메뉴 건너뛰기




Volumn , Issue , 2012, Pages 922-925

An ocular tack for minimally invasive continuous wireless monitoring of intraocular pressure

Author keywords

[No Author keywords available]

Indexed keywords

IN-VITRO TESTS; IN-VIVO TESTS; INTRA OCULAR PRESSURE; INTRAOCULAR; MINIMALLY INVASIVE; PRESSURE SENSING; WIRELESS MONITORING;

EID: 84860440184     PISSN: 10846999     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MEMSYS.2012.6170336     Document Type: Conference Paper
Times cited : (4)

References (11)
  • 1
    • 0014080792 scopus 로고
    • Miniature passive pressure transensor for implanting in the eye
    • C. C. Collins, "Miniature passive pressure transensor for implanting in the eye," IEEE Trans. Biomed. Eng., vol. 14, no. 2, pp. 74-83, 1967.
    • (1967) IEEE Trans. Biomed. Eng. , vol.14 , Issue.2 , pp. 74-83
    • Collins, C.C.1
  • 2
    • 79955031844 scopus 로고    scopus 로고
    • Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: Initial clinical experience in patients with open angle glaucoma
    • K. Mansouri and T. Shaarawy, "Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma, " Br. J. Ophthalmology, vol. 95, no. 5, pp. 627-629, 2011.
    • (2011) Br. J. Ophthalmology , vol.95 , Issue.5 , pp. 627-629
    • Mansouri, K.1    Shaarawy, T.2
  • 3
    • 77952576025 scopus 로고    scopus 로고
    • Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent
    • E. Y. Chow, A. L. Chlebowski, S. Chakraborty, W. J. Chappell, and P. P. Irazoqui, "Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent.," IEEE Trans. Biomed. Eng., vol. 57, no. 6, pp. 1487-96, 2010.
    • (2010) IEEE Trans. Biomed. Eng. , vol.57 , Issue.6 , pp. 1487-1496
    • Chow, E.Y.1    Chlebowski, A.L.2    Chakraborty, S.3    Chappell, W.J.4    Irazoqui, P.P.5
  • 4
    • 77955453692 scopus 로고    scopus 로고
    • Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible- Coiled LC Sensor Implant
    • P.J. Chen, S. Saati, R. Varma, M. S. Humayun, and Y.-C. Tai, "Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible- Coiled LC Sensor Implant," J. Microelectromech. Syst., vol. 19, no. 4, pp. 721-734, 2010.
    • (2010) J. Microelectromech. Syst. , vol.19 , Issue.4 , pp. 721-734
    • Chen, P.J.1    Saati, S.2    Varma, R.3    Humayun, M.S.4    Tai, Y.-C.5
  • 5
    • 79953794402 scopus 로고    scopus 로고
    • A 3D implantable microsystem for intraocular pressure monitoring using a glass-in-silicon reflow process
    • R. Haque and K. Wise, "A 3D implantable microsystem for intraocular pressure monitoring using a glass-in-silicon reflow process," in MEMS-2011 IEEE 24th International Conference on, 2011, pp. 995-998.
    • MEMS-2011 IEEE 24th International Conference on, 2011 , pp. 995-998
    • Haque, R.1    Wise, K.2
  • 6
    • 36749050240 scopus 로고    scopus 로고
    • Intraocular Pressure Monitoring Sensors
    • K. C. Katuri, S. Asrani, and M. K. Ramasubramanian, "Intraocular Pressure Monitoring Sensors," IEEE Sensors J., vol. 8, no. 1, pp. 9-16, 2008.
    • (2008) IEEE Sensors J , vol.8 , Issue.1 , pp. 9-16
    • Katuri, K.C.1    Asrani, S.2    Ramasubramanian, M.K.3
  • 7
    • 33751505840 scopus 로고    scopus 로고
    • Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry
    • J. M. Martinez-de-la-Casa et al., "Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry," Ophthalmology, vol. 113, no. 12, pp. 2156-62, 2006.
    • (2006) Ophthalmology , vol.113 , Issue.12 , pp. 2156-2162
    • Martinez-de-la-Casa, J.M.1
  • 8
    • 34548022426 scopus 로고    scopus 로고
    • Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes
    • S. Shah, M. Laiquzzaman, R. Bhojwani, S. Mantry, and I. Cunliffe, "Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes.,"Investigative ophthalmology & visual science, vol. 48, no. 7, pp. 3026-31, 2007.
    • (2007) Investigative Ophthalmology & Visual Science , vol.48 , Issue.7 , pp. 3026-3031
    • Shah, S.1    Laiquzzaman, M.2    Bhojwani, R.3    Mantry, S.4    Cunliffe, I.5
  • 9
    • 79955705568 scopus 로고    scopus 로고
    • A cubic-millimeter energy-autonomous wireless intraocular pressure monitor
    • G. Chen et al., "A cubic-millimeter energy-autonomous wireless intraocular pressure monitor,"in Digest Tech. ISSCC-2011 IEEE International, pp. 310-312, 2011.
    • (2011) Digest Tech. ISSCC-2011 IEEE International , pp. 310-312
    • Chen, G.1
  • 10
    • 0036686314 scopus 로고    scopus 로고
    • Wireless micromachined ceramic pressure sensor for high-temperature applications
    • M. a Fonseca, J. M. English, M. von Arx, and M. G. Allen, "Wireless micromachined ceramic pressure sensor for high-temperature applications," J. Microelectromech. Syst., vol. 11, no. 4, pp. 337-343, 2002.
    • (2002) J. Microelectromech. Syst. , vol.11 , Issue.4 , pp. 337-343
    • Fonseca, M.A.1    English, J.M.2    Von Arx, M.3    Allen, M.G.4
  • 11
    • 0035892868 scopus 로고    scopus 로고
    • A wireless batch sealed absolute capacitive pressure sensor
    • O. Akar, T. Akin, and K. Najafi, "A wireless batch sealed absolute capacitive pressure sensor," Sens. Actuators, A, vol. 95, no. 1, pp. 29-38, 2001.
    • (2001) Sens. Actuators, A , vol.95 , Issue.1 , pp. 29-38
    • Akar, O.1    Akin, T.2    Najafi, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.