메뉴 건너뛰기




Volumn 27, Issue 2, 2014, Pages 125-132

Influence of exhalation valve and nebulizer position on albuterol delivery during noninvasive positive pressure ventilation

Author keywords

Aerosol delivery; Exhalation valves; Expiratory pressure; Inspiratory pressure; Nebulizer; Noninvasive positive pressure ventilation

Indexed keywords

OXYGEN; SALBUTAMOL; SODIUM CHLORIDE; AEROSOL; BETA 2 ADRENERGIC RECEPTOR STIMULATING AGENT; BRONCHODILATING AGENT;

EID: 84897084643     PISSN: 19412711     EISSN: 19412703     Source Type: Journal    
DOI: 10.1089/jamp.2012.1024     Document Type: Article
Times cited : (32)

References (25)
  • 1
    • 0037464756 scopus 로고    scopus 로고
    • Noninvasive positive pressure ventilation to treat respiratory failure resulting from exacerbations of chronic obstructive pulmonary disease: Cochrane systematic review and metaanalysis
    • Lightowler JV, Wedzicha JA, Elliott MW, and Ram FS: Noninvasive positive pressure ventilation to treat respiratory failure resulting from exacerbations of chronic obstructive pulmonary disease: Cochrane systematic review and metaanalysis. BMJ. 2003326:185.
    • (2003) BMJ , vol.326 , pp. 185
    • Lightowler, J.V.1    Wedzicha, J.A.2    Elliott, M.W.3    Ram, F.S.4
  • 2
    • 67650367543 scopus 로고    scopus 로고
    • Non-invasive ventilation in acute respiratory failure
    • Nava S, and Hill N: Non-invasive ventilation in acute respiratory failure. Lancet. 2009374:250-259.
    • (2009) Lancet , vol.374 , pp. 250-259
    • Nava, S.1    Hill, N.2
  • 3
    • 42949119771 scopus 로고    scopus 로고
    • Noninvasive positive pressure ventilation in the acute care setting: Where are we?
    • Ambrosino N, and Vagheggini G: Noninvasive positive pressure ventilation in the acute care setting: where are we? Eur Respir J. 200831:874-886.
    • (2008) Eur Respir J , vol.31 , pp. 874-886
    • Ambrosino, N.1    Vagheggini, G.2
  • 5
    • 0028842697 scopus 로고
    • Treatment of acute bronchospasm with β-adrenergic agonist aerosols delivered by a nasal bilevel positive airway pressure circuit
    • Pollack CV Jr, Fleisch KB, and Dowsey K: Treatment of acute bronchospasm with β-adrenergic agonist aerosols delivered by a nasal bilevel positive airway pressure circuit. Ann Emerg Med. 199526:552-557.
    • (1995) Ann Emerg Med , vol.26 , pp. 552-557
    • Pollack Jr., C.V.1    Fleisch, K.B.2    Dowsey, K.3
  • 6
    • 0037390456 scopus 로고    scopus 로고
    • A pilot prospective, randomized, placebo-controlled trial of bilevel positive airway pressure in acute asthmatic attack
    • Soroksky A, Stav D, and Shpirer I: A pilot prospective, randomized, placebo-controlled trial of bilevel positive airway pressure in acute asthmatic attack. Chest. 2003123:1018-1025.
    • (2003) Chest , vol.123 , pp. 1018-1025
    • Soroksky, A.1    Stav, D.2    Shpirer, I.3
  • 7
    • 67649826855 scopus 로고    scopus 로고
    • Reversal of bronchial obstruction with bi-level positive airway pressure and nebulization in patients with acute asthma
    • Brandao DC, Lima VM, Filho VG, Silva TS, Campos TF, Dean E, and De Andrade AD: Reversal of bronchial obstruction with bi-level positive airway pressure and nebulization in patients with acute asthma. J Asthma. 200946:356-361.
    • (2009) J Asthma , vol.46 , pp. 356-361
    • Brandao, D.C.1    Lima, V.M.2    Filho, V.G.3    Silva, T.S.4    Campos, T.F.5    Dean, E.6    De Andrade, A.D.7
  • 8
    • 77954589738 scopus 로고    scopus 로고
    • A prospective randomized controlled trial on the efficacy of noninvasive ventilation in severe acute asthma
    • Gupta D, Nath A, Agarwal R, and Behera D: A prospective randomized controlled trial on the efficacy of noninvasive ventilation in severe acute asthma. Respir Care. 201055:536-543.
    • (2010) Respir Care , vol.55 , pp. 536-543
    • Gupta, D.1    Nath, A.2    Agarwal, R.3    Behera, D.4
  • 9
    • 0036852058 scopus 로고    scopus 로고
    • In vitro evaluation of aerosol bronchodilator delivery during noninvasive positive pressure ventilation: Effect of ventilator settings and nebulizer position
    • Chatmongkolchart S, Schettino GP, Dillman C, Kacmarek RM, and Hess DR: In vitro evaluation of aerosol bronchodilator delivery during noninvasive positive pressure ventilation: effect of ventilator settings and nebulizer position. Crit Care Med. 200230:2515-2519.
    • (2002) Crit Care Med , vol.30 , pp. 2515-2519
    • Chatmongkolchart, S.1    Schettino, G.P.2    Dillman, C.3    Kacmarek, R.M.4    Hess, D.R.5
  • 10
    • 84859386983 scopus 로고    scopus 로고
    • Aerosol therapy in patients receiving noninvasive positive pressure ventilation
    • Dhand R: Aerosol therapy in patients receiving noninvasive positive pressure ventilation. J Aerosol Med Pulm Drug Deliv. 201225:63-78.
    • (2012) J Aerosol Med Pulm Drug Deliv , vol.25 , pp. 63-78
    • Dhand, R.1
  • 11
    • 0036796413 scopus 로고    scopus 로고
    • Equipment needs for noninvasive mechanical ventilation
    • Schonhofer B, and Sortor-Leger S: Equipment needs for noninvasive mechanical ventilation. Eur Respir J. 200220:1029-1036.
    • (2002) Eur Respir J , vol.20 , pp. 1029-1036
    • Schonhofer, B.1    Sortor-Leger, S.2
  • 12
    • 0025174713 scopus 로고
    • Pressurized aerosol versus jet aerosol delivery to mechanically ventilated patients. Comparison of dose to the lungs
    • Fuller HD, Dolovich MB, Posmituck G, Pack WW, and Newhouse MT: Pressurized aerosol versus jet aerosol delivery to mechanically ventilated patients. Comparison of dose to the lungs. Am Rev Respir Dis. 1990141:440-444.
    • (1990) Am Rev Respir Dis , vol.141 , pp. 440-444
    • Fuller, H.D.1    Dolovich, M.B.2    Posmituck, G.3    Pack, W.W.4    Newhouse, M.T.5
  • 13
    • 0031020173 scopus 로고    scopus 로고
    • Aerosol kinetics and bronchodilator efficacy during continuous positive airway pressure delivered by face mask
    • Parkes SN, and Bersten AD: Aerosol kinetics and bronchodilator efficacy during continuous positive airway pressure delivered by face mask. Thorax. 199752:171-175.
    • (1997) Thorax , vol.52 , pp. 171-175
    • Parkes, S.N.1    Bersten, A.D.2
  • 14
    • 42649097553 scopus 로고    scopus 로고
    • Aerosol delivery during mechanical ventilation: From basic techniques to new devices
    • Dhand R: Aerosol delivery during mechanical ventilation: from basic techniques to new devices. J Aerosol Med Pulm Drug Deliv. 200821:45-60.
    • (2008) J Aerosol Med Pulm Drug Deliv , vol.21 , pp. 45-60
    • Dhand, R.1
  • 16
    • 4644317386 scopus 로고    scopus 로고
    • Inhaled bronchodilator administration during mechanical ventilation
    • Duarte AG: Inhaled bronchodilator administration during mechanical ventilation. Respir Care. 200449:623-634.
    • (2004) Respir Care , vol.49 , pp. 623-634
    • Duarte, A.G.1
  • 17
    • 33644873498 scopus 로고    scopus 로고
    • Albuterol delivery during noninvasive ventilation
    • Branconnier MP, and Hess DR: Albuterol delivery during noninvasive ventilation. Respir Care. 200550:1649-1653.
    • (2005) Respir Care , vol.50 , pp. 1649-1653
    • Branconnier, M.P.1    Hess, D.R.2
  • 19
    • 77955480004 scopus 로고    scopus 로고
    • Evaluation of aerosol generator devices at 3 locations in humidified and non-humidified circuits during adult mechanical ventilation
    • Ari A, Areabi H, and Fink JB: Evaluation of aerosol generator devices at 3 locations in humidified and non-humidified circuits during adult mechanical ventilation. Respir Care. 201055:837-844.
    • (2010) Respir Care , vol.55 , pp. 837-844
    • Ari, A.1    Areabi, H.2    Fink, J.B.3
  • 20
    • 70349896063 scopus 로고    scopus 로고
    • Influence of moisture accumulation in inline spacer on delivery of aerosol using metered-dose inhaler during mechanical ventilation
    • Lin HL, Fink JB, Zhou Y, and Cheng YS: Influence of moisture accumulation in inline spacer on delivery of aerosol using metered-dose inhaler during mechanical ventilation. Respir Care. 200954:1336-1341.
    • (2009) Respir Care , vol.54 , pp. 1336-1341
    • Lin, H.L.1    Fink, J.B.2    Zhou, Y.3    Cheng, Y.S.4
  • 22
    • 77954909965 scopus 로고    scopus 로고
    • In-vitro characterisation of the nebulised dose during non-invasive ventilation
    • Abdelrahim ME, Plant P, and Chrystyn H: In-vitro characterisation of the nebulised dose during non-invasive ventilation. J Pharm Pharmacol. 201062:966-972.
    • (2010) J Pharm Pharmacol , vol.62 , pp. 966-972
    • Abdelrahim, M.E.1    Plant, P.2    Chrystyn, H.3
  • 23
    • 0019352720 scopus 로고
    • Facemask or mouthpiece for delivery of nebulized bronchodilator aerosols?
    • Steventon RD, and Wilson RS: Facemask or mouthpiece for delivery of nebulized bronchodilator aerosols? Br J Dis Chest. 198175:88-90.
    • (1981) Br J Dis Chest , vol.75 , pp. 88-90
    • Steventon, R.D.1    Wilson, R.S.2
  • 25
    • 78649940446 scopus 로고    scopus 로고
    • Optimization of a procedure used to measure aerosol characteristics of nebulized solutions using a cooled next generation impactor
    • Berlinski A, and Hayden JB: Optimization of a procedure used to measure aerosol characteristics of nebulized solutions using a cooled Next Generation Impactor. J Aerosol Med Pulm Drug Deliv. 201023:397-404.
    • (2010) J Aerosol Med Pulm Drug Deliv , vol.23 , pp. 397-404
    • Berlinski, A.1    Hayden, J.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.