메뉴 건너뛰기




Volumn 44, Issue 12, 2014, Pages 1370-1421

Online drinking water quality monitoring: Review on available and emerging technologies

Author keywords

Conductivity; pH; water quality monitoring sensors

Indexed keywords

ELECTRIC CONDUCTIVITY; PH; SENSORS; WATER DISTRIBUTION SYSTEMS; WATER QUALITY;

EID: 84901341282     PISSN: 10643389     EISSN: 15476537     Source Type: Journal    
DOI: 10.1080/10643389.2013.781936     Document Type: Review
Times cited : (120)

References (152)
  • 1
    • 0344305377 scopus 로고    scopus 로고
    • Probes and polymers for optical sensing of oxygen
    • Amao Y. (2003). Probes and polymers for optical sensing of oxygen. Microchimica Acta 143 1-12.
    • (2003) Microchimica Acta , vol.143 , pp. 1-12
    • Amao, Y.1
  • 3
    • 84901332192 scopus 로고
    • American Water Works Association Research Foundation (AWWARF) Japan Water Works Association (JWWA Instrumentation & computer integration of water utility operations Water Research Foundation Denver USA.
    • American Water Works Association Research Foundation (AWWARF) Japan Water Works Association (JWWA 1994Instrumentation & computer integration of water utility operations Water Research Foundation Denver USA.
    • (1994)
  • 5
    • 33746038131 scopus 로고    scopus 로고
    • Poly(vinyl alcohol)/poly(acrylic acid) hydrogels: FT-IR spectroscopic characterization of crosslinking reaction and work at transition point
    • Arndt K.F. Richter A. Ludwig S. Zimmermann J. Kressler D. and Kuckling D. (1999). Poly(vinyl alcohol)/poly(acrylic acid) hydrogels: FT-IR spectroscopic characterization of crosslinking reaction and work at transition point. Acta Polymerica 50(11-12) 383-390.
    • (1999) Acta Polymerica , vol.50 , Issue.11-12 , pp. 383-390
    • Arndt, K.F.1    Richter, A.2    Ludwig, S.3    Zimmermann, J.4    Kressler, D.5    Kuckling, D.6
  • 10
    • 84901294369 scopus 로고    scopus 로고
    • B́elisle (i n English) Portrait of the use of continuous monitoring of the quality of drinking water in the municipalities of Quebec (M. ATDR Thesis). Laval University Quebec (original document in French) Portrait de l'utilisation du suivi en continu de la qualit́e de l'eau potable dans les municipalit́es du Qúebec
    • B́elisle. (2011). Portrait de l'utilisation du suivi en continu de la qualit́e de l'eau potable dans les municipalit́es du Qúebec (i n English) Portrait of the use of continuous monitoring of the quality of drinking water in the municipalities of Quebec (M. ATDR Thesis). Laval University Quebec (original document in French
    • (2011)
  • 13
  • 15
    • 78149379950 scopus 로고    scopus 로고
    • Design and performance assessment of a plastic optical fibre-based sensor for measuring water turbidity
    • Bilro L. Prats S. Pinto J. Keizer J. and Nogueira R. (2010). Design and performance assessment of a plastic optical fibre-based sensor for measuring water turbidity. Measu rement Science & Technology 21 1-4.
    • (2010) Measu Rement Science & Technology , vol.21 , pp. 1-4
    • Bilro, L.1    Prats, S.2    Pinto, J.3    Keizer, J.4    Nogueira, R.5
  • 17
    • 3242734832 scopus 로고    scopus 로고
    • A wireless, remote query glucose biosensor based on a pH-sensitive polymer
    • DOI 10.1021/ac0498516
    • Cai Q. Zeng K. Ruan C. Desai T.A. and Grimes C.A. (2004). A wireless remote query glucose biosensor based on a pH-sensitive polymer. Analytical Chemistry 76 4038-4043. (Pubitemid 38943675)
    • (2004) Analytical Chemistry , vol.76 , Issue.14 , pp. 4038-4043
    • Cai, Q.1    Zeng, K.2    Ruan, C.3    Desai, T.A.4    Grimes, C.A.5
  • 20
    • 78049438652 scopus 로고    scopus 로고
    • Optical fiber dissolved oxygen sensor based on Pt(II) complex and core-shell silica nanoparticles incorporated with sol-gel matrix
    • Chu C. and Lo Y. (2010). Optical fiber dissolved oxygen sensor based on Pt(II) complex and core-shell silica nanoparticles incorporated with sol-gel matrix. Sensors and Actuators B: Chemical 151(1) 83-89.
    • (2010) Sensors and Actuators B: Chemical , vol.151 , Issue.1 , pp. 83-89
    • Chu, C.1    Lo, Y.2
  • 25
    • 0033888218 scopus 로고    scopus 로고
    • 2 intravascular catheter using optical monitoring and a dual concentric-flow microdialysis approach
    • DOI 10.1016/S0925-4005(99)00382-2
    • Cooney C. and Towe B. (2000). Miniaturized pH and pCO intravascular catheter using optical monitoring and a dual concentric-flow microdialysis approach. Sensors Actuators B: Chemical 62 177-181. (Pubitemid 30561130)
    • (2000) Sensors and Actuators, B: Chemical , vol.62 , Issue.3 , pp. 177-181
    • Cooney, C.G.1    Towe, B.C.2
  • 26
    • 33746932080 scopus 로고    scopus 로고
    • Current biosensor in drug discovery
    • Retrieved June 20 2011 from
    • Cooper M. (2006). Current biosensor in drug discovery. Drug Discovery World 68-82. Retrieved June 20 2011 from http://www.ddw-online.com/s/ drugdiscovery/p97058/current-biosensor-technologies-in-drug-discovery-summer- 2006.html
    • (2006) Drug Discovery World , pp. 68-82
    • Cooper, M.1
  • 29
    • 0028037497 scopus 로고
    • Direct measurement of chlorine penetration into biofilms during disinfection
    • de Beer D Srinivasan R. and Stewart P. (1994). Direct measurement of chlorine penetration into biofilms during disinfection. Applied and Environmental Microbiology 60 4339-4344. (Pubitemid 24370800)
    • (1994) Applied and Environmental Microbiology , vol.60 , Issue.12 , pp. 4339-4344
    • De Beer, D.1    Srinivasan, R.2    Stewart, P.S.3
  • 30
    • 84891430626 scopus 로고    scopus 로고
    • Department of Environment and Conservation. Retrieved November 30 2011 from
    • Department of Environment and Conservation. (2011). Real-time water quality monitoring program. Retrieved November 30 2011 from http://www.env.gov. nl. ca/env/waterres/rti/rtwq/index.html
    • (2011) Real-Time Water Quality Monitoring Program
  • 31
    • 0032131583 scopus 로고    scopus 로고
    • Integrated optical pH sensor using replicated chirped grating coupler sensor chips
    • D̈ubendorfe r J. Kunz R.E. Jobst G. Moser I. and Urban G. (1998). Integrated optical pH sensor using replicated chirped grating coupler sensor chips. Sensors and Actuators B 50(3) 210-219.
    • (1998) Sensors and Actuators B , vol.50 , Issue.3 , pp. 210-219
    • D̈ubendorfe, R.J.1    Kunz, R.E.2    Jobst, G.3    Moser, I.4    Urban, G.5
  • 32
    • 84901301141 scopus 로고    scopus 로고
    • Enviro nment Canada Retrieved September 2 2011 from Osoyoos lake water quality buoy-automated monitoring & surveillance station
    • Enviro nment Canada. (2011). Osoyoos lake water quality buoy-automated monitoring & surveillance station. Retrieved September 2 2011 from http://waterquality.ec.gc.ca/WaterQualityWeb2/DataOnline/RealTime/osoyoosBuoy. aspx#tphp
    • (2011)
  • 33
    • 79959274223 scopus 로고    scopus 로고
    • Federal-Provincial-Territorial Committee (FPTC) on Drinking Water of the Federal-Provincial-Territorial Committee on Health and the Environment . Retrieved May 3 2011 from
    • Federal-Provincial-Territorial Committee (FPTC) on Drinking Water of the Federal-Provincial-Territorial Committee on Health and the Environment. (2010). Guidelines for Canadian drinking water quality: Summary table. Retrieved May 3 2011 from http://www.hc-sc.gc.ca/ewh-semt/alt formats/hecs-sesc/pdf/pubs/water- eau/2010-sum guide-res recom/sum guideres recom-eng.pdf
    • (2010) Guidelines for Canadian Drinking Water Quality: Summary Table
  • 34
    • 0033677505 scopus 로고    scopus 로고
    • Early warning systems for hazardous b iological agents in potable water
    • Foran J.E. and Brosnan T. (2000). Early warning systems for hazardous b iological agents in potable water. Environmental Health Perspectives 108(10) 993.
    • (2000) Environmental Health Perspectives , vol.108 , Issue.10 , pp. 993
    • Foran, J.E.1    Brosnan, T.2
  • 35
    • 0034478906 scopus 로고    scopus 로고
    • New Non-External Field Inductive Conductivity Sensor (NXIC) for long term deployments in biologically active regions
    • Fougere A. (2000). New non-external field inductive conductivity sensor (NXIC) for long term deployments in biologically acti ve regions. Proceedings of OCEANS MTS/IEEE Conference Exhibition 623-630. (Pubitemid 32133873)
    • (2000) Oceans Conference Record (IEEE) , vol.1 , pp. 623-630
    • Fougere Alan, J.1
  • 36
    • 0003061012 scopus 로고
    • Oxygen probe based on tetrakis (alkylamino) ethylene chemiluminescence
    • Freeman T.M. and Seitz W.R. (1981). Oxygen probe based on tetrakis (alkylamino) ethylene chemiluminescence. Analytical Chemistry 53 98-102.
    • (1981) Analytical Chemistry , vol.53 , pp. 98-102
    • Freeman, T.M.1    Seitz, W.R.2
  • 40
    • 79958840721 scopus 로고    scopus 로고
    • Optical dissolved oxygen sensor utilizing molybdenum chloride cluster phosphorescence
    • Ghosh R.N. Askeland P.A. Kramer S. and Loloee R. (2011). Optical dissolved oxygen sensor utilizing molybdenum chloride cluster phosphorescence. Applied Physics Letters 98(22) 221103.
    • (2011) Applied Physics Letters , vol.98 , Issue.22 , pp. 221103
    • Ghosh, R.N.1    Askeland, P.A.2    Kramer, S.3    Loloee, R.4
  • 43
    • 0031269975 scopus 로고    scopus 로고
    • A sol-gel based fiber optic sensor for local blood pH measurements
    • PII S0925400597002633
    • Grant S. and Glass R. (1997). A sol-gel based fibre optic sensor for local blood pH measurements. Sensors Actuators B: Chemical 45 35-42. (Pubitemid 127433045)
    • (1997) Sensors and Actuators, B: Chemical , vol.45 , Issue.1 , pp. 35-42
    • Grant, S.A.1    Glass, R.S.2
  • 44
    • 77749340332 scopus 로고    scopus 로고
    • Assessing biological stability of drink ing water without disinfectant residuals in a full-scale water supply system
    • Hammes F. Berger C. K̈oster O. and Egli T. (2010). Assessing biological stability of drink ing water without disinfectant residuals in a full-scale water supply system. Journal of Water Supply: Research and Technology-Aqua 59 31-40.
    • (2010) Journal of Water Supply: Research and Technology-Aqua , vol.59 , pp. 31-40
    • Hammes, F.1    Berger, C.2    K̈oster, O.3    Egli, T.4
  • 45
    • 37449010517 scopus 로고    scopus 로고
    • Flowcytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes
    • Hammes F. Berney M. Wang Y. Vital M. K̈oster O. and Egli T. 2008 Flowcytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes Water Research 42 269-277.
    • (2008) Water Research , vol.42 , pp. 269-277
    • Hammes, F.1    Berney, M.2    Wang, Y.3    Vital, M.4    K̈oster, O.5    Egli, T.6
  • 46
    • 77953479063 scopus 로고    scopus 로고
    • Cytometric methods for measuring bacteria in water: Advantages pitfalls and applications
    • Hammes F. and Egli T. (2010). Cytometric methods for measuring bacteria in water: Advantages pitfalls and applications. Analytical and Bioanalytical Chemistry 397 1083-1095.
    • (2010) Analytical and Bioanalytical Chemistry , vol.397 , pp. 1083-1095
    • Hammes, F.1    Egli, T.2
  • 47
    • 0036859561 scopus 로고    scopus 로고
    • Constant-volume hydrogel osmometer: A new device concept for miniature biosensors
    • DOI 10.1021/bm0255894
    • Han I.S. Han M.H. Kim J. Lew S. Lee Y.J. Horkay F. and Magda J.J. (2002). Constant-volume hydrogel osmometer: A new device concept for miniature biosensors. Biomacromolecules 3 1271-1275. (Pubitemid 35423025)
    • (2002) Biomacromolecules , vol.3 , Issue.6 , pp. 1271-1275
    • Han, I.S.1    Han, M.-H.2    Kim, J.3    Lew, S.4    Lee, Y.J.5    Horkay, F.6    Magda, J.J.7
  • 48
    • 0026985052 scopus 로고
    • An analysis of low-level turbidity measurements management and operations
    • Hart V.S. Johnson C.E. and Letterman R.D. (1992 ). An analysis of low-level turbidity measurements management and operations. Journal of AWWA 84(12) 40-45.
    • (1992) Journal of AWWA , vol.84 , Issue.12 , pp. 40-45
    • Hart, V.S.1    Johnson, C.E.2    Letterman, R.D.3
  • 49
    • 77957943773 scopus 로고    scopus 로고
    • Review of sensor placement strategies for contamination warn ing systems in drinking water distribution systems
    • Hart W. and Murray R. (2010). Review of sensor placement strategies for contamination warn ing systems in drinking water distribution systems. Journal of Water Resource Planning and Management 136(6) 611-619.
    • (2010) Journal of Water Resource Planning and Management , vol.136 , Issue.6 , pp. 611-619
    • Hart, W.1    Murray, R.2
  • 50
    • 33745250444 scopus 로고    scopus 로고
    • Safeguarding the security of public water supplies using early warning systems: A brief review
    • Hasan J. States S. and Deininger R. (2004). Safeguarding the security of public water supplies using early warning systems: A brief review. Journal of Contemporary Water Research and Education 129 27-33.
    • (2004) Journal of Contemporary Water Research and Education , vol.129 , pp. 27-33
    • Hasan, J.1    States, S.2    Deininger, R.3
  • 51
    • 66249132862 scopus 로고    scopus 로고
    • Health Canada. Retrieved October 18 2011 from
    • Health Canada. (2009). Guidelines for Canadian drinking water quality: Chlorine. Retrieved October 18 2011 from http://www.hc-sc.gc.ca/ewh-semt/alt formats/hecs-sesc/pdf/pubs/water-eau/chlorine-chlore/tech doc chlor-eng.pdf
    • (2009) Guidelines for Canadian Drinking Water Quality: Chlorine
  • 53
    • 4344633095 scopus 로고    scopus 로고
    • Study of chemically induced pressure generation of hydrogels under isochoric conditions using a microfabricated device
    • Herber S. Eijkel J. Olthuis W. Bergveld P. and van den Berg A. (2004). Study of chemically induced pressure generation of hydrogels under isochoric conditions using a microfabricated device. Journal of Chemical Physics 121(6) 2746-2751.
    • (2004) Journal of Chemical Physics , vol.121 , Issue.6 , pp. 2746-2751
    • Herber, S.1    Eijkel, J.2    Olthuis, W.3    Bergveld, P.4    Van Den Berg, A.5
  • 55
    • 0142125819 scopus 로고    scopus 로고
    • Ultrasensitive biomens sensors based on microcantilevers patterned with environmentally responsive hydrogels
    • DOI 10.1023/A:1025786023595
    • Hilt J.Z. Gupta A.M. Bashir R. and Peppas N.A. (2003). Ultrasensitive biomems sensors based on microcantilevers patterned with environmentally responsive hydrogels. Biomedical Microdevices 5(3) 177-184. (Pubitemid 37265268)
    • (2003) Biomedical Microdevices , vol.5 , Issue.3 , pp. 177-184
    • Hilt, J.Z.1    Gupta, A.K.2    Bashir, R.3    Peppas, N.A.4
  • 56
    • 0037221816 scopus 로고    scopus 로고
    • Drinking water contamination in Walkerton, Ontario: Positive resolutions from a tragic event
    • Holme R. (2003). Drinking water contamination in Walkerton Ontario: Positive resolutions from a tragic event. Water Science & Technology 47(3) 1-6. (Pubitemid 36300831)
    • (2003) Water Science and Technology , vol.47 , Issue.3 , pp. 1-6
    • Holme, R.1
  • 57
    • 84901322834 scopus 로고    scopus 로고
    • Honeywell. Retrieved October 20 2012 from
    • Honeywell. (2012). Durafet pH sensor. Retrieved October 20 2012 from https://www.honeywellprocess.com/en-us/explore/products/instrumentation/ analytical-instruments-and-sensors/ph-orp/Pages/durafet-non-glass-ph-sensor. aspx
    • (2012) Durafet PH Sensor
  • 58
    • 63049109161 scopus 로고    scopus 로고
    • Fabrication of a screen-printing reference electrode for potentiometric measurement
    • Huang T. (2008). Fabrication of a screen-printing reference electrode for potentiometric measurement. Sensor Letters 6(6) 860-863.
    • (2008) Sensor Letters , vol.6 , Issue.6 , pp. 860-863
    • Huang, T.1
  • 59
    • 64849111418 scopus 로고    scopus 로고
    • Effect of regulations and treatment technologies on water distribution infrastructure
    • Imran S.A. Sa diq R. and Kleiner Y. (2009). Effect of regulations and treatment technologies on water distribution infrastructure. Journal of American Water Works Association 101(3) 82-95.
    • (2009) Journal of American Water Works Association , vol.101 , Issue.3 , pp. 82-95
    • Imran, S.A.1    Sa Diq, R.2    Kleiner, Y.3
  • 61
    • 33747501199 scopus 로고    scopus 로고
    • Measurement of chlorine dioxide penetration in dairy process pipe biofilms during disinfection
    • DOI 10.1007/s00253-005-0274-5
    • Jang A. Szabo J. Hosni A. Coughlin M. and Bishop P. (2006). Measurement of chlorine dioxide penetration in dairy process pipe biofilms during disinfection. Applied Microbiology and Biotechnology 72 368-376. (Pubitemid 44273061)
    • (2006) Applied Microbiology and Biotechnology , vol.72 , Issue.2 , pp. 368-376
    • Jang, A.1    Szabo, J.2    Hosni, A.A.3    Coughlin, M.4    Bishop, P.L.5
  • 63
    • 0000967898 scopus 로고    scopus 로고
    • Continuous flow system for online water monitoring using back-side contact ISFET based sensors
    • Jimenez C. Marques I. and Bartroli J. (1996). Continuous flow system for online water monitoring using back-side contact ISFET based sensors. Analytical Chemistry 68 3801-3807.
    • (1996) Analytical Chemistry , vol.68 , pp. 3801-3807
    • Jimenez, C.1    Marques, I.2    Bartroli, J.3
  • 64
    • 0030723770 scopus 로고    scopus 로고
    • Potentiometric pH sensors based on chemically modified electrodes with electropolymerized metal-tetraaminophthalocyanine
    • DOI 10.1016/S0039-9140(97)00124-0, PII S0039914097001240
    • Kang T. Xie Z. Tang H. Shen G. and Yu R. (1997). Potentiometric pH sensors based on chemically modified electrodes with electropolymerized metaltetraaminophthalocyanine. Talanta 45 291-296. (Pubitemid 27506667)
    • (1997) Talanta , vol.45 , Issue.2 , pp. 291-296
    • Kang, T.-F.1    Xie, Z.-Y.2    Tang, H.3    Shen, G.-L.4    Yu, R.-Q.5
  • 65
    • 0142122165 scopus 로고    scopus 로고
    • E lectrical conductivity imaging via contactless measurements: An experimental study
    • Karbeyaz B. and Gençer N. (2003). E lectrical conductivity imaging via contactless measurements: An experimental study. IEEE Transactions on Medical Imaging 22(5) 627-635.
    • (2003) IEEE Transactions on Medical Imaging , vol.22 , Issue.5 , pp. 627-635
    • Karbeyaz, B.1    Gençer, N.2
  • 67
    • 79961076740 scopus 로고    scopus 로고
    • Rapid detection an d enumeration of Giardia lamblia cysts in tap water samples by immunomagnetic separation and flow cytometric analysis
    • Keserue H.-A. F̈ uchslin H.P. and Egli T. (2011). Rapid detection an d enumeration of Giardia lamblia cysts in tap water samples by immunomagnetic separation and flow cytometric analysis. Applied and Environmental Microbiology 77 5420-5427.
    • (2011) Applied and Environmental Microbiology , vol.77 , pp. 5420-5427
    • Keserue, H.-A.1    F̈uchslin, H.P.2    Egli, T.3
  • 69
    • 71849104106 scopus 로고    scopus 로고
    • Robus t sensor for turbidity measurement from light scattering and absorbing liquids
    • Kontturi V. Turunen P. Uozumi J. and Peiponen K.E. (2009). Robus t sensor for turbidity measurement from light scattering and absorbing liquids. Optics Letter 34(23) 3743-3745.
    • (2009) Optics Letter , vol.34 , Issue.23 , pp. 3743-3745
    • Kontturi, V.1    Turunen, P.2    Uozumi, J.3    Peiponen, K.E.4
  • 70
    • 70349718271 scopus 로고    scopus 로고
    • Review of materials and techniques for in vivo pH monitoring
    • Korostynska O. Arshak K Gill E. and Arshak A. (2008). Review of materials and techniques for in vivo pH monitoring. IEEE Sensors Journal 8(1) 167-183.
    • (2008) IEEE Sensors Journal , vol.8 , Issue.1 , pp. 167-183
    • Korostynska, O.1    Arshak, K.2    Gill, E.3    Arshak, A.4
  • 71
    • 79958040746 scopus 로고    scopus 로고
    • An effective method of sensor data transmissions in a waterquality monitoring system
    • Kwon D. (2011). An effective method of sensor data transmissions in a waterquality monitoring system. Journal of Convergence Information Technology 6(5) 218-223.
    • (2011) Journal of Convergence Information Technology , vol.6 , Issue.5 , pp. 218-223
    • Kwon, D.1
  • 72
  • 74
    • 29144435222 scopus 로고    scopus 로고
    • Potentiometric pH sensors based on electrodeposited polymers
    • DOI 10.1016/j.polymer.2005.10.095, PII S0032386105015594
    • Lakard B. Herlem G. Lakard S. Guyetant R. and Fahys B. (2005). Potentiometric pH sensors based on electrodeposited polymers. Polymer 46 12233-12239. (Pubitemid 41815267)
    • (2005) Polymer , vol.46 , Issue.26 , pp. 12233-12239
    • Lakard, B.1    Herlem, G.2    Lakard, S.3    Guyetant, R.4    Fahys, B.5
  • 77
    • 37549016392 scopus 로고    scopus 로고
    • Measurement of pH and dissolved oxygen within cell culture media using a hydrogel microarray sensor
    • Lee S. Ibey B.L. Cote G.L. and Pishko M.V. (2008). Measurement of pH and dissolved oxygen within cell culture media using a hydrogel microarray sensor. Sensors and Actuators B: Chemical 128(2) 388-398.
    • (2008) Sensors and Actuators B: Chemical , vol.128 , Issue.2 , pp. 388-398
    • Lee, S.1    Ibey, B.L.2    Cote, G.L.3    Pishko, M.V.4
  • 79
    • 77949305386 scopus 로고    scopus 로고
    • Characterization and application of a chlorine microelectrode for measuring monochloramine within a biofilm
    • Lee W. Pressman J. Wahman D. and Bishop P. (2010). Characterization and application of a chlorine microelectrode for measuring monochloramine within a biofilm. Sensors Actuators B 145 734-742.
    • (2010) Sensors Actuators B , Issue.145 , pp. 734-742
    • Lee, W.1    Pressman, J.2    Wahman, D.3    Bishop, P.4
  • 80
    • 79951606299 scopus 로고    scopus 로고
    • Free chlorine and monochloramine application to nitrifying biofilm: Comparison of biofilm penetration activity and viability
    • Lee W. Wahman D. Bishop P. and Pressman J. (2011b). Free chlorine and monochloramine application to nitrifying biofilm: Comparison of biofilm penetration activity and viability. Environmental Science & Technology 45 1412-1419.
    • (2011) Environmental Science & Technology , vol.45 , pp. 1412-1419
    • Lee, W.1    Wahman, D.2    Bishop, P.3    Pressman, J.4
  • 82
    • 79960816275 scopus 로고    scopus 로고
    • The fabrication and experiment of a four-electrode conductivity sensor for fresh water
    • Li W. Liu F. Wang K. and Wen Z. (2011). The fabrication and experiment of a four-electrode conductivity sensor for fresh water. Key Engineering Materials 483 341-344.
    • (2011) Key Engineering Materials , vol.483 , pp. 341-344
    • Li, W.1    Liu, F.2    Wang, K.3    Wen, Z.4
  • 83
    • 0037047232 scopus 로고    scopus 로고
    • PH sensitivity of polyaniline and its substituted derivatives
    • DOI 10.1016/S0022-0728(02)01005-7, PII S0022072802010057
    • Lindfors T. and Ivaska A. (2002). pH sensitivity of polyaniline and its substituted derivatives. Journal of Electroanalytical Chemistry 531 43-52. (Pubitemid 35011484)
    • (2002) Journal of Electroanalytical Chemistry , vol.531 , Issue.1 , pp. 43-52
    • Lindfors, T.1    Ivaska, A.2
  • 84
    • 33746033374 scopus 로고    scopus 로고
    • PH electrodes constructed from polyaniline/zeolite and polypyrrble/zeolite conductive blends
    • DOI 10.1002/app.23590
    • Malkaj P. Dalas E. Viteratos E. and Sakkopoulos S. (2005). pH electrodes constructed from polyaniline/zeolite and polypyrrole/zeolite conductive blends. Journal of Applied Polymer Science 101 1853-1856. (Pubitemid 44076983)
    • (2006) Journal of Applied Polymer Science , vol.101 , Issue.3 , pp. 1853-1856
    • Malkaj, P.1    Dalas, E.2    Viteratos, E.3    Sakkopoulos, S.4
  • 85
    • 0028113153 scopus 로고
    • An optical biosensor using a fluorescent, swelling sensing element
    • DOI 10.1016/0956-5663(94)90015-9
    • McCurley M.F. (1994). An optical biosensor using a fluorescent swelling sensing element. Biosensors & Bioelectronics 9 527-533. (Pubitemid 24314968)
    • (1994) Biosensors and Bioelectronics , vol.9 , Issue.7 , pp. 527-533
    • McCurley, M.F.1
  • 86
    • 33745632454 scopus 로고
    • Swelling of a polymer membrane for use in a glucose biosensor
    • McCurley M.F. and Seitz W.R. (1992). Swelling of a polymer membrane for use in a glucose biosensor. ACS Symposium Series 487 301-309.
    • (1992) ACS Symposium Series , vol.487 , pp. 301-309
    • McCurley, M.F.1    Seitz, W.R.2
  • 87
    • 84917512594 scopus 로고    scopus 로고
    • In WHO and OECD A. Dufour M. Snozzi W. Koster J. Bartram E. Ronchi and L. Fewtre (Eds.) Assessing microbial safety of drinking water: Improving approaches an d methods. IWA Publishing: London. Retrieved February 10 2012 from
    • Medema G.J. Payment P. Dufour A Robertson W.,Waite M. Hunter P. Kirby R. and Andersson Y. (2003). Safe drinking water: An ongoing challenge. In WHO and OECD A. Dufour M. Snozzi W. Koster J. Bartram E. Ronchi and L. Fewtre (Eds.) Assessing microbial safety of drinking water: Improving approaches an d methods. IWA Publishing: London. Retrieved February 10 2012 from http://www.who.int/ water sanitation health/dwq/en/9241546301 chap1.pdf
    • (2003) Safe Drinking Water: An Ongoing Challenge
    • Medema, G.J.1    Payment, P.2    Dufour, A.3    Robertson, W.4    Waite, M.5    Hunter, P.6    Kirby, R.7    Andersson, Y.8
  • 89
    • 84901332839 scopus 로고    scopus 로고
    • Turbidity sensor for underwater applications
    • Retrieved June 12 2011 from
    • Mylvaganam S. Jakobsen T 2008 Turbidity sensor for underwater applications Sensor Design and System Performance with Calibration Results Retrieved June 12 2011 from http://www.comm-tec.com/library/technical papers/singlep ointdoppler/turbidity%20sensor%20design%20and% 20performance.pdf
    • (2008) Sensor Design and System Performance with Calibration Results
    • Mylvaganam, S.1    Jakobsen, T.2
  • 90
    • 0037058666 scopus 로고    scopus 로고
    • 3 mixture film
    • DOI 10.1016/S0925-4005(02)00238-1, PII S0925400502002381
    • Na X. Niu W. Li H. and Xie J. (2002). A novel dissolved oxygen sensor based on MISFET structure with Pt-LaF3 mixture film. Sensors and Actuators B 87 222-225. (Pubitemid 35282267)
    • (2002) Sensors and Actuators, B: Chemical , vol.87 , Issue.2 , pp. 222-225
    • Na, X.1    Niu, W.2    Li, H.3    Xie, J.4
  • 91
    • 84892855465 scopus 로고    scopus 로고
    • National Research Council Canada. Retrieved June 18 2011 from
    • National Research Council Canada. (2004). Monitoring water quality in distribution system. Retrieved June 18 2011 from http://www. sustainablecommunities.fcm. ca/files/Infraguide/Po table Water/Monitor water quality distr syst 433k.pdf
    • (2004) Monitoring Water Quality in Distribution System
  • 92
    • 10644240982 scopus 로고    scopus 로고
    • Chemical modulation of thermosensitive poly(N-isopropylacrylamide) microsphere swelling: A new strategy for chemical sensing
    • Oktar O. Caglar P. and Seitz W.R. (2005). Chemical modulation of thermosensitive poly(N-isopropylacrylamide) microsphere swelling: a new strategy for chemical sensing. Sensors and Actuators B 104 179-185.
    • (2005) Sensors and Actuators B , vol.104 , pp. 179-185
    • Oktar, O.1    Caglar, P.2    Seitz, W.R.3
  • 93
    • 84901348293 scopus 로고    scopus 로고
    • OMAG (Ontario Ministry of the Attorney General Report of the Walkerton inquiry. The events of May 2000 and related issues. Queen's Printer for Ontario Canada 525 p. Retrieved February 10 2012 from
    • OMAG (Ontario Ministry of the Attorney General). (2002). Report of the Walkerton inquiry. The events of May 2000 and related issues. Queen's Printer for Ontario Canada 525 p. Retrieved February 10 2012 from http://www. attonievgeneral. jus.pov.on.ca/engUsh/about/purjs/waakertori/partl/WI Chapter 03.pdf
    • (2002)
  • 94
    • 84856949946 scopus 로고    scopus 로고
    • Development of optical fiber sensor for water quality measurement
    • December 26-28 AIP (American Institute of Physics) Conference Dar esbury Warrington Cheshire UK 2008
    • Omar A.F. and MatJafri M.Z. (2007 December 26-28). Development of optical fiber sensor for water quality measurement. In Proceedings of National Physics Conference 2007-PERFIK 2007. AIP (American Institute of Physics) Conference Dar esbury Warrington Cheshire UK 2008 398-402.
    • (2007) Proceedings of National Physics Conference 2007-PERFIK 2007 , pp. 398-402
    • Omar, A.F.1    Matjafri, M.Z.2
  • 96
    • 26444516522 scopus 로고    scopus 로고
    • Continuous detection of hypochlorous acid/hypochlorite for water quality monitoring and control
    • Ordeiga O. Masa R. Gonzaloa J. Campoa F. Munoza F. and de Harob C. (2005). Continuous detection of hypochlorous acid/hypochlorite for water quality monitoring and control. Electroanalysis 17(18) 1641-1648.
    • (2005) Electroanalysis , vol.17 , Issue.18 , pp. 1641-1648
    • Ordeiga, O.1    Masa, R.2    Gonzaloa, J.3    Campoa, F.4    Munoza, F.5    De Harob, C.6
  • 101
    • 84901304153 scopus 로고    scopus 로고
    • Pulse Instrument. Retrieved October 12 2012 from
    • Pulse Instrument. (2012 ). PI0150-pH ISFET Non-Glass pH Electrode: Submersible Mounting. Retrieved October 12 2012 from http://www. pulseinstruments. net/pi0150-phisfetnon-glassphelectrode.aspx
    • (2012) PI0150-pH ISFET Non-Glass PH Electrode: Submersible Mounting
  • 103
    • 0242720768 scopus 로고    scopus 로고
    • Electronically controllable microvalves based on smart hydrogels: Magnitudes and potential applications
    • Richter A. Kuckling D. Howitz S. Gehring T. and Arndt K.F. (2003). Electronically controllable microvalves based on smart hydrogels: magnitudes and potential applications. Journal of Microelectromechanical Systems 12(5) 748-753.
    • (2003) Journal of Microelectromechanical Systems , vol.12 , Issue.5 , pp. 748-753
    • Richter, A.1    Kuckling, D.2    Howitz, S.3    Gehring, T.4    Arndt, K.F.5
  • 104
    • 0000748921 scopus 로고    scopus 로고
    • An optically sensitive membrane for pH based on swellable polymer microspheres in a hydrogel
    • Rooney M. and Seitz W.R. (1999). An optically sensitive membrane for pH based on swellable polymer microspheres in a hydrogel. Analytical Communications 36 267-270.
    • (1999) Analytical Communications , vol.36 , pp. 267-270
    • Rooney, M.1    Seitz, W.R.2
  • 107
    • 0001913281 scopus 로고    scopus 로고
    • Osmotic de-swelling of polystyrene microgel particles
    • Saunders B.R. and Vincent B. (1997 ). Osmotic de-swelling of polystyrene microgel particles. Colloid and Polymer Science 275 9-17. (Pubitemid 127494563)
    • (1997) Colloid and Polymer Science , vol.275 , Issue.1 , pp. 9-17
    • Saunders, B.R.1    Vincent, B.2
  • 109
    • 0004869855 scopus 로고
    • New directions in fibre optic chemical sensors: Sensors based on polymer swelling
    • Seitz W.R. (1993). New directions in fibre optic chemical sensors: Sensors based on polymer swelling. Journal of Molecular Structure 292 105-114.
    • (1993) Journal of Molecular Structure , vol.292 , pp. 105-114
    • Seitz, W.R.1
  • 111
    • 0028773527 scopus 로고
    • Single fiber-optic pH sensor based on changes in reflection accompanying polymer swelling
    • Shakhsher Z. Seitz W.R. and Legg K.D. (1994). Single fiber-optic pH sensor based on changes in reflection accompanying polymer swelling. Analytical Chemistry 66 1731-1735.
    • (1994) Analytical Chemistry , vol.66 , pp. 1731-1735
    • Shakhsher, Z.1    Seitz, W.R.2    Legg, K.D.3
  • 115
    • 0004290685 scopus 로고
    • London: John Churchill. Retrieved February 10 2012 from
    • Snow J. (1885). On the mode of communication of cholera (p. 139). London: John Churchill. Retrieved February 10 2012 from http://www.ph.ucla. edu/epi/snow/snowbook.html
    • (1885) On the Mode of Communication of Cholera , pp. 139
    • Snow, J.1
  • 116
    • 80052278082 scopus 로고    scopus 로고
    • Dissolved oxygen concentration field measurement in micro-scale water flows using PtOEP/PS film sensor
    • Song D.H. Kim H.D. and Kim K.C. (2011). Dissolved oxygen concentration field measurement in micro-scale water flows using PtOEP/PS film sensor. Journal of Visualization 14(3) 295-304.
    • (2011) Journal of Visualization , vol.14 , Issue.3 , pp. 295-304
    • Song, D.H.1    Kim, H.D.2    Kim, K.C.3
  • 118
    • 78650419548 scopus 로고    scopus 로고
    • Advances in on-line drinking water quality monitoring and early warning systems
    • Storey M.V. van der Gaag B. and Burns B.P. (2011 ). Advances in on-line drinking water quality monitoring and early warning systems. Water Research 45 741-747.
    • (2011) Water Research , vol.45 , pp. 741-747
    • Storey, M.V.1    Van Der Gaag, B.2    Burns, B.P.3
  • 119
    • 0025451585 scopus 로고
    • Phase-transition in polymer gels induced by visible-light
    • Suzuki A. and Tanaka T. (1990). Phase-transition in polymer gels induced by visible-light. Nature 346 345-347.
    • (1990) Nature , vol.346 , pp. 345-347
    • Suzuki, A.1    Tanaka, T.2
  • 120
    • 33747470667 scopus 로고    scopus 로고
    • Persistence of Klebsiella pneumoniae on simulated biofilm in a model drinking water system
    • DOI 10.1021/es060857h
    • Szabo J.G. Rice E.W. and Bishop P. (2006). Persistence of Klebsiella pneumonia on simulated biofilm in a model drinking water system. Environmental Science & Technology 40 4996-5002. (Pubitemid 44257464)
    • (2006) Environmental Science and Technology , vol.40 , Issue.16 , pp. 4996-5002
    • Szabo, J.G.1    Rice, E.W.2    Bishop, P.L.3
  • 121
    • 5244321910 scopus 로고
    • Collapse of gels and the critical endpoint
    • Tanaka T. (1978). Collapse of gels and the critical endpoint. Physical Review Letters 40(12) 820-823.
    • (1978) Physical Review Letters , vol.40 , Issue.12 , pp. 820-823
    • Tanaka, T.1
  • 123
    • 84901304054 scopus 로고    scopus 로고
    • The Office of Waterworks Seoul Retrieved November 29 2011 from
    • The Office of Waterworks Seoul. (2011). Online realtime water quality opening service. Retrieved November 29 2011 from http://water.seoul.go. kr/waternow/RealDataFullScale.php
    • (2011) Online Realtime Water Quality Opening Service
  • 124
    • 33745963008 scopus 로고    scopus 로고
    • Hydrogel-based piezoresistive pH sensors: Design, simulation and output characteristics
    • DOI 10.1016/j.snb.2005.10.041, PII S0925400505008683
    • Trinh Q.T. Gerlach G. Sorber J. and Arndt K.-F. (2006). Hydrogel-based piezoresistive pH sensors: design simulation and output characteristics. Sensors and Actuators B 117 17-26. (Pubitemid 44055913)
    • (2006) Sensors and Actuators, B: Chemical , vol.117 , Issue.1 , pp. 17-26
    • Thong Trinh, Q.1    Gerlach, G.2    Sorber, J.3    Arndt, K.-F.4
  • 126
    • 84901375795 scopus 로고    scopus 로고
    • Tuscon Water. Retrieved April 8 2011 from
    • Tuscon Water. (2011). Water quality monitoring program. Retrieved April 8 2011 from http://cms3.tucsonaz.gov/water/wq monitoring
    • (2011) Water Quality Monitoring Program
  • 127
    • 0027068213 scopus 로고
    • Miniaturized multi-enzyme biosensors integrated with pH sensors on flexible polymer carriers for in vivo applications
    • DOI 10.1016/0956-5663(92)85056-G
    • Urban G. Jobst G. Keplinger F. Aschauer E. Tilado O. Fasching R. and Kohl F. (1992). Miniaturized multi-enzyme biosensors integrated with pH sensors on flexible polymer carriers for in v ivo applications. Biosensors & Bioelectronics 7 733-739. (Pubitemid 23038819)
    • (1992) Biosensors and Bioelectronics , vol.7 , Issue.10 , pp. 733-739
    • Urban, G.1    Jobst, G.2    Keplinger, F.3    Aschauer, E.4    Tilado, O.5    Fasching, R.6    Kohl, F.7
  • 131
    • 0012381510 scopus 로고    scopus 로고
    • USEPA. Retrieved July 15 2010 from
    • USEPA. (2009 b). National primary drinking w ater regulations. Retrieved July 15 2010 from http://water.epa.gov/drink/contaminants/upload/mcl-2.pdf
    • (2009) National Primary Drinking W Ater Regulations
  • 132
    • 42049110379 scopus 로고    scopus 로고
    • USEPA Office of Water. Retrieved February 6 2012 from
    • USEPA Office of Water 2002) Nitrification. Retrieved February 6 2012 from http://www.epa.gov/ogwdw/disinfection/tcr/pdfs/whitepaper tcr nitrification. pdf
    • (2002) Nitrification
  • 133
    • 0037208325 scopus 로고    scopus 로고
    • Fiber optic probes for biomedical optical spectroscopy
    • Utzinger U. and Richards-Kortum R. (2003). Fiber optic probes for biomedical optical spectroscopy. Journal of Biomedical Optics 8(1) 121-147.
    • (2003) Journal of Biomedical Optics , vol.8 , Issue.1 , pp. 121-147
    • Utzinger, U.1    Richards-Kortum, R.2
  • 134
    • 0029342770 scopus 로고
    • A closed loop scheme for phase-sensitive fluorometry
    • Vadde V. and Srinivas V. (1995). A closed loop scheme for phase-sensitive fluorometry. Review of Scientific Instruments 66(7) 3750-3754.
    • (1995) Review of Scientific Instruments , vol.66 , Issue.7 , pp. 3750-3754
    • Vadde, V.1    Srinivas, V.2
  • 135
    • 0037024632 scopus 로고    scopus 로고
    • Compact optical sensor for real-time monitoring of bacterial growth for space applications
    • van Benthem R.C. Assem D.V. and Krooneman J. (2006). Compact optical sensor for real-time monitoring of bacterial growth for space applications Annals of the New York Academy of Sciences 974(1) 541-555.
    • (2006) Annals of the New York Academy of Sciences , vol.974 , Issue.1 , pp. 541-555
    • Van Benthem, R.C.1    Assem, D.V.2    Krooneman, J.3
  • 140
    • 84901374959 scopus 로고    scopus 로고
    • Water Supply Department Surat Municipal Corporation Retrieved May 15 2011 f rom
    • Water Supply Department Surat Municipal Corporation. (2009). Water Quality Monitoring System. Retrieved May 15 2011 f rom http://www.urbanindia. nic.in/programme/uwss/slb/Workshop/Presentations/Session II/11-12/Surat Water Quality Monitoring.pdf
    • (2009) Water Quality Monitoring System
  • 142
    • 0022745072 scopus 로고
    • Health impact of acidic deposition
    • WHO
    • WHO (1986). Health impact of acidic deposition. Science of the Total Environment 52 157-187.
    • (1986) Science of the Total Environment , vol.52 , pp. 157-187
  • 143
    • 84872620758 scopus 로고    scopus 로고
    • PH in Drinking-water: Background document for development ofWHO Guidelines for Drinking-water Quality
    • WHO (2nd ed. Vol. 2). Health criteria and other supporting information. Geneva: Author
    • WHO (2003). pH in Drinking-water: Background document for development ofWHO Guidelines for Drinking-water Quality. Originally published in Guidelines for drinking-water quality (2nd ed. Vol. 2). Health criteria and other supporting information. Geneva: Author 1996.
    • (2003) Originally Published in Guidelines for Drinking-water Quality , pp. 1996
  • 144
    • 84858376385 scopus 로고    scopus 로고
    • WHO,Retrieved June 12 2011 from
    • WHO (2006). Guidelin es for drinking water quality. Retrieved June 12 2011 from http://www.who.int/water sanitation health/dwq/gdwq3rev/en/index.html
    • (2006) Guidelin Es for Drinking Water Quality
  • 146
    • 0025055160 scopus 로고
    • Ammonia-oxidizing bacteria in a chloraminated distribution sytem: Seasonal occurrence, distribution, and disinfection resistance
    • Wolfe R. Lieu N. Izaguirre G. and Means E. (1990). Ammonia-oxidizing bacteria in a chloraminated distribution system: Seasonal occurrence distribution and disinfection resistance. Applied and Environmental Microbiology 56 451-462. (Pubitemid 20055320)
    • (1990) Applied and Environmental Microbiology , vol.56 , Issue.2 , pp. 451-462
    • Wolfe, R.L.1    Lieu, N.I.2    Izaguirre, G.3    Means, E.G.4
  • 147
    • 2942609031 scopus 로고    scopus 로고
    • Fiber-optic chemical sensors and biosensors
    • DOI 10.1021/ac040049d
    • Wolfbeis O. (2004). Fiber optic chemical sensors and biosensors. Analytical Chemistry 76(12) 3269-3284. (Pubitemid 38747270)
    • (2004) Analytical Chemistry , vol.76 , Issue.12 , pp. 3269-3284
    • Wolfbeis, O.S.1
  • 149
    • 79958176948 scopus 로고    scopus 로고
    • Free chlorine sensing using an interferometric sensor
    • Xu J. (2011). Free chlorine sensing using an interferometric sensor. Sensors and Actuators B: Chemical 157 812-819.
    • (2011) Sensors and Actuators B: Chemical , vol.157 , pp. 812-819
    • Xu, J.1
  • 150
    • 84901341233 scopus 로고    scopus 로고
    • YSI
    • YSI 2012 http://www.ysi.com/media/pdfs/E32-6150-ROX-DO-Sensor.pdf
    • (2012)
  • 151
    • 0141705540 scopus 로고    scopus 로고
    • 2- using a hydrogel swelling microcantilever sensor
    • DOI 10.1021/ac0343026
    • Zhang Y. Ji H.F. Brown G.M. and Thundat T. (2003). Detection of CrO4 2-using a hydrogel swelling microcantilever sensor. Analytical Chemistry 75(18) 4773-4777. (Pubitemid 37139777)
    • (2003) Analytical Chemistry , vol.75 , Issue.18 , pp. 4773-4777
    • Zhang, Y.1    Ji, H.-F.2    Brown, G.M.3    Thundat, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.