메뉴 건너뛰기




Volumn 24, Issue 4, 2014, Pages

A wireless intraocular pressure monitoring device with a solder-filled microchannel antenna

Author keywords

bio mems; cataract; glaucoma; implantable sensor; intraocular pressure; pressure sensor

Indexed keywords

ANTENNAS; DATA TRANSFER; PRESSURE SENSORS;

EID: 84897535708     PISSN: 09601317     EISSN: 13616439     Source Type: Journal    
DOI: 10.1088/0960-1317/24/4/045012     Document Type: Article
Times cited : (27)

References (15)
  • 1
    • 14544301551 scopus 로고    scopus 로고
    • Glaucoma is second leading cause of blindness globally
    • Kingman S 2004 Glaucoma is second leading cause of blindness globally Bull. World Health Organ. 82 887-8
    • (2004) Bull. World Health Organ. , vol.82 , pp. 887-888
    • Kingman, S.1
  • 2
    • 33644655886 scopus 로고    scopus 로고
    • The number of people with glaucoma worldwide in 2010 and 2020
    • DOI 10.1136/bjo.2005.081224
    • Quigley H A and Broman A T 2006 The number of people with glaucoma worldwide in 2010 and 2020 Br. J. Ophthalmol. 90 262-7 (Pubitemid 43325451)
    • (2006) British Journal of Ophthalmology , vol.90 , Issue.3 , pp. 262-267
    • Quigley, H.1    Broman, A.T.2
  • 3
    • 0028426443 scopus 로고
    • A system for passive implantable pressure sensors
    • 10.1016/0924-4247(93)00664-P 0924-4247
    • Rosengren L et al 1994 A system for passive implantable pressure sensors Sensors Actuators A 43 55
    • (1994) Sensors Actuators A , vol.43 , pp. 55
    • Rosengren, L.1
  • 5
    • 0034247925 scopus 로고    scopus 로고
    • Initial investigations on systems for measuring intraocular pressure
    • 10.1016/S0924-4247(00)00426-X 0924-4247
    • Schnakenberg U et al 2000 Initial investigations on systems for measuring intraocular pressure Sensors Actuators A 85 287
    • (2000) Sensors Actuators A , vol.85 , pp. 287
    • Schnakenberg, U.1
  • 6
    • 33644893649 scopus 로고    scopus 로고
    • Unpowered spiral-tube parylene pressure sensor for intraocular pressure sensing
    • 10.1016/j.sna.2005.08.027 0924-4247
    • Chen P-J et al 2006 Unpowered spiral-tube parylene pressure sensor for intraocular pressure sensing Sensors Actuators A 127 276-82
    • (2006) Sensors Actuators A , vol.127 , pp. 276-282
    • Chen, P.-J.1
  • 7
    • 57449102575 scopus 로고    scopus 로고
    • Microfabricated implantable parylene-based wireless passive intraocular pressure sensors
    • 10.1109/JMEMS.2008.2004945 1057-7157
    • Chen P J et al 2008 Microfabricated implantable parylene-based wireless passive intraocular pressure sensors J. Microelectromech. Syst. 17 1342-51
    • (2008) J. Microelectromech. Syst. , vol.17 , pp. 1342-1351
    • Chen, P.J.1
  • 8
    • 79953794402 scopus 로고    scopus 로고
    • A 3D implantable microsystem for intraocular pressure monitoring using a glass-in-silicon reflow process
    • 10.1109/MEMSYS.2011.5734595
    • Haque R M and Wise K D 2011 A 3D implantable microsystem for intraocular pressure monitoring using a glass-in-silicon reflow process MEMS'11: IEEE 24th Int. Conf. on Micro Electro Mechanical Systems pp 995-8
    • (2011) MEMS'11: IEEE 24th Int. Conf. on Micro Electro Mechanical Systems , pp. 995-998
    • Haque, R.M.1    Wise, K.D.2
  • 9
    • 84860440184 scopus 로고    scopus 로고
    • An ocular tack for minimally invasive continuous wireless monitoring of intraocular pressure
    • 10.1109/MEMSYS.2012.6170336
    • Chitnis G D et al 2012 An ocular tack for minimally invasive continuous wireless monitoring of intraocular pressure MEMS'12: IEEE 25th Int. Conf. on Micro Electro Mechanical Systems pp 922-5
    • (2012) MEMS'12: IEEE 25th Int. Conf. on Micro Electro Mechanical Systems , pp. 922-925
    • Chitnis, G.D.1
  • 11
    • 66249135995 scopus 로고    scopus 로고
    • Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes
    • 10.1111/j.1755-3768.2008.01404.x 0001-639X
    • Leonardi M et al 2009 Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes Acta Ophthalmol. 87 433-7
    • (2009) Acta Ophthalmol. , vol.87 , pp. 433-437
    • Leonardi, M.1
  • 12
    • 80255123472 scopus 로고    scopus 로고
    • A 2.3 uW wireless intraocular pressure/temperature
    • 10.1109/JSSC.2011.2164134 0018-9200
    • Shih Y C, Otis B P and Shen T 2011 A 2.3 uW wireless intraocular pressure/temperature IEEE J. Solid State Circuits 46 2592-601
    • (2011) IEEE J. Solid State Circuits , vol.46 , pp. 2592-2601
    • Shih, Y.C.1    Otis, B.P.2    Shen, T.3
  • 13
    • 38649090994 scopus 로고    scopus 로고
    • Outcomes of coaxial microincision cataract surgery versus conventional coaxial cataract surgery
    • DOI 10.1016/j.jcrs.2007.09.037, PII S0886335007019347
    • Dosso A A et al 2008 Outcomes of coaxial microincision cataract surgery versus conventional coaxial cataract surgery J. Cataract Refrac. Surg. 34 284-8 (Pubitemid 351173622)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.2 , pp. 284-288
    • Dosso, A.A.1    Cottet, L.2    Burgener, N.D.3    Di Nardo, S.4
  • 14
    • 84860490781 scopus 로고    scopus 로고
    • Packaging for a wireless intraocular pressure sensor with a solder-filled microchannel antenna
    • 10.1109/MEMSYS.2012.6170350
    • Varel Ç et al 2012 Packaging for a wireless intraocular pressure sensor with a solder-filled microchannel antenna MEMS: IEEE 25th Int. Conf. on Micro Electro Mechanical Systems (Paris, France,) pp 981-4
    • (2012) MEMS: IEEE 25th Int. Conf. on Micro Electro Mechanical Systems , pp. 981-984
    • Varel, Ç.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.