메뉴 건너뛰기




Volumn 70, Issue 2, 2012, Pages 121-128

Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: Initial single centre experience

Author keywords

Aortic stenosis; Conduction disturbances; CoreValve bioprosthesis; Permanent cardiac pacing; TAVI

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CLINICAL ARTICLE; COMPLETE HEART BLOCK; COREVALVE AORTIC BIOPROSTHESIS; ELECTROCARDIOGRAM; FEMALE; HEART MUSCLE CONDUCTION DISTURBANCE; HEART PACING; HEART VALVE BIOPROSTHESIS; HUMAN; MALE; QRS COMPLEX; RISK FACTOR; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT INDICATION; VALVULOPLASTY;

EID: 84857776345     PISSN: 00229032     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (14)
  • 2
    • 78349255551 scopus 로고    scopus 로고
    • Predictors for permanent pacing after transcatheter aortic valve implantation
    • Haworth P, Behan M, Khawaja M et al. Predictors for permanent pacing after transcatheter aortic valve implantation. Catheter Cardiovasc Interv, 2010; 76: 751-756.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 751-756
    • Haworth, P.1    Behan, M.2    Khawaja, M.3
  • 3
    • 77649145354 scopus 로고    scopus 로고
    • Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis
    • Baan J, Yong ZY, Koch KT et al. Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis. Am Heart J, 2010; 159: 497-503.
    • (2010) Am Heart J , vol.159 , pp. 497-503
    • Baan, J.1    Yong, Z.Y.2    Koch, K.T.3
  • 5
    • 0037420076 scopus 로고    scopus 로고
    • Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery
    • DOI 10.1016/S0735-1097(02)02926-1
    • Koplan BA, Stevenson WG, Epstein LM, Aranki SF, Maisel WH. Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery. J Am Coll Cardiol, 2003; 41: 795-801. (Pubitemid 36308388)
    • (2003) Journal of the American College of Cardiology , vol.41 , Issue.5 , pp. 795-801
    • Koplan, B.A.1    Stevenson, W.G.2    Epstein, L.M.3    Aranki, S.F.4    Maisel, W.H.5
  • 6
    • 77955617014 scopus 로고    scopus 로고
    • Predictors for new-onset complete heart block after transcatheter aortic valve implantation
    • Bleiziffer S, Ruge H, Hörer J et al. Predictors for new-onset complete heart block after transcatheter aortic valve implantation. J Am Coll Cardiol Cardiovasc Intervent, 2010; 3: 524-530.
    • (2010) J Am Coll Cardiol Cardiovasc Intervent , vol.3 , pp. 524-530
    • Bleiziffer, S.1    Ruge, H.2    Hörer, J.3
  • 7
    • 21044456170 scopus 로고    scopus 로고
    • The clinical development of percutaneous heart valve technology: A position statement of the society of thoracic surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA)
    • Vassiliades TA, Block PC, Cohn LH et al. The clinical development of percutaneous heart valve technology: a position statement of the society of thoracic surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA). J Am Coll Cardiol, 2005; 45: 1554-1560.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1554-1560
    • Vassiliades, T.A.1    Block, P.C.2    Cohn, L.H.3
  • 8
    • 45649083670 scopus 로고    scopus 로고
    • Transcatheter valve implantation for patients with aortic stenosis: A position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
    • Vahanian A, Alfieri OR, Al-Attar N et al. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur J Cardiothorac Surg, 2008; 34: 1-8.
    • (2008) Eur J Cardiothorac Surg , vol.34 , pp. 1-8
    • Vahanian, A.1    Alfieri, O.R.2    Al-Attar, N.3
  • 9
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • org. 10:1056/NEJMoa1008232.
    • Leon MB, Smith CR, Mack M et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. NEJM, org. 2010; 10:1056/NEJMoa1008232.
    • (2010) NEJM
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 10
    • 77954621513 scopus 로고    scopus 로고
    • Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve
    • Thomas M, Schymik G, Walther T et al. Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: a European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve. Circulation, 2010; 122: 62-69.
    • (2010) Circulation , vol.122 , pp. 62-69
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 11
    • 64349084245 scopus 로고    scopus 로고
    • Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis
    • Jilaihawi H, Chin D, Vasa-Nicotera M et al. Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis. Am Heart J, 2009; 157: 860-866.
    • (2009) Am Heart J , vol.157 , pp. 860-866
    • Jilaihawi, H.1    Chin, D.2    Vasa-Nicotera, M.3
  • 12
    • 77955927048 scopus 로고    scopus 로고
    • Frequency of conduction disturbances after transcatheter implantation of an Edwards Sapien aortic valve prosthesis
    • Godin M, Eltchaninoff H, Furuta A et al. Frequency of conduction disturbances after transcatheter implantation of an Edwards Sapien aortic valve prosthesis. Am J Cardiol, 2010; 106: 707-712.
    • (2010) Am J Cardiol , vol.106 , pp. 707-712
    • Godin, M.1    Eltchaninoff, H.2    Furuta, A.3
  • 13
    • 79952738239 scopus 로고    scopus 로고
    • Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation. Incidence and contributing factors (the UK CoreValve Collaborative)
    • Khawaja M, Rajani R, Cook A et al. Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation. Incidence and contributing factors (the UK CoreValve Collaborative). Circulation, 2011; 123: 951-960.
    • (2011) Circulation , vol.123 , pp. 951-960
    • Khawaja, M.1    Rajani, R.2    Cook, A.3
  • 14
    • 78651469380 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry
    • Eltchaninoff H, Prat A, Gilard M et al. Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Eur Heart J, 2011; 32: 191-197.
    • (2011) Eur Heart J , vol.32 , pp. 191-197
    • Eltchaninoff, H.1    Prat, A.2    Gilard, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.