메뉴 건너뛰기




Volumn 19, Issue 3, 2011, Pages 333-343

A new 3D information acquisition method of micro-drilling marks on ancient perforated stone bead through micro-CT

Author keywords

Ancient drilling technique; image denoising; T FDK algorithm; three dimensional micro computed tomography

Indexed keywords

3D INFORMATION; CT SYSTEM; DE-NOISING ALGORITHM; DRILLING TECHNIQUES; DRILLING TECHNOLOGY; DRILLING TOOL; GEOMETRICAL INFORMATIONS; IMAGE DE-NOISING; INFORMATION ACQUISITIONS; INNER WALLS; MICRO CT; MICRO-DRILLING; NL-MEANS; NONDESTRUCTIVE METHODS; T-FDK ALGORITHM;

EID: 80052610689     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: 10.3233/XST-2011-0297     Document Type: Article
Times cited : (13)

References (11)
  • 1
    • 4544355533 scopus 로고    scopus 로고
    • The identification of carving techniques on Chinese jade
    • DOI 10.1016/j.jas.2004.03.007, PII S0305440304000421
    • M. Sax, N.D. Meeks and C. Michaelson, The identification of carving techniques on Chinese jade, Journal of Archaeological Science 31 (2004), 1413-1428. (Pubitemid 39239087)
    • (2004) Journal of Archaeological Science , vol.31 , Issue.10 , pp. 1413-1428
    • Sax, M.1    Meeks, N.D.2    Michaelson, C.3    Middleton, A.P.4
  • 2
    • 84972048049 scopus 로고
    • Making stone vessels in ancient mesopotamia and egypt
    • D.A. Stocks, Making Stone vessels in Ancient Mesopotamia and Egypt, Antiquity 67 (1993), 596-603.
    • (1993) Antiquity , vol.67 , pp. 596-603
    • Stocks, D.A.1
  • 3
    • 78650846266 scopus 로고    scopus 로고
    • High resolution in vivo micro-CT with flat panel detector based on amorphous silicon
    • X. Yang, Y. Meng, Q. Luo and H. Gong, High resolution in vivo micro-CT with flat panel detector based on amorphous silicon, Journal of X-Ray Science and Technology 18 (2010), 381-392.
    • (2010) Journal of X-Ray Science and Technology , vol.18 , pp. 381-392
    • Yang, X.1    Meng, Y.2    Luo, Q.3    Gong, H.4
  • 4
    • 77954730565 scopus 로고    scopus 로고
    • Accurate 3D data stitching in circular cone-beam micro-CT
    • C. Ji, Accurate 3D data stitching in circular cone-beam micro-CT, Journal of X-Ray Science and Technology 18 (2010), 99-110.
    • (2010) Journal of X-Ray Science and Technology , vol.18 , pp. 99-110
    • Ji, C.1
  • 9
    • 38049144745 scopus 로고    scopus 로고
    • Nonlocal image and movie denoising
    • A. Buades, B. Coll and J.-M. Morel, Nonlocal Image and Movie Denoising, Int J Comput Vis 76 (2008), 123-139.
    • (2008) Int J Comput Vis , vol.76 , pp. 123-139
    • Buades, A.1    Coll, B.2    Morel, J.-M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.