메뉴 건너뛰기




Volumn 4, Issue , 2014, Pages

Titanium (III) cation selective electrode based on synthesized tris(2pyridyl) methylamine ionophore and its application in water samples

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL MEMBRANE; CATION; IONOPHORE; METHYLAMINE; TITANIUM; WATER;

EID: 84898634229     PISSN: None     EISSN: 20452322     Source Type: Journal    
DOI: 10.1038/srep04664     Document Type: Article
Times cited : (45)

References (35)
  • 1
    • 14844292545 scopus 로고    scopus 로고
    • 4) in the context of major hazards - Spill behaviour using REACTPOOL
    • DOI 10.1016/j.jhazmat.2004.12.001, PII S0304389404006016
    • Kapias, T. & Griffiths, R. Accidental releases of titanium tetrachloride (TiCl4) in the context of major hazards spill behaviour using REACTPOOL. J. Hazard. Mater. 119, 41-52 (2005). (Pubitemid 40341498)
    • (2005) Journal of Hazardous Materials , vol.119 , Issue.1-3 , pp. 41-52
    • Kapias, T.1    Griffiths, R.F.2
  • 2
    • 69549112975 scopus 로고    scopus 로고
    • Titanium dioxide nanomaterials and their energy applications
    • Chen, X. Titanium Dioxide Nanomaterials and Their Energy Applications. Chinese. Journal. of Catalysis. 30, 839-851 (2009).
    • (2009) Chinese Journal of Catalysis , vol.30 , pp. 839-851
    • Chen, X.1
  • 3
    • 34447321045 scopus 로고    scopus 로고
    • 2 particles as a component of nanoparticle risk management
    • DOI 10.1016/j.toxlet.2007.04.008, PII S0378427407001282
    • Warheit, D. B. et al.Development of a base set of toxicity tests using ultrafine TiO2 particles as a component of nanoparticle risk management. Toxicol. Lett. 171, 99-110 (2007). (Pubitemid 47058824)
    • (2007) Toxicology Letters , vol.171 , Issue.3 , pp. 99-110
    • Warheit, D.B.1    Hoke, R.A.2    Finlay, C.3    Donner, E.M.4    Reed, K.L.5    Sayes, C.M.6
  • 4
    • 27744533436 scopus 로고    scopus 로고
    • Ultrafine particles cross cellular membranes by nonphagocytic mechanisms in lungs and in cultured cells
    • Geiser, M. et al. Ultrafine particles cross cellular membranes by nonphagocytic mechanisms in lungs and in cultured cells. Environ. Health. Perspect. 113, 1555 (2005).
    • (2005) Environ. Health. Perspect. , vol.113 , pp. 1555
    • Geiser, M.1
  • 5
    • 84876829303 scopus 로고    scopus 로고
    • Distribution of total petroleum hydrocarbons and polycyclic aromatic hydrocarbons in Musa bay sediments(northwest of the Persian Gulf)
    • Tehrani, G. M. et al. Distribution of total petroleum hydrocarbons and polycyclic aromatic hydrocarbons in Musa bay sediments(northwest of the Persian Gulf). Environment Protection Engineering 39, 115-128 (2013).
    • (2013) Environment Protection Engineering , vol.39 , pp. 115-128
    • Tehrani, G.M.1
  • 6
    • 14844292545 scopus 로고    scopus 로고
    • 4) in the context of major hazards - Spill behaviour using REACTPOOL
    • DOI 10.1016/j.jhazmat.2004.12.001, PII S0304389404006016
    • Kapias, T. &Griffiths, R. F. Accidental releases of titanium tetrachloride (TiCl4) in the context of major hazards spill behaviour using REACTPOOL. J. Hazard. Mater. 119, 41-52 (2005). (Pubitemid 40341498)
    • (2005) Journal of Hazardous Materials , vol.119 , Issue.1-3 , pp. 41-52
    • Kapias, T.1    Griffiths, R.F.2
  • 8
    • 84879780806 scopus 로고    scopus 로고
    • Heavy metal contamination in water and sediment of the Port Klang coastal area, Selangor, Malaysia
    • Tavakoly Sany, S. B. et al.Heavy metal contamination in water and sediment of the Port Klang coastal area, Selangor, Malaysia. Environ. Earth. Sci. 69, (2013).
    • (2013) Environ. Earth. Sci. , pp. 69
    • Tavakoly, S.S.B.1
  • 9
    • 84875847109 scopus 로고    scopus 로고
    • Limit of detection and limit of quantification development procedures for organochlorine pesticides analysis in water and sediment matrices
    • Saadati, N. et al. Limit of detection and limit of quantification development procedures for organochlorine pesticides analysis in water and sediment matrices. Chem. Cen. J. 7, 1-10 (2013).
    • (2013) Chem. Cen. J. , vol.7 , pp. 1-10
    • Saadati, N.1
  • 10
    • 40449089741 scopus 로고    scopus 로고
    • Potentiometric ion sensors
    • DOI 10.1021/cr068100w
    • Bobacka, J., Ivaska, A. & Lewenstam, A. Potentiometric ion sensors. Chem. Rev. 108, 329-351 (2008). (Pubitemid 351344443)
    • (2008) Chemical Reviews , vol.108 , Issue.2 , pp. 329-351
    • Bobacka, J.1    Ivaska, A.2    Lewenstam, A.3
  • 11
    • 33846502746 scopus 로고    scopus 로고
    • Zirconium ion selective electrode based on bis(diphenylphosphino) ferrocene incorporated in a poly(vinyl chloride) matrix
    • DOI 10.1016/j.aca.2006.10.059, PII S0003267006021660
    • Gholivand, M. B., Babakhanian, A. & Joshaghani, M. Zirconium ion selective electrode based on bis (diphenylphosphino) ferrocene incorporated in a poly (vinyl chloride) matrix. Anal. Chim. Acta. 584, 302-307 (2007). (Pubitemid 46161291)
    • (2007) Analytica Chimica Acta , vol.584 , Issue.2 , pp. 302-307
    • Gholivand, M.B.1    Babakhanian, A.2    Joshaghani, M.3
  • 13
    • 80052938700 scopus 로고    scopus 로고
    • Conductometric determination of formation constants of tris (2-pyridyl) methylamine and titanium (III) in water-acetonitryl mixture
    • Rezayi, M., Kassim, A., Ahmadzadeh, S., Naji, A. & Ahangar, H. Conductometric determination of formation constants of tris (2-pyridyl) methylamine and titanium (III) in water-acetonitryl mixture. Int. J. Electrochem. Sci. 6, 4378-4387 (2011).
    • (2011) Int. J. Electrochem. Sci. , vol.6 , pp. 4378-4387
    • Rezayi, M.1    Kassim, A.2    Ahmadzadeh, S.3    Naji, A.4    Ahangar, H.5
  • 14
    • 84878717537 scopus 로고    scopus 로고
    • Thermodynamic study on the complex formation between tris (2-Pyridyl) methylamine (tpm)with Fe21, Fe31, Cu21 and Cr31 cations in water-acetonitrile binary solutions using the conductometric method
    • Rezayi, M., Heng, L. Y., Abdi, M. M., Noran, N. M. & Esmaeili, C. A Thermodynamic Study on the Complex Formation Between Tris (2-Pyridyl) Methylamine (tpm)with Fe21, Fe31, Cu21 and Cr31 Cations in Water-Acetonitrile Binary Solutions Using the Conductometric Method. Int. J. Electrochem. Sci 8, 6922-6932 (2013).
    • (2013) Int. J. Electrochem. Sci , vol.8 , pp. 6922-6932
    • Rezayi, M.1    Heng, L.Y.2    Abdi, M.M.3    Noran, N.M.4    Esmaeili, C.A.5
  • 15
    • 0035387928 scopus 로고    scopus 로고
    • A Schiff base complex of Zn(II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion
    • DOI 10.1021/ac001449d
    • Shamsipur, M. et al. A schiff base complex of Zn (II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion. Anal. Chem. 73, 2869-2874 (2001). (Pubitemid 32868141)
    • (2001) Analytical Chemistry , vol.73 , Issue.13 , pp. 2869-2874
    • Shamsipur, M.1    Yousefi, M.2    Hosseini, M.3    Ganjali, M.R.4    Sharghi, H.5    Naeimi, H.6
  • 16
    • 0036479918 scopus 로고    scopus 로고
    • Clotrimazole-triiodide ion association as an ion exchanger for a triiodide ion-selective electrode
    • Farhadi, K. & Maleki, R. Clotrimazole-triiodide ion association as an ion exchanger for a triiodide ion-selective electrode. Anal. Sci. 18, 133-136 (2002).
    • (2002) Anal. Sci. , vol.18 , pp. 133-136
    • Farhadi, K.1    Maleki, R.2
  • 18
    • 4544366331 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes
    • Bakker, E., Buhlmann, P. & Pretsch, E. Carrier-based ion-selective electrodes and bulk optodes. Chem. Rev. 97, 3083-3132 (1997).
    • (1997) Chem. Rev. , vol.97 , pp. 3083-3132
    • Bakker, E.1    Buhlmann, P.2    Pretsch, E.3
  • 20
    • 0001325218 scopus 로고    scopus 로고
    • Polymer membrane ion-selective electrodes-what are the limits
    • Bakker, E., Bühlmann, P. & Pretsch, E. Polymer membrane ion-selective electrodes-what are the limits. Electroanalysis. 11, 915-933 (1999).
    • (1999) Electroanalysis , vol.11 , pp. 915-933
    • Bakker, E.1    Buhlmann, P.2    Pretsch, E.3
  • 21
    • 31744450323 scopus 로고    scopus 로고
    • Novel triiodide PVC-based membrane sensor based on a charge transfer complex of iodine and bis (2-hydroxyacetophenone) butane-2, 3-dihydrazon
    • Ganjali, M. R., Norouzi, P., Shirvani-Arani, S. & Salavati-Niasari, M. Novel triiodide PVC-based membrane sensor based on a charge transfer complex of iodine and bis (2-hydroxyacetophenone) butane-2, 3-dihydrazon. Bulletin-Korean Chemical Society. 26, 1738 (2005).
    • (2005) Bulletin-Korean Chemical Society , vol.26 , pp. 1738
    • Ganjali, M.R.1    Norouzi, P.2    Shirvani-Arani, S.3    Salavati-Niasari, M.4
  • 22
    • 77955412414 scopus 로고    scopus 로고
    • Comparative study on 2-amino-1, 4-naphthoquinone derived ligands as indium (III) selective PVC-based sensors
    • Gupta, V. K., Hamdan, A. J. & Pal, M. K. Comparative study on 2-amino-1, 4-naphthoquinone derived ligands as indium (III) selective PVC-based sensors. Talanta. 82, 44-50 (2010).
    • (2010) Talanta , vol.82 , pp. 44-50
    • Gupta, V.K.1    Hamdan, A.J.2    Pal, M.K.3
  • 23
    • 0000106133 scopus 로고
    • Neutral carrier potassium-selective electrodes with low resistances
    • Nieman, T. A. & Horvai, G. Neutral carrier potassium-selective electrodes with low resistances. Anal. Chim. Acta. 170, 359-363 (1985).
    • (1985) Anal. Chim. Acta. , vol.170 , pp. 359-363
    • Nieman, T.A.1    Horvai, G.2
  • 24
    • 46549096850 scopus 로고
    • Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers
    • Ammann, D. et al. Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers. Anal. Chim. Acta. 171, 119-129 (1985).
    • (1985) Anal. Chim. Acta. , vol.171 , pp. 119-129
    • Ammann, D.1
  • 25
    • 84878353788 scopus 로고    scopus 로고
    • Artificial neural network modeling of p-cresol photodegradation
    • Abdollahi, Y. et al. Artificial neural network modeling of p-cresol photodegradation. Chem. Cent. J. 7, 1-7 (2013).
    • (2013) Chem. Cent. J. , vol.7 , pp. 1-7
    • Abdollahi, Y.1
  • 26
    • 55349107780 scopus 로고    scopus 로고
    • Modeling and optimization of heterogeneous photo-fenton process with response surface methodology and artificial neural networks
    • Kasiri, M., Aleboyeh, H. & Aleboyeh, A. Modeling and optimization of heterogeneous photo-fenton process with response surface methodology and artificial neural networks. Environ Sci. Technol. 42, 7970-7975 (2008).
    • (2008) Environ Sci. Technol. , vol.42 , pp. 7970-7975
    • Kasiri, M.1    Aleboyeh, H.2    Aleboyeh, A.3
  • 27
    • 84956088296 scopus 로고
    • Recommended for nomenclature of ion-selective electrodes
    • IUPAC. Analytical Chemistry Division Commission on Analytical Nomenclature
    • IUPAC. Analytical Chemistry Division, Commission on Analytical Nomenclature, Recommended for nomenclature of ion-selective electrodes. Pure Appl. Chem. 48, 127-135 (1976).
    • (1976) Pure Appl. Chem. , vol.48 , pp. 127-135
  • 28
    • 34250205601 scopus 로고    scopus 로고
    • 2 nanoparticles (anatase, brookite and rutile): Thermohydrolysis and oxidation in aqueous medium
    • DOI 10.1016/j.jpcs.2007.02.020, PII S0022369707000911, 7th International Conference of Solids State Chemistry 2006 (SSC 2006)
    • Cassaignon, S., Koelsch, M. & Jolivet, J. P. From TiCl3 to TiO2 nanoparticles (anatase, brookite and rutile): Thermohydrolysis and oxidation in aqueous medium. J. Phys. Chem. Solids. 68, 695-700 (2007). (Pubitemid 46907155)
    • (2007) Journal of Physics and Chemistry of Solids , vol.68 , Issue.5-6 , pp. 695-700
    • Cassaignon, S.1    Koelsch, M.2    Jolivet, J.-P.3
  • 29
    • 84860567480 scopus 로고    scopus 로고
    • Immobilization of tris (2 pyridyl)methylamine in PVC-membrane sensor and characterization of the membrane properties
    • Rezayi,M. et al. Immobilization of tris (2 pyridyl)methylamine in PVC-membrane sensor and characterization of the membrane properties. Chem Cent J 6, 40 (2012).
    • (2012) Chem Cent J , vol.6 , pp. 40
    • Rezayi, M.1
  • 30
    • 84876596105 scopus 로고
    • Selectivity coefficients for ion-selective electrodes: Recommended methods for reporting Kpota, B Values
    • Umezawa, Y., Umezawa, K. & Sato, H. Selectivity coefficients for ion-selective electrodes: recommended methods for reporting Kpota, B Values. Pure and applied chemistry. 67, 507-518 (1995).
    • (1995) Pure and Applied Chemistry. , vol.67 , pp. 507-518
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3
  • 32
    • 67649378642 scopus 로고    scopus 로고
    • Comparative studies of neodymium (III)-selective PVCmembrane sensors
    • Gupta, V. K., Goyal, R. N. & Sharma, R. A. Comparative studies of neodymium (III)-selective PVCmembrane sensors. Analytica Chimica Acta 647, 66-71 (2009).
    • (2009) Analytica Chimica Acta , vol.647 , pp. 66-71
    • Gupta, V.K.1    Goyal, R.N.2    Sharma, R.A.3
  • 33
    • 0036322261 scopus 로고    scopus 로고
    • Potentiometric selectivity coefficients of ion-selective electrodes Part II. Inorganic anions
    • Umezawa, Y. et al. Potentiometric selectivity coefficients of ion-selective electrodes Part II. Inorganic anions. Pure Appl. Chem. 74, 923-994 (2002).
    • (2002) Pure Appl. Chem. , vol.74 , pp. 923-994
    • Umezawa, Y.1
  • 34
    • 0034653614 scopus 로고    scopus 로고
    • Selectivity of potentiometric ion sensors
    • DOI 10.1021/ac991146n
    • Bakker, E., Pretsch, E. & Bühlmann, P. Selectivity of potentiometric ion sensors. Anal. Chem. 72, 1127-1133 (2000). (Pubitemid 30163765)
    • (2000) Analytical Chemistry , vol.72 , Issue.6 , pp. 1127-1133
    • Bakker, E.1    Pretsch, E.2    Buhlmann, P.3
  • 35
    • 0001446516 scopus 로고    scopus 로고
    • A chloride ion-selective solvent polymeric membrane electrode based on a hydrogen bond forming ionophore
    • Xiao, K. P., Bühlmann, P., Nishizawa, S., Amemiya, S. & Umezawa, Y. A chloride ion-selective solvent polymeric membrane electrode based on a hydrogen bond forming ionophore. Anal. Chem. 69, 1038-1044 (1997).
    • (1997) Anal. Chem. , vol.69 , pp. 1038-1044
    • Xiao, K.P.1    Bühlmann, P.2    Nishizawa, S.3    Amemiya, S.4    Umezawa, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.