메뉴 건너뛰기




Volumn , Issue , 2012, Pages 293-300

Calculation of the remaining lifetime of power transformers paper insulation

Author keywords

[No Author keywords available]

Indexed keywords

ASSET MANAGERS; DECISION MAKING PROCESS; FAULT PROBABILITIES; FURFURAL ANALYSIS; LIFETIME CALCULATION; PAPER DEGRADATION; PAPER INSULATION; PROBABILISTIC APPROACHES;

EID: 84864647024     PISSN: 18420133     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/OPTIM.2012.6231792     Document Type: Conference Paper
Times cited : (36)

References (23)
  • 1
    • 79958836050 scopus 로고    scopus 로고
    • PhD. Dissertation, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
    • A. van Schijndel, "Power Transformer Reliability Modelling", PhD. Dissertation, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands, 2010.
    • (2010) Power Transformer Reliability Modelling
    • Van Schijndel, A.1
  • 3
    • 33645822324 scopus 로고    scopus 로고
    • Cellulose insulation in oil-filled power transformers: Part II - Maintaining insulation integrity and life
    • T. V. Oommen, Thomas A. Prevost, "Cellulose Insulation in Oil-Filled Power Transformers: Part II - Maintaining Insulation Integrity and Life", IEEE Electrical Insulation Magazine, vol. 22, no. 2, pp. 5-14, 2006.
    • (2006) IEEE Electrical Insulation Magazine , vol.22 , Issue.2 , pp. 5-14
    • Oommen, T.V.1    Prevost, T.A.2
  • 5
    • 84870006107 scopus 로고    scopus 로고
    • The aging diagnosis of solid insulation for oil-immersed power transformers and its remaining life prediction
    • Lin Chaohui, Zhang Bide, Yuan Yuchun, "The Aging Diagnosis of Solid Insulation for Oil-Immersed Power Transformers and Its Remaining Life Prediction", Asia-Pacific Power and Energy Engineering Conference (APPEEC), pp. 1-3, 2010.
    • (2010) Asia-pacific Power and Energy Engineering Conference (APPEEC) , pp. 1-3
    • Lin, C.1    Bide, Z.2    Yuan, Y.3
  • 6
    • 49649106978 scopus 로고    scopus 로고
    • Asset-management of transformers based on condition monitoring and standard diagnosis
    • X. Zhang, E. Gockenbach, "Asset-Management of Transformers Based on Condition Monitoring and Standard Diagnosis", IEEE Electrical Insulation Magazine, vol. 24, no. 4, pp. 26-40, 2008.
    • (2008) IEEE Electrical Insulation Magazine , vol.24 , Issue.4 , pp. 26-40
    • Zhang, X.1    Gockenbach, E.2
  • 8
    • 65249126352 scopus 로고    scopus 로고
    • An approach to power transformer asset management using health index
    • J. R. R. Service
    • A. N. Jahromi, R. Piercy, S. Cress, J. R. R. Service and W. Fan, "An Approach to Power Transformer Asset Management using Health Index", IEEE Electrical Insulation Magazine, vol. 25, no. 2, pp. 20-34, 2009.
    • (2009) IEEE Electrical Insulation Magazine , vol.25 , Issue.2 , pp. 20-34
    • Jahromi, A.N.1    Piercy, R.2    Cress, S.3    Fan, W.4
  • 9
    • 33947256235 scopus 로고    scopus 로고
    • Cellulose insulation in oil-filled power transformers: Part I-history and development
    • T. A. Prevost, T. V. Oommen, "Cellulose insulation in oil-filled power transformers: part I-history and development", IEEE Electrical Insulation Magazine, vol. 22, no. 1, pp. 28-35, 2006.
    • (2006) IEEE Electrical Insulation Magazine , vol.22 , Issue.1 , pp. 28-35
    • Prevost, T.A.1    Oommen, T.V.2
  • 11
    • 79953663132 scopus 로고    scopus 로고
    • Applicability of methanol as a new marker for paper degradation in power transformers
    • Annelore Schaut, Stijn Autru, and Steve Eeckhoudt, "Applicability of Methanol as a New Marker for Paper Degradation in Power Transformers", IEEE Transactions on Dielectrics and Electrical Insulation, vol. 18, no. 2, pp. 533-540, 2011.
    • (2011) IEEE Transactions on Dielectrics and Electrical Insulation , vol.18 , Issue.2 , pp. 533-540
    • Schaut, A.1    Autru, S.2    Eeckhoudt, S.3
  • 12
    • 79958830490 scopus 로고    scopus 로고
    • Remaining lifetime modeling of power transformers: Individual assets and fleets
    • May/June
    • P.A.A.F. Wouters, A. van Schijndel, J. M. Wetzer, "Remaining lifetime modeling of power transformers: individual assets and fleets", IEEE Electrical Insulation Magazine, vol. 27, no. 3, pp. 45-51, May/June 2011.
    • (2011) IEEE Electrical Insulation Magazine , vol.27 , Issue.3 , pp. 45-51
    • Wouters, P.A.A.F.1    Van Schijndel, A.2    Wetzer, J.M.3
  • 15
    • 0028496219 scopus 로고
    • Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers
    • A. M. Emsley, G. C. Stevens, "Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers", IEEE Proceedings Science, Measurement and Technology, vol. 141, no. 5, pp. 324-334, 1994.
    • (1994) IEEE Proceedings Science, Measurement and Technology , vol.141 , Issue.5 , pp. 324-334
    • Emsley, A.M.1    Stevens, G.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.