메뉴 건너뛰기




Volumn 16, Issue 4, 2014, Pages 227-233

Development and evaluation of a rapid PCR method for the PowerPlex®S5 system for forensic DNA profiling

Author keywords

D18S51; D8S1179; FGA; Rapid PCR; Short tandem repeats; TH01

Indexed keywords

ARTICLE; CONTROLLED STUDY; DNA FINGERPRINTING; EVALUATION STUDY; FEMALE; FORENSIC GENETICS; GENE AMPLIFICATION; GENE LOCUS; HUMAN; MALE; NUCLEOTIDE SEQUENCE; POLYMERASE CHAIN REACTION; POLYMERASE CHAIN REACTION SYSTEM; SENSITIVITY ANALYSIS; THERMAL CYCLER; GENETICS; PROCEDURES;

EID: 84902077141     PISSN: 13446223     EISSN: 18734162     Source Type: Journal    
DOI: 10.1016/j.legalmed.2014.04.003     Document Type: Article
Times cited : (5)

References (31)
  • 1
    • 70350514201 scopus 로고    scopus 로고
    • Fast multiplexed polymerase chain reaction for conventional and microfluidic short tandem repeat analysis
    • Giese H., Lam R., Selden R., Tan E. Fast multiplexed polymerase chain reaction for conventional and microfluidic short tandem repeat analysis. J Forensic Sci 2009, 54:1287-1296.
    • (2009) J Forensic Sci , vol.54 , pp. 1287-1296
    • Giese, H.1    Lam, R.2    Selden, R.3    Tan, E.4
  • 3
    • 31344464064 scopus 로고    scopus 로고
    • Fast extraction, amplification and analysis of genes from human blood
    • Zhang L., Dang F., Kaji N., Baba Y. Fast extraction, amplification and analysis of genes from human blood. J Chromatogr A 2006, 1106:175-180.
    • (2006) J Chromatogr A , vol.1106 , pp. 175-180
    • Zhang, L.1    Dang, F.2    Kaji, N.3    Baba, Y.4
  • 5
    • 84886750487 scopus 로고    scopus 로고
    • A 27-locus STR assay to meet all United States and European law enforcement agency standards
    • Schumm J.W., Gutierrez-Mateo C., Tan E., Selden R. A 27-locus STR assay to meet all United States and European law enforcement agency standards. J Forensic Sci 2013, 58:1584-1592.
    • (2013) J Forensic Sci , vol.58 , pp. 1584-1592
    • Schumm, J.W.1    Gutierrez-Mateo, C.2    Tan, E.3    Selden, R.4
  • 7
    • 56549096777 scopus 로고    scopus 로고
    • Demonstration of rapid multiplex PCR amplification involving 16 genetic loci
    • Vallone P., Hill C.R., Butler J.M. Demonstration of rapid multiplex PCR amplification involving 16 genetic loci. Forensic Sci Int Genet 2008, 3:42-45.
    • (2008) Forensic Sci Int Genet , vol.3 , pp. 42-45
    • Vallone, P.1    Hill, C.R.2    Butler, J.M.3
  • 9
    • 84862211436 scopus 로고    scopus 로고
    • Development of a fast PCR protocol enabling rapid generation of AmpFℓSTR®Identifiler®profiles for genotyping of human DNA
    • Foster A., Laurin N. Development of a fast PCR protocol enabling rapid generation of AmpFℓSTR®Identifiler®profiles for genotyping of human DNA. Invest Genet 2012, 3. http://dx.doi.org/10.1186/2041-2223-3-6.
    • (2012) Invest Genet , vol.3
    • Foster, A.1    Laurin, N.2
  • 10
    • 82655181300 scopus 로고    scopus 로고
    • Optimization and validation of a fast amplification protocol for AmpFℓSTR®Profiler Plus®for rapid human identification
    • Laurin N., Fregeau C. Optimization and validation of a fast amplification protocol for AmpFℓSTR®Profiler Plus®for rapid human identification. Forensic Sci Int Genet 2012, 6:47-57.
    • (2012) Forensic Sci Int Genet , vol.6 , pp. 47-57
    • Laurin, N.1    Fregeau, C.2
  • 12
    • 84857050594 scopus 로고    scopus 로고
    • A protocol for direct and rapid multiplex PCR amplification on forensically relevant samples
    • Verheij S., Harteveld J., Sijen T. A protocol for direct and rapid multiplex PCR amplification on forensically relevant samples. Forensic Sci Int Genet 2012, 6:167-175.
    • (2012) Forensic Sci Int Genet , vol.6 , pp. 167-175
    • Verheij, S.1    Harteveld, J.2    Sijen, T.3
  • 13
    • 84878640668 scopus 로고    scopus 로고
    • Rapid direct PCR for forensic genotyping in under 25min
    • Aboud M., Oh H.H., McCord B. Rapid direct PCR for forensic genotyping in under 25min. Electrophoresis 2013, 34:1539-1547.
    • (2013) Electrophoresis , vol.34 , pp. 1539-1547
    • Aboud, M.1    Oh, H.H.2    McCord, B.3
  • 14
    • 0034027659 scopus 로고    scopus 로고
    • Fast and type-specific analysis of Herpes Simplex Virus 1 and 2 by rapid PCR and fluorescence melting-curve-analysis
    • Schalasta G., Arents A., Schmid M., Braun R.W., Enders G. Fast and type-specific analysis of Herpes Simplex Virus 1 and 2 by rapid PCR and fluorescence melting-curve-analysis. Infection 2000, 28:85-91.
    • (2000) Infection , vol.28 , pp. 85-91
    • Schalasta, G.1    Arents, A.2    Schmid, M.3    Braun, R.W.4    Enders, G.5
  • 16
    • 84902111022 scopus 로고    scopus 로고
    • GlobalFiler™ Express PCR Amplification Kit User Guide, version dated 10/2012, Life Technologies, Carlsbad, CA.
    • GlobalFiler™ Express PCR Amplification Kit User Guide, version dated 10/2012, Life Technologies, Carlsbad, CA.
  • 17
    • 84902111023 scopus 로고    scopus 로고
    • PowerPlex®18D System Technical Manual, version dated 08/2012, Promega Corporation, Madison, WI.
    • PowerPlex®18D System Technical Manual, version dated 08/2012, Promega Corporation, Madison, WI.
  • 18
    • 84902111024 scopus 로고    scopus 로고
    • PowerPlex®Fusion System E Brochure version dated 09/2012, Promega Corporation, Madison, WI.
    • PowerPlex®Fusion System E Brochure version dated 09/2012, Promega Corporation, Madison, WI.
  • 20
    • 0025923821 scopus 로고
    • Chelex 100 as a medium for simple extraction of DNA for PCR-based typing from forensic material
    • Walsh P.S., Metzger D.A., Higuchi R. Chelex 100 as a medium for simple extraction of DNA for PCR-based typing from forensic material. BioTechniques 1991, 10:506-513.
    • (1991) BioTechniques , vol.10 , pp. 506-513
    • Walsh, P.S.1    Metzger, D.A.2    Higuchi, R.3
  • 22
    • 84902111025 scopus 로고    scopus 로고
    • SpeedSTAR™ HS DNA Polymerase Product Manual v1106Da_b, Takara Bio Inc., Madison, WI.
    • SpeedSTAR™ HS DNA Polymerase Product Manual v1106Da_b, Takara Bio Inc., Madison, WI.
  • 23
    • 84902111016 scopus 로고    scopus 로고
    • Platinum®Taq DNA Polymerase Manual, version dated 2010, Invitrogen, Carlsbad, CA
    • Platinum®Taq DNA Polymerase Manual, version dated 2010, Invitrogen, Carlsbad, CA.
  • 24
    • 84902111017 scopus 로고    scopus 로고
    • Qiagen®Fast Cycling PCR Handbook, version dated 10/2012, Qiagen, Valencia, CA.
    • Qiagen®Fast Cycling PCR Handbook, version dated 10/2012, Qiagen, Valencia, CA.
  • 25
    • 84902111008 scopus 로고    scopus 로고
    • PowerPlex®S5 System Technical Manual, version dated 08/2012, Promega Corporation, Madison, WI.
    • PowerPlex®S5 System Technical Manual, version dated 08/2012, Promega Corporation, Madison, WI.
  • 26
    • 33845909860 scopus 로고    scopus 로고
    • Run-specific limits of detection and quantitation for STR-based DNA testing
    • Gilder J.R., Doom T.E., Inman K., Krane D.E. Run-specific limits of detection and quantitation for STR-based DNA testing. J Forensic Sci 2007, 52:97-101.
    • (2007) J Forensic Sci , vol.52 , pp. 97-101
    • Gilder, J.R.1    Doom, T.E.2    Inman, K.3    Krane, D.E.4
  • 27
    • 84902111009 scopus 로고    scopus 로고
    • (accessed February 2014).
    • (accessed February 2014). https://www.promega.com/~/media/files/resources/validation%20guides/internal%20validation%20of%20autosomal%20str%20systems.pdf?la=en.
  • 28
    • 0034990151 scopus 로고    scopus 로고
    • Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples
    • Moretti T.R., Baumstark A.L., Defenbaugh D.A., Keys K.M., Smerick J.B., Budowle B. Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples. J Forensic Sci 2001, 46:647-660.
    • (2001) J Forensic Sci , vol.46 , pp. 647-660
    • Moretti, T.R.1    Baumstark, A.L.2    Defenbaugh, D.A.3    Keys, K.M.4    Smerick, J.B.5    Budowle, B.6
  • 29
    • 84902111010 scopus 로고    scopus 로고
    • AmpFℓSTR®Profiler Plus®PCR Amplification Kit User's Manual, version dated 03/2012, Applied Biosystems, Carlsbad, CA.
    • AmpFℓSTR®Profiler Plus®PCR Amplification Kit User's Manual, version dated 03/2012, Applied Biosystems, Carlsbad, CA.
  • 30
    • 69649098199 scopus 로고    scopus 로고
    • Validation of the AmpFℓSTR® MiniFiler PCR amplification kit for use in forensic casework
    • Luce C., Montpetit S., Gangitano D., O'Donnell P. Validation of the AmpFℓSTR® MiniFiler PCR amplification kit for use in forensic casework. J Forensic Sci 2009, 54:1046-1054.
    • (2009) J Forensic Sci , vol.54 , pp. 1046-1054
    • Luce, C.1    Montpetit, S.2    Gangitano, D.3    O'Donnell, P.4
  • 31
    • 0003405772 scopus 로고    scopus 로고
    • Elsevier Academic Press, Burlington
    • Butler J.M. Forensic DNA typing 2005, Elsevier Academic Press, Burlington. 2nd ed.
    • (2005) Forensic DNA typing
    • Butler, J.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.