLISHING; MEDICAL APPLICATIONS; NICKEL ALLOYS; OXIDE FILMS; SURFACE TREATMENT; TITANIUM OXIDES;

EID: 84902406582     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1533/9781845695248.1.173     Document Type: Chapter
Times cited : (15)

References (108)
  • 1
    • 38049094438 scopus 로고    scopus 로고
    • Shape memory alloys - medical applications
    • Anson T. Shape memory alloys - medical applications. Mater World 1999, 7(12):745-747.
    • (1999) Mater World , vol.7 , Issue.12 , pp. 745-747
    • Anson, T.1
  • 2
    • 0039171080 scopus 로고    scopus 로고
    • An overview of nitinol medical applications
    • Duerig T., Pelton A., Stöckel D. An overview of nitinol medical applications. Mater Sci Eng A 1999, 273-275:149-160.
    • (1999) Mater Sci Eng A , pp. 149-160
    • Duerig, T.1    Pelton, A.2    Stöckel, D.3
  • 4
    • 0142101894 scopus 로고    scopus 로고
    • Porous titanium-nickel for intervertebral fusion in a sheep model: Part 2. Surface analysis and nickel release assessment
    • Assad M., Chernyshov A.V., Jarzem P., Leroux M.A., Coillard C., Charette S., Rivard C.H. Porous titanium-nickel for intervertebral fusion in a sheep model: Part 2. Surface analysis and nickel release assessment. J Biomed Mater Res 2003, 64B(2):121-129.
    • (2003) J Biomed Mater Res , vol.64 B , Issue.2 , pp. 121-129
    • Assad, M.1    Chernyshov, A.V.2    Jarzem, P.3    Leroux, M.A.4    Coillard, C.5    Charette, S.6    Rivard, C.H.7
  • 7
    • 0034774586 scopus 로고    scopus 로고
    • Growth inhibition of cultured smooth muscle cells by corrosion products of 316L stainless-steel wire
    • Shih C.C., Shih C.M., Chen Y.L., Su Y.Y., Shih J.S., Kwok C.F., Lin S.J. Growth inhibition of cultured smooth muscle cells by corrosion products of 316L stainless-steel wire. J Biomed Mater Res 2001, 57(2):200-207.
    • (2001) J Biomed Mater Res , vol.57 , Issue.2 , pp. 200-207
    • Shih, C.C.1    Shih, C.M.2    Chen, Y.L.3    Su, Y.Y.4    Shih, J.S.5    Kwok, C.F.6    Lin, S.J.7
  • 9
    • 0034333624 scopus 로고    scopus 로고
    • Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide
    • Shih C.-C., Lin S.-J., Chung K.-H., Chen Y.-L., Su Y.-Y. Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide. J Biomed Mater Res 2000, 52(2):323-332.
    • (2000) J Biomed Mater Res , vol.52 , Issue.2 , pp. 323-332
    • Shih, C.-C.1    Lin, S.-J.2    Chung, K.-H.3    Chen, Y.-L.4    Su, Y.-Y.5
  • 11
    • 0346244109 scopus 로고    scopus 로고
    • Surface conditions of Nitinol wires, tubing, and as-cast alloys. The effect of chemical etching, aging in boiling water, and heat treatment
    • Shabalovskaya S.A., Anderegg J., Laab F., Thiel P.A., Rondelli G. Surface conditions of Nitinol wires, tubing, and as-cast alloys. The effect of chemical etching, aging in boiling water, and heat treatment. J Biomed Mater Res B Appl Biomater 2003, 65(1):193-203.
    • (2003) J Biomed Mater Res B Appl Biomater , vol.65 , Issue.1 , pp. 193-203
    • Shabalovskaya, S.A.1    Anderegg, J.2    Laab, F.3    Thiel, P.A.4    Rondelli, G.5
  • 13
    • 34547888787 scopus 로고    scopus 로고
    • The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation
    • Peitsch T., Klocke A., Kahl-Nieke B., Prymak O., Epple M. The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation. J Biomed Mater Res A 2007, 82A(3):731-739.
    • (2007) J Biomed Mater Res A , vol.82 A , Issue.3 , pp. 731-739
    • Peitsch, T.1    Klocke, A.2    Kahl-Nieke, B.3    Prymak, O.4    Epple, M.5
  • 15
    • 0032090001 scopus 로고    scopus 로고
    • Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications
    • Trigwell S., Hayden R.D., Nelson K.F., Selvaduray G. Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications. Surf Interface Anal 1998, 26(7):483-489.
    • (1998) Surf Interface Anal , vol.26 , Issue.7 , pp. 483-489
    • Trigwell, S.1    Hayden, R.D.2    Nelson, K.F.3    Selvaduray, G.4
  • 16
    • 2442440803 scopus 로고    scopus 로고
    • Comparative corrosion performance of black oxide, sandblasted, and fine-drawn nitinol wires in potentiodynamic and potentiostatic tests: Effects of chemical etching and electropolishing
    • Shabalovskaya S., Rondelli G., Anderegg J., Xiong J.P., Wu M. Comparative corrosion performance of black oxide, sandblasted, and fine-drawn nitinol wires in potentiodynamic and potentiostatic tests: Effects of chemical etching and electropolishing. J Biomed Mater Res 2004, 69B(2):223-231.
    • (2004) J Biomed Mater Res , vol.69 B , Issue.2 , pp. 223-231
    • Shabalovskaya, S.1    Rondelli, G.2    Anderegg, J.3    Xiong, J.P.4    Wu, M.5
  • 17
    • 0036013926 scopus 로고    scopus 로고
    • On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility
    • Es-Souni M., Es-Souni M., Fischer-Brandies H. On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility. Biomaterials 2002, 23(14):2887-2894.
    • (2002) Biomaterials , vol.23 , Issue.14 , pp. 2887-2894
    • Es-Souni, M.1    Es-Souni, M.2    Fischer-Brandies, H.3
  • 18
    • 0035691819 scopus 로고    scopus 로고
    • Surface conditioning of nickel-titanium alloy stents for improving biocompatibility
    • Zhao H., Van Humbeeck J., De Scheerder I. Surface conditioning of nickel-titanium alloy stents for improving biocompatibility. Surf Eng 2001, 17(6):451-458.
    • (2001) Surf Eng , vol.17 , Issue.6 , pp. 451-458
    • Zhao, H.1    Van Humbeeck, J.2    De Scheerder, I.3
  • 19
    • 0036179018 scopus 로고    scopus 로고
    • Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
    • Shabalovskaya S.A. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material. Biomed Mater Eng 2002, 12(1):69-109.
    • (2002) Biomed Mater Eng , vol.12 , Issue.1 , pp. 69-109
    • Shabalovskaya, S.A.1
  • 20
    • 0033990205 scopus 로고    scopus 로고
    • Effects of sterilization processes on NiTi alloy: surface characterization
    • Thierry B., Tabrizian M., Savadogo O., Yahia L. Effects of sterilization processes on NiTi alloy: surface characterization. J Biomed Mater Res 2000, 49(1):88-98.
    • (2000) J Biomed Mater Res , vol.49 , Issue.1 , pp. 88-98
    • Thierry, B.1    Tabrizian, M.2    Savadogo, O.3    Yahia, L.4
  • 21
    • 0037026414 scopus 로고    scopus 로고
    • Effect of surface treatment of NiTi alloy on its corrosion behaviour in Hanks' solution
    • Cissé O., Savadogo O., Wu M., Yahia L.H. Effect of surface treatment of NiTi alloy on its corrosion behaviour in Hanks' solution. J Biomed Mater Res 2002, 61(3):339-345.
    • (2002) J Biomed Mater Res , vol.61 , Issue.3 , pp. 339-345
    • Cissé, O.1    Savadogo, O.2    Wu, M.3    Yahia, L.H.4
  • 22
    • 33645926671 scopus 로고    scopus 로고
    • Susceptibility of nitinol to localized corrosion
    • Bruce G.P. Susceptibility of nitinol to localized corrosion. J Biomed Mater Res A 2006, 77A(1):185-191.
    • (2006) J Biomed Mater Res A , vol.77 A , Issue.1 , pp. 185-191
    • Bruce, G.P.1
  • 23
    • 0036431877 scopus 로고    scopus 로고
    • Effect of surface preparation on mechanical properties of a NiTi alloy
    • Miao W.D., Mi X.J., Zhu M., Guo J.F., Kou Y.M. Effect of surface preparation on mechanical properties of a NiTi alloy. Mater Sci Forum 2002, 394-395:173-176.
    • (2002) Mater Sci Forum , pp. 173-176
    • Miao, W.D.1    Mi, X.J.2    Zhu, M.3    Guo, J.F.4    Kou, Y.M.5
  • 25
    • 0021433908 scopus 로고
    • Immunological mechanism of delayed hypersensitivity to nickel compounds
    • Dalmau L.B. Immunological mechanism of delayed hypersensitivity to nickel compounds. Quintessence Int 1984, 15:559-561.
    • (1984) Quintessence Int , vol.15 , pp. 559-561
    • Dalmau, L.B.1
  • 26
    • 0025765960 scopus 로고
    • Molecular mechanisms of nickel carcinogenesis
    • Costa M. Molecular mechanisms of nickel carcinogenesis. Annu Rev Pharmacol Toxicol 1991, 31:321-337.
    • (1991) Annu Rev Pharmacol Toxicol , vol.31 , pp. 321-337
    • Costa, M.1
  • 27
    • 30344459696 scopus 로고    scopus 로고
    • Carcinogenic effect of nickel compounds
    • Lu H., Shi X., Costa M., Huang C. Carcinogenic effect of nickel compounds. Mol Cell Biochem 2005, 279(1):45-67.
    • (2005) Mol Cell Biochem , vol.279 , Issue.1 , pp. 45-67
    • Lu, H.1    Shi, X.2    Costa, M.3    Huang, C.4
  • 28
    • 33748999537 scopus 로고    scopus 로고
    • Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release
    • Clarke B., Carroll W., Rochev Y., Hynes M., Bradley D., Plumley D. Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release. J Biomed Mater Res A 2006, 79A(1):61-70.
    • (2006) J Biomed Mater Res A , vol.79 A , Issue.1 , pp. 61-70
    • Clarke, B.1    Carroll, W.2    Rochev, Y.3    Hynes, M.4    Bradley, D.5    Plumley, D.6
  • 29
    • 0027677960 scopus 로고
    • Oxidation and diffusion processes in nickel-titanium oxide systems
    • Espinós J.P., Fernández A., González-Elipe A.R. Oxidation and diffusion processes in nickel-titanium oxide systems. Surf Sci 1993, 295(3):402-410.
    • (1993) Surf Sci , vol.295 , Issue.3 , pp. 402-410
    • Espinós, J.P.1    Fernández, A.2    González-Elipe, A.R.3
  • 30
    • 34548166247 scopus 로고    scopus 로고
    • Biocompatibility-related surface characteristics of oxidized NiTi
    • Danilov A., Tuukkanen T., Tuukkanen J., Jämsä T. Biocompatibility-related surface characteristics of oxidized NiTi. J Biomed Mater Res A 2007, 82A(4):810-819.
    • (2007) J Biomed Mater Res A , vol.82 A , Issue.4 , pp. 810-819
    • Danilov, A.1    Tuukkanen, T.2    Tuukkanen, J.3    Jämsä, T.4
  • 31
    • 36749111840 scopus 로고
    • Single-crystal elastic constants of the equiatomic NiTi alloy near the martensitic transformation
    • Mercier O., Melton K.N., Gremaud G., Hägi J. Single-crystal elastic constants of the equiatomic NiTi alloy near the martensitic transformation. J Appl Phys 1980, 51(3):1833-1834.
    • (1980) J Appl Phys , vol.51 , Issue.3 , pp. 1833-1834
    • Mercier, O.1    Melton, K.N.2    Gremaud, G.3    Hägi, J.4
  • 32
    • 0035570621 scopus 로고    scopus 로고
    • Physicochemical and biological aspects of Nitinol as a biomaterial
    • Shabalovskaya S.A. Physicochemical and biological aspects of Nitinol as a biomaterial. Int Mater Rev 2001, 46(5):233-250.
    • (2001) Int Mater Rev , vol.46 , Issue.5 , pp. 233-250
    • Shabalovskaya, S.A.1
  • 34
    • 0041467739 scopus 로고    scopus 로고
    • Effect of chemical etching and aging in boiling water on the corrosion resistance of Nitinol wires with black oxide resulting from manufacturing process
    • Shabalovskaya S., Rondelli G., Anderegg J., Simpson B., Budko S. Effect of chemical etching and aging in boiling water on the corrosion resistance of Nitinol wires with black oxide resulting from manufacturing process. J Biomed Mater Res B Appl Biomater 2003, 66(1):331-340.
    • (2003) J Biomed Mater Res B Appl Biomater , vol.66 , Issue.1 , pp. 331-340
    • Shabalovskaya, S.1    Rondelli, G.2    Anderegg, J.3    Simpson, B.4    Budko, S.5
  • 35
    • 16344371208 scopus 로고    scopus 로고
    • Behaviour of human endothelial cells on surface modified NiTi alloy
    • Plant S.D., Grant D.M., Leach L. Behaviour of human endothelial cells on surface modified NiTi alloy. Biomaterials 2005, 26(26):5359-5367.
    • (2005) Biomaterials , vol.26 , Issue.26 , pp. 5359-5367
    • Plant, S.D.1    Grant, D.M.2    Leach, L.3
  • 37
    • 33646356220 scopus 로고    scopus 로고
    • New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility
    • Michiardi A., Aparicio C., Planell J.A., Gil F.J. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility. J Biomed Mater Res B Appl Biomater 2006, 77B(2):249-256.
    • (2006) J Biomed Mater Res B Appl Biomater , vol.77 B , Issue.2 , pp. 249-256
    • Michiardi, A.1    Aparicio, C.2    Planell, J.A.3    Gil, F.J.4
  • 38
    • 11244258494 scopus 로고    scopus 로고
    • The corrosion and nickel release behavior of laser surfacemelted NiTi shape memory alloy in Hanks' solution
    • Cui Z.D., Man H.C., Yang X.J. The corrosion and nickel release behavior of laser surfacemelted NiTi shape memory alloy in Hanks' solution. Surf Coat Technol 2005, 192(2-3):347-353.
    • (2005) Surf Coat Technol , vol.192 , Issue.2-3 , pp. 347-353
    • Cui, Z.D.1    Man, H.C.2    Yang, X.J.3
  • 41
    • 33751067289 scopus 로고    scopus 로고
    • Structural-phase condition, unelastic and plastic behavior and nanohardness of the TiNi surface layers modified by an ion- and electron irradiation
    • Meisner L.L., Lotkov A.I., Sivokha V.P., Rotshtein V.P., Barmina E.G., Girjakova Y.L. Structural-phase condition, unelastic and plastic behavior and nanohardness of the TiNi surface layers modified by an ion- and electron irradiation. Mater Sci Eng A 2006, 438-440:558-562.
    • (2006) Mater Sci Eng A , pp. 558-562
    • Meisner, L.L.1    Lotkov, A.I.2    Sivokha, V.P.3    Rotshtein, V.P.4    Barmina, E.G.5    Girjakova, Y.L.6
  • 42
    • 0027168664 scopus 로고
    • 2-treated titanium surfaces in contact with blood plasma and a simulated body fluid
    • 2-treated titanium surfaces in contact with blood plasma and a simulated body fluid. Clin Mater 1993, 12(3):141-148.
    • (1993) Clin Mater , vol.12 , Issue.3 , pp. 141-148
    • Wälivaara, B.1    Lundström, I.2    Tengvall, P.3
  • 43
    • 0028107940 scopus 로고
    • Titanium with different oxides: in vitro studies of protein adsorption and contact activation
    • Wälivaara B., Aronsson B.-O., Rodahl M., Lausmaa J., Tengvall P. Titanium with different oxides: in vitro studies of protein adsorption and contact activation. Biomaterials 1994, 15(10):827-834.
    • (1994) Biomaterials , vol.15 , Issue.10 , pp. 827-834
    • Wälivaara, B.1    Aronsson, B.-O.2    Rodahl, M.3    Lausmaa, J.4    Tengvall, P.5
  • 44
    • 84956040351 scopus 로고
    • Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants
    • Shabalovskaya S.A., Anderegg J.W. Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants. J Vac Sci Technol A 1995, 13(5):2624-2632.
    • (1995) J Vac Sci Technol A , vol.13 , Issue.5 , pp. 2624-2632
    • Shabalovskaya, S.A.1    Anderegg, J.W.2
  • 45
    • 0038462111 scopus 로고    scopus 로고
    • Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets
    • Choi J., Bogdanski D., Köller M., Esenwein S.A., Müller D., Muhr G., Epple M. Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets. Biomaterials 2003, 24:3689-3696.
    • (2003) Biomaterials , vol.24 , pp. 3689-3696
    • Choi, J.1    Bogdanski, D.2    Köller, M.3    Esenwein, S.A.4    Müller, D.5    Muhr, G.6    Epple, M.7
  • 46
    • 2342433335 scopus 로고    scopus 로고
    • Inhibition of PMN apoptosis after adherence to dip-coated calcium phosphate surfaces on a NiTi shape memory alloy
    • Bogdanski D., Esenwein S.A., Prymak O., Epple M., Muhr G., Köller M. Inhibition of PMN apoptosis after adherence to dip-coated calcium phosphate surfaces on a NiTi shape memory alloy. Biomaterials 2004, 25(19):4627-4632.
    • (2004) Biomaterials , vol.25 , Issue.19 , pp. 4627-4632
    • Bogdanski, D.1    Esenwein, S.A.2    Prymak, O.3    Epple, M.4    Muhr, G.5    Köller, M.6
  • 47
    • 84903921669 scopus 로고    scopus 로고
    • ASTM F86-04 Standard practice for surface preparation and marking of metallic surgical implants
    • Astm International. ASTM, Philadelphia
    • Astm International ASTM F86-04 Standard practice for surface preparation and marking of metallic surgical implants. Annual book of ASTM standards 1996, ASTM, Philadelphia.
    • (1996) Annual book of ASTM standards
  • 48
    • 26844515262 scopus 로고    scopus 로고
    • Reduced thrombogenicity of nitinol stents - in vitro evaluation of different surface modifications and coatings
    • Tepe G., Schmehl J., Wendel H.P., Schaffner S., Heller S., Gianotti M., Claussen C.D., Duda S.H. Reduced thrombogenicity of nitinol stents - in vitro evaluation of different surface modifications and coatings. Biomaterials 2006, 27(4):643-650.
    • (2006) Biomaterials , vol.27 , Issue.4 , pp. 643-650
    • Tepe, G.1    Schmehl, J.2    Wendel, H.P.3    Schaffner, S.4    Heller, S.5    Gianotti, M.6    Claussen, C.D.7    Duda, S.H.8
  • 51
    • 33645119700 scopus 로고    scopus 로고
    • Plasma immersion ion implanted nitinol surface with depressed nickel concentration for implants in blood
    • Maitz M.F., Shevchenko N. Plasma immersion ion implanted nitinol surface with depressed nickel concentration for implants in blood. J Biomed Mater Res A 2005, 76A(2):356-365.
    • (2005) J Biomed Mater Res A , vol.76 A , Issue.2 , pp. 356-365
    • Maitz, M.F.1    Shevchenko, N.2
  • 54
    • 0242666828 scopus 로고    scopus 로고
    • Surface modification of TiNi alloy through tantalum immersion ion implantation
    • Cheng Y., Wei C., Gan K.Y., Zhao L.C. Surface modification of TiNi alloy through tantalum immersion ion implantation. Surf Coat Technol 2004, 176(2):261-265.
    • (2004) Surf Coat Technol , vol.176 , Issue.2 , pp. 261-265
    • Cheng, Y.1    Wei, C.2    Gan, K.Y.3    Zhao, L.C.4
  • 55
    • 0035803946 scopus 로고    scopus 로고
    • TiN coating improves the corrosion behavior of superelastic NiTi surgical alloy
    • Starosvetsky D., Gotman I. TiN coating improves the corrosion behavior of superelastic NiTi surgical alloy. Surf Coat Technol 2001, 148:268-276.
    • (2001) Surf Coat Technol , vol.148 , pp. 268-276
    • Starosvetsky, D.1    Gotman, I.2
  • 56
    • 0034087518 scopus 로고    scopus 로고
    • Titanium nitride coatings on surgical titanium alloys produced by a powder immersion reaction assisted coating method: residual stresses and fretting behavior
    • Shenhar A., Gotman I., Radin S., Ducheyne P., Gutmanas E.Y. Titanium nitride coatings on surgical titanium alloys produced by a powder immersion reaction assisted coating method: residual stresses and fretting behavior. Surf Coat Technol 2000, 126:210-218.
    • (2000) Surf Coat Technol , vol.126 , pp. 210-218
    • Shenhar, A.1    Gotman, I.2    Radin, S.3    Ducheyne, P.4    Gutmanas, E.Y.5
  • 57
    • 0028704565 scopus 로고
    • Effects of titanium nitride coatings on surface and corrosion characteristics of Ni-Ti alloy
    • Endo K., Sachdeva R., Araki Y., Ohno H. Effects of titanium nitride coatings on surface and corrosion characteristics of Ni-Ti alloy. Dent Mater J 1994, 13(2):228-239.
    • (1994) Dent Mater J , vol.13 , Issue.2 , pp. 228-239
    • Endo, K.1    Sachdeva, R.2    Araki, Y.3    Ohno, H.4
  • 58
    • 34447325630 scopus 로고    scopus 로고
    • Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages
    • Liu X.M., Wu S.L., Chan Y.L., Chu P.K., Chung C.Y., Chu C.L., Yeung K.W.K., Lu W.W., Cheung K.M.C., Luk K.D.K. Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages. J Biomed Mater Res A 2007, 82A(2):469-478.
    • (2007) J Biomed Mater Res A , vol.82 A , Issue.2 , pp. 469-478
    • Liu, X.M.1    Wu, S.L.2    Chan, Y.L.3    Chu, P.K.4    Chung, C.Y.5    Chu, C.L.6    Yeung, K.W.K.7    Lu, W.W.8    Cheung, K.M.C.9    Luk, K.D.K.10
  • 59
    • 4344574094 scopus 로고    scopus 로고
    • Studies of surface modified NiTi alloy
    • Shevchenko N., Pham M.-T., Maitz M.F. Studies of surface modified NiTi alloy. Appl Surf Sci 2004, 235(1-2):126-131.
    • (2004) Appl Surf Sci , vol.235 , Issue.1-2 , pp. 126-131
    • Shevchenko, N.1    Pham, M.-T.2    Maitz, M.F.3
  • 60
    • 33747343183 scopus 로고    scopus 로고
    • 2/Ar gas flow ratio on the deposition of TiN/Ti coatings on NiTi shape memory alloy by PIIID
    • 2/Ar gas flow ratio on the deposition of TiN/Ti coatings on NiTi shape memory alloy by PIIID. Mater Lett 2006, 60(17-18):2243-2247.
    • (2006) Mater Lett , vol.60 , Issue.17-18 , pp. 2243-2247
    • Cheng, Y.1    Zheng, Y.F.2
  • 61
    • 0027590280 scopus 로고
    • Sol-gel processing of titaniumcontaining thin coatings. Part I. Preparation and structure
    • Samuneva B., Kozhukharov V., Trapalis C., Kranold R. Sol-gel processing of titaniumcontaining thin coatings. Part I. Preparation and structure. J Mater Sci 1993, 28(9):2353-2360.
    • (1993) J Mater Sci , vol.28 , Issue.9 , pp. 2353-2360
    • Samuneva, B.1    Kozhukharov, V.2    Trapalis, C.3    Kranold, R.4
  • 62
    • 0038636424 scopus 로고    scopus 로고
    • 2 film on NiTi surgical alloy for biocompatibility improvement
    • 2 film on NiTi surgical alloy for biocompatibility improvement. Thin Solid Films 2003, 429(1-2):225-230.
    • (2003) Thin Solid Films , vol.429 , Issue.1-2 , pp. 225-230
    • Liu, J.-X.1    Yang, D.-Z.2    Shi, F.3    Cai, Y.-J.4
  • 63
    • 0019317954 scopus 로고
    • Amorphous and crystalline dip coatings obtained from organometallic solutions: Procedures, chemical processes and products
    • Dislich H., Hussmann E. Amorphous and crystalline dip coatings obtained from organometallic solutions: Procedures, chemical processes and products. Thin Solid Films 1981, 77(1-3):129-140.
    • (1981) Thin Solid Films , vol.77 , Issue.1-3 , pp. 129-140
    • Dislich, H.1    Hussmann, E.2
  • 64
    • 0033973739 scopus 로고    scopus 로고
    • Titanium dioxide ceramics control the differentiated phenotype of cardiac muscle cells in culture
    • Polonchuk L., Elbel J., Eckert L., Blum J., Wintermantel E., Eppenberger H.M. Titanium dioxide ceramics control the differentiated phenotype of cardiac muscle cells in culture. Biomaterials 2000, 21(6):539-550.
    • (2000) Biomaterials , vol.21 , Issue.6 , pp. 539-550
    • Polonchuk, L.1    Elbel, J.2    Eckert, L.3    Blum, J.4    Wintermantel, E.5    Eppenberger, H.M.6
  • 65
    • 0032487121 scopus 로고    scopus 로고
    • Calcium phosphate induction by sol-gel-derived titania coatings on titanium substrates in vitro
    • Peltola T., Patsi M., Rahiala H., Kangasniemi I., Yli-Urpo A. Calcium phosphate induction by sol-gel-derived titania coatings on titanium substrates in vitro. J Biomed Mater Res 1998, 41(3):504-510.
    • (1998) J Biomed Mater Res , vol.41 , Issue.3 , pp. 504-510
    • Peltola, T.1    Patsi, M.2    Rahiala, H.3    Kangasniemi, I.4    Yli-Urpo, A.5
  • 66
    • 12344298672 scopus 로고    scopus 로고
    • Surface modification of titanium, titanium alloys, and related materials for biomedical applications
    • Liu X., Chu P.K., Ding C. Surface modification of titanium, titanium alloys, and related materials for biomedical applications. Mater Sci Eng R 2004, 47(3-4):49-121.
    • (2004) Mater Sci Eng R , vol.47 , Issue.3-4 , pp. 49-121
    • Liu, X.1    Chu, P.K.2    Ding, C.3
  • 68
    • 0027592463 scopus 로고
    • Porcelain bonding on Ti: Its dependence on surface roughness, firing time and vacuum level
    • Hautaniemi J.A., Juhanoja J.T., Herø H. Porcelain bonding on Ti: Its dependence on surface roughness, firing time and vacuum level. Surf Interface Anal 1993, 20(5):421-426.
    • (1993) Surf Interface Anal , vol.20 , Issue.5 , pp. 421-426
    • Hautaniemi, J.A.1    Juhanoja, J.T.2    Herø, H.3
  • 69
    • 0030298049 scopus 로고    scopus 로고
    • Preparation of bioactive Ti and its alloys via simple chemical surface treatment
    • Kim H.M., Miyaji F., Kokubo T., Nakamura T. Preparation of bioactive Ti and its alloys via simple chemical surface treatment. J Biomed Mater Res 1996, 32(3):409-417.
    • (1996) J Biomed Mater Res , vol.32 , Issue.3 , pp. 409-417
    • Kim, H.M.1    Miyaji, F.2    Kokubo, T.3    Nakamura, T.4
  • 70
    • 0028069746 scopus 로고
    • The role of hydrated silica, titania, and alumina in inducing apatite on implants
    • Li P., Ohtsuki C., Kokubo T., Nakanishi K., Soga N., De Groot K. The role of hydrated silica, titania, and alumina in inducing apatite on implants. J Biomed Mater Res 1994, 28(1):7-15.
    • (1994) J Biomed Mater Res , vol.28 , Issue.1 , pp. 7-15
    • Li, P.1    Ohtsuki, C.2    Kokubo, T.3    Nakanishi, K.4    Soga, N.5    De Groot, K.6
  • 71
    • 23244448563 scopus 로고    scopus 로고
    • Biomimetic deposition of apatite coating on surface-modified NiTi alloy
    • Gu Y.W., Tay B.Y., Lim C.S., Yong M.S. Biomimetic deposition of apatite coating on surface-modified NiTi alloy. Biomaterials 2005, 26(34):6916-6923.
    • (2005) Biomaterials , vol.26 , Issue.34 , pp. 6916-6923
    • Gu, Y.W.1    Tay, B.Y.2    Lim, C.S.3    Yong, M.S.4
  • 73
    • 34447498812 scopus 로고    scopus 로고
    • Enhancement of surface properties of biomaterials using plasma-based technologies
    • Chu P.K. Enhancement of surface properties of biomaterials using plasma-based technologies. Surf Coat Technol 2007, 201(19-20):8076-8082.
    • (2007) Surf Coat Technol , vol.201 , Issue.19-20 , pp. 8076-8082
    • Chu, P.K.1
  • 74
    • 33748943616 scopus 로고    scopus 로고
    • Effect of diamond-like carbon (DLC) on the properties of the NiTi alloys
    • Sui J.H., Cai W. Effect of diamond-like carbon (DLC) on the properties of the NiTi alloys. Diam Rel Mater 2006, 15(10):1720-1726.
    • (2006) Diam Rel Mater , vol.15 , Issue.10 , pp. 1720-1726
    • Sui, J.H.1    Cai, W.2
  • 75
    • 33846500137 scopus 로고    scopus 로고
    • Plasma surface treatment of artificial orthopedic and cardiovascular biomaterials
    • Chu P.K. Plasma surface treatment of artificial orthopedic and cardiovascular biomaterials. Surf Coat Techn 2007, 201(9-11):5601-5606.
    • (2007) Surf Coat Techn , vol.201 , Issue.9-11 , pp. 5601-5606
    • Chu, P.K.1
  • 81
    • 3042850877 scopus 로고    scopus 로고
    • Hemocompatibility of nitrogen-doped, hydrogen-free diamond-like carbon prepared by nitrogen plasma immersion ion implantation-deposition
    • Kwok S.C.H., Yang P., Wang J., Liu X., Chu P.K. Hemocompatibility of nitrogen-doped, hydrogen-free diamond-like carbon prepared by nitrogen plasma immersion ion implantation-deposition. J Biomed Mater Res 2004, 70A(1):107-114.
    • (2004) J Biomed Mater Res , vol.70 A , Issue.1 , pp. 107-114
    • Kwok, S.C.H.1    Yang, P.2    Wang, J.3    Liu, X.4    Chu, P.K.5
  • 84
    • 4243386780 scopus 로고    scopus 로고
    • Growth mechanism and cross-sectional structure of tetrahedral amorphous carbon thin films
    • Davis C.A., Amaratunga G.A.J., Knowles K.M. Growth mechanism and cross-sectional structure of tetrahedral amorphous carbon thin films. Phys Rev Lett 1998, 80(15):3280.
    • (1998) Phys Rev Lett , vol.80 , Issue.15 , pp. 3280
    • Davis, C.A.1    Amaratunga, G.A.J.2    Knowles, K.M.3
  • 85
    • 17144445444 scopus 로고    scopus 로고
    • Spectroscopic ellipsometry investigation of amorphous carbon films with different sp3 content: relation with protein adsorption
    • Vinnichenko M., Gago R., Huang N., Leng Y.X., Sun H., Kreissig U., Kulish M.P., Maitz M.F. Spectroscopic ellipsometry investigation of amorphous carbon films with different sp3 content: relation with protein adsorption. Thin Solid Films 2004, 455-456C:530-534.
    • (2004) Thin Solid Films , pp. 530-534
    • Vinnichenko, M.1    Gago, R.2    Huang, N.3    Leng, Y.X.4    Sun, H.5    Kreissig, U.6    Kulish, M.P.7    Maitz, M.F.8
  • 86
    • 0030332536 scopus 로고    scopus 로고
    • Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating
    • Villermaux F., Tabrizian M., Yahia L., Czeremuszkin G., Piron D.L. Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating. Biomed Mater Eng 1996, 6(4):241-254.
    • (1996) Biomed Mater Eng , vol.6 , Issue.4 , pp. 241-254
    • Villermaux, F.1    Tabrizian, M.2    Yahia, L.3    Czeremuszkin, G.4    Piron, D.L.5
  • 87
    • 0033939780 scopus 로고    scopus 로고
    • DC plasma-polymerized hexamethyldisilazane coatings of an equiatomic TiNi shape memory alloy
    • Yang M.-R., Wu S.K. DC plasma-polymerized hexamethyldisilazane coatings of an equiatomic TiNi shape memory alloy. Surf Coat Technol 2000, 127(2-3):273-280.
    • (2000) Surf Coat Technol , vol.127 , Issue.2-3 , pp. 273-280
    • Yang, M.-R.1    Wu, S.K.2
  • 89
    • 31544474052 scopus 로고    scopus 로고
    • Structural evaluation of radially expandable cardiovascular stents encased in a polyurethane film
    • Trigwell S., De S., Sharma R., Mazumder M.K., Mehta J.L. Structural evaluation of radially expandable cardiovascular stents encased in a polyurethane film. J Biomed Mater Res B Appl Biomater 2006, 76B(2):241-250.
    • (2006) J Biomed Mater Res B Appl Biomater , vol.76 B , Issue.2 , pp. 241-250
    • Trigwell, S.1    De, S.2    Sharma, R.3    Mazumder, M.K.4    Mehta, J.L.5
  • 92
    • 0028765988 scopus 로고
    • Vibrational spectra of some diisocyanates in the liquid state or on EPDM-40 rubber surface
    • Kondyurin A., Klyachkin Y. Vibrational spectra of some diisocyanates in the liquid state or on EPDM-40 rubber surface. J Appl Polym Sci 1994, 54(10):1385-1393.
    • (1994) J Appl Polym Sci , vol.54 , Issue.10 , pp. 1385-1393
    • Kondyurin, A.1    Klyachkin, Y.2
  • 93
    • 9944224238 scopus 로고    scopus 로고
    • Surface properties of bio-implant Nitinol modified by ECR cold plasma
    • Yang J., Wang J., Tong S. Surface properties of bio-implant Nitinol modified by ECR cold plasma. Mater Sci Technol 2004, 20(11):1427-1430.
    • (2004) Mater Sci Technol , vol.20 , Issue.11 , pp. 1427-1430
    • Yang, J.1    Wang, J.2    Tong, S.3
  • 94
    • 34249658951 scopus 로고    scopus 로고
    • Plasma-deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition
    • Cao L., Chang M., Lee C.-Y., Castner D.G., Sukavaneshvar S., Ratner B.D., Horbett T.A. Plasma-deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition. J Biomed Mater Res A 2007, 81A(4):827-837.
    • (2007) J Biomed Mater Res A , vol.81 A , Issue.4 , pp. 827-837
    • Cao, L.1    Chang, M.2    Lee, C.-Y.3    Castner, D.G.4    Sukavaneshvar, S.5    Ratner, B.D.6    Horbett, T.A.7
  • 95
    • 0032928387 scopus 로고    scopus 로고
    • Polyethylene terephthalate and polyurethane coatings for endovascular stents: preliminary results in canine experimental arteriovenous fistulas
    • Schellhammer F., Walter M., Berlis A., Bloss H.G., Wellens E., Schumacher M. Polyethylene terephthalate and polyurethane coatings for endovascular stents: preliminary results in canine experimental arteriovenous fistulas. Radiology 1999, 211(1):169-175.
    • (1999) Radiology , vol.211 , Issue.1 , pp. 169-175
    • Schellhammer, F.1    Walter, M.2    Berlis, A.3    Bloss, H.G.4    Wellens, E.5    Schumacher, M.6
  • 97
    • 34547741083 scopus 로고    scopus 로고
    • Current strategies towards hemocompatible coatings
    • Werner C., Maitz M.F., Sperling C. Current strategies towards hemocompatible coatings. J Mater Chem 2007, 17:3376-3384.
    • (2007) J Mater Chem , vol.17 , pp. 3376-3384
    • Werner, C.1    Maitz, M.F.2    Sperling, C.3
  • 98
    • 33644843665 scopus 로고    scopus 로고
    • Biodegradable membrane-covered stent from chitosan-based polymers
    • Thierry B., Merhi Y., Silver J., Tabrizian M. Biodegradable membrane-covered stent from chitosan-based polymers. J Biomed Mater Res A 2005, 75A(3):556-566.
    • (2005) J Biomed Mater Res A , vol.75 A , Issue.3 , pp. 556-566
    • Thierry, B.1    Merhi, Y.2    Silver, J.3    Tabrizian, M.4
  • 99
    • 2542629648 scopus 로고    scopus 로고
    • Anticoagulant and antiplatelet agents: their clinical and device application(s) together with usages to engineer surfaces
    • Kidane A.G., Salacinski H., Tiwari A., Bruckdorfer K.R., Seifalian A.M. Anticoagulant and antiplatelet agents: their clinical and device application(s) together with usages to engineer surfaces. Biomacromolecules 2004, 5(3):798-813.
    • (2004) Biomacromolecules , vol.5 , Issue.3 , pp. 798-813
    • Kidane, A.G.1    Salacinski, H.2    Tiwari, A.3    Bruckdorfer, K.R.4    Seifalian, A.M.5
  • 100
    • 0347384110 scopus 로고    scopus 로고
    • Optimal heparin surface concentration and antithrombin binding capacity as evaluated with human nonanticoagulated blood in vitro
    • Andersson J., Sanchez J., Ekdahl K.N., Elgue G., Nilsson B., Larsson R. Optimal heparin surface concentration and antithrombin binding capacity as evaluated with human nonanticoagulated blood in vitro. J Biomed Mater Res A 2003, 67(2):458-466.
    • (2003) J Biomed Mater Res A , vol.67 , Issue.2 , pp. 458-466
    • Andersson, J.1    Sanchez, J.2    Ekdahl, K.N.3    Elgue, G.4    Nilsson, B.5    Larsson, R.6
  • 101
    • 33744537149 scopus 로고    scopus 로고
    • Mechanisms of controlled drug release from drug-eluting stents
    • Acharya G., Park K. Mechanisms of controlled drug release from drug-eluting stents. Adv Drug Deliv Rev 2006, 58(3):387-401.
    • (2006) Adv Drug Deliv Rev , vol.58 , Issue.3 , pp. 387-401
    • Acharya, G.1    Park, K.2
  • 104
    • 0038711003 scopus 로고    scopus 로고
    • New frontiers in cardiology: drug-eluting stents: Part I
    • Sousa J.E., Serruys P.W., Costa M.A. New frontiers in cardiology: drug-eluting stents: Part I. Circulation 2003, 107(17):2274-2279.
    • (2003) Circulation , vol.107 , Issue.17 , pp. 2274-2279
    • Sousa, J.E.1    Serruys, P.W.2    Costa, M.A.3
  • 105
    • 0038711003 scopus 로고    scopus 로고
    • New frontiers in cardiology: drug-eluting stents: Part II
    • Sousa J.E., Serruys P.W., Costa M.A. New frontiers in cardiology: drug-eluting stents: Part II. Circulation 2003, 107(18):2383-2389.
    • (2003) Circulation , vol.107 , Issue.18 , pp. 2383-2389
    • Sousa, J.E.1    Serruys, P.W.2    Costa, M.A.3
  • 108
    • 0034666762 scopus 로고    scopus 로고
    • Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
    • Thierry B., Tabrizian M., Trepanier C., Savadogo O., Yahia L. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy. J Biomed Mater Res 2000, 51(4):685-693.
    • (2000) J Biomed Mater Res , vol.51 , Issue.4 , pp. 685-693
    • Thierry, B.1    Tabrizian, M.2    Trepanier, C.3    Savadogo, O.4    Yahia, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.