메뉴 건너뛰기




Volumn 20, Issue 6, 2013, Pages 1998-2008

Reliability assessment of insulation system for dry type transformers

Author keywords

Degree of polymerization; Dry type transformer insulation; Partial discharge; Photomicrograph; Reliability assessment

Indexed keywords

PARTIAL DISCHARGES; POLYMERIZATION; RELIABILITY ANALYSIS; STRESSES; TESTING; THERMAL INSULATION;

EID: 84898424580     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2013.6678847     Document Type: Article
Times cited : (24)

References (28)
  • 1
    • 0028465075 scopus 로고
    • Thermal considerations in specifying dry-type transformers
    • L. W. Pierce, "Thermal considerations in specifying dry-type transformers", IEEE Trans. Ind. Appl., Vol. 30, No. 4, pp. 1090-1098, 1994.
    • (1994) IEEE Trans. Ind. Appl. , vol.30 , Issue.4 , pp. 1090-1098
    • Pierce, L.W.1
  • 2
    • 79958830490 scopus 로고    scopus 로고
    • Remaining lifetime modeling of power transformers: Individual assets and fleets
    • P. A. A. F. Wouters, A. van Schijndel, and J. M. Wetzer, "Remaining lifetime modeling of power transformers: individual assets and fleets", IEEE Electr. Insul. Mag., Vol. 27, No. 3, pp. 45-51, 2011.
    • (2011) IEEE Electr. Insul. Mag. , vol.27 , Issue.3 , pp. 45-51
    • Wouters, P.A.A.F.1    Van Schijndel, A.2    Wetzer, J.M.3
  • 4
    • 84898437376 scopus 로고
    • Aging evaluation of dry-type transformer insulation system
    • H. C. Stewart, L. C. Whitman, and A. L. Scheideler. "Aging evaluation of dry-type transformer insulation system", IEEE Trans. Power App. Syst., Vol. 72, No. 2, pp. 267-277, 1953.
    • (1953) IEEE Trans. Power App. Syst. , vol.72 , Issue.2 , pp. 267-277
    • Stewart, H.C.1    Whitman, L.C.2    Scheideler, A.L.3
  • 5
    • 84898416050 scopus 로고
    • A study of models for use in evaluating dry-type transformer insulation systems
    • T. R. Walters and A. L. Scheideler. "A study of models for use in evaluating dry-type transformer insulation systems", IEEE Trans. Power App. Syst., Vol. 75, no. 3, pp. 520-527, 1956.
    • (1956) IEEE Trans. Power App. Syst. , vol.75 , Issue.3 , pp. 520-527
    • Walters, T.R.1    Scheideler, A.L.2
  • 6
    • 84898424916 scopus 로고
    • Aging characteristics of dry-type transformer insulation at high temperature
    • H. C. Stewart and L. C. Whitman. "Aging characteristics of dry-type transformer insulation at high temperature", Trans. Amer. Inst. Electr. Eng., Trans., Vol. 67, No. 2, pp. 1600-1607, 1948.
    • (1948) Trans. Amer. Inst. Electr. Eng., Trans. , vol.67 , Issue.2 , pp. 1600-1607
    • Stewart, H.C.1    Whitman, L.C.2
  • 7
    • 70350570563 scopus 로고
    • Hot-spot temperatures in dry-type transformer windings
    • H. C. Stewart and L. C. Whitman. "Hot-spot temperatures in dry-type transformer windings", Trans. Amer. Inst. Electr. Eng., Trans., Vol. 63, No. 10, pp. 763-768, 1944.
    • (1944) Trans. Amer. Inst. Electr. Eng., Trans. , vol.63 , Issue.10 , pp. 763-768
    • Stewart, H.C.1    Whitman, L.C.2
  • 8
    • 0028407194 scopus 로고
    • Prediction hottest spot temperatures in ventilated dry type transformer windings
    • L. W. Pierce. "Prediction hottest spot temperatures in ventilated dry type transformer windings", IEEE Trans. Power Del., Vol.9, No. 2, pp. 1160-1172, 1994.
    • (1994) IEEE Trans. Power Del. , vol.9 , Issue.2 , pp. 1160-1172
    • Pierce, L.W.1
  • 10
    • 84865438557 scopus 로고    scopus 로고
    • A perspective on online partial discharge monitoring for assessment of the condition of rotating machine stator winding insulation
    • G. C. Stone, "A perspective on online partial discharge monitoring for assessment of the condition of rotating machine stator winding insulation", IEEE Electr. Insul. Mag., Vol. 28, No. 5, pp.8-13, 2012.
    • (2012) IEEE Electr. Insul. Mag. , vol.28 , Issue.5 , pp. 8-13
    • Stone, G.C.1
  • 11
    • 79958836050 scopus 로고    scopus 로고
    • Ph.D. Dissertation, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
    • A. Van Schijndel, Power Transformer Reliability Modeling, Ph.D. Dissertation, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands, 2010.
    • (2010) Power Transformer Reliability Modeling
    • Van Schijndel, A.1
  • 13
    • 77957899991 scopus 로고    scopus 로고
    • Behavior of machine insulation systems subjected to accelerated thermal aging test
    • M. Farahani, E. Gockenbach, and H. Borsi, "Behavior of machine insulation systems subjected to accelerated thermal aging test", IEEE Trans. Dielectr. Electr. Insul., Vol. 17, No. 5, pp.1364-1372, 2010.
    • (2010) IEEE Trans. Dielectr. Electr. Insul. , vol.17 , Issue.5 , pp. 1364-1372
    • Farahani, M.1    Gockenbach, E.2    Borsi, H.3
  • 15
    • 13844256702 scopus 로고    scopus 로고
    • A generalized growing and pruning RBF (GGAP-RBF) neural network for function approximation
    • G. Huang, P. Saratchandran, and N. Sundararajan, "A generalized growing and pruning RBF (GGAP-RBF) neural network for function approximation", IEEE Trans. Neural Networks, Vol. 16, No. 1, pp. 1929-1934, 2005.
    • (2005) IEEE Trans. Neural Networks , vol.16 , Issue.1 , pp. 1929-1934
    • Huang, G.1    Saratchandran, P.2    Sundararajan, N.3
  • 16
    • 78651500131 scopus 로고    scopus 로고
    • Feature extraction of partial discharge signals using the wavelet packet transform and classification with a probabilistic neural network
    • D. Evagorou, A. Kyprianou, P. L. Lewin, A. Stavrou, V. Efthymiou, A. C. Metaxas, and G. E. Georghiou "Feature extraction of partial discharge signals using the wavelet packet transform and classification with a probabilistic neural network", IET Sci. Measurement Technology (UK), Vol. 4, No. 3, pp. 177-192, 2010.
    • (2010) IET Sci. Measurement Technology (UK) , vol.4 , Issue.3 , pp. 177-192
    • Evagorou, D.1    Kyprianou, A.2    Lewin, P.L.3    Stavrou, A.4    Efthymiou, V.5    Metaxas, A.C.6    Georghiou, G.E.7
  • 17
    • 77549083026 scopus 로고    scopus 로고
    • Artificial identification system for transformer insulation aging
    • C.-C. Kuo, "Artificial identification system for transformer insulation aging", Expert Systems with Applications, Vol. 37, pp. 4190-4197, 2010.
    • (2010) Expert Systems with Applications , vol.37 , pp. 4190-4197
    • Kuo, C.-C.1
  • 19
    • 0034204541 scopus 로고    scopus 로고
    • A three-phase multi-stress accelerated electrical aging test facility for stator bars
    • R. Morin, R. Bartnikas, and P. Ménard, "A three-phase multi-stress accelerated electrical aging test facility for stator bars", IEEE Trans. Enegry Conversion, Vol. 15, No. 2, pp. 149-156, 2000.
    • (2000) IEEE Trans. Enegry Conversion , vol.15 , Issue.2 , pp. 149-156
    • Morin, R.1    Bartnikas, R.2    Ménard, P.3
  • 20
    • 78449252934 scopus 로고    scopus 로고
    • Fabrication of electrospun meta-aramid nanofibers in different solvent systems
    • L. Yao, C. Lee, and J. Kim, "Fabrication of electrospun meta-aramid nanofibers in different solvent systems", Fibers and Polymers, Vol. 11, No. 7, pp. 1032-1040, 2010.
    • (2010) Fibers and Polymers , vol.11 , Issue.7 , pp. 1032-1040
    • Yao, L.1    Lee, C.2    Kim, J.3
  • 21
    • 0018453628 scopus 로고
    • Solution and rheological properties of poly(m-phenyleneisophthalamide) in dimethylacetamide/licl
    • DOI 10.1002/app.1979.070230726
    • D. Harwood, H. Aoki, Y. D. Lee, J. F. Fellers, and J. L. White. "Solution and Rheological Properties of Poly(m-phenyleneisophthalamide) in Dimethylacetamide/LiCl", J. Appl. Polymer Sci., Vol. 23, pp. 2155-2168, 1979. (Pubitemid 9430307)
    • (1979) J Appl Polym Sci , vol.23 , Issue.7 , pp. 2155-2168
    • Harwood Daniel1    Aoki Hiroshi2    Lee Yu-Der3    Fellers John, F.4    White James, L.5
  • 23
    • 1342329446 scopus 로고    scopus 로고
    • Raman spectroscopy-A technique to assess the residual stress in fiber-reinforced polymeric insulation materials
    • H.-Z. Ding and B. R. Varlow, "Raman spectroscopy-a technique to assess the residual stress in fiber-reinforced polymeric insulation materials", IEEE Electr. Insul. Mag., Vol. 20, No. 1, pp. 5-13, 2004.
    • (2004) IEEE Electr. Insul. Mag. , vol.20 , Issue.1 , pp. 5-13
    • Ding, H.-Z.1    Varlow, B.R.2
  • 24
    • 14544274480 scopus 로고    scopus 로고
    • Thermodynamic model for electrical tree propagation kinetics in combined electrical and mechanical Stresses
    • H.-Z. Ding and B. R. Varlow, "Thermodynamic model for electrical tree propagation kinetics in combined electrical and mechanical Stresses" IEEE Trans. Dielectr. Electr. Insul., Vol. 12, No. 1, pp. 81-89, 2005.
    • (2005) IEEE Trans. Dielectr. Electr. Insul. , vol.12 , Issue.1 , pp. 81-89
    • Ding, H.-Z.1    Varlow, B.R.2
  • 25
    • 0028401069 scopus 로고
    • A kinetic model of timedependent dielectric breakdown for polymers
    • H.-Z. Ding, X. -S. Xing and H.-S. Zhu, "A kinetic model of timedependent dielectric breakdown for polymers", J. Phys. D: Appl. Phys., Vol. 27, pp. 591-595, 1994.
    • (1994) J. Phys. D: Appl. Phys. , vol.27 , pp. 591-595
    • Ding, H.-Z.1    Xing, X.-S.2    Zhu, H.-S.3
  • 26
    • 0025495891 scopus 로고
    • Models for insulation aging under electrical and thermal multistress
    • P. Cygan and J. R. Laghari. "Models for Insulation Aging under Electrical and Thermal Multistress", IEEE Trans. Electr. Insul. Vol.25. No. 5, 1990, pp. 923-934.
    • (1990) IEEE Trans. Electr. Insul. , vol.25 , Issue.5 , pp. 923-934
    • Cygan, P.1    Laghari, J.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.