메뉴 건너뛰기




Volumn 74, Issue 4, 2014, Pages 375-380

Comparative effectiveness of 3-dimensional vs 2-dimensional and high-definition vs standard-definition neuroendoscopy: A preclinical randomized crossover study

Author keywords

3 dimensional; 3D; Endoscopy; HD; High definition; Minimally invasive neurosurgery

Indexed keywords

ACCURACY; ADULT; ARTICLE; COMPARATIVE EFFECTIVENESS; CROSSOVER PROCEDURE; DEPTH PERCEPTION; FEMALE; HIGH DEFINITION NEUROENDOSCOPY; HUMAN; IMAGE QUALITY; LIKERT SCALE; MALE; NEUROENDOSCOPY; NEUROLOGICAL ENDOSCOPE; NEUROSURGEON; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RANDOMIZATION; STANDARD DEFINITION NEUROENDOSCOPY; TASK PERFORMANCE; THREE DIMENSIONAL NEUROENDOSCOPY; TWO DIMENSIONAL NEUROENDOSCOPY; UNIVERSITY HOSPITAL; WORKLOAD; ANATOMIC MODEL; BRAIN; CONTROLLED STUDY; PROCEDURES; RANDOMIZED CONTROLLED TRIAL; SURGERY; THREE DIMENSIONAL IMAGING;

EID: 84897443582     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/NEU.0000000000000249     Document Type: Article
Times cited : (39)

References (26)
  • 1
    • 67649092264 scopus 로고    scopus 로고
    • Keyhole to the brain: Walter Dandy and neuroendoscopy
    • Hsu W, Li KW, Bookland M, Jallo GI. Keyhole to the brain: Walter Dandy and neuroendoscopy. J Neurosurg Pediatr. 2009;3(5):439-442.
    • (2009) J Neurosurg Pediatr. , vol.3 , Issue.5 , pp. 439-442
    • Hsu, W.1    Li, K.W.2    Bookland, M.3    Jallo, G.I.4
  • 2
    • 0030254666 scopus 로고    scopus 로고
    • Comparative study of various 2-D and 3-D vision systems in minimally invasive surgery [in German]
    • Buess GF, van Bergen P, Kunert W, Schurr MO. Comparative study of various 2-D and 3-D vision systems in minimally invasive surgery [in German]. Chirurg. 1996;67(10):1041-1046.
    • (1996) Chirurg. , vol.67 , Issue.10 , pp. 1041-1046
    • Buess, G.F.1    Van Bergen, P.2    Kunert, W.3    Schurr, M.O.4
  • 3
    • 41149088826 scopus 로고    scopus 로고
    • Evaluation of three laparoscopic modalities: Robotics versus three-dimensional vision laparoscopy versus standard laparoscopy
    • LaGrange CA, Clark CJ, Gerber EW, Strup SE. Evaluation of three laparoscopic modalities: robotics versus three-dimensional vision laparoscopy versus standard laparoscopy. J Endourol. 2008;22(3):511-516.
    • (2008) J Endourol. , vol.22 , Issue.3 , pp. 511-516
    • Lagrange, C.A.1    Clark, C.J.2    Gerber, E.W.3    Strup, S.E.4
  • 4
    • 0032731868 scopus 로고    scopus 로고
    • The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons
    • Taffinder N, Smith SG, Huber J, Russell RC, Darzi A. The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons. Surg Endosc. 1999;13(11):1087-1092.
    • (1999) Surg Endosc. , vol.13 , Issue.11 , pp. 1087-1092
    • Taffinder, N.1    Smith, S.G.2    Huber, J.3    Russell, R.C.4    Darzi, A.5
  • 5
    • 77955658341 scopus 로고    scopus 로고
    • Comparison of two-and three-dimensional camera systems in laparoscopic performance: A novel 3D system with one camera
    • Kong SH, Oh BM, Yoon H, et al. Comparison of two-and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one camera. Surg Endosc. 2010;24(5):1132-1143.
    • (2010) Surg Endosc. , vol.24 , Issue.5 , pp. 1132-1143
    • Kong, S.H.1    Oh, B.M.2    Yoon, H.3
  • 6
    • 33846316424 scopus 로고    scopus 로고
    • Impact of 2D and 3D vision on performance of novice subjects using da Vinci robotic system
    • Blavier A, Gaudissart Q, Cadiere GB, Nyssen AS. Impact of 2D and 3D vision on performance of novice subjects using da Vinci robotic system. Acta Chir Belg. 2006;106(6):662-664.
    • (2006) Acta Chir Belg. , vol.106 , Issue.6 , pp. 662-664
    • Blavier, A.1    Gaudissart, Q.2    Cadiere, G.B.3    Nyssen, A.S.4
  • 7
    • 67349142164 scopus 로고    scopus 로고
    • Value of high-definition imaging in neuroendoscopy
    • discussion 308
    • Schroeder HW, Nehlsen M. Value of high-definition imaging in neuroendoscopy. Neurosurg Rev. 2009;32(3):303-308; discussion 308.
    • (2009) Neurosurg Rev. , vol.32 , Issue.3 , pp. 303-308
    • Schroeder, H.W.1    Nehlsen, M.2
  • 8
    • 65449145206 scopus 로고    scopus 로고
    • Three-dimensional neuroster-eoendoscopy: Subjective and objective comparison to 2D
    • Fraser JF, Allen B, Anand VK, Schwartz TH. Three-dimensional neuroster-eoendoscopy: subjective and objective comparison to 2D. Minim Invasive Neurosurg. 2009;52(1):25-31.
    • (2009) Minim Invasive Neurosurg. , vol.52 , Issue.1 , pp. 25-31
    • Fraser, J.F.1    Allen, B.2    Anand, V.K.3    Schwartz, T.H.4
  • 9
    • 79551533767 scopus 로고    scopus 로고
    • High-definition imaging in endoscopic transsphenoidal pituitary surgery
    • Conrad J, Philipps M, Oertel J. High-definition imaging in endoscopic transsphenoidal pituitary surgery. Am J Rhinol Allergy. 2011;25(1):e13-e17.
    • (2011) Am J Rhinol Allergy. , vol.25 , Issue.1
    • Conrad, J.1    Philipps, M.2    Oertel, J.3
  • 10
    • 84907878428 scopus 로고    scopus 로고
    • Robotics in keyhole transcranial endoscope-assisted microsurgery: A critical review of existing systems and proposed specifications for new robotic platforms [published August 5, 2013]
    • doi:10.1227/NEU.0000000000000123
    • Marcus HJ, Seneci CA, Payne CJ, Nandi D, Darzi A, Yang GZ. Robotics in keyhole transcranial endoscope-assisted microsurgery: a critical review of existing systems and proposed specifications for new robotic platforms [published August 5, 2013]. Neurosurgery. doi:10.1227/NEU.0000000000000123.
    • Neurosurgery
    • Marcus, H.J.1    Seneci, C.A.2    Payne, C.J.3    Nandi, D.4    Darzi, A.5    Yang, G.Z.6
  • 12
    • 79551506161 scopus 로고    scopus 로고
    • Surgical approaches to the orbital apex: Comparison of endoscopic endonasal and transcranial approaches using a novel 3D endoscope
    • Roth J, Fraser JF, Singh A, Bernardo A, Anand VK, Schwartz TH. Surgical approaches to the orbital apex: comparison of endoscopic endonasal and transcranial approaches using a novel 3D endoscope. Orbit. 2011;30 (1):43-48.
    • (2011) Orbit. , vol.30 , Issue.1 , pp. 43-48
    • Roth, J.1    Fraser, J.F.2    Singh, A.3    Bernardo, A.4    Anand, V.K.5    Schwartz, T.H.6
  • 13
    • 74349128761 scopus 로고    scopus 로고
    • Three-dimensional and 2-dimensional endoscopic exposure of midline cranial base targets using expanded endonasal and transcranial approaches
    • discussion 1128-1130
    • Roth J, Singh A, Nyquist G, et al. Three-dimensional and 2-dimensional endoscopic exposure of midline cranial base targets using expanded endonasal and transcranial approaches. Neurosurgery. 2009;65(6):1116-1128; discussion 1128-1130.
    • (2009) Neurosurgery. , vol.65 , Issue.6 , pp. 1116-1128
    • Roth, J.1    Singh, A.2    Nyquist, G.3
  • 14
    • 84861722813 scopus 로고    scopus 로고
    • Endoscopic transnasal resection of anterior skull base malignancy with a novel 3D endoscope and neuronavigation
    • Castelnuovo P, Battaglia P, Bignami M, et al. Endoscopic transnasal resection of anterior skull base malignancy with a novel 3D endoscope and neuronavigation. Acta Otorhinolaryngol Ital. 2012;32(3):189-191.
    • (2012) Acta Otorhinolaryngol Ital. , vol.32 , Issue.3 , pp. 189-191
    • Castelnuovo, P.1    Battaglia, P.2    Bignami, M.3
  • 15
    • 84861126296 scopus 로고    scopus 로고
    • Comparison of traditional 2-dimensional endoscopic pituitary surgery with new 3-dimensional endoscopic technology: Intraoperative and early postoperative factors
    • Kari E, Oyesiku NM, Dadashev V, Wise SK. Comparison of traditional 2-dimensional endoscopic pituitary surgery with new 3-dimensional endoscopic technology: intraoperative and early postoperative factors. Int Forum Allergy Rhinol. 2012;2(1):2-8.
    • (2012) Int Forum Allergy Rhinol. , vol.2 , Issue.1 , pp. 2-8
    • Kari, E.1    Oyesiku, N.M.2    Dadashev, V.3    Wise, S.K.4
  • 16
    • 40949115266 scopus 로고
    • Development of NASA-TLX (Task Load Index): Results of empirical and theoretical research
    • Peter AH, Najmedin M, eds, Amsterdam, the Netherlands: North-Holland
    • Hart SG, Staveland LE. Development of NASA-TLX (Task Load Index): results of empirical and theoretical research. In: Peter AH, Najmedin M, eds. Advances in Psychology. Vol 52. Amsterdam, the Netherlands: North-Holland; 1988:139-183.
    • (1988) Advances in Psychology. , vol.52 , pp. 139-183
    • Hart, S.G.1    Staveland, L.E.2
  • 17
    • 84863525120 scopus 로고    scopus 로고
    • 3D HD versus 2D HD: Surgical task efficiency in standardised phantom tasks
    • Storz P, Buess GF, Kunert W, Kirschniak A. 3D HD versus 2D HD: surgical task efficiency in standardised phantom tasks. Surg Endosc. 2012;26(5):1454- 1460.
    • (2012) Surg Endosc. , vol.26 , Issue.5 , pp. 1454-1460
    • Storz, P.1    Buess, G.F.2    Kunert, W.3    Kirschniak, A.4
  • 18
    • 84897926112 scopus 로고    scopus 로고
    • Evaluation of the three-dimensional endoscope in transsphenoidal surgery
    • discussion ons78-ons79
    • Barkhoudarian G, Romero AD, Laws ER. Evaluation of the three-dimensional endoscope in transsphenoidal surgery. Neurosurgery. 2013;73(1 suppl Operative): ons74-ons78; discussion ons78-ons79.
    • (2013) Neurosurgery. , vol.73 , Issue.1 SUPPL. OPERATIVE
    • Barkhoudarian, G.1    Romero, A.D.2    Laws, E.R.3
  • 19
    • 0029283749 scopus 로고
    • Perceived depth from simultaneous changes in length and direction of a single line
    • Steele KM, Brigner WL, Adkins A. Perceived depth from simultaneous changes in length and direction of a single line. Percept Mot Skills. 1995;80(2):579-584.
    • (1995) Percept Mot Skills. , vol.80 , Issue.2 , pp. 579-584
    • Steele, K.M.1    Brigner, W.L.2    Adkins, A.3
  • 20
    • 0033659067 scopus 로고    scopus 로고
    • Depth cue integration: Stereopsis and image blur
    • Mather G, Smith DR. Depth cue integration: stereopsis and image blur. Vision Res. 2000;40(25):3501-3506.
    • (2000) Vision Res. , vol.40 , Issue.25 , pp. 3501-3506
    • Mather, G.1    Smith, D.R.2
  • 22
    • 76649136473 scopus 로고    scopus 로고
    • Motion parallax as an independent cue for depth perception: A retrospective
    • Rogers B. Motion parallax as an independent cue for depth perception: a retrospective. Perception. 2009;38(6):907-911.
    • (2009) Perception. , vol.38 , Issue.6 , pp. 907-911
    • Rogers, B.1
  • 24
    • 0033989416 scopus 로고    scopus 로고
    • The effect of high-definition imaging on surgical task efficiency in minimally invasive surgery: An experimental comparison between three-dimensional imaging and direct vision through a stereoscopic TEM rectoscope
    • van Bergen P, Kunert W, Buess GF. The effect of high-definition imaging on surgical task efficiency in minimally invasive surgery: an experimental comparison between three-dimensional imaging and direct vision through a stereoscopic TEM rectoscope. Surg Endosc. 2000;14(1):71-74.
    • (2000) Surg Endosc. , vol.14 , Issue.1 , pp. 71-74
    • Van Bergen, P.1    Kunert, W.2    Buess, G.F.3
  • 26
    • 0141762641 scopus 로고    scopus 로고
    • Depth cue reliance in surgeons and medical students
    • Shah J, Buckley D, Frisby J, Darzi A. Depth cue reliance in surgeons and medical students. Surg Endosc. 2003;17(9):1472-1474.
    • (2003) Surg Endosc. , vol.17 , Issue.9 , pp. 1472-1474
    • Shah, J.1    Buckley, D.2    Frisby, J.3    Darzi, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.