메뉴 건너뛰기




Volumn 13, Issue 1, 2014, Pages 41-53

Feasibility study on corrosion monitoring of a concrete column with central rebar using BOTDR

Author keywords

BOTDR; Distributed sensing monitoring; Expansion pressure; Optical fiber; Rebar corrosion

Indexed keywords

CONCRETE CONSTRUCTION; DEFORMATION; EXPANSION; OPTICAL FIBERS; REBAR; REFLECTOMETERS; STEEL CORROSION;

EID: 84894460337     PISSN: 17381584     EISSN: 17381991     Source Type: Journal    
DOI: 10.12989/sss.2014.13.1.041     Document Type: Article
Times cited : (31)

References (24)
  • 1
    • 0036472865 scopus 로고    scopus 로고
    • Corrosion rate evolution in concrete structures exposed to the atmosphere
    • Andrade, C., Alonso, C. and Sarria, J. (2002), "Corrosion rate evolution in concrete structures exposed to the atmosphere", Cement Concrete Comp., 24(1), 55-64.
    • (2002) Cement Concrete Comp , vol.24 , Issue.1 , pp. 55-64
    • Andrade, C.1    Alonso, C.2    Sarria, J.3
  • 2
    • 84864356853 scopus 로고    scopus 로고
    • Recent progress in distributed fiber optic sensors
    • Bao, X.Y. and Chen, L. (2012), "Recent progress in distributed fiber optic sensors", Sensors, 12, 8601-8639.
    • (2012) Sensors , vol.12 , pp. 8601-8639
    • Bao, X.Y.1    Chen, L.2
  • 3
    • 0029342573 scopus 로고
    • Experimental and theoretical studies on a distributed temperature sensor based on Brillouin scattering
    • Bao, X.Y., Dhliwayo, J., Heron, N., Webb, D.J. and Jackson, D.A. (1995), "Experimental and theoretical studies on a distributed temperature sensor based on Brillouin scattering", J. Lightwave Technol., 7(7), 1340-1347.
    • (1995) J. Lightwave Technol , vol.7 , Issue.7 , pp. 1340-1347
    • Bao, X.Y.1    Dhliwayo, J.2    Heron, N.3    Webb, D.J.4    Jackson, D.A.5
  • 4
    • 38149088814 scopus 로고    scopus 로고
    • Chloride-induced reinforcement corrosion and concrete cracking simulation
    • Chen, D. and Mahadevan, S. (2008), "Chloride-induced reinforcement corrosion and concrete cracking simulation", Cement Concrete Comp., 30(3), 227-238.
    • (2008) Cement Concrete Comp , vol.30 , Issue.3 , pp. 227-238
    • Chen, D.1    Mahadevan, S.2
  • 5
    • 4344607691 scopus 로고    scopus 로고
    • Corrosion of carbon steels in high-temperature water studied by electrochemical techniques
    • Cheng, Y.F. and Steward, F.R. (2004), "Corrosion of carbon steels in high-temperature water studied by electrochemical techniques", Corros. Sci., 46(10), 2405-2420.
    • (2004) Corros. Sci , vol.46 , Issue.10 , pp. 2405-2420
    • Cheng, Y.F.1    Steward, F.R.2
  • 6
    • 41549086206 scopus 로고    scopus 로고
    • A novel optical fiber sensor for steel corrosion in concrete structures
    • Leung, C.K.Y., Wan, K.T. and Chen, L. (2008), "A novel optical fiber sensor for steel corrosion in concrete structures", Sensors, 8, 1960-1976.
    • (2008) Sensors , vol.8 , pp. 1960-1976
    • Leung, C.K.Y.1    Wan, K.T.2    Chen, L.3
  • 8
    • 34247639422 scopus 로고    scopus 로고
    • Fiber-optic sensors for the estimation of pH within natural biofilms on metals
    • Ganesh, A.B. and Radhakrishnan, T.K. (2007), "Fiber-optic sensors for the estimation of pH within natural biofilms on metals", Sensor. Actuat. B. - Chem., 123(3), 1107-1112.
    • (2007) Sensor. Actuat. B. - Chem , vol.123 , Issue.3 , pp. 1107-1112
    • Ganesh, A.B.1    Radhakrishnan, T.K.2
  • 9
    • 78650568468 scopus 로고    scopus 로고
    • Monitoring of corrosion in reinforced concrete structure using bragg grating sensing
    • Gao, J.Q., Wu, J., Li, J. and Zhao, X.M. (2011), "Monitoring of corrosion in reinforced concrete structure using bragg grating sensing", NDT&E. Int., 44(2), 202-205.
    • (2011) NDT&E. Int , vol.44 , Issue.2 , pp. 202-205
    • Gao, J.Q.1    Wu, J.2    Li, J.3    Zhao, X.M.4
  • 10
    • 85076143085 scopus 로고    scopus 로고
    • Grating-based optical fiber corrosion sensor
    • Greene, J.A., Jones, M.E. and Duncan, P.G. (1997), "Grating-based optical fiber corrosion sensor", Proc. SPIE, 3042, 260-266.
    • (1997) Proc. SPIE , vol.3042 , pp. 260-266
    • Greene, J.A.1    Jones, M.E.2    Duncan, P.G.3
  • 12
    • 78649984319 scopus 로고    scopus 로고
    • Underwater half-cell corrosion potential bench mark measurements of corroding steel in concrete influenced by a variety of material science and environmental engineering variables
    • Hussain, R.R. (2001), "Underwater half-cell corrosion potential bench mark measurements of corroding steel in concrete influenced by a variety of material science and environmental engineering variables", Measurement, 44(1), 274-280.
    • (2001) Measurement , vol.44 , Issue.1 , pp. 274-280
    • Hussain, R.R.1
  • 14
    • 79952899965 scopus 로고    scopus 로고
    • Fe-C-coated fibre Bragg grating sensor for steel corrosion monitoring
    • Hu, W.B., Cai, H.L., Yang, M., Tong, X., Zhou, C. and Chen, W. (2011), "Fe-C-coated fibre Bragg grating sensor for steel corrosion monitoring", Corros. Sci., 53(5), 1933-1938.
    • (2011) Corros. Sci , vol.53 , Issue.5 , pp. 1933-1938
    • Hu, W.B.1    Cai, H.L.2    Yang, M.3    Tong, X.4    Zhou, C.5    Chen, W.6
  • 15
    • 33645212867 scopus 로고    scopus 로고
    • Corrosion rate of ordinary and high-performance concrete subjected to chloride attack by AC impedance spectroscopy
    • Ismail, M. and Ohtsu, M. (2006), "Corrosion rate of ordinary and high-performance concrete subjected to chloride attack by AC impedance spectroscopy", Constr. Build. Mater., 20(7), 458-469.
    • (2006) Constr. Build. Mater , vol.20 , Issue.7 , pp. 458-469
    • Ismail, M.1    Ohtsu, M.2
  • 17
    • 0027580341 scopus 로고
    • Brillouin optical-fiber time domain reflectometry
    • Kurashima, T., Horiguchi, T. and Izumita, H. (1993), "Brillouin optical-fiber time domain reflectometry", IEICE T. Commun., 4, 382-390.
    • (1993) IEICE T. Commun , vol.4 , pp. 382-390
    • Kurashima, T.1    Horiguchi, T.2    Izumita, H.3
  • 19
    • 0031074254 scopus 로고    scopus 로고
    • Fiber-optic crack-tip opening displacement sensor for concrete
    • Lee, I., Yuan, L.B., Ansari, F. and Hong, D. (1997), "Fiber-optic crack-tip opening displacement sensor for concrete", Cement Concrete Comp., 19(1), 59-68.
    • (1997) Cement Concrete Comp , vol.19 , Issue.1 , pp. 59-68
    • Lee, I.1    Yuan, L.B.2    Ansari, F.3    Hong, D.4
  • 20
  • 21
    • 67349136426 scopus 로고    scopus 로고
    • Potential pitfalls in assessing chloride-induced corrosion of steel in concrete
    • Poursaee, A. and Hansson, C.M. (2009), "Potential pitfalls in assessing chloride-induced corrosion of steel in concrete", Cement Concrete Res., 39(5), 391-400.
    • (2009) Cement Concrete Res , vol.39 , Issue.5 , pp. 391-400
    • Poursaee, A.1    Hansson, C.M.2
  • 22
    • 34249299749 scopus 로고    scopus 로고
    • Measurement of chloride-ion concentration with long-period grating technology
    • Tang, J.L. and Wang, J.N. (2007), "Measurement of chloride-ion concentration with long-period grating technology", Smart Mater.Struct., 16(3), 665-672.
    • (2007) Smart Mater.Struct , vol.16 , Issue.3 , pp. 665-672
    • Tang, J.L.1    Wang, J.N.2
  • 23
    • 82055185622 scopus 로고    scopus 로고
    • Brillouin corrosion expansion sensors for steel reinforced concrete structures using a fiber optic coil winding method
    • Zhao, X.F., Gong, P., Qiao, J., Lu, J., Lv. X. and Ou, J.(2011), "Brillouin corrosion expansion sensors for steel reinforced concrete structures using a fiber optic coil winding method", Sensors, 11, 10798-10819.
    • (2011) Sensors , vol.11 , pp. 10798-10819
    • Zhao, X.F.1    Gong, P.2    Qiao, J.3    Lu, J.4    Lv., X.5    Ou, J.6
  • 24
    • 79960706210 scopus 로고    scopus 로고
    • Damage analysis and cracking model of reinforced concrete structures with rebar corrosion
    • Zhao, Y.X., Yu, J. and Jin, W.L. (2011), "Damage analysis and cracking model of reinforced concrete structures with rebar corrosion", Corros. Sci., 53(10), 3388-3397.
    • (2011) Corros. Sci , vol.53 , Issue.10 , pp. 3388-3397
    • Zhao, Y.X.1    Yu, J.2    Jin, W.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.