메뉴 건너뛰기




Volumn 105, Issue 2, 2005, Pages 127-131

Novel triiodide ion-selective polymeric membrane sensor based on mercury-salen

Author keywords

N,N bis salicylidene 1,2 ethylendiamine; Potentiometry; PVC membrane; Triiodide selective electrode

Indexed keywords

BENZENE; ELECTRODES; IODINE COMPOUNDS; ION SELECTIVE MEMBRANES; MERCURY (METAL); NEGATIVE IONS; PH EFFECTS; POLYMERIC MEMBRANES; POLYVINYL CHLORIDES; TITRATION;

EID: 14744288699     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(03)00625-7     Document Type: Article
Times cited : (23)

References (22)
  • 1
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes: 2. Ionophores for potentiometric sensors
    • Buhlmann P., Pretsch E., Bakker E. Carrier-based ion-selective electrodes and bulk optodes: 2. Ionophores for potentiometric sensors. Chem. Rev. 98:1998;1593-1687
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Buhlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 2
    • 1542656822 scopus 로고
    • Chemical sensors 1997/1998-ion sensors
    • Buhlmann P. Chemical sensors 1997/1998-ion sensors. Chem. Sens. 14:1988;93-109
    • (1988) Chem. Sens. , vol.14 , pp. 93-109
    • Buhlmann, P.1
  • 3
    • 0032701533 scopus 로고    scopus 로고
    • Thiocyanate-selective electrodes based on nickel and iron phthalocyanines
    • Amini M.K., Shahrokhian S., Tangestaninejad S. Thiocyanate-selective electrodes based on nickel and iron phthalocyanines. Anal. Chim. Acta. 402:1999;137-143
    • (1999) Anal. Chim. Acta , vol.402 , pp. 137-143
    • Amini, M.K.1    Shahrokhian, S.2    Tangestaninejad, S.3
  • 4
    • 0035387928 scopus 로고    scopus 로고
    • A Schiff base complex of Zn (II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion
    • Shamsipur M., Yousefi M., Hosseini M., Ganjali M.R., Sharghi H., Naemi H. A Schiff base complex of Zn (II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion. Anal. Chem. 73:2001;2869-2874
    • (2001) Anal. Chem. , vol.73 , pp. 2869-2874
    • Shamsipur, M.1    Yousefi, M.2    Hosseini, M.3    Ganjali, M.R.4    Sharghi, H.5    Naemi, H.6
  • 6
    • 0032586093 scopus 로고    scopus 로고
    • Thiocyanate-selective PVC membrane electrodes based on Mn (II) complex of n,n-bis-(4-phenylazosalicylidene) o-phenylene diamine as a neutral carrier
    • Li Z.Q., Wu Z.Y., Yuan R., Ying M., Shen G.L., Yu R.Q. Thiocyanate-selective PVC membrane electrodes based on Mn (II) complex of n,n-bis-(4-phenylazosalicylidene) o-phenylene diamine as a neutral carrier. Electrochim. Acta. 44:1999;2543-2548
    • (1999) Electrochim. Acta , vol.44 , pp. 2543-2548
    • Li, Z.Q.1    Wu, Z.Y.2    Yuan, R.3    Ying, M.4    Shen, G.L.5    Yu, R.Q.6
  • 7
    • 0033105171 scopus 로고    scopus 로고
    • An ion-selective for acetate based on a urea-functionalized porphyrin as a hydrogen-bonding ionophore
    • Amemiya S., Buhlmann P., Umezawa Y., Jagessar R.C., Burns D.H. An ion-selective for acetate based on a urea-functionalized porphyrin as a hydrogen-bonding ionophore. Anal. Chem. 71:1999;1049-1054
    • (1999) Anal. Chem. , vol.71 , pp. 1049-1054
    • Amemiya, S.1    Buhlmann, P.2    Umezawa, Y.3    Jagessar, R.C.4    Burns, D.H.5
  • 8
    • 0030666176 scopus 로고    scopus 로고
    • Highly selective iodide poly (vinyl chloride) membrane electrode based on a nickel (II) tetraazaannulene macrocyclic complex
    • Ying M., Yuan R., Zhang X.M., Song Y.Q., Li Z.q., Shen G.l., Yu R.Q. Highly selective iodide poly (vinyl chloride) membrane electrode based on a nickel (II) tetraazaannulene macrocyclic complex. Analyst. 122:1997;1143-1146
    • (1997) Analyst , vol.122 , pp. 1143-1146
    • Ying, M.1    Yuan, R.2    Zhang, X.M.3    Song, Y.Q.4    Li, Z.Q.5    Shen, G.L.6    Yu, R.Q.7
  • 9
    • 84996049830 scopus 로고
    • Triiodide ion-selective electrode based on manganese (III)- tetraphenylporphine
    • Suzuki H., Nakagawa H., Mifune M., Saito Y. Triiodide ion-selective electrode based on manganese (III)-tetraphenylporphine. Anal. Sci. 9:1993;351-354
    • (1993) Anal. Sci. , vol.9 , pp. 351-354
    • Suzuki, H.1    Nakagawa, H.2    Mifune, M.3    Saito, Y.4
  • 10
    • 0033119633 scopus 로고    scopus 로고
    • Triiodide PVC membrane electrode based on a charged-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8-tetraazabicyclo [3.3.0] octane
    • Rouhollahi A., Shamsipur M. Triiodide PVC membrane electrode based on a charged-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8- tetraazabicyclo [3.3.0] octane. Anal. Chem. 71:1999;1350-1353
    • (1999) Anal. Chem. , vol.71 , pp. 1350-1353
    • Rouhollahi, A.1    Shamsipur, M.2
  • 11
    • 0037146483 scopus 로고    scopus 로고
    • Highly selective triiodide polymeric membrane electrode based on tetra(p-chlorophenyl) porphyrinato manganese (III) acetate
    • Farhadi K., Shaikhlouei H., Maleki R., Sharghi H., Shamsipur M. Highly selective triiodide polymeric membrane electrode based on tetra(p-chlorophenyl) porphyrinato manganese (III) acetate. Bull. Korean Chem. Soc. 23:2002;1635-1639
    • (2002) Bull. Korean Chem. Soc. , vol.23 , pp. 1635-1639
    • Farhadi, K.1    Shaikhlouei, H.2    Maleki, R.3    Sharghi, H.4    Shamsipur, M.5
  • 12
    • 0036479918 scopus 로고    scopus 로고
    • Clotrimazole-triiodide ion association as an ion exchanger for a triiodide ion-selective electrode
    • Farhadi K., Maleki R. Clotrimazole-triiodide ion association as an ion exchanger for a triiodide ion-selective electrode. Anal. Sci. 18:2002;133-136
    • (2002) Anal. Sci. , vol.18 , pp. 133-136
    • Farhadi, K.1    Maleki, R.2
  • 13
    • 33751096212 scopus 로고    scopus 로고
    • Tetrachlorophenylporphyrinato manganese(III) acetate as a new ionophore for a coated triiodide ion-selective electrode
    • Farhadi K., Shaikhlouei Bonab H., Maleki R., Shamsipur M., Sharghi H. Tetrachlorophenylporphyrinato manganese(III) acetate as a new ionophore for a coated triiodide ion-selective electrode. J. Chin. Chem. Soc. 49:2002;861-866
    • (2002) J. Chin. Chem. Soc. , vol.49 , pp. 861-866
    • Farhadi, K.1    Shaikhlouei Bonab, H.2    Maleki, R.3    Shamsipur, M.4    Sharghi, H.5
  • 14
    • 0036305008 scopus 로고    scopus 로고
    • Triiodide ion-selective polymeric membrane electrode based on a keoconazole-riiodide ion pair
    • Farhadi K., Maleki R., Shamsipur M. Triiodide ion-selective polymeric membrane electrode based on a keoconazole-riiodide ion pair. Electroanalysis. 11:2002;760-766
    • (2002) Electroanalysis , vol.11 , pp. 760-766
    • Farhadi, K.1    Maleki, R.2    Shamsipur, M.3
  • 15
    • 0032535504 scopus 로고    scopus 로고
    • Beryllium-selective membrane electrode based on benzo-9-crown-3
    • Ganjali M.R., Moghimi A., Shamsipur M. Beryllium-selective membrane electrode based on benzo-9-crown-3. Anal. Chem. 70:1998;5259-5263
    • (1998) Anal. Chem. , vol.70 , pp. 5259-5263
    • Ganjali, M.R.1    Moghimi, A.2    Shamsipur, M.3
  • 16
    • 0033321955 scopus 로고    scopus 로고
    • Zinc-selective membrane potentiometric sensor based on a recently synthesized benzo-substituted macrocyclic diamide
    • Shamsipur M., Rouhani S., Ganjali M.R., Eshghi H., Sharghi H. Zinc-selective membrane potentiometric sensor based on a recently synthesized benzo-substituted macrocyclic diamide. Sens. Actuators B. 59:1999;30-34
    • (1999) Sens. Actuators B , vol.59 , pp. 30-34
    • Shamsipur, M.1    Rouhani, S.2    Ganjali, M.R.3    Eshghi, H.4    Sharghi, H.5
  • 17
    • 0024106504 scopus 로고    scopus 로고
    • Copper (II)-selective electrode using thiuram disufide neutral carrier
    • Kamata S., Bhale A., Fukunaga Y., Murata A. Copper (II)-selective electrode using thiuram disufide neutral carrier. Anal. Chem. 60:1998;2464-2467
    • (1998) Anal. Chem. , vol.60 , pp. 2464-2467
    • Kamata, S.1    Bhale, A.2    Fukunaga, Y.3    Murata, A.4
  • 18
    • 4544366331 scopus 로고    scopus 로고
    • Carrier based ion-selective electrodes and optodes: 1. General characteristics
    • Bakker E., Buhlmann P., Pretsch E. Carrier based ion-selective electrodes and optodes: 1. General characteristics. Chem. Rev. 97:1997;3083-3132
    • (1997) Chem. Rev. , vol.97 , pp. 3083-3132
    • Bakker, E.1    Buhlmann, P.2    Pretsch, E.3
  • 19
    • 0001412096 scopus 로고
    • Contribution of membrane components to the overall response of anion carrier-based solvent polymeric membrane ion-selective electrodes
    • Hodinar A., Jyo A. Contribution of membrane components to the overall response of anion carrier-based solvent polymeric membrane ion-selective electrodes. Anal. Chem. 61:1989;1169-1171
    • (1989) Anal. Chem. , vol.61 , pp. 1169-1171
    • Hodinar, A.1    Jyo, A.2
  • 20
    • 0033653206 scopus 로고    scopus 로고
    • Nickel (II) ion selective electrode based on 2-methyl-4-(4-mthoxy phenyl)-2,6-diphenyl-2h-thiopyran
    • Ganjali M.R., Fathi M.R., Rahmani S., Pirelahi H. Nickel (II) ion selective electrode based on 2-methyl-4-(4-mthoxy phenyl)-2,6-diphenyl-2h- thiopyran. Electroanalysis. 12:2000;1138-1142
    • (2000) Electroanalysis , vol.12 , pp. 1138-1142
    • Ganjali, M.R.1    Fathi, M.R.2    Rahmani, S.3    Pirelahi, H.4
  • 21
    • 84956088296 scopus 로고
    • Recommended for nomenclature of ion-selective electrodes
    • IUPAC Analytical Chemistry Division, Commission on Analytical Nomenclature, Recommended for nomenclature of ion-selective electrodes, Pure. Appl. Chem. 48 (1976) 127-135.
    • (1976) Pure. Appl. Chem. , vol.48 , pp. 127-135
  • 22
    • 84876596105 scopus 로고
    • Selectivity coefficients for ion-selective electrode: Recommended methods for reporting K values
    • Umezawa Y., Umezawa K., Sato H. Selectivity coefficients for ion-selective electrode: recommended methods for reporting K values. Pure. Appl. Chem. 67:1995;507-518
    • (1995) Pure. Appl. Chem. , vol.67 , pp. 507-518
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.