메뉴 건너뛰기




Volumn 28, Issue 5, 2012, Pages 8-13

A perspective on online partial discharge monitoring for assessment of the condition of rotating machine stator winding insulation

Author keywords

condition assessment; online; partial discharge; stator winding insulation

Indexed keywords

ABRASION PROCESS; AIR-GAPS; CABLE JOINT; CONDITION ASSESSMENTS; DIAGNOSTIC TESTS; ELECTRICAL EQUIPMENT; EQUIPMENT FAILURES; GAS INSULATED SWITCHGEARS; HIGH-VOLTAGE EQUIPMENTS; HIGH-VOLTAGES; INSULATION SYSTEM; MAGNETIC FORCE; MAINTENANCE OUTAGES; MANUFACTURING DEFECTS; MEASURING SYSTEMS; MECHANICAL STRESS; OIL-PAPERS; ON-LINE PARTIAL DISCHARGE; ONLINE; ONLINE METHODS; PARTIAL DISCHARGE TESTING; PD MEASUREMENTS; PD MONITORING; PD TEST; QUALITY CONTROL TOOL; ROTATING MACHINE; SLOT DISCHARGE; SOLID INSULATION SYSTEMS; STATOR CORE; STATOR SLOT; STATOR WINDING;

EID: 84865438557     PISSN: 08837554     EISSN: None     Source Type: Journal    
DOI: 10.1109/MEI.2012.6268437     Document Type: Review
Times cited : (91)

References (21)
  • 2
    • 0036817485 scopus 로고    scopus 로고
    • Partial discharges their mechanism, detection and measurement
    • DOI 10.1109/TDEI.2002.1038663
    • R. Bartnikas, "Partial discharges: Their mechanism, detection, and measurement," IEEE Trans. Dielectr. Electr. Insul., vol. 9, no. 5, pp. 763-808, 2002. (Pubitemid 35465655)
    • (2002) IEEE Transactions on Dielectrics and Electrical Insulation , vol.9 , Issue.5 , pp. 763-808
    • Bartnikas, R.1
  • 3
    • 28744457368 scopus 로고    scopus 로고
    • Partial discharge diagnostics and electrical equipment insulation condition assessment
    • DOI 10.1109/TDEI.2005.1522184
    • G. C. Stone, "Partial discharge diagnostics and electrical equipment insulation condition assessment," IEEE Trans. Dielectr. Electr. Insul., vol. 12, no. 5, pp. 891-904, 2005. (Pubitemid 41757789)
    • (2005) IEEE Transactions on Dielectrics and Electrical Insulation , vol.12 , Issue.5 , pp. 891-904
    • Stone, G.C.1
  • 4
    • 84938445596 scopus 로고
    • Detection of slot discharges in high-voltage stator windings during operation
    • J. S. Johnson and M. Warren, "Detection of slot discharges in high-voltage stator windings during operation," Trans. Am. Inst. Electr. Eng., vol. 70, no. 2, pp. 1998-2000, 1951.
    • (1951) Trans. Am. Inst. Electr. Eng. , vol.70 , Issue.2 , pp. 1998-2000
    • Johnson, J.S.1    Warren, M.2
  • 5
    • 84865437907 scopus 로고
    • Experience with slot discharge detection on generators
    • paper 24AC51
    • C. A. Duke and C. R. Goodroe, "Experience with slot discharge detection on generators," in Doble Client Conf., 1958, paper 24AC51.
    • (1958) Doble Client Conf.
    • Duke, C.A.1    Goodroe, C.R.2
  • 6
    • 0015774735 scopus 로고
    • A partial discharge test for generator insulation
    • M. Kurtz, "A partial discharge test for generator insulation," Ontario Hydro Res. Q., vol. 25, no. 4, pp. 1-4, 1973.
    • (1973) Ontario Hydro Res. Q. , vol.25 , Issue.4 , pp. 1-4
    • Kurtz, M.1
  • 7
    • 0014638311 scopus 로고
    • A simple pulse height analyzer for pd rate measurements
    • R. Bartnikas and J. Levi, "A simple pulse height analyzer for PD rate measurements," IEEE Trans. Insrum. Meas., vol. 18, no. 4, pp. 341-345, 1969.
    • (1969) IEEE Trans. Insrum. Meas. , vol.18 , Issue.4 , pp. 341-345
    • Bartnikas, R.1    Levi, J.2
  • 8
    • 3743071286 scopus 로고
    • The functional testing of hv generator stator insulation
    • paper, Sep.
    • A. Kelen, "The functional testing of HV generator stator insulation," in Proc. CIGRE Conf., Paris, Sep. 1976, paper 15-03.
    • (1976) Proc. CIGRE Conf., Paris , pp. 15-03
    • Kelen, A.1
  • 9
    • 84865408238 scopus 로고
    • Pd pattern recognition as a tool for diagnosis and monitoring of aging
    • paper 15/Sep.
    • B. Fruth and J. Fuhr, "PD pattern recognition as a tool for diagnosis and monitoring of aging," Proc. CIGRE Conf., Paris, Sep. 1990, paper 15/33-12.
    • (1990) Proc. CIGRE Conf., Paris , pp. 33-12
    • Fruth, B.1    Fuhr, J.2
  • 12
    • 32144442689 scopus 로고    scopus 로고
    • Objective methods to interpret partial-discharge data on rotating-machine stator windings
    • DOI 10.1109/TIA.2005.861273
    • G. C. Stone and V. Warren, "Objective methods to interpret partial discharge data on rotating machine stator windings," IEEE Trans. Ind. Appl., vol. 42, no. 1, pp. 195-200, 2006. (Pubitemid 43204786)
    • (2006) IEEE Transactions on Industry Applications , vol.42 , Issue.1 , pp. 195-200
    • Stone, G.C.1    Warren, V.2
  • 13
    • 5044246962 scopus 로고    scopus 로고
    • Effect of manufacturer, winding age and insulation type on stator winding partial discharge levels
    • G. C. Stone and V. Warren, "Effect of manufacturer, winding age and insulation type on stator winding partial discharge levels," IEEE Electr. Insul. Mag., vol. 20, no. 5, pp. 13-17, 2004.
    • (2004) IEEE Electr. Insul. Mag. , vol.20 , Issue.5 , pp. 13-17
    • Stone, G.C.1    Warren, V.2
  • 14
    • 0021476651 scopus 로고
    • Application of partial discharge testing to hydro generator maintenance
    • M. Kurtz, J. F. Lyles, and G. C. Stone, "Application of partial discharge testing to hydro generator maintenance," IEEE Trans. Power Apparatus Syst., vol. PAS-103, no. 8, pp. 2148-2157, 1984.
    • (1984) IEEE Trans. Power Apparatus Syst. , vol.PAS-103 , Issue.8 , pp. 2148-2157
    • Kurtz, M.1    Lyles, J.F.2    Stone, G.C.3
  • 15
    • 0033890096 scopus 로고    scopus 로고
    • Importance of bandwidth in pd measurement in operating motors and generators
    • G. C. Stone, "Importance of bandwidth in PD measurement in operating motors and generators," IEEE Trans. Dielectr. Electr. Insul., vol. 7, no. 1, pp. 6-11, 2000.
    • (2000) IEEE Trans. Dielectr. Electr. Insul. , vol.7 , Issue.1 , pp. 6-11
    • Stone, G.C.1
  • 16
    • 82655166976 scopus 로고    scopus 로고
    • Guidelines for unconventional partial discharge measurements
    • CIGRE, Committee Report 2009, CIGRE WG D1.33
    • CIGRE, "Guidelines for unconventional partial discharge measurements," Committee Report 2009, CIGRE WG D1.33, Electra, 2010.
    • (2010) Electra
  • 19
    • 0037732564 scopus 로고    scopus 로고
    • Wavelet-based denoising of partial discharge signals buried in excessive noise and interference
    • L. Satish and B. Nazneen, "Wavelet-based denoising of partial discharge signals buried in excessive noise and interference," IEEE Trans. Dielectr. Electr. Insul., vol. 10, no. 2, pp. 354-367, 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul. , vol.10 , Issue.2 , pp. 354-367
    • Satish, L.1    Nazneen, B.2
  • 20
    • 0023526874 scopus 로고
    • Calibration difficulties associated with partial discharge detectors in rotating machine applications
    • Chicago, Oct.
    • I. J. Kemp, B. K. Gupta, and G. C. Stone, "Calibration difficulties associated with partial discharge detectors in rotating machine applications," in Proc. IEEE Electrical Insulation Conference, Chicago, Oct. 1987, p. 92.
    • (1987) Proc. IEEE Electrical Insulation Conference , pp. 92
    • Kemp, I.J.1    Gupta, B.K.2    Stone, G.C.3
  • 21
    • 34249752665 scopus 로고    scopus 로고
    • Partial discharge - A valuable stator winding evaluation tool
    • 1665339, Conference Record of the 2006 IEEE International Symposium on Electrical Insulation
    • C. V. Maughan, "Partial discharge -A valuable stator winding evaluation tool," in Proc. IEEE International Symposium on Electrical Insulation," June 2006, pp. 388-391. (Pubitemid 46823300)
    • (2007) Conference Record of IEEE International Symposium on Electrical Insulation , vol.2007 , pp. 388-391
    • Maughan, C.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.