메뉴 건너뛰기




Volumn 35, Issue 17, 2014, Pages 1120-1130

Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: The CORE320 study

(30)  Rochitte, Carlos E d   George, Richard T a   Chen, Marcus Y e   Arbab Zadeh, Armin a   Dewey, Marc f   Miller, Julie M a   Niinuma, Hiroyuki g,h   Yoshioka, Kunihiro g   Kitagawa, Kakuya i   Nakamori, Shiro i   Laham, Roger j   Vavere, Andrea L a   Cerci, Rodrigo J a   Mehra, Vishal C a   Nomura, Cesar k   Kofoed, Klaus F l   Jinzaki, Masahiro m   Kuribayashi, Sachio m   De Roos, Albert n   Laule, Michael f   more..


Author keywords

Atherosclerosis; Imaging; Ischemia; Multislice computed tomography; Perfusion

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION; COMPUTED TOMOGRAPHY SCANNER; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY OBSTRUCTION; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; HEART INFARCTION; HEART MUSCLE PERFUSION; HUMAN; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; MULTICENTER STUDY; PERFORMANCE; PREDICTIVE VALUE; PREVALENCE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; VERY ELDERLY; CLINICAL TRIAL; COMPARATIVE STUDY; EVALUATION STUDY; HEMODYNAMICS; MULTIDETECTOR COMPUTED TOMOGRAPHY; MYOCARDIAL PERFUSION IMAGING; PATHOPHYSIOLOGY; PHYSIOLOGY; PROCEDURES; PROSPECTIVE STUDY; RECEIVER OPERATING CHARACTERISTIC; SCINTISCANNING;

EID: 84900027732     PISSN: 0195668X     EISSN: 15229645     Source Type: Journal    
DOI: 10.1093/eurheartj/eht488     Document Type: Article
Times cited : (343)

References (33)
  • 8
    • 78449313114 scopus 로고    scopus 로고
    • Accf/scct/ acr/aha/ase/asnc/nasci/scai/scmr 2010 appropriate use criteria for cardiac computed tomography
    • A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance
    • Taylor AJ, Cerqueira M, Hodgson JM, Mark D, Min J, O'Gara P, Rubin GD, Kramer CM, Berman D, Brown A, Chaudhry FA, Cury RC, Desai MY, Einstein AJ, Gomes AS, Harrington R, Hoffmann U, Khare R, Lesser J, McGann C, Rosenberg A, Schwartz R, Shelton M, Smetana GW, Smith SC, Jr. ACCF/SCCT/ ACR/AHA/ASE/ASNC/ NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance. J Am Coll Cardiol 2010;56:1864-1894
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1864-1894
    • Taylor, A.J.1    Cerqueira, M.2    Hodgson, J.M.3    Mark, D.4    Min, J.5    O'Gara, P.6    Rubin, G.D.7    Kramer, C.M.8    Berman, D.9    Brown, A.10    Chaudhry, F.A.11    Cury, R.C.12    Desai, M.Y.13    Einstein, A.J.14    Gomes, A.S.15    Harrington, R.16    Hoffmann, U.17    Khare, R.18    Lesser, J.19    McGann, C.20    more..
  • 11
    • 36148932978 scopus 로고    scopus 로고
    • Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging
    • Di Carli MF, Dorbala S, Curillova Z, Kwong RJ, Goldhaber SZ, Rybicki FJ, Hachamovitch R. Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging. J Nucl Cardiol 2007;14:799-809
    • (2007) J Nucl Cardiol , vol.14 , pp. 799-809
    • Di Carli, M.F.1    Dorbala, S.2    Curillova, Z.3    Kwong, R.J.4    Goldhaber, S.Z.5    Rybicki, F.J.6    Hachamovitch, R.7
  • 14
    • 84863664808 scopus 로고    scopus 로고
    • Computed tomography myocardial perfusion imaging with 320-row detector CT accurately detects myocardial ischemia in patients with obstructive coronary artery disease
    • George RT, Arbab-Zadeh A, Miller JM, Vavere AL, Bengel FM, Lardo AC, Lima JA. Computed tomography myocardial perfusion imaging with 320-row detector CT accurately detects myocardial ischemia in patients with obstructive coronary artery disease. Circ Cardiovasc Imaging 2012;5:333-340
    • (2012) Circ Cardiovasc Imaging , vol.5 , pp. 333-340
    • George, R.T.1    Arbab-Zadeh, A.2    Miller, J.M.3    Vavere, A.L.4    Bengel, F.M.5    Lardo, A.C.6    Lima, J.A.7
  • 17
    • 84863863616 scopus 로고    scopus 로고
    • The emerging role of cardiac computed tomography for the assessment of coronary perfusion: A systematic review and meta-Analysis
    • Tashakkor AY, Nicolaou S, Leipsic J, Mancini GB. The emerging role of cardiac computed tomography for the assessment of coronary perfusion: A systematic review and meta-Analysis. Can J Cardiol 2012;28:413-422
    • (2012) Can J Cardiol , vol.28 , pp. 413-422
    • Tashakkor, A.Y.1    Nicolaou, S.2    Leipsic, J.3    Mancini, G.B.4
  • 23
    • 44149086854 scopus 로고    scopus 로고
    • Evaluation of the american college of cardiology foundation/american society of nuclear cardiology appropriateness criteria for spect myocardial perfusion imaging
    • Mehta R,Ward RP, Chandra S, Agarwal R, Williams KA. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging. J Nucl Cardiol 2008;15: 337-344
    • (2008) J Nucl Cardiol , vol.15 , pp. 337-344
    • Mehta, R.1    Ward, R.P.2    Chandra, S.3    Agarwal, R.4    Williams, K.A.5
  • 24
    • 0019363890 scopus 로고
    • Coronary artery atherosclerosis: Severity of the disease, severity of angina pectoris and compromised left ventricular function
    • Leaman DM, BrowerRW, MeesterGT, Serruys P, van Den Brand M. Coronary artery atherosclerosis: Severity of the disease, severity of angina pectoris and compromised left ventricular function. Circulation 1981;63:285-299
    • (1981) Circulation , vol.63 , pp. 285-299
    • Leaman, D.M.1    Brower, R.W.2    Meester, G.T.3    Serruys, P.4    Van Den Brand, M.5
  • 26
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982;143:29-36
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 27
    • 0031742873 scopus 로고    scopus 로고
    • Sample size calculations in studies of test accuracy
    • Obuchowski NA. Sample size calculations in studies of test accuracy. Stat Methods Med Res 1998;7:371-392
    • (1998) Stat Methods Med Res , vol.7 , pp. 371-392
    • Obuchowski, N.A.1
  • 29
    • 0032436380 scopus 로고    scopus 로고
    • Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography
    • Berman DS, Kang X, Van Train KF, Lewin HC, Cohen I, Areeda J, Friedman JD, Germano G, Shaw LJ, Hachamovitch R. Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1998; 32:1987-1995
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1987-1995
    • Berman, D.S.1    Kang, X.2    Van Train, K.F.3    Lewin, H.C.4    Cohen, I.5    Areeda, J.6    Friedman, J.D.7    Germano, G.8    Shaw, L.J.9    Hachamovitch, R.10
  • 30
    • 75749129917 scopus 로고    scopus 로고
    • Meta-Analysis: Noninvasive coronary angiography using computed tomography versus magnetic resonance imaging
    • Schuetz GM, Zacharopoulou NM, Schlattmann P, Dewey M. Meta-Analysis: Noninvasive coronary angiography using computed tomography versus magnetic resonance imaging. Ann Intern Med 2010;152:167-177
    • (2010) Ann Intern Med , vol.152 , pp. 167-177
    • Schuetz, G.M.1    Zacharopoulou, N.M.2    Schlattmann, P.3    Dewey, M.4
  • 32
    • 84863877648 scopus 로고    scopus 로고
    • Adenosine-stress dynamic real-Time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results
    • Weininger M, Schoepf UJ, Ramachandra A, Fink C, RoweGW, Costello P, Henzler T. Adenosine-stress dynamic real-Time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results. Eur J Radiol 2012;81:3703-3710
    • (2012) Eur J Radiol , vol.81 , pp. 3703-3710
    • Weininger, M.1    Schoepf, U.J.2    Ramachandra, A.3    Fink, C.4    Rowe, G.W.5    Costello, P.6    Henzler, T.7
  • 33
    • 0036788282 scopus 로고    scopus 로고
    • Single-vessel coronary artery stenosis: Myocardial perfusion imaging with Gadomer-17 first-pass MR imaging in a swine model of comparison with gadopentetate dimeglumine
    • Gerber BL, Bluemke DA, Chin BB, Boston RC, Heldman AW, Lima JA, Kraitchman DL. Single-vessel coronary artery stenosis: Myocardial perfusion imaging with Gadomer-17 first-pass MR imaging in a swine model of comparison with gadopentetate dimeglumine. Radiology 2002;225:104-112
    • (2002) Radiology , vol.225 , pp. 104-112
    • Gerber, B.L.1    Bluemke, D.A.2    Chin, B.B.3    Boston, R.C.4    Heldman, A.W.5    Lima, J.A.6    Kraitchman, D.L.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.