메뉴 건너뛰기




Volumn 68, Issue , 2014, Pages 385-398

Automatic X-ray inspection for escaped coated particles in spherical fuel elements of high temperature gas-cooled reactor

Author keywords

Automatic recognition; Digital radiography; High temperature gas cooled reactors; Spherical fuel elements

Indexed keywords

FUEL GAGES; GAS COOLED REACTORS; HIGH TEMPERATURE GAS REACTORS; NUCLEAR FUEL ELEMENTS; SPHERES; X RAY RADIOGRAPHY; X RAYS;

EID: 84898028343     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2014.02.076     Document Type: Article
Times cited : (35)

References (46)
  • 1
    • 82555201482 scopus 로고    scopus 로고
    • Choosing a standard reactor: international competition and domestic politics in Chinese nuclear policy
    • Ramanaa M.V., Saikawab E. Choosing a standard reactor: international competition and domestic politics in Chinese nuclear policy. Energy 2011, 36:6779-6789.
    • (2011) Energy , vol.36 , pp. 6779-6789
    • Ramanaa, M.V.1    Saikawab, E.2
  • 2
    • 77957898603 scopus 로고    scopus 로고
    • Nuclear energy development in China: a study of opportunities and challenges
    • Zhou S., Zhang X.L. Nuclear energy development in China: a study of opportunities and challenges. Energy 2010, 35:4282-4288.
    • (2010) Energy , vol.35 , pp. 4282-4288
    • Zhou, S.1    Zhang, X.L.2
  • 3
    • 0025792708 scopus 로고
    • Present status of research and development for HTR in China
    • Wang D.Z., Zhong D.X., Xu Y.K. Present status of research and development for HTR in China. Energy 1991, 16:159-167.
    • (1991) Energy , vol.16 , pp. 159-167
    • Wang, D.Z.1    Zhong, D.X.2    Xu, Y.K.3
  • 4
    • 45449084395 scopus 로고    scopus 로고
    • Nuclear energy in China: contested regimes
    • Xu Y.C. Nuclear energy in China: contested regimes. Energy 2008, 33:1197-1205.
    • (2008) Energy , vol.33 , pp. 1197-1205
    • Xu, Y.C.1
  • 5
    • 84898031270 scopus 로고    scopus 로고
    • DOE. "Discussion on goals for generation IV nuclear power systems", from a workshop held on May 1-3, Bethesda, Maryland, USA.
    • DOE. "Discussion on goals for generation IV nuclear power systems", from a workshop held on May 1-3, Bethesda, Maryland, USA.
  • 6
    • 0036783508 scopus 로고    scopus 로고
    • Design and manufacture of the fuel element for the 10MW high temperature gas-cooled reactor
    • Tang C.H., Tang Y.P., Zhu J.G., Zou Y.W., Li J.H., Ni X.J. Design and manufacture of the fuel element for the 10MW high temperature gas-cooled reactor. Nucl Eng Des 2002, 218:91-102.
    • (2002) Nucl Eng Des , vol.218 , pp. 91-102
    • Tang, C.H.1    Tang, Y.P.2    Zhu, J.G.3    Zou, Y.W.4    Li, J.H.5    Ni, X.J.6
  • 7
    • 0034268742 scopus 로고    scopus 로고
    • Research and development of fuel element for Chinese 10MW high temperature gas-cooled reactor
    • Tang C.H., Tang Y.P., Zhu J.G., Qiu X.L., Li J.H., Xu S.J. Research and development of fuel element for Chinese 10MW high temperature gas-cooled reactor. JNucl Sci Technol 2000, 37:802-806.
    • (2000) JNucl Sci Technol , vol.37 , pp. 802-806
    • Tang, C.H.1    Tang, Y.P.2    Zhu, J.G.3    Qiu, X.L.4    Li, J.H.5    Xu, S.J.6
  • 9
    • 0025786351 scopus 로고
    • Evolution of HTGR coated particle fuel design
    • Stansfield M. Evolution of HTGR coated particle fuel design. Energy 1991, 16:33-45.
    • (1991) Energy , vol.16 , pp. 33-45
    • Stansfield, M.1
  • 10
    • 0742284279 scopus 로고    scopus 로고
    • Fabrication of spherical fuel element 10MW high temperature gas-cooled reactor
    • He J., Zou Y.W., Qiu X.L., Liang T.X. Fabrication of spherical fuel element 10MW high temperature gas-cooled reactor. Atom Energy Sci Technol 2003, 37:40-44.
    • (2003) Atom Energy Sci Technol , vol.37 , pp. 40-44
    • He, J.1    Zou, Y.W.2    Qiu, X.L.3    Liang, T.X.4
  • 11
    • 55049137635 scopus 로고    scopus 로고
    • Nondestructive measurement of the coating thickness for simulated TRISO-coated fuel particles by using phase contrast X-ray radiography
    • Kim W.K., Lee Y.W., Cho M.S., Park J.Y., Ra S.W., Park J.B. Nondestructive measurement of the coating thickness for simulated TRISO-coated fuel particles by using phase contrast X-ray radiography. Nucl Eng Des 2008, 238:3285-3291.
    • (2008) Nucl Eng Des , vol.238 , pp. 3285-3291
    • Kim, W.K.1    Lee, Y.W.2    Cho, M.S.3    Park, J.Y.4    Ra, S.W.5    Park, J.B.6
  • 12
    • 0037314063 scopus 로고    scopus 로고
    • X-ray fluorescence microtomography study of trace elements in a SiC nuclear fuel shell
    • Naghedolfeizi M., Chung J.S., Morris R., Ice G.E., Yun W.B., Cai Z., et al. X-ray fluorescence microtomography study of trace elements in a SiC nuclear fuel shell. JNucl Mater 2003, 312:146-155.
    • (2003) JNucl Mater , vol.312 , pp. 146-155
    • Naghedolfeizi, M.1    Chung, J.S.2    Morris, R.3    Ice, G.E.4    Yun, W.B.5    Cai, Z.6
  • 13
    • 80052569984 scopus 로고    scopus 로고
    • Nondestructive measurement of the weight of kernels in a simulated cylindrical fuel compact for HTGR using X-ray computed tomography
    • Kim W.K., Lee Y.W., Cho M.S. Nondestructive measurement of the weight of kernels in a simulated cylindrical fuel compact for HTGR using X-ray computed tomography. Nucl Eng Des 2011, 241:3748-3752.
    • (2011) Nucl Eng Des , vol.241 , pp. 3748-3752
    • Kim, W.K.1    Lee, Y.W.2    Cho, M.S.3
  • 14
    • 0242607071 scopus 로고    scopus 로고
    • Non-destructive analysis of nuclear fuel by means of thermal and cold neutrons
    • Lehmann E.H., Vontobel P., Hermann A. Non-destructive analysis of nuclear fuel by means of thermal and cold neutrons. Nucl Instrum Methods Phys Res A 2003, 515:745-759.
    • (2003) Nucl Instrum Methods Phys Res A , vol.515 , pp. 745-759
    • Lehmann, E.H.1    Vontobel, P.2    Hermann, A.3
  • 15
    • 34249330334 scopus 로고    scopus 로고
    • Statistical image reconstruction for inconsistent CT projection data
    • Oehler M., Buzug T.M. Statistical image reconstruction for inconsistent CT projection data. Methods Inf Med 2007, 46:261-269.
    • (2007) Methods Inf Med , vol.46 , pp. 261-269
    • Oehler, M.1    Buzug, T.M.2
  • 16
    • 59449107042 scopus 로고    scopus 로고
    • Suppression of metal artifacts in CT using a reconstruction procedure that combines map and projection completion
    • Lemmens C., Faul D., Nuyts J. Suppression of metal artifacts in CT using a reconstruction procedure that combines map and projection completion. IEEE Trans Med Imaging 2009, 28:250-260.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 250-260
    • Lemmens, C.1    Faul, D.2    Nuyts, J.3
  • 17
    • 0036030338 scopus 로고    scopus 로고
    • Anovel method for reducing high attenuation object artifacts in CT reconstructions
    • Chen L.G., Liang Y., George A.S., Jonas R. Anovel method for reducing high attenuation object artifacts in CT reconstructions. Proc SPIE 2002, 4684:841-850.
    • (2002) Proc SPIE , vol.4684 , pp. 841-850
    • Chen, L.G.1    Liang, Y.2    George, A.S.3    Jonas, R.4
  • 18
    • 78649831027 scopus 로고    scopus 로고
    • 2 (carbon dioxide) flooding using micro-CT (micro-computed tomography) images of Berea sandstone core using finite element simulations
    • 2 (carbon dioxide) flooding using micro-CT (micro-computed tomography) images of Berea sandstone core using finite element simulations. Energy 2010, 35:5209-5216.
    • (2010) Energy , vol.35 , pp. 5209-5216
    • Gunde, A.C.1    Bera, B.2    Mitra, S.K.3
  • 19
    • 14344266358 scopus 로고    scopus 로고
    • Ahybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy
    • Xia D., Roeske J.C., Yu L.F., Pelizzari C.A., Mundt A.J., Pan X.C. Ahybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy. Brachytherapy 2002, 4:18-23.
    • (2002) Brachytherapy , vol.4 , pp. 18-23
    • Xia, D.1    Roeske, J.C.2    Yu, L.F.3    Pelizzari, C.A.4    Mundt, A.J.5    Pan, X.C.6
  • 20
  • 21
    • 82055165631 scopus 로고    scopus 로고
    • Automatic weld defect detection based on potential defect tracking in real-time radiographic image sequence
    • Shao J.X., Du D., Chang B.H., Shi H. Automatic weld defect detection based on potential defect tracking in real-time radiographic image sequence. NDT&E Int 2012, 46:14-21.
    • (2012) NDT&E Int , vol.46 , pp. 14-21
    • Shao, J.X.1    Du, D.2    Chang, B.H.3    Shi, H.4
  • 22
    • 65649130059 scopus 로고    scopus 로고
    • Application of X-ray digital radiography to online automated inspection of interior assembly structures of complex products
    • Han Y.P., Han Y., Li R.H., Wang L.M. Application of X-ray digital radiography to online automated inspection of interior assembly structures of complex products. Nucl Instrum Methods A 2009, 604:760-764.
    • (2009) Nucl Instrum Methods A , vol.604 , pp. 760-764
    • Han, Y.P.1    Han, Y.2    Li, R.H.3    Wang, L.M.4
  • 23
    • 17844380035 scopus 로고    scopus 로고
    • Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    • Cho Youngbin, Moseley Douglas J., Siewerdsen Jeffrey H., Jaffray David A. Accurate technique for complete geometric calibration of cone-beam computed tomography systems. Med Phys 2005, 32:968-983.
    • (2005) Med Phys , vol.32 , pp. 968-983
    • Cho, Y.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4
  • 25
    • 0036896595 scopus 로고    scopus 로고
    • Automatic identification of different types of welding defects in radiographic images
    • Wang G., Liao T.W. Automatic identification of different types of welding defects in radiographic images. NDT&E Int 2002, 35:519-528.
    • (2002) NDT&E Int , vol.35 , pp. 519-528
    • Wang, G.1    Liao, T.W.2
  • 26
    • 0030174686 scopus 로고    scopus 로고
    • An automated radiographic NDT system for weld inspection: part I - weld extraction
    • Liao T.W., Ni J.W. An automated radiographic NDT system for weld inspection: part I - weld extraction. NDT&E Int 1996, 29:157-162.
    • (1996) NDT&E Int , vol.29 , pp. 157-162
    • Liao, T.W.1    Ni, J.W.2
  • 27
    • 0023312960 scopus 로고
    • Automatic recognition of weld defects in X-ray inspection
    • Daum W., Rose P., Heidt H., Builtjes J.H. Automatic recognition of weld defects in X-ray inspection. Br J NDT 1987, 29:79-82.
    • (1987) Br J NDT , vol.29 , pp. 79-82
    • Daum, W.1    Rose, P.2    Heidt, H.3    Builtjes, J.H.4
  • 28
    • 84890122396 scopus 로고    scopus 로고
    • Denoising method of X-ray phase contrast DR image for TRISO-coated fuel particles
    • Yang M., Zhang J.H., Meng F.Y., Song S.J., Li X.D., Liu W.L., et al. Denoising method of X-ray phase contrast DR image for TRISO-coated fuel particles. Particuology 2013, 11:695-702.
    • (2013) Particuology , vol.11 , pp. 695-702
    • Yang, M.1    Zhang, J.H.2    Meng, F.Y.3    Song, S.J.4    Li, X.D.5    Liu, W.L.6
  • 29
    • 84882848186 scopus 로고    scopus 로고
    • Non-local means theory based Perona-Malik model for image denoising
    • Yang M., Liang J.K., Zhang J.H., Gao H.D., Meng F.Y., Li X.D., et al. Non-local means theory based Perona-Malik model for image denoising. Neurocomputing 2013, 120:262-267.
    • (2013) Neurocomputing , vol.120 , pp. 262-267
    • Yang, M.1    Liang, J.K.2    Zhang, J.H.3    Gao, H.D.4    Meng, F.Y.5    Li, X.D.6
  • 30
    • 66249139913 scopus 로고    scopus 로고
    • Afuzzy locally adaptive Bayesian segmentation approach for volume determination in PET
    • Hatt M., Le Rest C.C., Turzo A., Roux C., Visvikis D. Afuzzy locally adaptive Bayesian segmentation approach for volume determination in PET. IEEE Trans Med Imaging 2009, 28:881-893.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 881-893
    • Hatt, M.1    Le Rest, C.C.2    Turzo, A.3    Roux, C.4    Visvikis, D.5
  • 32
    • 0029324937 scopus 로고
    • An adaptive speckle suppression filter for medical ultrasonic imaging
    • Karaman M., Kutay M.A., Bozdagi G. An adaptive speckle suppression filter for medical ultrasonic imaging. IEEE Trans Med Imaging 1995, 14:283-292.
    • (1995) IEEE Trans Med Imaging , vol.14 , pp. 283-292
    • Karaman, M.1    Kutay, M.A.2    Bozdagi, G.3
  • 33
    • 80053550452 scopus 로고    scopus 로고
    • Automatic multilevel thresholding based two-stage OSTU's method with cluster determination by valley estimation
    • Huang D.Y., Lin T.W., Hu W.C. Automatic multilevel thresholding based two-stage OSTU's method with cluster determination by valley estimation. Int J Innov Comput Inf Control 2011, 7:5631-5644.
    • (2011) Int J Innov Comput Inf Control , vol.7 , pp. 5631-5644
    • Huang, D.Y.1    Lin, T.W.2    Hu, W.C.3
  • 35
    • 80052610689 scopus 로고    scopus 로고
    • Anew 3D information acquisition method of micro-drilling marks on ancient perforated stone bead through micro-CT
    • Yang M., Yang Y.M., Wang C.S. Anew 3D information acquisition method of micro-drilling marks on ancient perforated stone bead through micro-CT. JX-Ray Sci Technol 2011, 19:333-343.
    • (2011) JX-Ray Sci Technol , vol.19 , pp. 333-343
    • Yang, M.1    Yang, Y.M.2    Wang, C.S.3
  • 36
    • 0026136709 scopus 로고
    • Adirect method for least-square fitting
    • Moura L. Adirect method for least-square fitting. Comput Phys Commun 1991, 64:57-63.
    • (1991) Comput Phys Commun , vol.64 , pp. 57-63
    • Moura, L.1
  • 37
    • 0021502873 scopus 로고
    • Effective algorithms for circle fitting
    • Chernov N.I., Ososkov G.A. Effective algorithms for circle fitting. Comput Phys Commun 1984, 33:329-333.
    • (1984) Comput Phys Commun , vol.33 , pp. 329-333
    • Chernov, N.I.1    Ososkov, G.A.2
  • 39
    • 77949423722 scopus 로고    scopus 로고
    • The effect of voxel size on image reconstruction in cone-beam computed tomography
    • Tanimoto H., Ara Y. The effect of voxel size on image reconstruction in cone-beam computed tomography. Oral Radiol 2009, 25:149-153.
    • (2009) Oral Radiol , vol.25 , pp. 149-153
    • Tanimoto, H.1    Ara, Y.2
  • 40
    • 84866083849 scopus 로고    scopus 로고
    • A multi-thread scheduling method for 3D CT image reconstruction using multi-GPU
    • Zhu Y., Zhao Y., Zhao X. A multi-thread scheduling method for 3D CT image reconstruction using multi-GPU. J X-ray Sci Technol 2012, 20:187-197.
    • (2012) J X-ray Sci Technol , vol.20 , pp. 187-197
    • Zhu, Y.1    Zhao, Y.2    Zhao, X.3
  • 41
    • 69549110064 scopus 로고    scopus 로고
    • Acceleration ray tracing for radiotherapy dose calculation on a GPU
    • Greef M.D., Crezee J., Eijk J.C.V., Pool R., Bel A. Acceleration ray tracing for radiotherapy dose calculation on a GPU. Med Phys 2009, 36:4095-4102.
    • (2009) Med Phys , vol.36 , pp. 4095-4102
    • Greef, M.D.1    Crezee, J.2    Eijk, J.C.V.3    Pool, R.4    Bel, A.5
  • 44
    • 31044451240 scopus 로고    scopus 로고
    • Asimple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT
    • Siewerdsen J.H., Daly M.J., Bakhtiar B., Moseley D.J., Richard S., Keller H., et al. Asimple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT. Med Phys 2006, 33:187-197.
    • (2006) Med Phys , vol.33 , pp. 187-197
    • Siewerdsen, J.H.1    Daly, M.J.2    Bakhtiar, B.3    Moseley, D.J.4    Richard, S.5    Keller, H.6
  • 45
    • 2442636501 scopus 로고    scopus 로고
    • Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy
    • Hunt D.C., Tousignant O., Rowlands J.A. Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy. Med Phys 2004, 31:1166-1175.
    • (2004) Med Phys , vol.31 , pp. 1166-1175
    • Hunt, D.C.1    Tousignant, O.2    Rowlands, J.A.3
  • 46
    • 2442689175 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for cone beam CT imaging
    • Ning R.L., Tang X.Y., Conover D. X-ray scatter correction algorithm for cone beam CT imaging. Med Phys 2004, 31:1195-1202.
    • (2004) Med Phys , vol.31 , pp. 1195-1202
    • Ning, R.L.1    Tang, X.Y.2    Conover, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.