-
1
-
-
38049094438
-
Shape memory alloys - medical applications
-
Anson T. Shape memory alloys - medical applications. Mater World 1999, 7(12):745-747.
-
(1999)
Mater World
, vol.7
, Issue.12
, pp. 745-747
-
-
Anson, T.1
-
2
-
-
0039171080
-
An overview of nitinol medical applications
-
Duerig T., Pelton A., Stöckel D. An overview of nitinol medical applications. Mater Sci Eng A 1999, 273-275:149-160.
-
(1999)
Mater Sci Eng A
, pp. 149-160
-
-
Duerig, T.1
Pelton, A.2
Stöckel, D.3
-
3
-
-
0345269973
-
Nickel release after implantation of the Amplatzer occluder
-
Ries M.W., Kampmann C., Rupprecht H.-J., Hintereder G., Hafner G., Meyer J. Nickel release after implantation of the Amplatzer occluder. Am Heart J 2003, 145:737-741.
-
(2003)
Am Heart J
, vol.145
, pp. 737-741
-
-
Ries, M.W.1
Kampmann, C.2
Rupprecht, H.-J.3
Hintereder, G.4
Hafner, G.5
Meyer, J.6
-
4
-
-
0142101894
-
Porous titanium-nickel for intervertebral fusion in a sheep model: Part 2. Surface analysis and nickel release assessment
-
Assad M., Chernyshov A.V., Jarzem P., Leroux M.A., Coillard C., Charette S., Rivard C.H. Porous titanium-nickel for intervertebral fusion in a sheep model: Part 2. Surface analysis and nickel release assessment. J Biomed Mater Res 2003, 64B(2):121-129.
-
(2003)
J Biomed Mater Res
, vol.64 B
, Issue.2
, pp. 121-129
-
-
Assad, M.1
Chernyshov, A.V.2
Jarzem, P.3
Leroux, M.A.4
Coillard, C.5
Charette, S.6
Rivard, C.H.7
-
5
-
-
0034911604
-
Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure?
-
Heintz C., Riepe G., Birken L., Kaiser E., Chakfe N., Morlock M., Delling G., Imig H. Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure?. J Endovasc Ther 2001, 8(3):248-253.
-
(2001)
J Endovasc Ther
, vol.8
, Issue.3
, pp. 248-253
-
-
Heintz, C.1
Riepe, G.2
Birken, L.3
Kaiser, E.4
Chakfe, N.5
Morlock, M.6
Delling, G.7
Imig, H.8
-
6
-
-
0034333616
-
The cytotoxicity of corrosion products of nitinol stent wire on cultured smooth muscle cells
-
Shih C.-C., Lin S.-J., Chen Y.-L., Su Y.-Y., Lai S.-T., Wu G.J., Kwok C.-F., Chung K.-H. The cytotoxicity of corrosion products of nitinol stent wire on cultured smooth muscle cells. J Biomed Mater Res 2000, 52(2):395-403.
-
(2000)
J Biomed Mater Res
, vol.52
, Issue.2
, pp. 395-403
-
-
Shih, C.-C.1
Lin, S.-J.2
Chen, Y.-L.3
Su, Y.-Y.4
Lai, S.-T.5
Wu, G.J.6
Kwok, C.-F.7
Chung, K.-H.8
-
7
-
-
0034774586
-
Growth inhibition of cultured smooth muscle cells by corrosion products of 316L stainless-steel wire
-
Shih C.C., Shih C.M., Chen Y.L., Su Y.Y., Shih J.S., Kwok C.F., Lin S.J. Growth inhibition of cultured smooth muscle cells by corrosion products of 316L stainless-steel wire. J Biomed Mater Res 2001, 57(2):200-207.
-
(2001)
J Biomed Mater Res
, vol.57
, Issue.2
, pp. 200-207
-
-
Shih, C.C.1
Shih, C.M.2
Chen, Y.L.3
Su, Y.Y.4
Shih, J.S.5
Kwok, C.F.6
Lin, S.J.7
-
8
-
-
0034801325
-
Relating nickel-induced tissue inflammation to nickel release in vivo
-
Wataha J.C., O'Dell N.L., Singh B.B., Ghazi M., Whitford G.M., Lockwood P.E. Relating nickel-induced tissue inflammation to nickel release in vivo. J Biomed Mater Res 2001, 58(5):537-544.
-
(2001)
J Biomed Mater Res
, vol.58
, Issue.5
, pp. 537-544
-
-
Wataha, J.C.1
O'Dell, N.L.2
Singh, B.B.3
Ghazi, M.4
Whitford, G.M.5
Lockwood, P.E.6
-
9
-
-
0034333624
-
Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide
-
Shih C.-C., Lin S.-J., Chung K.-H., Chen Y.-L., Su Y.-Y. Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide. J Biomed Mater Res 2000, 52(2):323-332.
-
(2000)
J Biomed Mater Res
, vol.52
, Issue.2
, pp. 323-332
-
-
Shih, C.-C.1
Lin, S.-J.2
Chung, K.-H.3
Chen, Y.-L.4
Su, Y.-Y.5
-
11
-
-
0346244109
-
Surface conditions of Nitinol wires, tubing, and as-cast alloys. The effect of chemical etching, aging in boiling water, and heat treatment
-
Shabalovskaya S.A., Anderegg J., Laab F., Thiel P.A., Rondelli G. Surface conditions of Nitinol wires, tubing, and as-cast alloys. The effect of chemical etching, aging in boiling water, and heat treatment. J Biomed Mater Res B Appl Biomater 2003, 65(1):193-203.
-
(2003)
J Biomed Mater Res B Appl Biomater
, vol.65
, Issue.1
, pp. 193-203
-
-
Shabalovskaya, S.A.1
Anderegg, J.2
Laab, F.3
Thiel, P.A.4
Rondelli, G.5
-
12
-
-
0031214566
-
Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy
-
Wever D.J., Veldhuizen A.G., Sanders M.M., Schakenraad J.M., Van Horn J.R. Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy. Biomaterials 1997, 18(16):1115-1120.
-
(1997)
Biomaterials
, vol.18
, Issue.16
, pp. 1115-1120
-
-
Wever, D.J.1
Veldhuizen, A.G.2
Sanders, M.M.3
Schakenraad, J.M.4
Van Horn, J.R.5
-
13
-
-
34547888787
-
The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation
-
Peitsch T., Klocke A., Kahl-Nieke B., Prymak O., Epple M. The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation. J Biomed Mater Res A 2007, 82A(3):731-739.
-
(2007)
J Biomed Mater Res A
, vol.82 A
, Issue.3
, pp. 731-739
-
-
Peitsch, T.1
Klocke, A.2
Kahl-Nieke, B.3
Prymak, O.4
Epple, M.5
-
15
-
-
0032090001
-
Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications
-
Trigwell S., Hayden R.D., Nelson K.F., Selvaduray G. Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications. Surf Interface Anal 1998, 26(7):483-489.
-
(1998)
Surf Interface Anal
, vol.26
, Issue.7
, pp. 483-489
-
-
Trigwell, S.1
Hayden, R.D.2
Nelson, K.F.3
Selvaduray, G.4
-
16
-
-
2442440803
-
Comparative corrosion performance of black oxide, sandblasted, and fine-drawn nitinol wires in potentiodynamic and potentiostatic tests: Effects of chemical etching and electropolishing
-
Shabalovskaya S., Rondelli G., Anderegg J., Xiong J.P., Wu M. Comparative corrosion performance of black oxide, sandblasted, and fine-drawn nitinol wires in potentiodynamic and potentiostatic tests: Effects of chemical etching and electropolishing. J Biomed Mater Res 2004, 69B(2):223-231.
-
(2004)
J Biomed Mater Res
, vol.69 B
, Issue.2
, pp. 223-231
-
-
Shabalovskaya, S.1
Rondelli, G.2
Anderegg, J.3
Xiong, J.P.4
Wu, M.5
-
17
-
-
0036013926
-
On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility
-
Es-Souni M., Es-Souni M., Fischer-Brandies H. On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility. Biomaterials 2002, 23(14):2887-2894.
-
(2002)
Biomaterials
, vol.23
, Issue.14
, pp. 2887-2894
-
-
Es-Souni, M.1
Es-Souni, M.2
Fischer-Brandies, H.3
-
18
-
-
0035691819
-
Surface conditioning of nickel-titanium alloy stents for improving biocompatibility
-
Zhao H., Van Humbeeck J., De Scheerder I. Surface conditioning of nickel-titanium alloy stents for improving biocompatibility. Surf Eng 2001, 17(6):451-458.
-
(2001)
Surf Eng
, vol.17
, Issue.6
, pp. 451-458
-
-
Zhao, H.1
Van Humbeeck, J.2
De Scheerder, I.3
-
19
-
-
0036179018
-
Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
-
Shabalovskaya S.A. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material. Biomed Mater Eng 2002, 12(1):69-109.
-
(2002)
Biomed Mater Eng
, vol.12
, Issue.1
, pp. 69-109
-
-
Shabalovskaya, S.A.1
-
20
-
-
0033990205
-
Effects of sterilization processes on NiTi alloy: surface characterization
-
Thierry B., Tabrizian M., Savadogo O., Yahia L. Effects of sterilization processes on NiTi alloy: surface characterization. J Biomed Mater Res 2000, 49(1):88-98.
-
(2000)
J Biomed Mater Res
, vol.49
, Issue.1
, pp. 88-98
-
-
Thierry, B.1
Tabrizian, M.2
Savadogo, O.3
Yahia, L.4
-
21
-
-
0037026414
-
Effect of surface treatment of NiTi alloy on its corrosion behaviour in Hanks' solution
-
Cissé O., Savadogo O., Wu M., Yahia L.H. Effect of surface treatment of NiTi alloy on its corrosion behaviour in Hanks' solution. J Biomed Mater Res 2002, 61(3):339-345.
-
(2002)
J Biomed Mater Res
, vol.61
, Issue.3
, pp. 339-345
-
-
Cissé, O.1
Savadogo, O.2
Wu, M.3
Yahia, L.H.4
-
22
-
-
33645926671
-
Susceptibility of nitinol to localized corrosion
-
Bruce G.P. Susceptibility of nitinol to localized corrosion. J Biomed Mater Res A 2006, 77A(1):185-191.
-
(2006)
J Biomed Mater Res A
, vol.77 A
, Issue.1
, pp. 185-191
-
-
Bruce, G.P.1
-
23
-
-
0036431877
-
Effect of surface preparation on mechanical properties of a NiTi alloy
-
Miao W.D., Mi X.J., Zhu M., Guo J.F., Kou Y.M. Effect of surface preparation on mechanical properties of a NiTi alloy. Mater Sci Forum 2002, 394-395:173-176.
-
(2002)
Mater Sci Forum
, pp. 173-176
-
-
Miao, W.D.1
Mi, X.J.2
Zhu, M.3
Guo, J.F.4
Kou, Y.M.5
-
24
-
-
0023095351
-
Prater Epidemiology of nickel allergy
-
Schubert H., Berova N., Hegyi E., Jirasek L., Kohanka V., Korossy S., Michailov P., Nebenführer L., Prater Epidemiology of nickel allergy. Contact Derm 1987, 16:122-128.
-
(1987)
Contact Derm
, vol.16
, pp. 122-128
-
-
Schubert, H.1
Berova, N.2
Hegyi, E.3
Jirasek, L.4
Kohanka, V.5
Korossy, S.6
Michailov, P.7
Nebenführer, L.8
-
25
-
-
0021433908
-
Immunological mechanism of delayed hypersensitivity to nickel compounds
-
Dalmau L.B. Immunological mechanism of delayed hypersensitivity to nickel compounds. Quintessence Int 1984, 15:559-561.
-
(1984)
Quintessence Int
, vol.15
, pp. 559-561
-
-
Dalmau, L.B.1
-
26
-
-
0025765960
-
Molecular mechanisms of nickel carcinogenesis
-
Costa M. Molecular mechanisms of nickel carcinogenesis. Annu Rev Pharmacol Toxicol 1991, 31:321-337.
-
(1991)
Annu Rev Pharmacol Toxicol
, vol.31
, pp. 321-337
-
-
Costa, M.1
-
27
-
-
30344459696
-
Carcinogenic effect of nickel compounds
-
Lu H., Shi X., Costa M., Huang C. Carcinogenic effect of nickel compounds. Mol Cell Biochem 2005, 279(1):45-67.
-
(2005)
Mol Cell Biochem
, vol.279
, Issue.1
, pp. 45-67
-
-
Lu, H.1
Shi, X.2
Costa, M.3
Huang, C.4
-
28
-
-
33748999537
-
Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release
-
Clarke B., Carroll W., Rochev Y., Hynes M., Bradley D., Plumley D. Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release. J Biomed Mater Res A 2006, 79A(1):61-70.
-
(2006)
J Biomed Mater Res A
, vol.79 A
, Issue.1
, pp. 61-70
-
-
Clarke, B.1
Carroll, W.2
Rochev, Y.3
Hynes, M.4
Bradley, D.5
Plumley, D.6
-
29
-
-
0027677960
-
Oxidation and diffusion processes in nickel-titanium oxide systems
-
Espinós J.P., Fernández A., González-Elipe A.R. Oxidation and diffusion processes in nickel-titanium oxide systems. Surf Sci 1993, 295(3):402-410.
-
(1993)
Surf Sci
, vol.295
, Issue.3
, pp. 402-410
-
-
Espinós, J.P.1
Fernández, A.2
González-Elipe, A.R.3
-
30
-
-
34548166247
-
Biocompatibility-related surface characteristics of oxidized NiTi
-
Danilov A., Tuukkanen T., Tuukkanen J., Jämsä T. Biocompatibility-related surface characteristics of oxidized NiTi. J Biomed Mater Res A 2007, 82A(4):810-819.
-
(2007)
J Biomed Mater Res A
, vol.82 A
, Issue.4
, pp. 810-819
-
-
Danilov, A.1
Tuukkanen, T.2
Tuukkanen, J.3
Jämsä, T.4
-
31
-
-
36749111840
-
Single-crystal elastic constants of the equiatomic NiTi alloy near the martensitic transformation
-
Mercier O., Melton K.N., Gremaud G., Hägi J. Single-crystal elastic constants of the equiatomic NiTi alloy near the martensitic transformation. J Appl Phys 1980, 51(3):1833-1834.
-
(1980)
J Appl Phys
, vol.51
, Issue.3
, pp. 1833-1834
-
-
Mercier, O.1
Melton, K.N.2
Gremaud, G.3
Hägi, J.4
-
32
-
-
0035570621
-
Physicochemical and biological aspects of Nitinol as a biomaterial
-
Shabalovskaya S.A. Physicochemical and biological aspects of Nitinol as a biomaterial. Int Mater Rev 2001, 46(5):233-250.
-
(2001)
Int Mater Rev
, vol.46
, Issue.5
, pp. 233-250
-
-
Shabalovskaya, S.A.1
-
33
-
-
0032403412
-
Effect of modification of oxide layer on NiTi stent corrosion resistance
-
Trépanier C., Tabrizian M., Yahia L.H., Bilodeau L., Piron D.L. Effect of modification of oxide layer on NiTi stent corrosion resistance. J Biomed Mater Res 1998, 43(4):433-440.
-
(1998)
J Biomed Mater Res
, vol.43
, Issue.4
, pp. 433-440
-
-
Trépanier, C.1
Tabrizian, M.2
Yahia, L.H.3
Bilodeau, L.4
Piron, D.L.5
-
34
-
-
0041467739
-
Effect of chemical etching and aging in boiling water on the corrosion resistance of Nitinol wires with black oxide resulting from manufacturing process
-
Shabalovskaya S., Rondelli G., Anderegg J., Simpson B., Budko S. Effect of chemical etching and aging in boiling water on the corrosion resistance of Nitinol wires with black oxide resulting from manufacturing process. J Biomed Mater Res B Appl Biomater 2003, 66(1):331-340.
-
(2003)
J Biomed Mater Res B Appl Biomater
, vol.66
, Issue.1
, pp. 331-340
-
-
Shabalovskaya, S.1
Rondelli, G.2
Anderegg, J.3
Simpson, B.4
Budko, S.5
-
35
-
-
16344371208
-
Behaviour of human endothelial cells on surface modified NiTi alloy
-
Plant S.D., Grant D.M., Leach L. Behaviour of human endothelial cells on surface modified NiTi alloy. Biomaterials 2005, 26(26):5359-5367.
-
(2005)
Biomaterials
, vol.26
, Issue.26
, pp. 5359-5367
-
-
Plant, S.D.1
Grant, D.M.2
Leach, L.3
-
37
-
-
33646356220
-
New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility
-
Michiardi A., Aparicio C., Planell J.A., Gil F.J. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility. J Biomed Mater Res B Appl Biomater 2006, 77B(2):249-256.
-
(2006)
J Biomed Mater Res B Appl Biomater
, vol.77 B
, Issue.2
, pp. 249-256
-
-
Michiardi, A.1
Aparicio, C.2
Planell, J.A.3
Gil, F.J.4
-
38
-
-
11244258494
-
The corrosion and nickel release behavior of laser surfacemelted NiTi shape memory alloy in Hanks' solution
-
Cui Z.D., Man H.C., Yang X.J. The corrosion and nickel release behavior of laser surfacemelted NiTi shape memory alloy in Hanks' solution. Surf Coat Technol 2005, 192(2-3):347-353.
-
(2005)
Surf Coat Technol
, vol.192
, Issue.2-3
, pp. 347-353
-
-
Cui, Z.D.1
Man, H.C.2
Yang, X.J.3
-
39
-
-
0031077930
-
Excimer laser treatment of NiTi shape memory alloy biomaterials
-
Villermaux F., Tabrizian M., Yahia L.H., Meunier M., Piron D.L. Excimer laser treatment of NiTi shape memory alloy biomaterials. Appl Surf Sci 1997, 109-110:62-66.
-
(1997)
Appl Surf Sci
, pp. 62-66
-
-
Villermaux, F.1
Tabrizian, M.2
Yahia, L.H.3
Meunier, M.4
Piron, D.L.5
-
40
-
-
84903914955
-
Effect of the pulsed electron beam melting on a chemical composition and surface layer microstructure of the TiNi alloy
-
Tomsk, Russia
-
th International Conference on Modification of Materials with Particle Beams and Plasma Flows 2004, Tomsk, Russia.
-
(2004)
th International Conference on Modification of Materials with Particle Beams and Plasma Flows
-
-
Meisner, L.L.1
Lotkov, A.I.2
Psachje, S.G.3
Barmina, E.G.4
Rotshtein, V.P.5
Karlik, K.V.6
Markov, A.B.7
-
41
-
-
33751067289
-
Structural-phase condition, unelastic and plastic behavior and nanohardness of the TiNi surface layers modified by an ion- and electron irradiation
-
Meisner L.L., Lotkov A.I., Sivokha V.P., Rotshtein V.P., Barmina E.G., Girjakova Y.L. Structural-phase condition, unelastic and plastic behavior and nanohardness of the TiNi surface layers modified by an ion- and electron irradiation. Mater Sci Eng A 2006, 438-440:558-562.
-
(2006)
Mater Sci Eng A
, pp. 558-562
-
-
Meisner, L.L.1
Lotkov, A.I.2
Sivokha, V.P.3
Rotshtein, V.P.4
Barmina, E.G.5
Girjakova, Y.L.6
-
42
-
-
0027168664
-
2-treated titanium surfaces in contact with blood plasma and a simulated body fluid
-
2-treated titanium surfaces in contact with blood plasma and a simulated body fluid. Clin Mater 1993, 12(3):141-148.
-
(1993)
Clin Mater
, vol.12
, Issue.3
, pp. 141-148
-
-
Wälivaara, B.1
Lundström, I.2
Tengvall, P.3
-
43
-
-
0028107940
-
Titanium with different oxides: in vitro studies of protein adsorption and contact activation
-
Wälivaara B., Aronsson B.-O., Rodahl M., Lausmaa J., Tengvall P. Titanium with different oxides: in vitro studies of protein adsorption and contact activation. Biomaterials 1994, 15(10):827-834.
-
(1994)
Biomaterials
, vol.15
, Issue.10
, pp. 827-834
-
-
Wälivaara, B.1
Aronsson, B.-O.2
Rodahl, M.3
Lausmaa, J.4
Tengvall, P.5
-
44
-
-
84956040351
-
Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants
-
Shabalovskaya S.A., Anderegg J.W. Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants. J Vac Sci Technol A 1995, 13(5):2624-2632.
-
(1995)
J Vac Sci Technol A
, vol.13
, Issue.5
, pp. 2624-2632
-
-
Shabalovskaya, S.A.1
Anderegg, J.W.2
-
45
-
-
0038462111
-
Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets
-
Choi J., Bogdanski D., Köller M., Esenwein S.A., Müller D., Muhr G., Epple M. Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets. Biomaterials 2003, 24:3689-3696.
-
(2003)
Biomaterials
, vol.24
, pp. 3689-3696
-
-
Choi, J.1
Bogdanski, D.2
Köller, M.3
Esenwein, S.A.4
Müller, D.5
Muhr, G.6
Epple, M.7
-
46
-
-
2342433335
-
Inhibition of PMN apoptosis after adherence to dip-coated calcium phosphate surfaces on a NiTi shape memory alloy
-
Bogdanski D., Esenwein S.A., Prymak O., Epple M., Muhr G., Köller M. Inhibition of PMN apoptosis after adherence to dip-coated calcium phosphate surfaces on a NiTi shape memory alloy. Biomaterials 2004, 25(19):4627-4632.
-
(2004)
Biomaterials
, vol.25
, Issue.19
, pp. 4627-4632
-
-
Bogdanski, D.1
Esenwein, S.A.2
Prymak, O.3
Epple, M.4
Muhr, G.5
Köller, M.6
-
47
-
-
84903921669
-
ASTM F86-04 Standard practice for surface preparation and marking of metallic surgical implants
-
Astm International. ASTM, Philadelphia
-
Astm International ASTM F86-04 Standard practice for surface preparation and marking of metallic surgical implants. Annual book of ASTM standards 1996, ASTM, Philadelphia.
-
(1996)
Annual book of ASTM standards
-
-
-
48
-
-
26844515262
-
Reduced thrombogenicity of nitinol stents - in vitro evaluation of different surface modifications and coatings
-
Tepe G., Schmehl J., Wendel H.P., Schaffner S., Heller S., Gianotti M., Claussen C.D., Duda S.H. Reduced thrombogenicity of nitinol stents - in vitro evaluation of different surface modifications and coatings. Biomaterials 2006, 27(4):643-650.
-
(2006)
Biomaterials
, vol.27
, Issue.4
, pp. 643-650
-
-
Tepe, G.1
Schmehl, J.2
Wendel, H.P.3
Schaffner, S.4
Heller, S.5
Gianotti, M.6
Claussen, C.D.7
Duda, S.H.8
-
49
-
-
0036668139
-
Investigation on plasma immersion ion implantation treated medical implants
-
Mändl S., Sader R., Thorwarth G., Krause D., Zeilhofer H.-F., Horch H.H., Rauschenbach B. Investigation on plasma immersion ion implantation treated medical implants. Biomol Eng 2002, 19(2-6):129-132.
-
(2002)
Biomol Eng
, vol.19
, Issue.2-6
, pp. 129-132
-
-
Mändl, S.1
Sader, R.2
Thorwarth, G.3
Krause, D.4
Zeilhofer, H.-F.5
Horch, H.H.6
Rauschenbach, B.7
-
50
-
-
13844296463
-
Corrosion resistance of NiTi after nitrogen, oxygen, and hydrogen plasma immersion ion implantation
-
Sydney, Australia
-
Poon R.W.Y., Liu X.Y., Chung J.C.Y., Yeung K.W.K., Lu W.W., Cheung K.M.C., Chu P.K. Corrosion resistance of NiTi after nitrogen, oxygen, and hydrogen plasma immersion ion implantation. 6th World Biomaterials Congress 2004, Sydney, Australia.
-
(2004)
6th World Biomaterials Congress
-
-
Poon, R.W.Y.1
Liu, X.Y.2
Chung, J.C.Y.3
Yeung, K.W.K.4
Lu, W.W.5
Cheung, K.M.C.6
Chu, P.K.7
-
51
-
-
33645119700
-
Plasma immersion ion implanted nitinol surface with depressed nickel concentration for implants in blood
-
Maitz M.F., Shevchenko N. Plasma immersion ion implanted nitinol surface with depressed nickel concentration for implants in blood. J Biomed Mater Res A 2005, 76A(2):356-365.
-
(2005)
J Biomed Mater Res A
, vol.76 A
, Issue.2
, pp. 356-365
-
-
Maitz, M.F.1
Shevchenko, N.2
-
52
-
-
33847350671
-
Reactive plasma immersion ion implantation for surface passivation
-
Yankov R.A., Shevchenko N., Rogozin A., Maitz M.F., Richter E., Möller W., Donchev A., Schütze M. Reactive plasma immersion ion implantation for surface passivation. Surf Coat Technol 2007, 201:6752-6758.
-
(2007)
Surf Coat Technol
, vol.201
, pp. 6752-6758
-
-
Yankov, R.A.1
Shevchenko, N.2
Rogozin, A.3
Maitz, M.F.4
Richter, E.5
Möller, W.6
Donchev, A.7
Schütze, M.8
-
53
-
-
10944268753
-
Anti-corrosion performance of oxidized and oxygen plasma-implanted NiTi alloys
-
Poon R.W.Y., Ho J.P.Y., Liu X., Chung C.Y., Chu P.K., Yeung K.W.K., Lu W.W., Cheung K.M.C. Anti-corrosion performance of oxidized and oxygen plasma-implanted NiTi alloys. Mater Sci Eng A 2005, 390(1-2):444-451.
-
(2005)
Mater Sci Eng A
, vol.390
, Issue.1-2
, pp. 444-451
-
-
Poon, R.W.Y.1
Ho, J.P.Y.2
Liu, X.3
Chung, C.Y.4
Chu, P.K.5
Yeung, K.W.K.6
Lu, W.W.7
Cheung, K.M.C.8
-
54
-
-
0242666828
-
Surface modification of TiNi alloy through tantalum immersion ion implantation
-
Cheng Y., Wei C., Gan K.Y., Zhao L.C. Surface modification of TiNi alloy through tantalum immersion ion implantation. Surf Coat Technol 2004, 176(2):261-265.
-
(2004)
Surf Coat Technol
, vol.176
, Issue.2
, pp. 261-265
-
-
Cheng, Y.1
Wei, C.2
Gan, K.Y.3
Zhao, L.C.4
-
55
-
-
0035803946
-
TiN coating improves the corrosion behavior of superelastic NiTi surgical alloy
-
Starosvetsky D., Gotman I. TiN coating improves the corrosion behavior of superelastic NiTi surgical alloy. Surf Coat Technol 2001, 148:268-276.
-
(2001)
Surf Coat Technol
, vol.148
, pp. 268-276
-
-
Starosvetsky, D.1
Gotman, I.2
-
56
-
-
0034087518
-
Titanium nitride coatings on surgical titanium alloys produced by a powder immersion reaction assisted coating method: residual stresses and fretting behavior
-
Shenhar A., Gotman I., Radin S., Ducheyne P., Gutmanas E.Y. Titanium nitride coatings on surgical titanium alloys produced by a powder immersion reaction assisted coating method: residual stresses and fretting behavior. Surf Coat Technol 2000, 126:210-218.
-
(2000)
Surf Coat Technol
, vol.126
, pp. 210-218
-
-
Shenhar, A.1
Gotman, I.2
Radin, S.3
Ducheyne, P.4
Gutmanas, E.Y.5
-
57
-
-
0028704565
-
Effects of titanium nitride coatings on surface and corrosion characteristics of Ni-Ti alloy
-
Endo K., Sachdeva R., Araki Y., Ohno H. Effects of titanium nitride coatings on surface and corrosion characteristics of Ni-Ti alloy. Dent Mater J 1994, 13(2):228-239.
-
(1994)
Dent Mater J
, vol.13
, Issue.2
, pp. 228-239
-
-
Endo, K.1
Sachdeva, R.2
Araki, Y.3
Ohno, H.4
-
58
-
-
34447325630
-
Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages
-
Liu X.M., Wu S.L., Chan Y.L., Chu P.K., Chung C.Y., Chu C.L., Yeung K.W.K., Lu W.W., Cheung K.M.C., Luk K.D.K. Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages. J Biomed Mater Res A 2007, 82A(2):469-478.
-
(2007)
J Biomed Mater Res A
, vol.82 A
, Issue.2
, pp. 469-478
-
-
Liu, X.M.1
Wu, S.L.2
Chan, Y.L.3
Chu, P.K.4
Chung, C.Y.5
Chu, C.L.6
Yeung, K.W.K.7
Lu, W.W.8
Cheung, K.M.C.9
Luk, K.D.K.10
-
59
-
-
4344574094
-
Studies of surface modified NiTi alloy
-
Shevchenko N., Pham M.-T., Maitz M.F. Studies of surface modified NiTi alloy. Appl Surf Sci 2004, 235(1-2):126-131.
-
(2004)
Appl Surf Sci
, vol.235
, Issue.1-2
, pp. 126-131
-
-
Shevchenko, N.1
Pham, M.-T.2
Maitz, M.F.3
-
60
-
-
33747343183
-
2/Ar gas flow ratio on the deposition of TiN/Ti coatings on NiTi shape memory alloy by PIIID
-
2/Ar gas flow ratio on the deposition of TiN/Ti coatings on NiTi shape memory alloy by PIIID. Mater Lett 2006, 60(17-18):2243-2247.
-
(2006)
Mater Lett
, vol.60
, Issue.17-18
, pp. 2243-2247
-
-
Cheng, Y.1
Zheng, Y.F.2
-
61
-
-
0027590280
-
Sol-gel processing of titaniumcontaining thin coatings. Part I. Preparation and structure
-
Samuneva B., Kozhukharov V., Trapalis C., Kranold R. Sol-gel processing of titaniumcontaining thin coatings. Part I. Preparation and structure. J Mater Sci 1993, 28(9):2353-2360.
-
(1993)
J Mater Sci
, vol.28
, Issue.9
, pp. 2353-2360
-
-
Samuneva, B.1
Kozhukharov, V.2
Trapalis, C.3
Kranold, R.4
-
63
-
-
0019317954
-
Amorphous and crystalline dip coatings obtained from organometallic solutions: Procedures, chemical processes and products
-
Dislich H., Hussmann E. Amorphous and crystalline dip coatings obtained from organometallic solutions: Procedures, chemical processes and products. Thin Solid Films 1981, 77(1-3):129-140.
-
(1981)
Thin Solid Films
, vol.77
, Issue.1-3
, pp. 129-140
-
-
Dislich, H.1
Hussmann, E.2
-
64
-
-
0033973739
-
Titanium dioxide ceramics control the differentiated phenotype of cardiac muscle cells in culture
-
Polonchuk L., Elbel J., Eckert L., Blum J., Wintermantel E., Eppenberger H.M. Titanium dioxide ceramics control the differentiated phenotype of cardiac muscle cells in culture. Biomaterials 2000, 21(6):539-550.
-
(2000)
Biomaterials
, vol.21
, Issue.6
, pp. 539-550
-
-
Polonchuk, L.1
Elbel, J.2
Eckert, L.3
Blum, J.4
Wintermantel, E.5
Eppenberger, H.M.6
-
65
-
-
0032487121
-
Calcium phosphate induction by sol-gel-derived titania coatings on titanium substrates in vitro
-
Peltola T., Patsi M., Rahiala H., Kangasniemi I., Yli-Urpo A. Calcium phosphate induction by sol-gel-derived titania coatings on titanium substrates in vitro. J Biomed Mater Res 1998, 41(3):504-510.
-
(1998)
J Biomed Mater Res
, vol.41
, Issue.3
, pp. 504-510
-
-
Peltola, T.1
Patsi, M.2
Rahiala, H.3
Kangasniemi, I.4
Yli-Urpo, A.5
-
66
-
-
12344298672
-
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
-
Liu X., Chu P.K., Ding C. Surface modification of titanium, titanium alloys, and related materials for biomedical applications. Mater Sci Eng R 2004, 47(3-4):49-121.
-
(2004)
Mater Sci Eng R
, vol.47
, Issue.3-4
, pp. 49-121
-
-
Liu, X.1
Chu, P.K.2
Ding, C.3
-
67
-
-
0032022546
-
Bonding strengths of titania sol-gel derived coatings on titanium
-
Pätsi M.E., Hautaniemi J.A., Rahiala H.M., Peltola T.O., Kangasniemi I.M.O. Bonding strengths of titania sol-gel derived coatings on titanium. J Sol-Gel Sci Technol 1998, 11(1):55-66.
-
(1998)
J Sol-Gel Sci Technol
, vol.11
, Issue.1
, pp. 55-66
-
-
Pätsi, M.E.1
Hautaniemi, J.A.2
Rahiala, H.M.3
Peltola, T.O.4
Kangasniemi, I.M.O.5
-
68
-
-
0027592463
-
Porcelain bonding on Ti: Its dependence on surface roughness, firing time and vacuum level
-
Hautaniemi J.A., Juhanoja J.T., Herø H. Porcelain bonding on Ti: Its dependence on surface roughness, firing time and vacuum level. Surf Interface Anal 1993, 20(5):421-426.
-
(1993)
Surf Interface Anal
, vol.20
, Issue.5
, pp. 421-426
-
-
Hautaniemi, J.A.1
Juhanoja, J.T.2
Herø, H.3
-
69
-
-
0030298049
-
Preparation of bioactive Ti and its alloys via simple chemical surface treatment
-
Kim H.M., Miyaji F., Kokubo T., Nakamura T. Preparation of bioactive Ti and its alloys via simple chemical surface treatment. J Biomed Mater Res 1996, 32(3):409-417.
-
(1996)
J Biomed Mater Res
, vol.32
, Issue.3
, pp. 409-417
-
-
Kim, H.M.1
Miyaji, F.2
Kokubo, T.3
Nakamura, T.4
-
70
-
-
0028069746
-
The role of hydrated silica, titania, and alumina in inducing apatite on implants
-
Li P., Ohtsuki C., Kokubo T., Nakanishi K., Soga N., De Groot K. The role of hydrated silica, titania, and alumina in inducing apatite on implants. J Biomed Mater Res 1994, 28(1):7-15.
-
(1994)
J Biomed Mater Res
, vol.28
, Issue.1
, pp. 7-15
-
-
Li, P.1
Ohtsuki, C.2
Kokubo, T.3
Nakanishi, K.4
Soga, N.5
De Groot, K.6
-
71
-
-
23244448563
-
Biomimetic deposition of apatite coating on surface-modified NiTi alloy
-
Gu Y.W., Tay B.Y., Lim C.S., Yong M.S. Biomimetic deposition of apatite coating on surface-modified NiTi alloy. Biomaterials 2005, 26(34):6916-6923.
-
(2005)
Biomaterials
, vol.26
, Issue.34
, pp. 6916-6923
-
-
Gu, Y.W.1
Tay, B.Y.2
Lim, C.S.3
Yong, M.S.4
-
72
-
-
0032052625
-
Electrochemical and surface characterization of a nickel-titanium alloy
-
Wever D.J., Veldhuizen A.G., De Vries J., Busscher H.J., Uges D.R., Van Horn J.R. Electrochemical and surface characterization of a nickel-titanium alloy. Biomaterials 1998, 19(7-9):761-769.
-
(1998)
Biomaterials
, vol.19
, Issue.7-9
, pp. 761-769
-
-
Wever, D.J.1
Veldhuizen, A.G.2
De Vries, J.3
Busscher, H.J.4
Uges, D.R.5
Van Horn, J.R.6
-
73
-
-
34447498812
-
Enhancement of surface properties of biomaterials using plasma-based technologies
-
Chu P.K. Enhancement of surface properties of biomaterials using plasma-based technologies. Surf Coat Technol 2007, 201(19-20):8076-8082.
-
(2007)
Surf Coat Technol
, vol.201
, Issue.19-20
, pp. 8076-8082
-
-
Chu, P.K.1
-
74
-
-
33748943616
-
Effect of diamond-like carbon (DLC) on the properties of the NiTi alloys
-
Sui J.H., Cai W. Effect of diamond-like carbon (DLC) on the properties of the NiTi alloys. Diam Rel Mater 2006, 15(10):1720-1726.
-
(2006)
Diam Rel Mater
, vol.15
, Issue.10
, pp. 1720-1726
-
-
Sui, J.H.1
Cai, W.2
-
75
-
-
33846500137
-
Plasma surface treatment of artificial orthopedic and cardiovascular biomaterials
-
Chu P.K. Plasma surface treatment of artificial orthopedic and cardiovascular biomaterials. Surf Coat Techn 2007, 201(9-11):5601-5606.
-
(2007)
Surf Coat Techn
, vol.201
, Issue.9-11
, pp. 5601-5606
-
-
Chu, P.K.1
-
76
-
-
10044220962
-
Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys
-
Poon R.W.Y., Yeung K.W.K., Liu X.Y., Chu P.K., Chung C.Y., Lu W.W., Cheung K.M.C., Chan D. Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys. Biomaterials 2005, 26(15):2265-2272.
-
(2005)
Biomaterials
, vol.26
, Issue.15
, pp. 2265-2272
-
-
Poon, R.W.Y.1
Yeung, K.W.K.2
Liu, X.Y.3
Chu, P.K.4
Chung, C.Y.5
Lu, W.W.6
Cheung, K.M.C.7
Chan, D.8
-
77
-
-
33645386247
-
The BioDiamond and BioDiamond F stents
-
Dunitz, London, P.W. Serruys, M.J.B. Kutryk (Eds.)
-
Barragan P., Herbst F., Kalachev A., Nader W.F., Roquebert P.O., Silvestri M., Siméoni J.B. The BioDiamond and BioDiamond F stents. Handbook of coronary stents 2000, 29-39. Dunitz, London. 3 edn. P.W. Serruys, M.J.B. Kutryk (Eds.).
-
(2000)
Handbook of coronary stents
, pp. 29-39
-
-
Barragan, P.1
Herbst, F.2
Kalachev, A.3
Nader, W.F.4
Roquebert, P.O.5
Silvestri, M.6
Siméoni, J.B.7
-
79
-
-
0034175826
-
Clinical and angiographic outcome after coronary arterial stenting with the carbostent
-
Antoniucci D., Bartorelli A., Valenti R., Montorsi P., Santoro G.M., Fabbiocchi F., Bolognese L., Loaldi A., Trapani M., Trabattoni D., Moschi G., Galli S. Clinical and angiographic outcome after coronary arterial stenting with the carbostent. Am J Cardiol 2000, 85(7):821-825.
-
(2000)
Am J Cardiol
, vol.85
, Issue.7
, pp. 821-825
-
-
Antoniucci, D.1
Bartorelli, A.2
Valenti, R.3
Montorsi, P.4
Santoro, G.M.5
Fabbiocchi, F.6
Bolognese, L.7
Loaldi, A.8
Trapani, M.9
Trabattoni, D.10
Moschi, G.11
Galli, S.12
-
80
-
-
6444245711
-
3/sp2 contents of diamond-like carbon (DLC) synthesized by plasma immersion ion implantation-deposition
-
3/sp2 contents of diamond-like carbon (DLC) synthesized by plasma immersion ion implantation-deposition. Surf Coat Technol 2002, 156(1-3):289-294.
-
(2002)
Surf Coat Technol
, vol.156
, Issue.1-3
, pp. 289-294
-
-
Chen, J.Y.1
Wang, L.P.2
Fu, K.Y.3
Huang, N.4
Leng, Y.5
Leng, Y.X.6
Yang, P.7
Wang, J.8
Wan, G.J.9
Sun, H.10
Tian, X.B.11
Chu, P.K.12
-
81
-
-
3042850877
-
Hemocompatibility of nitrogen-doped, hydrogen-free diamond-like carbon prepared by nitrogen plasma immersion ion implantation-deposition
-
Kwok S.C.H., Yang P., Wang J., Liu X., Chu P.K. Hemocompatibility of nitrogen-doped, hydrogen-free diamond-like carbon prepared by nitrogen plasma immersion ion implantation-deposition. J Biomed Mater Res 2004, 70A(1):107-114.
-
(2004)
J Biomed Mater Res
, vol.70 A
, Issue.1
, pp. 107-114
-
-
Kwok, S.C.H.1
Yang, P.2
Wang, J.3
Liu, X.4
Chu, P.K.5
-
82
-
-
28544446215
-
Wettability and biocompatibility of nitrogen-doped hydrogenated amorphous carbon films: Effect of nitrogen
-
Yang P., Huang N., Leng Y.X., Yao Z.Q., Zhou H.F., Maitz M., Leng Y., Chu P.K. Wettability and biocompatibility of nitrogen-doped hydrogenated amorphous carbon films: Effect of nitrogen. Nucl Instrum Methods Phys Res B 2006, 242:22-25.
-
(2006)
Nucl Instrum Methods Phys Res B
, vol.242
, pp. 22-25
-
-
Yang, P.1
Huang, N.2
Leng, Y.X.3
Yao, Z.Q.4
Zhou, H.F.5
Maitz, M.6
Leng, Y.7
Chu, P.K.8
-
83
-
-
33746700249
-
Human microvascular endothelial cellular interaction with atomic N-doped DLC compared with Si-doped DLC thin films
-
Okpalugo T.I.T., Murphy H., Ogwu A.A., Abbas G., Ray S.C., Maguire P.D., Mclaughlin J., Mccullough R.W. Human microvascular endothelial cellular interaction with atomic N-doped DLC compared with Si-doped DLC thin films. J Biomed Mater Res B Appl Biomater 2006, 78B(2):222-229.
-
(2006)
J Biomed Mater Res B Appl Biomater
, vol.78 B
, Issue.2
, pp. 222-229
-
-
Okpalugo, T.I.T.1
Murphy, H.2
Ogwu, A.A.3
Abbas, G.4
Ray, S.C.5
Maguire, P.D.6
Mclaughlin, J.7
Mccullough, R.W.8
-
84
-
-
4243386780
-
Growth mechanism and cross-sectional structure of tetrahedral amorphous carbon thin films
-
Davis C.A., Amaratunga G.A.J., Knowles K.M. Growth mechanism and cross-sectional structure of tetrahedral amorphous carbon thin films. Phys Rev Lett 1998, 80(15):3280.
-
(1998)
Phys Rev Lett
, vol.80
, Issue.15
, pp. 3280
-
-
Davis, C.A.1
Amaratunga, G.A.J.2
Knowles, K.M.3
-
85
-
-
17144445444
-
Spectroscopic ellipsometry investigation of amorphous carbon films with different sp3 content: relation with protein adsorption
-
Vinnichenko M., Gago R., Huang N., Leng Y.X., Sun H., Kreissig U., Kulish M.P., Maitz M.F. Spectroscopic ellipsometry investigation of amorphous carbon films with different sp3 content: relation with protein adsorption. Thin Solid Films 2004, 455-456C:530-534.
-
(2004)
Thin Solid Films
, pp. 530-534
-
-
Vinnichenko, M.1
Gago, R.2
Huang, N.3
Leng, Y.X.4
Sun, H.5
Kreissig, U.6
Kulish, M.P.7
Maitz, M.F.8
-
86
-
-
0030332536
-
Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating
-
Villermaux F., Tabrizian M., Yahia L., Czeremuszkin G., Piron D.L. Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating. Biomed Mater Eng 1996, 6(4):241-254.
-
(1996)
Biomed Mater Eng
, vol.6
, Issue.4
, pp. 241-254
-
-
Villermaux, F.1
Tabrizian, M.2
Yahia, L.3
Czeremuszkin, G.4
Piron, D.L.5
-
87
-
-
0033939780
-
DC plasma-polymerized hexamethyldisilazane coatings of an equiatomic TiNi shape memory alloy
-
Yang M.-R., Wu S.K. DC plasma-polymerized hexamethyldisilazane coatings of an equiatomic TiNi shape memory alloy. Surf Coat Technol 2000, 127(2-3):273-280.
-
(2000)
Surf Coat Technol
, vol.127
, Issue.2-3
, pp. 273-280
-
-
Yang, M.-R.1
Wu, S.K.2
-
89
-
-
31544474052
-
Structural evaluation of radially expandable cardiovascular stents encased in a polyurethane film
-
Trigwell S., De S., Sharma R., Mazumder M.K., Mehta J.L. Structural evaluation of radially expandable cardiovascular stents encased in a polyurethane film. J Biomed Mater Res B Appl Biomater 2006, 76B(2):241-250.
-
(2006)
J Biomed Mater Res B Appl Biomater
, vol.76 B
, Issue.2
, pp. 241-250
-
-
Trigwell, S.1
De, S.2
Sharma, R.3
Mazumder, M.K.4
Mehta, J.L.5
-
90
-
-
0348230671
-
Corrosion resistance of polyurethane-coated nitinol cardiovascular stents
-
Mazumder M.M., De S., Trigwell S., Ali N., Mazumder M.K., Mehta J.L. Corrosion resistance of polyurethane-coated nitinol cardiovascular stents. J Biomater Sci Polym Ed 2003, 14(12):1351-1362.
-
(2003)
J Biomater Sci Polym Ed
, vol.14
, Issue.12
, pp. 1351-1362
-
-
Mazumder, M.M.1
De, S.2
Trigwell, S.3
Ali, N.4
Mazumder, M.K.5
Mehta, J.L.6
-
91
-
-
12444296479
-
Crosslinked polyurethane coating on vascular stents for enhanced X-ray contrast
-
Kondyurin A., Romanova V., Begishev V., Kondyurina I., Guenzel R., Maitz M.F. Crosslinked polyurethane coating on vascular stents for enhanced X-ray contrast. J Bioact Compat Polym 2005, 20(1):77-93.
-
(2005)
J Bioact Compat Polym
, vol.20
, Issue.1
, pp. 77-93
-
-
Kondyurin, A.1
Romanova, V.2
Begishev, V.3
Kondyurina, I.4
Guenzel, R.5
Maitz, M.F.6
-
92
-
-
0028765988
-
Vibrational spectra of some diisocyanates in the liquid state or on EPDM-40 rubber surface
-
Kondyurin A., Klyachkin Y. Vibrational spectra of some diisocyanates in the liquid state or on EPDM-40 rubber surface. J Appl Polym Sci 1994, 54(10):1385-1393.
-
(1994)
J Appl Polym Sci
, vol.54
, Issue.10
, pp. 1385-1393
-
-
Kondyurin, A.1
Klyachkin, Y.2
-
93
-
-
9944224238
-
Surface properties of bio-implant Nitinol modified by ECR cold plasma
-
Yang J., Wang J., Tong S. Surface properties of bio-implant Nitinol modified by ECR cold plasma. Mater Sci Technol 2004, 20(11):1427-1430.
-
(2004)
Mater Sci Technol
, vol.20
, Issue.11
, pp. 1427-1430
-
-
Yang, J.1
Wang, J.2
Tong, S.3
-
94
-
-
34249658951
-
Plasma-deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition
-
Cao L., Chang M., Lee C.-Y., Castner D.G., Sukavaneshvar S., Ratner B.D., Horbett T.A. Plasma-deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition. J Biomed Mater Res A 2007, 81A(4):827-837.
-
(2007)
J Biomed Mater Res A
, vol.81 A
, Issue.4
, pp. 827-837
-
-
Cao, L.1
Chang, M.2
Lee, C.-Y.3
Castner, D.G.4
Sukavaneshvar, S.5
Ratner, B.D.6
Horbett, T.A.7
-
95
-
-
0032928387
-
Polyethylene terephthalate and polyurethane coatings for endovascular stents: preliminary results in canine experimental arteriovenous fistulas
-
Schellhammer F., Walter M., Berlis A., Bloss H.G., Wellens E., Schumacher M. Polyethylene terephthalate and polyurethane coatings for endovascular stents: preliminary results in canine experimental arteriovenous fistulas. Radiology 1999, 211(1):169-175.
-
(1999)
Radiology
, vol.211
, Issue.1
, pp. 169-175
-
-
Schellhammer, F.1
Walter, M.2
Berlis, A.3
Bloss, H.G.4
Wellens, E.5
Schumacher, M.6
-
96
-
-
0035103757
-
Biocompatibility and performance of the Wallstent and several covered stents in a sheep iliac artery model
-
Cejna M., Virmani R., Jones R., Bergmeister H., Losert U., Xu Z., Yang P., Schoder M., Lammer J. Biocompatibility and performance of the Wallstent and several covered stents in a sheep iliac artery model. J Vasc Interv Radiol 2001, 12(3):351-358.
-
(2001)
J Vasc Interv Radiol
, vol.12
, Issue.3
, pp. 351-358
-
-
Cejna, M.1
Virmani, R.2
Jones, R.3
Bergmeister, H.4
Losert, U.5
Xu, Z.6
Yang, P.7
Schoder, M.8
Lammer, J.9
-
97
-
-
34547741083
-
Current strategies towards hemocompatible coatings
-
Werner C., Maitz M.F., Sperling C. Current strategies towards hemocompatible coatings. J Mater Chem 2007, 17:3376-3384.
-
(2007)
J Mater Chem
, vol.17
, pp. 3376-3384
-
-
Werner, C.1
Maitz, M.F.2
Sperling, C.3
-
98
-
-
33644843665
-
Biodegradable membrane-covered stent from chitosan-based polymers
-
Thierry B., Merhi Y., Silver J., Tabrizian M. Biodegradable membrane-covered stent from chitosan-based polymers. J Biomed Mater Res A 2005, 75A(3):556-566.
-
(2005)
J Biomed Mater Res A
, vol.75 A
, Issue.3
, pp. 556-566
-
-
Thierry, B.1
Merhi, Y.2
Silver, J.3
Tabrizian, M.4
-
99
-
-
2542629648
-
Anticoagulant and antiplatelet agents: their clinical and device application(s) together with usages to engineer surfaces
-
Kidane A.G., Salacinski H., Tiwari A., Bruckdorfer K.R., Seifalian A.M. Anticoagulant and antiplatelet agents: their clinical and device application(s) together with usages to engineer surfaces. Biomacromolecules 2004, 5(3):798-813.
-
(2004)
Biomacromolecules
, vol.5
, Issue.3
, pp. 798-813
-
-
Kidane, A.G.1
Salacinski, H.2
Tiwari, A.3
Bruckdorfer, K.R.4
Seifalian, A.M.5
-
100
-
-
0347384110
-
Optimal heparin surface concentration and antithrombin binding capacity as evaluated with human nonanticoagulated blood in vitro
-
Andersson J., Sanchez J., Ekdahl K.N., Elgue G., Nilsson B., Larsson R. Optimal heparin surface concentration and antithrombin binding capacity as evaluated with human nonanticoagulated blood in vitro. J Biomed Mater Res A 2003, 67(2):458-466.
-
(2003)
J Biomed Mater Res A
, vol.67
, Issue.2
, pp. 458-466
-
-
Andersson, J.1
Sanchez, J.2
Ekdahl, K.N.3
Elgue, G.4
Nilsson, B.5
Larsson, R.6
-
101
-
-
33744537149
-
Mechanisms of controlled drug release from drug-eluting stents
-
Acharya G., Park K. Mechanisms of controlled drug release from drug-eluting stents. Adv Drug Deliv Rev 2006, 58(3):387-401.
-
(2006)
Adv Drug Deliv Rev
, vol.58
, Issue.3
, pp. 387-401
-
-
Acharya, G.1
Park, K.2
-
102
-
-
9644310219
-
2™ drug-eluting stent
-
2™ drug-eluting stent. J Biomed Mater Res 2004, 71A(4):625-634.
-
(2004)
J Biomed Mater Res
, vol.71 A
, Issue.4
, pp. 625-634
-
-
Ranade, S.V.1
Miller, K.M.2
Richard, R.E.3
Chan, A.K.4
Allen, M.J.5
Helmus, M.N.6
-
103
-
-
0037126077
-
Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease: six-month results
-
Duda S.H., Pusich B., Richter G., Landwehr P., Oliva V.L., Tielbeek A., Wiesinger B., Hak J.B., Tielemans H., Ziemer G., Cristea E., Lansky A., Bérégi J.P. Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease: six-month results. Circulation 2002, 106(12):1505-1509.
-
(2002)
Circulation
, vol.106
, Issue.12
, pp. 1505-1509
-
-
Duda, S.H.1
Pusich, B.2
Richter, G.3
Landwehr, P.4
Oliva, V.L.5
Tielbeek, A.6
Wiesinger, B.7
Hak, J.B.8
Tielemans, H.9
Ziemer, G.10
Cristea, E.11
Lansky, A.12
Bérégi, J.P.13
-
104
-
-
0038711003
-
New frontiers in cardiology: drug-eluting stents: Part I
-
Sousa J.E., Serruys P.W., Costa M.A. New frontiers in cardiology: drug-eluting stents: Part I. Circulation 2003, 107(17):2274-2279.
-
(2003)
Circulation
, vol.107
, Issue.17
, pp. 2274-2279
-
-
Sousa, J.E.1
Serruys, P.W.2
Costa, M.A.3
-
105
-
-
0038711003
-
New frontiers in cardiology: drug-eluting stents: Part II
-
Sousa J.E., Serruys P.W., Costa M.A. New frontiers in cardiology: drug-eluting stents: Part II. Circulation 2003, 107(18):2383-2389.
-
(2003)
Circulation
, vol.107
, Issue.18
, pp. 2383-2389
-
-
Sousa, J.E.1
Serruys, P.W.2
Costa, M.A.3
-
107
-
-
33644848725
-
Prevention of carotid artery restenosis after sirolimuscoated stent implantation in pigs
-
Tepe G., Muschick P., Laule M., Reddig F., Claussen C.D., Dinkelborg L.M., Tielemans H., Wehrmann M., Duda S.H. Prevention of carotid artery restenosis after sirolimuscoated stent implantation in pigs. Stroke 2006, 37(2):492-494.
-
(2006)
Stroke
, vol.37
, Issue.2
, pp. 492-494
-
-
Tepe, G.1
Muschick, P.2
Laule, M.3
Reddig, F.4
Claussen, C.D.5
Dinkelborg, L.M.6
Tielemans, H.7
Wehrmann, M.8
Duda, S.H.9
-
108
-
-
0034666762
-
Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
-
Thierry B., Tabrizian M., Trepanier C., Savadogo O., Yahia L. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy. J Biomed Mater Res 2000, 51(4):685-693.
-
(2000)
J Biomed Mater Res
, vol.51
, Issue.4
, pp. 685-693
-
-
Thierry, B.1
Tabrizian, M.2
Trepanier, C.3
Savadogo, O.4
Yahia, L.5
|