메뉴 건너뛰기




Volumn 27, Issue 3, 2014, Pages 300-307

Second transcatheter aortic valve implantation for treatment of suboptimal function of previously implanted prosthesis: Review of the literature

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE REGURGITATION; ATRIOVENTRICULAR BLOCK; CARDIOVASCULAR MORTALITY; ECHOCARDIOGRAPHY; FEASIBILITY STUDY; FOLLOW UP; HEART MUSCLE CONDUCTION DISTURBANCE; HUMAN; INCIDENCE; MEDICAL DEVICE COMPLICATION; MORTALITY; PERCUTANEOUS AORTIC VALVE; PRIORITY JOURNAL; PROSTHESIS DYSFUNCTION; PROSTHESIS FAILURE; PROSTHESIS MALPOSITION; REVIEW; SYSTEMATIC REVIEW; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT FAILURE; TREATMENT INDICATION; TREATMENT OUTCOME; ADVERSE EFFECTS; AGED; AORTA VALVE; AORTIC VALVE INSUFFICIENCY; AORTIC VALVE STENOSIS; DEVICE FAILURE ANALYSIS; DEVICES; FEMALE; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; MALE; OUTCOME ASSESSMENT; POSTOPERATIVE COMPLICATIONS; PROCEDURES; PROSTHESIS DESIGN; REOPERATION; VERY ELDERLY;

EID: 84902083821     PISSN: 08964327     EISSN: 15408183     Source Type: Journal    
DOI: 10.1111/joic.12120     Document Type: Review
Times cited : (19)

References (49)
  • 1
    • 50849129574 scopus 로고    scopus 로고
    • First percutaneous transcatheter aortic valve-in-valve implant with three year follow-up
    • Ruiz CE, Laborde JC, Condado JF, et al. First percutaneous transcatheter aortic valve-in-valve implant with three year follow-up. Catheter Cardiovasc Interv 2008; 72: 143-148.
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 143-148
    • Ruiz, C.E.1    Laborde, J.C.2    Condado, J.F.3
  • 2
    • 84872143850 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document
    • Kappetein AP, Head SJ, Généreux P, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document. EuroIntervention 2012; 8: 782-795.
    • (2012) EuroIntervention , vol.8 , pp. 782-795
    • Kappetein, A.P.1    Head, S.J.2    Généreux, P.3
  • 3
    • 79951985830 scopus 로고    scopus 로고
    • The valve-in-valve technique for treatment of aortic bioprosthesis malposition: An analysis of incidence and 1-year clinical outcomes from the Italian CoreValve Registry
    • Ussia GP, Barbanti M, Ramondo A, et al. The valve-in-valve technique for treatment of aortic bioprosthesis malposition: An analysis of incidence and 1-year clinical outcomes from the Italian CoreValve Registry. J Am Coll Cardiol 2011; 57: 1062-1068.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1062-1068
    • Ussia, G.P.1    Barbanti, M.2    Ramondo, A.3
  • 4
    • 84862865272 scopus 로고    scopus 로고
    • Procedural and clinical outcomes of the valve-in-valve technique for severe aortic insufficiency after balloon-expandable transcatheter aortic valve replacement
    • Giri J, Bortnick AE, Wallen T, et al. Procedural and clinical outcomes of the valve-in-valve technique for severe aortic insufficiency after balloon-expandable transcatheter aortic valve replacement. Catheter Cardiovasc Interv 2012; 80: 139-147.
    • (2012) Catheter Cardiovasc Interv , vol.80 , pp. 139-147
    • Giri, J.1    Bortnick, A.E.2    Wallen, T.3
  • 5
    • 84861533894 scopus 로고    scopus 로고
    • Transcatheter valve-in-valve implantation for failed balloon-expandable transcatheter aortic valves
    • Toggweiler S, Wood DA, Rodés-Cabau J, et al. Transcatheter valve-in-valve implantation for failed balloon-expandable transcatheter aortic valves. J Am Coll Cardiol Interv 2012; 5: 571-577.
    • (2012) J Am Coll Cardiol Interv , vol.5 , pp. 571-577
    • Toggweiler, S.1    Wood, D.A.2    Rodés-Cabau, J.3
  • 6
    • 84855707905 scopus 로고    scopus 로고
    • Transapical aortic valve implantation: Incidence and predictors of paravalvular leakage and transvalvular regurgitation in a series of 358 patients
    • Unbehaun A, Pasic M, Dreysse S, et al. Transapical aortic valve implantation: Incidence and predictors of paravalvular leakage and transvalvular regurgitation in a series of 358 patients. J Am Coll Cardiol 2012; 59: 211-221.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 211-221
    • Unbehaun, A.1    Pasic, M.2    Dreysse, S.3
  • 7
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • Tamburino C, Capodanno D, Ramondo A, et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 2011; 123: 299-308.
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 8
    • 77954621513 scopus 로고    scopus 로고
    • Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • Thomas M, Schymik G, Walther T, et al. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 2010; 122: 62-69.
    • (2010) Circulation , vol.122 , pp. 62-69
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 9
    • 84880609872 scopus 로고    scopus 로고
    • Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: A study of multiple valve implants in the U. S. PARTNER Trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve)
    • Makkar RR, Jilaihawi H, Chakravarty T, et al. Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: A study of multiple valve implants in the U. S. PARTNER Trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve). J Am Coll Cardiol 2013; 62: 418-430.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 418-430
    • Makkar, R.R.1    Jilaihawi, H.2    Chakravarty, T.3
  • 10
    • 80053949735 scopus 로고    scopus 로고
    • Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients
    • Lange R, Bleiziffer S, Piazza N, et al. Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg 2011; 40: 1105-1113.
    • (2011) Eur J Cardiothorac Surg , vol.40 , pp. 1105-1113
    • Lange, R.1    Bleiziffer, S.2    Piazza, N.3
  • 11
    • 81855224743 scopus 로고    scopus 로고
    • Performance of valve-in-valve for severe para-prosthetic leaks due to inadequate transcatheter aortic valve implantation
    • Napodano M, Gasparetto V, Tarantini G, et al. Performance of valve-in-valve for severe para-prosthetic leaks due to inadequate transcatheter aortic valve implantation. Catheter Cardiovasc Interv 2011; 78: 996-1003.
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 996-1003
    • Napodano, M.1    Gasparetto, V.2    Tarantini, G.3
  • 12
    • 84856460597 scopus 로고    scopus 로고
    • Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation
    • Takagi K, Latib A, Al-Lamee R, et al. Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation. Catheter Cardiovasc Interv 2011; 78: 432-443.
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 432-443
    • Takagi, K.1    Latib, A.2    Al-Lamee, R.3
  • 13
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 2011; 364: 2187-2198.
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 14
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    • Abdel-Wahab M, Zahn R, Horack M, et al. Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart 2011; 97: 899-906.
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 15
    • 65549146926 scopus 로고    scopus 로고
    • Implantation of two self-expanding aortic bioprosthetic valves during the same procedure-Insights into valve-in-valve implantation ("Russian doll concept")
    • Piazza N, Schultz C, de Jaegere PP, et al. Implantation of two self-expanding aortic bioprosthetic valves during the same procedure-Insights into valve-in-valve implantation ("Russian doll concept"). Catheter Cardiovasc Interv 2009; 73: 530-539.
    • (2009) Catheter Cardiovasc Interv , vol.73 , pp. 530-539
    • Piazza, N.1    Schultz, C.2    De Jaegere, P.P.3
  • 16
    • 84863724848 scopus 로고    scopus 로고
    • Interventional options for severe aortic regurgitation after transcatheter aortic valve implantation: Balloons, snares, valve-in-valve
    • Eggebrecht H, Doss M, Schmermund A, et al. Interventional options for severe aortic regurgitation after transcatheter aortic valve implantation: Balloons, snares, valve-in-valve. Clin Res Cardiol 2012; 101: 503-507.
    • (2012) Clin Res Cardiol , vol.101 , pp. 503-507
    • Eggebrecht, H.1    Doss, M.2    Schmermund, A.3
  • 17
    • 84869164807 scopus 로고    scopus 로고
    • Second valve implantation for the treatment of a malpositioned transcatheter aortic valve
    • Guérios ÊE, Gloekler S, Pilgrim T, et al. Second valve implantation for the treatment of a malpositioned transcatheter aortic valve. J Invasive Cardiol 2012; 24: 457-462.
    • (2012) J Invasive Cardiol , vol.24 , pp. 457-462
    • Guérios, Ê.1    Gloekler, S.2    Pilgrim, T.3
  • 18
    • 77956839815 scopus 로고    scopus 로고
    • Management of implant failure during transcatheter aortic valve implantation
    • Ussia GP, Barbanti M, Immè S, et al. Management of implant failure during transcatheter aortic valve implantation. Catheter Cardiovasc Interv 2010; 76: 440-449.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 440-449
    • Ussia, G.P.1    Barbanti, M.2    Immè, S.3
  • 19
    • 65549143852 scopus 로고    scopus 로고
    • The valve-in-valve technique: Transcatheter treatment of aortic bioprothesis malposition
    • Ussia GP, Mulè M, Tamburino C., The valve-in-valve technique: Transcatheter treatment of aortic bioprothesis malposition. Catheter Cardiovasc Interv 2009; 73: 713-716.
    • (2009) Catheter Cardiovasc Interv , vol.73 , pp. 713-716
    • Ussia, G.P.1    Mulè, M.2    Tamburino, C.3
  • 20
    • 79958176452 scopus 로고    scopus 로고
    • Mechanisms treatment and course of paravalvular aortic regurgitation after percutaneous implantation of the CoreValve aortic prosthesis
    • Muñoz-García AJ, Alonso-Briales JH, Jiménez-Navarro MF, et al. Mechanisms. treatment and course of paravalvular aortic regurgitation after percutaneous implantation of the CoreValve aortic prosthesis. Int J Cardiol 2011; 149: 389-392.
    • (2011) Int J Cardiol , vol.149 , pp. 389-392
    • Muñoz-García, A.J.1    Alonso-Briales, J.H.2    Jiménez-Navarro, M.F.3
  • 21
    • 84868193971 scopus 로고    scopus 로고
    • Long-term outcome of patients with moderate and severe prosthetic aortic valve regurgitation after transcatheter aortic valve implantation
    • Gotzmann M, Korten M, Bojara W, et al. Long-term outcome of patients with moderate and severe prosthetic aortic valve regurgitation after transcatheter aortic valve implantation. Am J Cardiol 2012; 110: 1500-1506.
    • (2012) Am J Cardiol , vol.110 , pp. 1500-1506
    • Gotzmann, M.1    Korten, M.2    Bojara, W.3
  • 22
    • 79958019713 scopus 로고    scopus 로고
    • A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation
    • Kempfert J, Rastan AJ, Schuler G, et al. A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation. Eur J Cardiothorac Surg 2011; 40: 56-60.
    • (2011) Eur J Cardiothorac Surg , vol.40 , pp. 56-60
    • Kempfert, J.1    Rastan, A.J.2    Schuler, G.3
  • 23
    • 67650088413 scopus 로고    scopus 로고
    • Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis
    • Himbert D, Descoutures F, Al-Attar N, et al. Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis. J Am Coll Cardiol 2009; 54: 303-311.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 303-311
    • Himbert, D.1    Descoutures, F.2    Al-Attar, N.3
  • 24
    • 58149214506 scopus 로고    scopus 로고
    • Prevention and management of transcatheter balloon-expandable aortic valve malposition
    • Al Ali AM, Altwegg L, Horlick EM, et al. Prevention and management of transcatheter balloon-expandable aortic valve malposition. Catheter Cardiovasc Interv 2008; 72: 573-578.
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 573-578
    • Al Ali, A.M.1    Altwegg, L.2    Horlick, E.M.3
  • 25
    • 84862838372 scopus 로고    scopus 로고
    • Valvular leak after transcatheter aortic valve implantation: A clinician update on epidemiology, pathophysiology and clinical implications
    • Tarantini G, Gasparetto V, Napodano M, et al. Valvular leak after transcatheter aortic valve implantation: A clinician update on epidemiology, pathophysiology and clinical implications. Am J Cardiovasc Dis 2011; 1: 312-320.
    • (2011) Am J Cardiovasc Dis , vol.1 , pp. 312-320
    • Tarantini, G.1    Gasparetto, V.2    Napodano, M.3
  • 26
    • 72249096323 scopus 로고    scopus 로고
    • Valve-in-valve" for the treatment of paravalvular leaks following transcatheter aortic valve implantation
    • Rodés-Cabau J, Dumont E, Doyle D., " Valve-in-valve" for the treatment of paravalvular leaks following transcatheter aortic valve implantation. Catheter Cardiovasc Interv 2009; 74: 1116-1119.
    • (2009) Catheter Cardiovasc Interv , vol.74 , pp. 1116-1119
    • Rodés-Cabau, J.1    Dumont, E.2    Doyle, D.3
  • 27
    • 84901001169 scopus 로고    scopus 로고
    • Rescue "valve in valve" implantation after late onset CoreValve cusp rupture leading to acute massive aortic insufficiency
    • May 3 (Epub ahead of print). doi: 10.1002/ccd.23155
    • Pagnotta P, Ferrante G, Presbitero P., Rescue "valve in valve" implantation after late onset CoreValve cusp rupture leading to acute massive aortic insufficiency. Catheter Cardiovasc Interv 2011; May 3 (Epub ahead of print). doi: 10.1002/ccd.23155
    • (2011) Catheter Cardiovasc Interv
    • Pagnotta, P.1    Ferrante, G.2    Presbitero, P.3
  • 28
    • 80052784614 scopus 로고    scopus 로고
    • Management of aortic valve dysfunction after transapical approach using the technique "valve after valve
    • Miranda-Balbuena N, Araji OA, Gutierrez-Martín MÁ, et al. Management of aortic valve dysfunction after transapical approach using the technique "valve after valve ". Ann Thorac Surg 2011; 92: 1102-1104.
    • (2011) Ann Thorac Surg , vol.92 , pp. 1102-1104
    • Miranda-Balbuena, N.1    Araji, O.A.2    Gutierrez-Martín, M.3
  • 29
    • 54549085618 scopus 로고    scopus 로고
    • Feasibility and initial results of percutaneous aortic valve implantation including selection of the transfemoral or transapical approach in patients with severe aortic stenosis
    • Rodés-Cabau J, Dumont E, De LaRochellière R, et al. Feasibility and initial results of percutaneous aortic valve implantation including selection of the transfemoral or transapical approach in patients with severe aortic stenosis. Am J Cardiol 2008; 102: 1240-1246.
    • (2008) Am J Cardiol , vol.102 , pp. 1240-1246
    • Rodés-Cabau, J.1    Dumont, E.2    De Larochellière, R.3
  • 30
    • 79952536191 scopus 로고    scopus 로고
    • Severe intraprosthetic regurgitation by immobile leaflet after trans-catheter aortic valve implantation
    • Al-Attar N, Himbert D, Vahanian A, et al. Severe intraprosthetic regurgitation by immobile leaflet after trans-catheter aortic valve implantation. Eur J Cardiothorac Surg 2011; 39: 591-592.
    • (2011) Eur J Cardiothorac Surg , vol.39 , pp. 591-592
    • Al-Attar, N.1    Himbert, D.2    Vahanian, A.3
  • 31
    • 64149130537 scopus 로고    scopus 로고
    • Percutaneous valve-in-valve procedure for severe paravalvular regurgitation in aortic bioprosthesis
    • Ng AC, van der Kley F, Delgado V, et al. Percutaneous valve-in-valve procedure for severe paravalvular regurgitation in aortic bioprosthesis. J Am Coll Cardiol Imaging 2009; 2: 522-523.
    • (2009) J Am Coll Cardiol Imaging , vol.2 , pp. 522-523
    • Ng, A.C.1    Van Der Kley, F.2    Delgado, V.3
  • 32
    • 77950862505 scopus 로고    scopus 로고
    • Severe aortic regurgitation after percutaneous transcatheter aortic valve implantation: On the importance to clarify the underlying pathophysiology
    • Zahn R, Schiele R, Kilkowski C, et al. Severe aortic regurgitation after percutaneous transcatheter aortic valve implantation: On the importance to clarify the underlying pathophysiology. Clin Res Cardiol 2010; 99: 193-197.
    • (2010) Clin Res Cardiol , vol.99 , pp. 193-197
    • Zahn, R.1    Schiele, R.2    Kilkowski, C.3
  • 33
    • 77956619173 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation complicated by acute structural valve failure requiring immediate valve in valve implantation
    • Pasupati S, Puri A, Devlin G, et al. Transcatheter aortic valve implantation complicated by acute structural valve failure requiring immediate valve in valve implantation. Heart Lung Circ 2010; 19: 611-614.
    • (2010) Heart Lung Circ , vol.19 , pp. 611-614
    • Pasupati, S.1    Puri, A.2    Devlin, G.3
  • 34
    • 84882434702 scopus 로고    scopus 로고
    • Valve-in-valve implantation for aortic annular rupture complicating transcatheter aortic valve replacement (TAVR)
    • Yu Y, Vallely M, Ng MK., Valve-in-valve implantation for aortic annular rupture complicating transcatheter aortic valve replacement (TAVR). J Invasive Cardiol 2013; 25: 409-410.
    • (2013) J Invasive Cardiol , vol.25 , pp. 409-410
    • Yu, Y.1    Vallely, M.2    Ng, M.K.3
  • 35
    • 77649208371 scopus 로고    scopus 로고
    • Interventional rescue strategy after malpositioning of a percutaneous aortic valve
    • Conradi L, Treede H, Reichenspurner H., Interventional rescue strategy after malpositioning of a percutaneous aortic valve. Heart 2010; 96: 407.
    • (2010) Heart , vol.96 , pp. 407
    • Conradi, L.1    Treede, H.2    Reichenspurner, H.3
  • 36
    • 79953835907 scopus 로고    scopus 로고
    • Correction of aortic regurgitation after transcatheter aortic valve implantation of the Medtronic CoreValve™ prosthesis due to a too-low implantation using transcatheter repositioning
    • Zahn R, Schiele R, Kilkowski C, et al. Correction of aortic regurgitation after transcatheter aortic valve implantation of the Medtronic CoreValve™ prosthesis due to a too-low implantation using transcatheter repositioning. J Heart Valve Dis 2011; 20: 64-69.
    • (2011) J Heart Valve Dis , vol.20 , pp. 64-69
    • Zahn, R.1    Schiele, R.2    Kilkowski, C.3
  • 37
    • 84871292882 scopus 로고    scopus 로고
    • Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation
    • Hayashida K, Bouvier E, Lefèvre T, et al. Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation. EuroIntervention 2012; 8: 546-555.
    • (2012) EuroIntervention , vol.8 , pp. 546-555
    • Hayashida, K.1    Bouvier, E.2    Lefèvre, T.3
  • 38
    • 58249137913 scopus 로고    scopus 로고
    • Severe valvular regurgitation and late prosthesis embolization after percutaneous aortic valve implantation
    • Clavel MA, Dumont E, Pibarot P, et al. Severe valvular regurgitation and late prosthesis embolization after percutaneous aortic valve implantation. Ann Thorac Surg 2009; 87: 618-621.
    • (2009) Ann Thorac Surg , vol.87 , pp. 618-621
    • Clavel, M.A.1    Dumont, E.2    Pibarot, P.3
  • 39
    • 84861534743 scopus 로고    scopus 로고
    • Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve
    • Nombela-Franco L, Rodés-Cabau J, DeLarochellière R, et al. Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve. J Am Coll Cardiol Intv 2012; 5: 499-512.
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 499-512
    • Nombela-Franco, L.1    Rodés-Cabau, J.2    Delarochellière, R.3
  • 40
    • 84858652989 scopus 로고    scopus 로고
    • Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation
    • Sinning JM, Hammerstingl C, Vasa-Nicotera M, et al. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol 2012; 59: 1134-1141.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1134-1141
    • Sinning, J.M.1    Hammerstingl, C.2    Vasa-Nicotera, M.3
  • 41
    • 84865324941 scopus 로고    scopus 로고
    • Impact of paravalvular leakage on outcome in patients after transcatheter aortic valve implantation
    • Vasa-Nicotera M, Sinning JM, Chin D, et al. Impact of paravalvular leakage on outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol Intv 2012; 5: 858-865.
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 858-865
    • Vasa-Nicotera, M.1    Sinning, J.M.2    Chin, D.3
  • 42
    • 78049477851 scopus 로고    scopus 로고
    • Bail out" procedures for malpositioning of aortic valve prosthesis (CoreValve)
    • Vavouranakis M, Vrachatis DA, Toutouzas KP, et al. " Bail out" procedures for malpositioning of aortic valve prosthesis (CoreValve). Int J Cardiol 2010; 145: 154-155.
    • (2010) Int J Cardiol , vol.145 , pp. 154-155
    • Vavouranakis, M.1    Vrachatis, D.A.2    Toutouzas, K.P.3
  • 43
    • 74049090167 scopus 로고    scopus 로고
    • Post-implantation repositioning of the CoreValve percutaneous aortic valve
    • Latib A, Michev I, Laborde JC, et al. Post-implantation repositioning of the CoreValve percutaneous aortic valve. J Am Coll Cardiol Interv 2010; 3: 119-121.
    • (2010) J Am Coll Cardiol Interv , vol.3 , pp. 119-121
    • Latib, A.1    Michev, I.2    Laborde, J.C.3
  • 44
    • 60849121992 scopus 로고    scopus 로고
    • Progress and current status of percutaneous aortic valve replacement: Results of three device generations of the CoreValve Revalving system
    • Grube E, Buellesfeld L, Mueller R, et al. Progress and current status of percutaneous aortic valve replacement: Results of three device generations of the CoreValve Revalving system. Circ Cardiovasc Interv 2008; 1: 167-175.
    • (2008) Circ Cardiovasc Interv , vol.1 , pp. 167-175
    • Grube, E.1    Buellesfeld, L.2    Mueller, R.3
  • 45
    • 84867314894 scopus 로고    scopus 로고
    • Interventional closure of paravalvular leakage after transcatheter aortic valve implantation
    • Sinning JM, Vasa-Nicotera M, Werner N, et al. Interventional closure of paravalvular leakage after transcatheter aortic valve implantation. Eur Heart J 2012; 33: 2498.
    • (2012) Eur Heart J , vol.33 , pp. 2498
    • Sinning, J.M.1    Vasa-Nicotera, M.2    Werner, N.3
  • 46
    • 84879329177 scopus 로고    scopus 로고
    • Device closure of paravalvular defects following transcatheter aortic valve replacement with the Edwards SAPIEN valve
    • May 14 (Epub ahead of print). doi: 10.1002/ccd.24477
    • Whisenant B, Jones K, Horton KD, et al. Device closure of paravalvular defects following transcatheter aortic valve replacement with the Edwards SAPIEN valve. Catheter Cardiovasc Interv 2012; May 14 (Epub ahead of print). doi: 10.1002/ccd.24477
    • (2012) Catheter Cardiovasc Interv
    • Whisenant, B.1    Jones, K.2    Horton, K.D.3
  • 47
    • 84857776345 scopus 로고    scopus 로고
    • Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: Initial single centre experience
    • Czerwińska K, Hryniewiecki T, Orȩziak A, et al. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: Initial single centre experience. Kardiol Pol 2012; 70: 121-128.
    • (2012) Kardiol Pol , vol.70 , pp. 121-128
    • Czerwińska, K.1    Hryniewiecki, T.2    Orȩziak, A.3
  • 48
    • 79951963644 scopus 로고    scopus 로고
    • Outcome of patients after transcatheter aortic valve embolization
    • Tay EL, Gurvitch R, Wijeysinghe N, et al. Outcome of patients after transcatheter aortic valve embolization. J Am Coll Cardiol Interv 2011; 4: 228-234.
    • (2011) J Am Coll Cardiol Interv , vol.4 , pp. 228-234
    • Tay, E.L.1    Gurvitch, R.2    Wijeysinghe, N.3
  • 49
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • Kodali SK, Williams MR, Smith CR, et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 2012; 366: 1686-1695.
    • (2012) N Engl J Med , vol.366 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.