1
-
-
84873997637
-
-
American Heart Association. Stent procedure. Available: http://www.americanheart.org/presenter.jhtml?identifier=4721
-
Stent Procedure
-
-
-
2
-
-
0033984273
-
Acute and chronic tissue response to coronary stent implantation
-
Grewe P, Denecke T, Machroui A. Acute and chronic tissue response to coronary stent implantation. J Am Coll Cardiol 2000;5:157-163.
-
(2000)
J Am Coll Cardiol
, vol.5
, pp. 157-163
-
-
Grewe, P.1
Denecke, T.2
Machroui, A.3
-
5
-
-
0032796799
-
Antithrombic coatings of stents using a biodegradable drug delivery technology
-
Herrmann R, Schmidmaier, Märkl GB, Resch A, Hähnel I, Stemberger A, Alt E. Antithrombic coatings of stents using a biodegradable drug delivery technology. Thromb Haemost 1999;82:51-57.
-
(1999)
Thromb Haemost
, vol.82
, pp. 51-57
-
-
Herrmann, R.1
Schmidmaier2
Märkl, G.B.3
Resch, A.4
Hähnel, I.5
Stemberger, A.6
Alt, E.7
-
8
-
-
0032090001
-
Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications
-
Trigwell S, Hayden RD, Nelson KF, Selvaduray G. Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications. Surf Interface Anal 1998;26: 483-480.
-
(1998)
Surf Interface Anal
, vol.26
, pp. 483-1480
-
-
Trigwell, S.1
Hayden, R.D.2
Nelson, K.F.3
Selvaduray, G.4
-
9
-
-
0037026414
-
Effect of surface treatment of NiTi alloy on its corrosion behavior in Hank's solution
-
Cisse O, Savadogo O, Wu M, Yahia LH. Effect of surface treatment of NiTi alloy on its corrosion behavior in Hank's solution. J Biomed Mater Res 2002;61:339-345.
-
(2002)
J Biomed Mater Res
, vol.61
, pp. 339-345
-
-
Cisse, O.1
Savadogo, O.2
Wu, M.3
Yahia, L.H.4
-
10
-
-
0141670820
-
Biocompatibility and hemocompatibility of surface-modified NiTi alloys
-
Armitage DA, Parker TL, Grant DM. Biocompatibility and hemocompatibility of surface-modified NiTi alloys. J. Biomed Mater Res 2003;66:129-137.
-
(2003)
J. Biomed Mater Res
, vol.66
, pp. 129-137
-
-
Armitage, D.A.1
Parker, T.L.2
Grant, D.M.3
-
12
-
-
0036431877
-
Effect of surface preparation on mechanical properties of a NiTi alloy
-
Miao W, Mi X, Zhu M, Guo J, Kou Y. Effect of surface preparation on mechanical properties of a NiTi alloy. Mater Sci Forum 2002;394-395:173-176.
-
(2002)
Mater Sci Forum
, vol.394-395
, pp. 173-176
-
-
Miao, W.1
Mi, X.2
Zhu, M.3
Guo, J.4
Kou, Y.5
-
14
-
-
0035260465
-
-
Sigwart U, Prasad S, Radke P, Nadra I, Stent coatings. J Invasive Cardiol 2001;13:141-142.
-
(2001)
J Invasive Cardiol
, vol.13
, pp. 141-142
-
-
Sigwart, U.1
Prasad, S.2
Radke, P.3
Nadra, I.4
Coatings, S.5
-
16
-
-
31544468819
-
-
Patent pending
-
Mazumder MM, Mehta JL, Mazumder MK, Ali N, Trigwell S, Sharma R, De S. Encased stent for rapid endothelialization for preventing restenosis. Patent pending; 2004
-
(2004)
Encased Stent for Rapid Endothelialization for Preventing Restenosis
-
-
Mazumder, M.M.1
Mehta, J.L.2
Mazumder, M.K.3
Ali, N.4
Trigwell, S.5
Sharma, R.6
De, S.7
-
18
-
-
0348230671
-
Corrosion resistance of polyurethane-coated nitinol cardiovascular stents
-
Mazumder MM, De S, Trigwell S, Ali N, Mazumder MK, Mehta JL. Corrosion resistance of polyurethane-coated nitinol cardiovascular stents. J Biomater Sci Polym Ed 2003;14:1351-1362.
-
(2003)
J Biomater Sci Polym Ed
, vol.14
, pp. 1351-1362
-
-
Mazumder, M.M.1
De, S.2
Trigwell, S.3
Ali, N.4
Mazumder, M.K.5
Mehta, J.L.6
-
19
-
-
22844438567
-
Endothelial cell growth on plasma-treated polyurethane coated stents for long-term biocompatibility
-
De S, Sharma R, Trigwell S, Laska B, Ali N, Mazumder MK, Mehta JL. Endothelial cell growth on plasma-treated polyurethane coated stents for long-term biocompatibility. J Biomater Sci Polym Ed 2005;16:973-989.
-
(2005)
J Biomater Sci Polym Ed
, vol.16
, pp. 973-989
-
-
De, S.1
Sharma, R.2
Trigwell, S.3
Laska, B.4
Ali, N.5
Mazumder, M.K.6
Mehta, J.L.7
-
24
-
-
0001255625
-
Contact angle hysteresis II. Contact angle measurements on rough surfaces
-
Gould RF, editor. Washington, DC: ACS
-
Dettre RH, Johnson RE. Contact angle hysteresis II. Contact angle measurements on rough surfaces. In: Gould RF, editor. Contact angle, wettability, and adhesion. Washington, DC: ACS; 1964. 25. Zisman WA. Relation of the equilibrium contact angle to liquid and solid constitution. In: Gould RF, editor. Contact angle, wettability and adhesion. Washington, DC: ACS; 1964.
-
(1964)
Contact Angle, Wettability, and Adhesion
, vol.25
, pp. 1964
-
-
Dettre, R.H.1
Johnson, R.E.2
-
25
-
-
0015294671
-
The role of surface energy in thrombogenesis
-
Baier RE. The role of surface energy in thrombogenesis. Bull N Y Acad Med 1972;48:257-272.
-
(1972)
Bull N Y Acad Med
, vol.48
, pp. 257-272
-
-
Baier, R.E.1
-
27
-
-
0344028091
-
The spreading of liquids on low energy surfaces. I. PTFE
-
Fox HW, Zisman WA. The spreading of liquids on low energy surfaces. I. PTFE. J Colloid Sci 1950;514-531.
-
(1950)
J Colloid Sci
, pp. 514-531
-
-
Fox, H.W.1
Zisman, W.A.2
-
29
-
-
0036139479
-
Nanomechanical properties and morphology of thick polyurethane films under contact pressure and stretching
-
Amitay-Sadovsky, Ward EB, Somorjai GA, Komvopoulos K. Nanomechanical properties and morphology of thick polyurethane films under contact pressure and stretching. J Appl Phys 2002;91:375-381.
-
(2002)
J Appl Phys
, vol.91
, pp. 375-381
-
-
Amitay-Sadovsky1
Ward, E.B.2
Somorjai, G.A.3
Komvopoulos, K.4
-
32
-
-
10944222611
-
Surface biomedical effects of plasma on polyurethane
-
Mittal KL, editor. Utrecht: VSP
-
Li D, Zhao J. Surface biomedical effects of plasma on polyurethane. In: Mittal KL, editor. Polymer surface modification: relevance to adhesion. Utrecht: VSP; 1995. p 137-149.
-
(1995)
Polymer Surface Modification: Relevance to Adhesion
, pp. 137-149
-
-
Li, D.1
Zhao, J.2
|