메뉴 건너뛰기




Volumn 85, Issue 1, 2000, Pages 287-291

Initial investigations on systems for measuring intraocular pressure

Author keywords

[No Author keywords available]

Indexed keywords

DATA COMMUNICATION SYSTEMS; ENERGY TRANSFER; INTRAOCULAR LENSES; PRESSURE MEASUREMENT; SILICONE COATINGS; TRANSPONDERS;

EID: 0034247925     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0924-4247(00)00426-X     Document Type: Article
Times cited : (50)

References (13)
  • 1
    • 0016233496 scopus 로고
    • Intraocular pressure measurement with instrumented contact lenses
    • Greene M.E., Gilman B.G. Intraocular pressure measurement with instrumented contact lenses. Invest. Ophthalmol. 13(4):1974;229-302.
    • (1974) Invest. Ophthalmol. , vol.13 , Issue.4 , pp. 229-302
    • Greene, M.E.1    Gilman, B.G.2
  • 2
    • 0017350479 scopus 로고
    • Passive radiotemetry of intraocular pressure in vitro
    • Cooper R.L., Beale D. Passive radiotemetry of intraocular pressure in vitro. Invest. Ophthalmol. Visual Sci. 26(2):1977;168-170.
    • (1977) Invest. Ophthalmol. Visual Sci. , vol.26 , Issue.2 , pp. 168-170
    • Cooper, R.L.1    Beale, D.2
  • 4
  • 5
    • 0014080792 scopus 로고
    • Miniature passive pressure transensor for implanting in the eye
    • Collins C.C. Miniature passive pressure transensor for implanting in the eye. IEEE Trans. Biomed. Eng. BME-14:1967;74-83.
    • (1967) IEEE Trans. Biomed. Eng. , vol.14 , pp. 74-83
    • Collins, C.C.1
  • 6
    • 0025698114 scopus 로고
    • Passive silicone transensor intended for biomedical, remote pressure monitoring
    • Bäcklund Y., Rosengren L., Hök B., Svedbergh B. Passive silicone transensor intended for biomedical, remote pressure monitoring. Sens. Actuators, A. 21-23:1990;58-61.
    • (1990) Sens. Actuators, a , vol.2123 , pp. 58-61
    • Bäcklund, Y.1    Rosengren, L.2    Hök, B.3    Svedbergh, B.4
  • 7
    • 0026913146 scopus 로고
    • A system for wireless intra-ocular pressure measurements using a silicon micromachined sensor
    • Rosengren L., Bäcklund Y., Sjöström T., Hök B., Svedbergh B. A system for wireless intra-ocular pressure measurements using a silicon micromachined sensor. J. Micromech. Microeng. 2:1992;202-204.
    • (1992) J. Micromech. Microeng. , vol.2 , pp. 202-204
    • Rosengren, L.1    Bäcklund, Y.2    Sjöström, T.3    Hök, B.4    Svedbergh, B.5
  • 8
    • 0027611922 scopus 로고
    • Capacitive sensors: When and how to use them
    • Puers R. Capacitive sensors: when and how to use them. Sens. Actuators, A. 37-38:1993;93-105.
    • (1993) Sens. Actuators, a , vol.3738 , pp. 93-105
    • Puers, R.1
  • 10
    • 0030382296 scopus 로고    scopus 로고
    • Compatible CMOS microsystems for automotive and for medical applications
    • Kersjes R., Mokwa W. Compatible CMOS microsystems for automotive and for medical applications. SPIE. 2882:1996;37-48.
    • (1996) SPIE , vol.2882 , pp. 37-48
    • Kersjes, R.1    Mokwa, W.2
  • 11
    • 0343521743 scopus 로고
    • Capacitive silicon pressure sensor for invasive measurement of blood pressure
    • Kandler M., Mokwa W. Capacitive silicon pressure sensor for invasive measurement of blood pressure. MME Techn. Dig. 1990.
    • (1990) MME Techn. Dig.
    • Kandler, M.1    Mokwa, W.2
  • 12
    • 0028428486 scopus 로고
    • Surface micromachined pressure sensors with integrated CMOS read-out electronics
    • Dudaicevs H., Kandler M., Manoli Y., Mokwa W., Spiegel E. Surface micromachined pressure sensors with integrated CMOS read-out electronics. Sens. Actuators, A. 43:1994;157-163.
    • (1994) Sens. Actuators, a , vol.43 , pp. 157-163
    • Dudaicevs, H.1    Kandler, M.2    Manoli, Y.3    Mokwa, W.4    Spiegel, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.